10 resultados para Caesium 137, standard deviation

em Brock University, Canada


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this correlational study was to investigate the relationship between the degree of self-directed learning readiness and stress for level one nursing students and level two nursing students. One hundred female nursing students participated in the study who were attending an Ontario Community College. Data were collected from the main nursing campus and the satellite nursing campus using the random sample method. Instruments used were said to be valid and reliable for testing self-directed learning readiness and stress respectively. Data were analyzed using frequency response to each item, means and standard deviation, and the Pearson product correlation between selfdirected learning readiness and stress. The results of the study show that there is a difference in the relationship between the degree of self-directed learning readiness and stress between the level one nursing students and the level two nursing students. Such results will be of particular interest to nursing instructors and administrators when planning for delivery of programs to such students.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Modifications to the commercial hydride generator, manufactured by Spectrametrics, resulted in improved operating procedure and enhancement of the arsenic and germanium signals. Experiments with arsenic(III) and arsenic(V) showed that identical reiults could be produced from both oxidation states. However, since arsenic(V) is reduced more slowly than arsenic(III), peak areas and not peak heights must be measured when the arsine is immediately stripped from the system (approximately 5 seconds reaction). When the reduction is allowed to proceed for 20 seconds before the arsine is stripped, peak heights may be used. For a 200 ng/mL solution, the relative standard deviation is 2.8% for As(III) and 3.8% for As(V). The detection limit for arsenic using the modified system is 0.50 ng/mL. Studies performed on As(V) standards show that the interferences from 1000 mg/L of nickel(II), cobalt(II), iron(III), copper(II), cadmium(II), and zinc(II) can be eliminated with the aid of 5 M Hel and 3% L-cystine. Conditions for the reduction of germanium to the corresponding hydride were investigated. The effect of different concentrations of HCl on the reduction of germanium to the covalent hydride in aqueous media by means of NaBH 4 solutions was assessed. Results show that the best response is accomplished at a pH of 1.7. The use of buffer solutions was similarly characterized. In both cases, results showed that the element is best reduced when the final pH of the solution after reaction is almost neutral. In addition, a more sensitive method, which includes the use of (NH4)2S208' has been developed. A 20% increase in the germanium signal is registered when compared to the signal achieved with Hel alone. Moreover, under these conditions, reduction of germanium could be accomplished, even when the solution's pH is neutral. For a 100 ng/mL germanium standard the rsd is 3%. The detection limit for germanium in 0.05 M Hel medium (pH 1.7) is 0.10 ng/mL and 0.09 ng/mL when ammonium persulphate is used in conjunction with Hel. Interferences from 1000 mg/L of iron(III), copper(II), cobalt(II), nickel(II), cadmium(II), lead(II), mercury(II), aluminum(III), tin(IV), arsenic(III), arsenic(V) and zinc(II) were studied and characterized. In this regard, the use of (NH4)ZS20S and Hel at a pH of 1.7 proved to be a successful mixture in the sbppression of the interferences caused by iron, copper, aluminum, tin, lead, and arsenic. The method was applied to the determination of germanium in cherts and iron ores. In addition, experiments with tin(IV) showed that a 15% increase in the tin signal can be accomplished in the presence of 1 mL of (NH4)2S20S 10% (m/V).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A method using L-cysteine for the determination of arsenous acid (As(III)), arsenic acid (As(V)), monomethylarsonic acid (MMAA), and dimethylarsinic acid (DMAA) by hydride generation was demonstrated. The instrument used was a d.c. plasma atomic emission spectrometer (OCP-AES). Complete recovery was reported for As(III), As(V), and DMAA while 86% recovery was reported for MMAA. Detection limits were determined, as arsenic for the species listed previously, to be 1.2, 0.8, 1.1, and 1.0 ngemL-l, respectively. Precision values, at 50 ngemL-1 arsenic concentration, were f.80/0, 2.50/0, 2.6% and 2.6% relative standard deviation, respectively. The L-cysteine reagent was compared directly with the conventional hydride generation technique which uses a potassium iodide-hydrochloric acid medium. Recoveries using L-cysteine when compared with the conventional method provided the following results: similar recoveries were obtained for As(III), slightly better recoveries were obtained for As(V) and MMAA, and significantly better recoveries for DMAA. In addition, tall and sharp peak shapes were observed for all four species when using L-cysteine. The arsenic speciation method involved separation by ion exchange .. high