4 resultados para Gas and arc welding
em Brock University, Canada
Resumo:
Note (1 page, handwritten) with calculations regarding payments for gas and other items.
Resumo:
Factors involved in the determination of PAHs (16 priority PAHs as an example) and PCBs (10 PCB congeners, representing 10 isomeric groups) by capillary gas chromatography coupled with mass spectrometry (GC/MS, for PAHs) and electron capture detection (GC/ECD , for PCBs) were studied, with emphasis on the effect of solvent. Having various volatilities and different polarities, solvent studied included dichloromethane, acetonitrile, hexan e, cyclohexane, isooctane, octane, nonane, dodecane, benzene, toluene, p-xylene, o-xylene, and mesitylene. Temperatures of the capillary column, the injection port, the GC/MS interface, the flow rates of carrier gas and make-up gas, and the injection volume were optimized by one factor at a time method or simplex optimization method. Under the optimized conditions, both peak height and peak area of 16 PAHs, especially the late-eluting PAHs, were significantly enhanced (1 to 500 times) by using relatively higher boiling point solvents such as p-xylene and nonane, compared with commonly used solvents like benzene and isooctane. With the improved sensitivity, detection limits of between 4.4 pg for naphthalene and 30.8 pg for benzo[g,h,i]perylene were obtained when p-xylene was used as an injection solvent. Effect of solvent on peak shape and peak intensity were found to be greatly dependent on temperature parameters, especially the initial temperature of the capillary column. The relationship between initial temperature and shape of peaks from 16 PAHs and 10 PCBs were studied and compared when toluene, p-xylene, isooctane, and nonane were used as injection solvents. If a too low initial temperature was used, fronting or split of peaks was observed. On the other hand, peak tailing occurred at a too high initial column temperature. The optimum initial temperature, at which both peak fronting and tailing were avoided and symmetrical peaks were obtained, depended on both solvents and the stationary phase of the column used. On a methyl silicone column, the alkane solvents provided wider optimum ranges of initial temperature than aromatic solvents did, for achieving well-shaped symmetrical GC peaks. On a 5% diphenyl: 1% vinyl: 94% dimethyl polysiloxane column, when the aromatic solvents were used, the optimum initial temperature ranges for solutes to form symmetrical peaks were improved to a similar degree as those when the alkanes were used as injection solvents. A mechanism, based on the properties of and possible interactions among the analyte, the injection solvent, and the stationary phase of the capillary column, was proposed to explain these observations. The effect of initial temperature on peak height and peak area of the 16 PAHs and the 10 PCBs was also studied. The optimum initial temperature was found to be dependent on the physical properties of the solvent used and the amount of the solvent injected. Generally, from the boiling point of the solvent to 10 0C above its boiling point was an optimum range of initial temperature at which cthe highest peak height and peak area were obtained.
Resumo:
The original objective of this work was to provide a simple generator w.hich would produce hydrogen torLfuel-cell feed and which could be operated under remote or northern conditions. A secondary objective was to maximize the yield of hydrogen and carbon monoxide from available feed-stocks. A search of the patent literature has indicated that the concept of a small Wulff-type generator is essentially sound and that hydrogen may be recovered from a wide variety of hydrocarbon feed-stocks. A simple experimental set-up has been devised, patterned after ~~t originally used by R. G. Wulff for producing acetylene. This provides a supply of feed-stock, with or Without a carrier gas, which may be passed directly through a heated tube, which may contain a catalyst. A suitable procedure has been devised for analysi~ effluent gases for hydrogen, oxygen, nitrogen, methane and carbon monoxide by gas chromatography with the column packed with .Molecular .:>ieve .5 4. Athanol with air a.s carrier gas and at the same time as oxidant o was thermolyzed at temperatures in the ra~e 700-1100 C, with or Wi~lout catalyst. Methanol with or without nitrogen as a carrier gas was also cracked with • the same type of reactor refractory tube, but the temperature range was lower t down to ,300 " C when a catalyst was used. The problems of converting methane to hydrogen and carbon monoxide effiCiently, using air and/or water as oxidants were also studied.
Resumo:
The Niagara Parks Commission administrative headquarters are located in Oak Hall which is on the cliff above Dufferin Islands. In 1798 this land was granted by the crown to United Empire Loyalist James Skinner until 1898. A century later it was the home of the Clarks, Streets and Macklems. These families controlled the mills of Bridgewater which was a pioneer industrial village located at Dufferin Islands. Then, it was known as Clark Hill. Colonel Thomas Clark, commander of the Second Lincoln Militia in the War of 1812 is the earliest known occupant of the house. When Clark died in 1837, the house went to Thomas Clark Street who was the son of the Colonel’s partner. Mr. Street was a bachelor and his sister, widow of Dr. T.C. Macklem, managed his household. Mrs. Macklem had 2 sons. The eldest son drowned in the Niagara River at the age of 8 and the younger son, Sutherland became heir to the estate. Mr. Macklem opened Cynthia Islands and Cedar Island to the public and had roads built to reach them. Two suspension bridges connected them to the mainland and tolls were charged on the bridges. The improvements to the land cost Macklem $18,962. He called the bridges “Bridge Castor” and “Bridge Pollux”. There was also an office built at the end of Bridge Castor. Macklem also spent $454 fixing up the Burning Spring Building (the burning spring is enclosed in a barrel which collects gas and lets it out through a tube at the top). Macklem received a yearly income of $56,378.79 from tourists and visitors. In 1887 Cynthia Islands and Cedar Island were deeded to the crown and became part of Queen Victoria Park. The name Cynthia was changed to Dufferin in honour of Lord Dufferin. Sources: www.niagarafrontier.com/parks.html www.niagarafrontier.com/burningsprings.html