4 resultados para Electronic data processing -- Quality control
em Brock University, Canada
Resumo:
One of the fundamental problems with image processing of petrographic thin sections is that the appearance (colour I intensity) of a mineral grain will vary with the orientation of the crystal lattice to the preferred direction of the polarizing filters on a petrographic microscope. This makes it very difficult to determine grain boundaries, grain orientation and mineral species from a single captured image. To overcome this problem, the Rotating Polarizer Stage was used to replace the fixed polarizer and analyzer on a standard petrographic microscope. The Rotating Polarizer Stage rotates the polarizers while the thin section remains stationary, allowing for better data gathering possibilities. Instead of capturing a single image of a thin section, six composite data sets are created by rotating the polarizers through 900 (or 1800 if quartz c-axes measurements need to be taken) in both plane and cross polarized light. The composite data sets can be viewed as separate images and consist of the average intensity image, the maximum intensity image, the minimum intensity image, the maximum position image, the minimum position image and the gradient image. The overall strategy used by the image processing system is to gather the composite data sets, determine the grain boundaries using the gradient image, classify the different mineral species present using the minimum and maximum intensity images and then perform measurements of grain shape and, where possible, partial crystallographic orientation using the maximum intensity and maximum position images.
Resumo:
This study examined nurses' attitudes toward computers before training and 2 months after training. A quantitative approach and a nonexperimental survey design were used in this study. Stronge and Brodt's (1985) instrument, Nurses' Attitudes Toward Computerization Questionnaire, was used to assess 27 nurses' attitudes prior to and 2 months after computer training. Demographic variables also were collected on the questionnaires. The results of this study showed that, overall, nurses had positive attitudes towards computers in both questionnaires. The results of the first questionnaire were consistent with other studies. There were no studies that involved a follow-up questionnaire using Stronge and Brodt's (1985) instrument. Attitude scores of Questionnaire 2 were higher than attitude scores of Questionnaire 1. More time for nursing tasks, less time for quality patient care, and threat to job security questions were found to be statistically significant. This study found no statistical significance between attitudes and demographic variables. Younger nurses a~d nurses with fewer years of computer experience were most likely to exhibit positive attitudes. Implications for practice and future research were discussed. Some limitations were identified and discussed.
Resumo:
A simple, low-cost concentric capillary nebulizer (CCN) was developed and evaluated for ICP spectrometry. The CCN could be operated at sample uptake rates of 0.050-1.00 ml min'^ and under oscillating and non-oscillating conditions. Aerosol characteristics for the CCN were studied using a laser Fraunhofter diffraction analyzer. Solvent transport efficiencies and transport rates, detection limits, and short- and long-term stabilities were evaluated for the CCN with a modified cyclonic spray chamber at different sample uptake rates. The Mg II (280.2nm)/l\/lg 1(285.2nm) ratio was used for matrix effect studies. Results were compared to those with conventional nebulizers, a cross-flow nebulizer with a Scott-type spray chamber, a GemCone nebulizer with a cyclonic spray chamber, and a Meinhard TR-30-K3 concentric nebulizer with a cyclonic spray chamber. Transport efficiencies of up to 57% were obtained for the CCN. For the elements tested, short- and long-term precisions and detection limits obtained with the CCN at 0.050-0.500 ml min'^ are similar to, or better than, those obtained on the same instrument using the conventional nebulizers (at 1.0 ml min'^). The depressive and enhancement effects of easily ionizable element Na, sulfuric acid, and dodecylamine surfactant on analyte signals with the CCN are similar to, or better than, those obtained with the conventional nebulizers. However, capillary clog was observed when the sample solution with high dissolved solids was nebulized for more than 40 min. The effects of data acquisition and data processing on detection limits were studied using inductively coupled plasma-atomic emission spectrometry. The study examined the effects of different detection limit approaches, the effects of data integration modes, the effects of regression modes, the effects of the standard concentration range and the number of standards, the effects of sample uptake rate, and the effect of Integration time. All the experiments followed the same protocols. Three detection limit approaches were examined, lUPAC method, the residual standard deviation (RSD), and the signal-to-background ratio and relative standard deviation of the background (SBR-RSDB). The study demonstrated that the different approaches, the integration modes, the regression methods, and the sample uptake rates can have an effect on detection limits. The study also showed that the different approaches give different detection limits and some methods (for example, RSD) are susceptible to the quality of calibration curves. Multicomponents spectral fitting (MSF) gave the best results among these three integration modes, peak height, peak area, and MSF. Weighted least squares method showed the ability to obtain better quality calibration curves. Although an effect of the number of standards on detection limits was not observed, multiple standards are recommended because they provide more reliable calibration curves. An increase of sample uptake rate and integration time could improve detection limits. However, an improvement with increased integration time on detection limits was not observed because the auto integration mode was used.
Resumo:
Health regulatory colleges promote quality practice and continued competence through Quality Assurance (QA) programs. For many colleges, a QA program includes the use of portfolios that incorporate self-directed learning. The purpose of this study was to determine some of the issues surrounding the effectiveness of QA portfolio programs. The literature review revealed that portfolios are valuable tools, but gaps in knowledge include a comparative analysis of QA programs and the perspective of regulatory college administrators. Data were collected through interviews with 6 administrators and a review of 14 portfolio models described on college websites. The results from the two data sources were applied to Robert Stake's responsive evaluation framework to identify issues related to the portfolio's effectiveness (Stake, 1967). The learning components of portfolios were analyzed through the humanist and constructivist lenses. All 14 portfolio models were found to have 3 main components: self-diagnosis, learning plan and activities, and self-evaluation. However, differences were uncovered in learners' autonomy in selecting learning activities, methods of portfolio evaluation, and the relationship between the portfolio and other QA components. The results revealed a dual philosophy of learning in portfolio models and an apparent contradiction between the needs of the individual learner and the organization. Paths for future research include the tenuous relationship between competence and learning, and the impact of technical approaches on selfdirected learning initiatives. A key recommendation is to acknowledge the unique identity of each profession so that health regulatory colleges can address legislative demands and learner needs.