perfonnance liquid chromatography (HPLC) with on-line hydride generation using the L.. cysteine reagent and measurement byOCP-AES. Total analysis time per sample was 12 min while the time between the start of subsequent runs was approximately 20 min. A binary . gradient elution program, which incorporated the following two eluents: 0.01 and 0.5 mM tri.. sodium citrate both containing 5% methanol (v/v) and both at a pH of approximately 9, was used during the separation by HPLC. Recoveries of the four species which were measured as peak area, and were normalized against As(III), were 880/0, 290/0, and 40% for DMAA, MMAA and As(V), respectively. Resolution factors between adjacent analyte peaks of As(III) and DMAA was 1.1; DMAA and MMAA was 1.3; and MMAA and As(V) was 8.6. During the arsenic speciation study, signals from the d.c. plasma optical system were measured using a new photon-signal integrating device. The_new photon integrator developed and built in this laboratory was based on a previously published design which was further modified to reflect current available hardware. This photon integrator was interfaced to a personal computer through an AID convertor. The .photon integrator has adjustable threshold settings and an adjustable post-gain device.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Arsenic, bismuth, germanium, antimony and tin were simultaneously determined by continuous hydride generation and inductively coupled plasma-atomic emission spectrometry . I Hydrides were introduced into four different types of gas-liquid separators. Two of the gas-liquid separators were available in-house. A third was developed for this project and a fourth was based on a design used by CET AC. The best signal intensity was achieved by the type II frit-based gas-liquid separator, but the modified Cetac design gave promise for the future, due to low relative standard deviation. A method was developed for the determination of arsenic, bismuth, antimony and tin in low-alloy steels. Four standard reference materials from NIST were dissolved in 10 mL aqua regia without heat. Good agreement was obtained between experimental values and certified values for arsenic, bismuth, antimony and tin. The method was developed to provide the analyst with the opportunity to determine the analytes by using simple aqueous standards to prepare calibration lines. Within the limits of the samples analyzed, the method developed is independent of matrix.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Female choice is an important element of sexual selection that may vary among females of the same species. Few researchers have investigated the causes of variation in selectivity with respect to potential mates and overall level of motivation toward a stimulus source representative of a mate. This study demonstrates that female age may be one cause of variation in female choice. Females of different ages may have different mate preferences. As females age, they have less time left to reproduce, and their residual reproductive value decreases. This should correspond to a higher reproductive effort which may be represented as increased motivation and/or decreased selectivity. The effect of age on mate choice in Gryllus integer was investigated by using a non-compensating treadmill, called the Kugel, to measure female phonotaxis. Artificially generated male calling songs of varying pulse rates were broadcast in either a singlestimulus or a three-stimulus experimental design. The pulse rates used in the calling song stimuli were 70, 64, 76, 55 and 85 pulses per second. These corresponded to the documented mean pulse rate for the species at the experimental temperature, one standard deviation below and above the mean, and 2.5 standard deviations below and above the mean, respectively. Test females were either 11-14 days or 25-28 days post-ecdysis. Trials usually were conducted two to seven hours into the scotophase. In the single-stimulus experiment, females were presented with stimuli with only one pulse rate. Older females achieved higher vector scores than younger females, indicating that older females are more motivated to mate. Both groups showed little phonotactic response towards 55 or 85 pIs, both of which lie outside the natural range of G. integer calling song at the experimental temperature. Neither group discriminated among the three pulse rates that fell within the natural range of calling song. In the three-stimulus experiment, females were presented with stimuli with one of three pulse rates, 64, 70 or 76 pIs, In alternation. Both age groups had reduced responsiveness in this experiment, perhaps due to an increase in perceived male density. Additionally, younger females responded significantly more to 64 and 70 pIs than to the higher pulse rate, indicating that they are selective with respect to mate choice. Older females did not discriminate among the three pulse rates. Therefore, it was concluded that selectivity decreases with age. A further study was conducted to determine that these effects were due to age and not due to the differing periods without a mating between the two age groups. Again, stimuli were presented in a three-stimulus experimental design. Age was held constant at 28 days and time since last mating varied from 11 to 25 days. Females varyIng in time since last mating did not differ in their responses to the calling song pulse rates. This indicated that the increased motivation and decreased selectivity exhibited In the initial experiments were due to age and not to time without a mating. Neither time of trial nor female weight had an effect upon female phonotaxis. Data are discussed in terms of mate choice, residual reproductive value, and costs of choice.