98 resultados para Coupled map lattices
em Brock University, Canada
Resumo:
Master Plan Phase 2. Map of the original 1964 master plan showing the planned campus layout and distances from the centre of campus (ie. the Tower).
Resumo:
Master Plan Phase 2. This overhead map of the original 1964 Master Plan shows the planned campus layout along the escarpment.
Resumo:
This map shows the entire campus master plan and details what each area of land would be used for.
Resumo:
Note the land allocated for Brock University shaded in gray between Thorold and Grantham townships.
Resumo:
Phase 1 Map of the Master Plan showing the Tower and Thistle Complex, along with some additional buildings and the main parking lot. Note the location of the Central Utilities Building to the east differs from it's actual location along the escarpment.
Resumo:
Sediment relationships observed during geological mapping in southeastern Ontario indicate a relatively simple deglaciation history for the area during late Wisconsin time. The ice from the north (part of the Lake Simcoe lobe) and the Lake Ontario ice lobe, which were coalesced during most of late Wisconsin time, initially separated along the crest of the Oak Ridges Moraine. Available data indicate that the Oak Ridges Moraine is composed primarily of sediments pre-late Wisconsin in age capped by late Wisconsin till and interlobate deposits. Retreat of the northern ice was relatively steady and resulted in the deposition of the Dummer Moraines, a facies of the drumlinized till to the south. Retreat of the Lake Ontario ice lobe into the Lake Ontario basin was interrupted by a re-advance which covered the southeastern half of the map area. The northern ice had already retreated from the area by this time. The Lake Ontario lobe was fed through the St. Lawrence Valley, indicating that the Ottawa Valley was ice filled at this time. High level glacial lakes fronted the ice during deglaciation. These waters quickly fell to low levels as the ice retreated from the St. Lawrence Valley, opening lower outlets.
Resumo:
Arsenic, bismuth, germanium, antimony and tin were simultaneously determined by continuous hydride generation and inductively coupled plasma-atomic emission spectrometry . I Hydrides were introduced into four different types of gas-liquid separators. Two of the gas-liquid separators were available in-house. A third was developed for this project and a fourth was based on a design used by CET AC. The best signal intensity was achieved by the type II frit-based gas-liquid separator, but the modified Cetac design gave promise for the future, due to low relative standard deviation. A method was developed for the determination of arsenic, bismuth, antimony and tin in low-alloy steels. Four standard reference materials from NIST were dissolved in 10 mL aqua regia without heat. Good agreement was obtained between experimental values and certified values for arsenic, bismuth, antimony and tin. The method was developed to provide the analyst with the opportunity to determine the analytes by using simple aqueous standards to prepare calibration lines. Within the limits of the samples analyzed, the method developed is independent of matrix.
Resumo:
Monte Carlo Simulations were carried out using a nearest neighbour ferromagnetic XYmodel, on both 2-D and 3-D quasi-periodic lattices. In the case of 2-D, both the unfrustrated and frustrated XV-model were studied. For the unfrustrated 2-D XV-model, we have examined the magnetization, specific heat, linear susceptibility, helicity modulus and the derivative of the helicity modulus with respect to inverse temperature. The behaviour of all these quatities point to a Kosterlitz-Thouless transition occuring in temperature range Te == (1.0 -1.05) JlkB and with critical exponents that are consistent with previous results (obtained for crystalline lattices) . However, in the frustrated case, analysis of the spin glass susceptibility and EdwardsAnderson order parameter, in addition to the magnetization, specific heat and linear susceptibility, support a spin glass transition. In the case where the 'thin' rhombus is fully frustrated, a freezing transition occurs at Tf == 0.137 JlkB , which contradicts previous work suggesting the critical dimension of spin glasses to be de > 2 . In the 3-D systems, examination of the magnetization, specific heat and linear susceptibility reveal a conventional second order phase transition. Through a cumulant analysis and finite size scaling, a critical temperature of Te == (2.292 ± 0.003) JI kB and critical exponents of 0:' == 0.03 ± 0.03, f3 == 0.30 ± 0.01 and I == 1.31 ± 0.02 have been obtained.
