4 resultados para F-19 Nb-93 strongly dissipative heavy-ion collisions
em Brock University, Canada
Resumo:
The objectives of the present study were to explore three components of organizational commitment (affective [AC], normative [NC] and continuance [CC] commitment; Allen & Meyer, 1991), perceived relatedness (Oeci & Ryan, 1985; 2002), and behavioural intention (Ajzen, 2002) within the context of volunteer track and field officiating. The objectives were examined in a 2-phase study. Ouring phase 1, experts (N = 10) with domain familiarity assessed the item content relevance and representation of modified organizational commitment (OC; Meyer, Allen & Smith, 1993) and perceived relatedness (La Guardia, Oeci, Ryan & Couchman, 2000) items. Fourteen of 26 (p < .05) items were relevant (Aiken's coefficient V) and NC (M = 3.88, SO = .64), CC (M = 3.63, SD = .52), and relatedness (M = 4.00, SD = .93) items had mean item content-representation ratings of either "good" or "very good" while AC (M = 2.50, SD = 0.58) was rated "fair". Participants in phase 2 (N = 80) responded to items measuring demographic variables, perceptions of OC to Athletics Canada, perceived relatedness to other track and field officials, and a measure of intention (yiu, Au & Tang, 2001) to continue officiating. Internal consistency reliability estimates (Cronbach's (1951) coefficient alpha) were as follows: (a) AC = .78, (b) CC = .85, (c) NC = .80 (d) perceived relatedness = .70 and, (e) intention = .92 in the present sample. Results suggest that the track and field officials felt only minimally committed to Athletics Canada (AC M = 3.90, SD = 1.23; NC M = 2.47, SD = 1.25; CC M = 3.32; SD = 1.34) and that their relationships with other track and field officials were strongly endorsed (M = 5.86, SD = 0.74). Bivariate correlations (Pearson r) indicated that perceived relatedness to other track and field officials demonstrated the strongest relationship with intention to continue officiating (r = .346, p < .05), while dimensions of OC were not significantly related to intention (all p's > .05). Together perceived relatedness (j3 = .339, p = .004), affective commitment (j3 = -.1 53, p = .308), normative commitment (j3 = -.024, p = .864) and continuance commitment (j3 = .186, P = .287) contribute to the prediction of intention to continued officiating (K = .139). These relationships remained unaffected by the inclusion of demographic (j3age = -.02; P years with Athletics Canada = -.13; bothp's > .05) or alternative commitment (j3sport = -.19; P role = .15; Pathletes = .20; all p' s > .05) considerations. Three open-ended questions elicited qualitative responses regarding participants' reasons for officiating. Responses reflecting initial reasons for officiating formed these higher order themes: convenience, helping reasons, extension of role, and intrinsic reasons. Responses reflecting reasons for continuing to officiate formed these higher order themes: track and field, to help, and personal benefits. Responses reflecting changes that would influence continued involvement were: political, organizational/structural, and personal. These results corroborate the findings of previous investigations which state that the reasons underpinning volunteer motivations change over time (Cuskelly et al., 2002). Overall, the results of this study suggest that track and field officials feel minimal commitment to the organization of Athletics Canada but a stronger bond with their fellow officials. Moreover, the degree to which track and field officials feel meaningfully connected to one another appears to exert a positive influence on their intentions to continue officiating. As such, it is suggested that in order to promote continued involvement, Athletics Canada increases its focus on fostering environments promoting positive interactions among officials.
Resumo:
This research was directed mainly towards the investigation of the reacti.ons of· substituted chlorobenziophenones under strongly basi,c conditions. The work 'can be divided into two main sections. The Introduction deals mainly with historical studies on aryne chemistry and the Haller-Bauer reaction. Secti.on I i.s concerned with syntheses of 2-benzamido-2'chlorobenzophenone and 2-benzamido~3'-chlorobenzophenone,and with thei,r respective reactions wi.th potassium amide in ammonia. o-Chlorophenylacetic acid was converted to the acid chloride and then by Friedel-Craftsreaction with benzene to w-(o-chlorophenyl)acetophenone. Reaction wi.th phenylhydrazine and Fischer cyclization gave 3- (0chlorophenyl)- 2-phenylindole, which was ozonized to 2-benzamido-2'chlorobenzophenone. The isomeric 3' -chlor,..o ke: tone was similarly synthesised from m-chlorophenylacetic acid. Both the 2'- and 3' -ch.loroketones gave N-benzoylacridone on treatment with potassium amide in ammonia; an aryne mechanism is involved for the 3'-chloroketone but aryne and nucleophilic substitution mechanisms are possible for the 2'-chloroketone. Hydrolysis of the 2'- and 3'-chloroketones gave 2-amino-2'chlorobenzophenone and 2-amino-3'-chlorobenzophenone respectively. A second new acridone synthesis is given in the Appendix involving reactions of these two ketones with potassium t-butoxide in t-butylbenzene. i Section 2 deals with the investigation of the reaction of some tricyclic ch1orobenzophenones with potassium amide in liquid ammonia. These were 1-ch1orof1uorenone; which was pr~pared in several steps from f1uoranthene, and 1- and 2-ch1oroanthraquinones. 1-Ch1orof1uorenone gave 1-aminof1uorenone ; 1-ch1oroanthraquinone gave 1- and 2-aminoanthraquinones; 2-ch1oroanthraquinone was largely recovered from the attempted reaction.