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Improvements have been made on the currently available hydride generator system manufactured by SpectraMetrics Incorporated, because the system was found to be unsatisfactory with respect to the following: 1. the drying agent, anhydrous calcium chloride, 2. the special sample tube, 3. the direction of argon flow through the Buchner funnel when it came to dealing with real sample, that is, with reference only to aqueous extracts of soil samples. Changes that were made on the system included the replacement of anhydrous calcium chloride with anhydrous calcium sulphate and the replacement of the special sample tube with a modified one made from silica. Re-directing the flow of argon through the top of the Buchner funnel appeared to make the system compatible with aqueous extracts of soil samples. The interferences from 1000 ~g/mL of nickel(II) , cobalt(II), iron(III), copper(II) have been eliminated with the aid of 1.4 M hydrochloric acid and 1% (weight/volume) L-cystine. Greater than 90% recovery of 0.3 ~g/mL arsenic signal was achieved in each case. Furthermore, 103% of arsenic signal was accomplished in the presence of 1000 ~g/mL cadmium with 5 M Hel. tVhen each of the interferents was present in solution at 1000 ppm, a recovery of 85% was achieved by using 5 M hydrochloric acid and 3% (weight/volume) L-cystine. Without L-cystine and when 1.4 M hydrochloric acid was used, the recoveries were 0% (Ni), 0% (Co), 88% (Fe), 15% (Cu), 18% (Cd). Similarly, a solution containing 1000 ppm of each interferent gave a zero percent recovery of arsenic. The reduction of trivalent and pentavalent arsenic at a pH less than one has also been investigated and shown to be quantitative if peak areas are measured. The reproducibility determination of a 0.3 Vg/mL standard arsenic solution by hydride generation shows a relative standard deviation of 3.4%. The detection limits with and without Porapak Q have been found to be 0.6 ng/mL and 1.0 ng/mL, respectively.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study examined adolescents' reported sexual and dietary health-risk behaviours and perceptions. Specifically, this study analyzed the data of 600 students (300 male~ 300 female) in grades 9, I 1, and OAC (mean, standard deviation). The mean age of the students in the sample is 16 with a standard deviation of 1.6. The study was a secondary analysis ofthe first-year data of a 3-year longitudinal study conducted by Youth Lifestyle Choices-Community University Research Alliance (YLC-CURA) on adolescents. To explore sexuality and dietary health, this study purposefully selected sections of the survey that represented sex and dieting behaviours of adolescents. Separate gender and age data analyses revealed different patterns among the variables. Specifically., findings revealed that adolescents who engaged in recent sexual activities were more likely to have a relatively more positive body image perception and were relatively more likely to engage in disordered eating. Across both genders and 3 age levels, adolescents reported that despite their unhealthy dietary habits they felt that dieting was not a high-risk behaviour. Results were discussed in terms of educational implication for sexual health programs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The study focused on the teacher as an adult learner rather than an instructor. A sample of three hundred and three elementary school teachers completed a two-part Likert survey questionnaire. The instrument was developed by the researcher in an attempt to operationalize Mezirow's Theory of Perspective Transformation. The four sub-scales collected information about teachers as they perceived themselves as adult learners and the way they conceptualize critical SelfReflection, Meaning perspectives and New Insights (Mezirow, 1978, 1981, 1989, 1990) within a framework of Mezirow's concept of Transformative Learning. Survey research methodology was used. Frequency distributions, means, and standard deviation were calculated. Reliability analysis and Pearson 'r' correlations established the internal consistency of items It Cross tabulations to describe differences in responses across demographic valuables were computed. The survey results indicated that teachers perceived themselves as self-directed learners. The findings support the need for a better understanding of the teacher as an adult learner so that teacher inservice programs and teacher supervision and evaluation can provide a viable learning alternative to the existing models used in practice.