5 resultados para Automatic Data Processing

em Brock University, Canada


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This thesis describes research in which genetic programming is used to automatically evolve shape grammars that construct three dimensional models of possible external building architectures. A completely automated fitness function is used, which evaluates the three dimensional building models according to different geometric properties such as surface normals, height, building footprint, and more. In order to evaluate the buildings on the different criteria, a multi-objective fitness function is used. The results obtained from the automated system were successful in satisfying the multiple objective criteria as well as creating interesting and unique designs that a human-aided system might not discover. In this study of evolutionary design, the architectures created are not meant to be fully functional and structurally sound blueprints for constructing a building, but are meant to be inspirational ideas for possible architectural designs. The evolved models are applicable for today's architectural industries as well as in the video game and movie industries. Many new avenues for future work have also been discovered and highlighted.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

One of the fundamental problems with image processing of petrographic thin sections is that the appearance (colour I intensity) of a mineral grain will vary with the orientation of the crystal lattice to the preferred direction of the polarizing filters on a petrographic microscope. This makes it very difficult to determine grain boundaries, grain orientation and mineral species from a single captured image. To overcome this problem, the Rotating Polarizer Stage was used to replace the fixed polarizer and analyzer on a standard petrographic microscope. The Rotating Polarizer Stage rotates the polarizers while the thin section remains stationary, allowing for better data gathering possibilities. Instead of capturing a single image of a thin section, six composite data sets are created by rotating the polarizers through 900 (or 1800 if quartz c-axes measurements need to be taken) in both plane and cross polarized light. The composite data sets can be viewed as separate images and consist of the average intensity image, the maximum intensity image, the minimum intensity image, the maximum position image, the minimum position image and the gradient image. The overall strategy used by the image processing system is to gather the composite data sets, determine the grain boundaries using the gradient image, classify the different mineral species present using the minimum and maximum intensity images and then perform measurements of grain shape and, where possible, partial crystallographic orientation using the maximum intensity and maximum position images.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This case study examines the impact of a computer information system as it was being implemented in one Ontario hospital. The attitudes of a cross section of the hospital staff acted as a barometer to measure their perceptions of the implementation process. With The Mississauga Hospital in the early stages of an extensive computer implementation project, the opportunity existed to identify staff attitudes about the computer system, overall knowledge and compare the findings with the literature. The goal of the study was to develop a greater base about the affective domain in the relationship between people and the computer system. Eight exploratory questions shaped the focus of the investigation. Data were collected from three sources: a survey questionnaire, focused interviews, and internal hospital documents. Both quantitative and qualitative data were analyzed. Instrumentation in the study consisted of a survey distributed at two points in time to randomly selected hospital employees who represented all staff levels.Other sources of data included hospital documents, and twenty-five focused interviews with staff who replied to both surveys. Leavitt's socio-technical system, with its four subsystems: task, structure, technology, and people was used to classify staff responses to the research questions. The study findings revealed that the majority of respondents felt positive about using the computer as part of their jobs. No apparent correlations were found between sex, age, or staff group and feelings about using the computer. Differences in attitudes, and attitude changes were found in potential relationship to the element of time. Another difference was found in staff group and perception of being involved in the decision making process. These findings and other evidence about the role of change agents in this change process help to emphasize that planning change is one thing, managing the transition is another.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This study examined nurses' attitudes toward computers before training and 2 months after training. A quantitative approach and a nonexperimental survey design were used in this study. Stronge and Brodt's (1985) instrument, Nurses' Attitudes Toward Computerization Questionnaire, was used to assess 27 nurses' attitudes prior to and 2 months after computer training. Demographic variables also were collected on the questionnaires. The results of this study showed that, overall, nurses had positive attitudes towards computers in both questionnaires. The results of the first questionnaire were consistent with other studies. There were no studies that involved a follow-up questionnaire using Stronge and Brodt's (1985) instrument. Attitude scores of Questionnaire 2 were higher than attitude scores of Questionnaire 1. More time for nursing tasks, less time for quality patient care, and threat to job security questions were found to be statistically significant. This study found no statistical significance between attitudes and demographic variables. Younger nurses a~d nurses with fewer years of computer experience were most likely to exhibit positive attitudes. Implications for practice and future research were discussed. Some limitations were identified and discussed.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A simple, low-cost concentric capillary nebulizer (CCN) was developed and evaluated for ICP spectrometry. The CCN could be operated at sample uptake rates of 0.050-1.00 ml min'^ and under oscillating and non-oscillating conditions. Aerosol characteristics for the CCN were studied using a laser Fraunhofter diffraction analyzer. Solvent transport efficiencies and transport rates, detection limits, and short- and long-term stabilities were evaluated for the CCN with a modified cyclonic spray chamber at different sample uptake rates. The Mg II (280.2nm)/l\/lg 1(285.2nm) ratio was used for matrix effect studies. Results were compared to those with conventional nebulizers, a cross-flow nebulizer with a Scott-type spray chamber, a GemCone nebulizer with a cyclonic spray chamber, and a Meinhard TR-30-K3 concentric nebulizer with a cyclonic spray chamber. Transport efficiencies of up to 57% were obtained for the CCN. For the elements tested, short- and long-term precisions and detection limits obtained with the CCN at 0.050-0.500 ml min'^ are similar to, or better than, those obtained on the same instrument using the conventional nebulizers (at 1.0 ml min'^). The depressive and enhancement effects of easily ionizable element Na, sulfuric acid, and dodecylamine surfactant on analyte signals with the CCN are similar to, or better than, those obtained with the conventional nebulizers. However, capillary clog was observed when the sample solution with high dissolved solids was nebulized for more than 40 min. The effects of data acquisition and data processing on detection limits were studied using inductively coupled plasma-atomic emission spectrometry. The study examined the effects of different detection limit approaches, the effects of data integration modes, the effects of regression modes, the effects of the standard concentration range and the number of standards, the effects of sample uptake rate, and the effect of Integration time. All the experiments followed the same protocols. Three detection limit approaches were examined, lUPAC method, the residual standard deviation (RSD), and the signal-to-background ratio and relative standard deviation of the background (SBR-RSDB). The study demonstrated that the different approaches, the integration modes, the regression methods, and the sample uptake rates can have an effect on detection limits. The study also showed that the different approaches give different detection limits and some methods (for example, RSD) are susceptible to the quality of calibration curves. Multicomponents spectral fitting (MSF) gave the best results among these three integration modes, peak height, peak area, and MSF. Weighted least squares method showed the ability to obtain better quality calibration curves. Although an effect of the number of standards on detection limits was not observed, multiple standards are recommended because they provide more reliable calibration curves. An increase of sample uptake rate and integration time could improve detection limits. However, an improvement with increased integration time on detection limits was not observed because the auto integration mode was used.