3 resultados para Glow discharges
em Brock University, Canada
Resumo:
In light of the fact that literature on toxicity of heavy metals in non-acidified
freshwater systems is sparse, this project was initiated to conduct an environmental
assessment of Lake Gibson. Chemistry of soils from adjacent areas and vineyards in the
region provide a comparative background database. Water quality determinations were used
to identify and highlight areas of environmental concern within the Lake Gibson watershed.
A Shelby Corer was used to obtain 66 sediment cores from Lake Gibson. These were
sectioned according to lithology and color to yield 298 samples. A suite of 122 soil samples
was collected in the region and vicinity of Lake Gibson. All were tested for metals and
some for Total Petroleum Hydrocarbons (TPH). Evaluation of the results leads to the
following conclusions:
1. Metal concentrations ofAI, Cd, Cu, Cr, Pb, Ni, Fe and Zn in soils from the Niagara
Region are well below background limits set by the Ministry of the Environment
and Energy (MOEE) for provincial soils.
2. There is a spatial and depth difference for some of the metals within the various
soils. The Cr, Ni and Pb contents of soils vary throughout the region (p
Resumo:
The streams flowing through the Niagara Escarpment are paved by coarse carbonate and sandstone sediments which have originated from the escarpment units and can be traced downstream from their source. Fifty-nine sediment samples were taken from five streams, over distances of 3,000 to 10,000 feet (915 to 3050 m), to determine downstream changes in sediment composition, textural characteristics and sorting. In addition, fluorometric velocity measurements were used in conjunction with measured -discharge and flow records to estimate the frequency of sediment movement. The frequency of sediments of a given lithology changes downstream in direct response to the outcrop position of the formations in the channels. Clasts derived from a single stratigraphic unit usually reach a maximum frequency within the first 1,000 feet (305 m) of transport. Sediments derived from formations at the top of waterfalls reach a modal frequency farther downstream than material originating at the base of waterfalls. Downstream variations in sediment size over the lengths of the study reaches reflect the changes in channel morphology and lithologic composition of the sediment samples. Linear regression analyses indicate that there is a decrease in the axial lengths between the intial and final samples and that the long axis decreases in length more rapidly than the intermediate, while the short axis remains almost constant. Carbonate sediments from coarse-grained, fossiliferous units - iii - are more variable in size than fine-grained dolostones and sandstones. The average sphericity for carbonates and sandstones increases from 0.65 to 0.67, while maximum projection sphericity remains nearly constant with an average value of 0.52. Pebble roundness increases more rapidly than either of the sphericity parameters and the sediments change from subrounded to rounded. The Hjulstrom diagram indicates that the velocities required to initiate transport of sediments with an average intermediate diameter of 10 cm range from 200 cm/s to 300 cm/s (6.6 ft./sec. to 9.8 ft./sec.). From the modal velocitydischarge relations, the flows corresponding to these velocities are greater than 3,500 cfs (99 m3s). These discharges occur less than 0.01 p~r cent (0.4 days) of the time and correspond to a discharge occurring during the spring flood.
Resumo:
The Beckman Helium Discharge Detector has been found to be sensitive to the fixed gases oxygen, nitrogen, and hydrogen at detection levels 10-100 times more sensitive than possible with a Bow-Mac Thermal Conductivity Detector. Detection levels o~ approximately 1.9 E-4 ~ v/v oxygen, 3.1 E-4 ~ v/v nitrogen, and 3.0 E-3 ~ v/v hydrogen are estimated. Response of the Helium Discharge Detector was not linear, but is useable for quantitation over limited ranges of concentration using suitably prepared working standards. Cleanliness of the detector discharge electrodes and purity of the helium carrier and discharge gas were found to be critical to the operation of the detector. Higher sensitivities of the Helium Discharge Detector may be possible by the design and installation of a sensitive, solid-state electrometer.