Resumo:
A simple, low-cost concentric capillary nebulizer (CCN) was developed and evaluated for ICP spectrometry. The CCN could be operated at sample uptake rates of 0.050-1.00 ml min'^ and under oscillating and non-oscillating conditions. Aerosol characteristics for the CCN were studied using a laser Fraunhofter diffraction analyzer. Solvent transport efficiencies and transport rates, detection limits, and short- and long-term stabilities were evaluated for the CCN with a modified cyclonic spray chamber at different sample uptake rates. The Mg II (280.2nm)/l\/lg 1(285.2nm) ratio was used for matrix effect studies. Results were compared to those with conventional nebulizers, a cross-flow nebulizer with a Scott-type spray chamber, a GemCone nebulizer with a cyclonic spray chamber, and a Meinhard TR-30-K3 concentric nebulizer with a cyclonic spray chamber. Transport efficiencies of up to 57% were obtained for the CCN. For the elements tested, short- and long-term precisions and detection limits obtained with the CCN at 0.050-0.500 ml min'^ are similar to, or better than, those obtained on the same instrument using the conventional nebulizers (at 1.0 ml min'^). The depressive and enhancement effects of easily ionizable element Na, sulfuric acid, and dodecylamine surfactant on analyte signals with the CCN are similar to, or better than, those obtained with the conventional nebulizers. However, capillary clog was observed when the sample solution with high dissolved solids was nebulized for more than 40 min. The effects of data acquisition and data processing on detection limits were studied using inductively coupled plasma-atomic emission spectrometry. The study examined the effects of different detection limit approaches, the effects of data integration modes, the effects of regression modes, the effects of the standard concentration range and the number of standards, the effects of sample uptake rate, and the effect of Integration time. All the experiments followed the same protocols. Three detection limit approaches were examined, lUPAC method, the residual standard deviation (RSD), and the signal-to-background ratio and relative standard deviation of the background (SBR-RSDB). The study demonstrated that the different approaches, the integration modes, the regression methods, and the sample uptake rates can have an effect on detection limits. The study also showed that the different approaches give different detection limits and some methods (for example, RSD) are susceptible to the quality of calibration curves. Multicomponents spectral fitting (MSF) gave the best results among these three integration modes, peak height, peak area, and MSF. Weighted least squares method showed the ability to obtain better quality calibration curves. Although an effect of the number of standards on detection limits was not observed, multiple standards are recommended because they provide more reliable calibration curves. An increase of sample uptake rate and integration time could improve detection limits. However, an improvement with increased integration time on detection limits was not observed because the auto integration mode was used.
Resumo:
Cover title.
Resumo:
Title vignette.
Resumo:
Survey map of the Second Welland Canal created by the Welland Canal Company showing the areas in and around Port Dalhousie and Grantham Township. Identified structures associated with the Canal include Lock 1, Lighthouse, Lighthouse Keeper's House, East and West Piers, Harbour, Waste Weir, Store House, Collector's Office, Collector Assistant Office, Lock Tender's House and the new towing path. Features of the First Welland Canal are noted in red ink and includes the old Harbour, old Lock 1, old towing path and the original bed of the Twelve Mile Creek. The surveyors' measurements and notes can be seen in red and black ink and pencil. Local area landmarks and businesses are also identified and include streets and roads (ex. Lock Street and Colonel Clark's Cattle Road), Alex Muir's Dry Dock, RandJ Laurie Flouring Mill, R. Laurie and Company Grist Mill, A. Morrison Saw Mill, Johnson's Tavern, a store and a church. Properties and property owners of note are: Concession 1 Lots 21 and 22, John Christie, John Clark, N. Pawling, William Pawling, W. Carter, G.A. Clark, J. Maven, Mrs. Wood, James Drabble and J. Woodall.
Resumo:
Survey map of the Second Welland Canal created by the Welland Canal Company showing the areas in and around Port Dalhousie and Grantham Township. Identified structures associated with the Canal include Lock 1, East and West Piers, Collector's Office, Lock Tender's House and the new towing path. The surveyors' measurements and notes can be seen in red and black ink and pencil. Local area landmarks and businesses are also identified and include streets and roads (ex. Road to St. Catharines, Side Line, Old Road to Port Dalhousie, Road to Niagara), the Welland Railway and its structures (ex. freight sheds, wood shed, raised platform, elevator, cranes, water tank, turn table, and passenger station), G. A. Clark's Wood Yard, Clark's Wood Office, Alex Muir's Dry Dock, Donald, Andrews and Ross' Dry Dock, RandJ Laurie Flouring Mill, R. Laurie and Company Grist Mill and A. Morrison Saw Mill. A New Road to St. Catharines is featured in red ink. Properties and property owners of note are: Concession 1 Lots 19, 20 and 21, John Christie, and John Clark.