Resumo:
Nanoporous materials with large surface area and well-ordered pore structure have been synthesized. Thiol groups were grafted on the materials' surface to make heavy metal ion pre-concentration media. The adsorption properties ofthe materials were explored. Mercury, gold and silver can be strongly adsorbed by these materials, even in the presence of alkaline earth metal ion. Though the materials can adsorb other heavy metal ions such as lead and copper, they show differential adsorption ability when several ions are present in solution. The adsorption sequence is: mercury> == silver> copper » lead and cadmium. In the second part of this work, the memory effects of mercury, gold, silver and boron were investigated. The addition of 2% L-cysteine and 1% thiourea eliminates the problems of the three metal ions completely. The wash-out time for mercury dropped from more than 20 minutes to 18 seconds, and the wash-out time for gold decreased from more than 30 minutes to 49 seconds. The memory effect of boron can be reduced by the use of mannitol.
Resumo:
Part I: Ultra-trace determination of vanadium in lake sediments: a performance comparison using O2, N20, and NH3 as reaction gases in ICP-DRC-MS Thermal ion-molecule reactions, targeting removal of specific spectroscopic interference problems, have become a powerful tool for method development in quadrupole based inductively coupled plasma mass spectrometry (ICP-MS) applications. A study was conducted to develop an accurate method for the determination of vanadium in lake sediment samples by ICP-MS, coupled with a dynamic reaction cell (DRC), using two differenvchemical resolution strategies: a) direct removal of interfering C10+ and b) vanadium oxidation to VO+. The performance of three reaction gases that are suitable for handling vanadium interference in the dynamic reaction cell was systematically studied and evaluated: ammonia for C10+ removal and oxygen and nitrous oxide for oxidation. Although it was able to produce comparable results for vanadium to those using oxygen and nitrous oxide, NH3 did not completely eliminate a matrix effect, caused by the presence of chloride, and required large scale dilutions (and a concomitant increase in variance) when the sample and/or the digestion medium contained large amounts of chloride. Among the three candidate reaction gases at their optimized Eonditions, creation of VO+ with oxygen gas delivered the best analyte sensitivity and the lowest detection limit (2.7 ng L-1). Vanadium results obtained from fourteen lake sediment samples and a certified reference material (CRM031-040-1), using two different analytelinterference separation strategies, suggested that the vanadium mono-oxidation offers advantageous performance over the conventional method using NH3 for ultra-trace vanadium determination by ICP-DRC-MS and can be readily employed in relevant environmental chemistry applications that deal with ultra-trace contaminants.Part II: Validation of a modified oxidation approach for the quantification of total arsenic and selenium in complex environmental matrices Spectroscopic interference problems of arsenic and selenium in ICP-MS practices were investigated in detail. Preliminary literature review suggested that oxygen could serve as an effective candidate reaction gas for analysis of the two elements in dynamic reaction cell coupled ICP-MS. An accurate method was developed for the determination of As and Se in complex environmental samples, based on a series of modifications on an oxidation approach for As and Se previously reported. Rhodium was used as internal standard in this study to help minimize non-spectral interferences such as instrumental drift. Using an oxygen gas flow slightly higher than 0.5 mL min-I, arsenic is converted to 75 AS160+ ion in an efficient manner whereas a potentially interfering ion, 91Zr+, is completely removed. Instead of using the most abundant Se isotope, 80Se, selenium was determined by a second most abundant isotope, 78Se, in the form of 78Se160. Upon careful selection of oxygen gas flow rate and optimization ofRPq value, previous isobaric threats caused by Zr and Mo were reduced to background levels whereas another potential atomic isobar, 96Ru+, became completely harmless to the new selenium analyte. The new method underwent a strict validation procedure where the recovery of a suitable certified reference material was examined and the obtained sample data were compared with those produced by a credible external laboratory who analyzed the same set of samples using a standardized HG-ICP-AES method. The validation results were satisfactory. The resultant limits of detection for arsenic and selenium were 5 ng L-1 and 60 ng L-1, respectively.