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple, low-cost concentric capillary nebulizer (CCN) was developed and evaluated for ICP spectrometry. The CCN could be operated at sample uptake rates of 0.050-1.00 ml min'^ and under oscillating and non-oscillating conditions. Aerosol characteristics for the CCN were studied using a laser Fraunhofter diffraction analyzer. Solvent transport efficiencies and transport rates, detection limits, and short- and long-term stabilities were evaluated for the CCN with a modified cyclonic spray chamber at different sample uptake rates. The Mg II (280.2nm)/l\/lg 1(285.2nm) ratio was used for matrix effect studies. Results were compared to those with conventional nebulizers, a cross-flow nebulizer with a Scott-type spray chamber, a GemCone nebulizer with a cyclonic spray chamber, and a Meinhard TR-30-K3 concentric nebulizer with a cyclonic spray chamber. Transport efficiencies of up to 57% were obtained for the CCN. For the elements tested, short- and long-term precisions and detection limits obtained with the CCN at 0.050-0.500 ml min'^ are similar to, or better than, those obtained on the same instrument using the conventional nebulizers (at 1.0 ml min'^). The depressive and enhancement effects of easily ionizable element Na, sulfuric acid, and dodecylamine surfactant on analyte signals with the CCN are similar to, or better than, those obtained with the conventional nebulizers. However, capillary clog was observed when the sample solution with high dissolved solids was nebulized for more than 40 min. The effects of data acquisition and data processing on detection limits were studied using inductively coupled plasma-atomic emission spectrometry. The study examined the effects of different detection limit approaches, the effects of data integration modes, the effects of regression modes, the effects of the standard concentration range and the number of standards, the effects of sample uptake rate, and the effect of Integration time. All the experiments followed the same protocols. Three detection limit approaches were examined, lUPAC method, the residual standard deviation (RSD), and the signal-to-background ratio and relative standard deviation of the background (SBR-RSDB). The study demonstrated that the different approaches, the integration modes, the regression methods, and the sample uptake rates can have an effect on detection limits. The study also showed that the different approaches give different detection limits and some methods (for example, RSD) are susceptible to the quality of calibration curves. Multicomponents spectral fitting (MSF) gave the best results among these three integration modes, peak height, peak area, and MSF. Weighted least squares method showed the ability to obtain better quality calibration curves. Although an effect of the number of standards on detection limits was not observed, multiple standards are recommended because they provide more reliable calibration curves. An increase of sample uptake rate and integration time could improve detection limits. However, an improvement with increased integration time on detection limits was not observed because the auto integration mode was used.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Flow injection analysis (FIA) was applied to the determination of both chloride ion and mercury in water. Conventional FIA was employed for the chloride study. Investigations of the Fe3 +/Hg(SCN)2/CI-,450 nm spectrophotometric system for chloride determination led to the discovery of an absorbance in the 250-260 nm region when Hg(SCN)2 and CI- are combined in solution, in the absence of iron(III). Employing an in-house FIA system, absorbance observed at 254 nm exhibited a linear relation from essentially 0 - 2000 Jlg ml- 1 injected chloride. This linear range spanning three orders of magnitude is superior to the Fe3+/Hg(SCN)2/CI- system currently employed by laboratories worldwide. The detection limit obtainable with the proposed method was determin~d to be 0.16 Jlg ml- 1 and the relative standard deviation was determined to be 3.5 % over the concentration range of 0-200 Jig ml- 1. Other halogen ions were found to interfere with chloride determination at 254 nm whereas cations did not interfere. This system was successfully applied to the determination of chloride ion in laboratory water. Sequential injection (SI)-FIA was employed for mercury determination in water with the PSA Galahad mercury amalgamation, and Merlin mercury fluorescence detection systems. Initial mercury in air determinations involved injections of mercury saturated air directly into the Galahad whereas mercury in water determinations involved solution delivery via peristaltic pump to a gas/liquid separator, after reduction by stannous chloride. A series of changes were made to the internal hardware and valving systems of the Galahad mercury preconcentrator. Sequential injection solution delivery replaced the continuous peristaltic pump system and computer control was implemented to control and integrate all aspects of solution delivery, sample preconcentration and signal processing. Detection limits currently obtainable with this system are 0.1 ng ml-1 HgO.