3 resultados para stent coronariano

em Doria (National Library of Finland DSpace Services) - National Library of Finland, Finland


Relevância:

20.00% 20.00%

Publicador:

Resumo:

University of Turku, Faculty of Medicine, Department of Cardiology and Cardiovascular Medicine, Doctoral Programme of Clinical Investigation, Heart Center, Turku University Hospital, Turku, Finland Division of Internal Medicine, Department of Cardiology, Seinäjoki Central Hospital, Seinäjoki, Finland Heart Center, Satakunta Central Hospital, Pori, Finland Annales Universitatis Turkuensis Painosalama Oy, Turku, Finland 2015 Antithrombotic therapy during and after coronary procedures always entails the challenging establishment of a balance between bleeding and thrombotic complications. It has been generally recommended to patients on long-term warfarin therapy to discontinue warfarin a few days prior to elective coronary angiography or intervention to prevent bleeding complications. Bridging therapy with heparin is recommended for patients at an increased risk of thromboembolism who require the interruption of anticoagulation for elective surgery or an invasive procedure. In study I, consecutive patients on warfarin therapy referred for diagnostic coronary angiography were compared to control patients with a similar disease presentation without warfarin. The strategy of performing coronary angiography during uninterrupted therapeutic warfarin anticoagulation appeared to be a relatively safe alternative to bridging therapy, if the international normalized ratio level was not on a supratherapeutic level. In-stent restenosis remains an important reason for failure of long-term success after a percutaneous coronary intervention (PCI). Drug-eluting stents (DES) reduce the problem of restenosis inherent to bare metal stents (BMS). However, a longer delay in arterial healing may extend the risk of stent thrombosis (ST) far beyond 30 days after the DES implantation. Early discontinuation of antiplatelet therapy has been the most important predisposing factor for ST. In study II, patients on long-term oral anticoagulant (OAC) underwent DES or BMS stenting with a median of 3.5 years’follow-up. The selective use of DESs with a short triple therapy seemed to be safe in OAC patients, since late STs were rare even without long clopidogrel treatment. Major bleeding and cardiac events were common in this patient group irrespective of stent type. In order to help to predict the bleeding risk in patients on OAC, several different bleeding risk scorings have been developed. Risk scoring systems have also been used also in the setting of patients undergoing a PCI. In study III, the predictive value of an outpatient bleeding risk index (OBRI) to identify patients at high risk of bleeding was analysed. The bleeding risk seemed not to modify periprocedural or long-term treatment choices in patients on OAC after a percutaneous coronary intervention. Patients with a high OBRI often had major bleeding episodes, and the OBRI may be suitable for risk evaluation in this patient group. Optical coherence tomography (OCT) is a novel technology for imaging intravascular coronary arteries. OCT is a light-based imaging modality that enables a 12–18 µm tissue axial resolution to visualize plaques in the vessel, possible dissections and thrombi as well as, stent strut appositions and coverage, and to measure the vessel lumen and lesions. In study IV, 30 days after titanium-nitride-oxide (TITANOX)-coated stent implantation, the binary stent strut coverage was satisfactory and the prevalence of malapposed struts was low as evaluated by OCT. Long-term clinical events in patients treated with (TITANOX)-coated bio-active stents (BAS) and paclitaxel-eluting stents (PES) in routine clinical practice were examined in study V. At the 3-year follow-up, BAS resulted in better long-term outcome when compared with PES with an infrequent need for target vessel revascularization. Keywords: anticoagulation, restenosis, thrombosis, bleeding, optical coherence tomography, titanium

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Deep cannulation is a prerequisite for successful endoscopic retrograde cholangiopancreatography (ERCP) procedures. Of the biliary procedures, stenting is one of the most common. This study was carried out to investigate current and controversial issues regarding biliary cannulation and stenting. The double guidewire (DGW) technique was studied to analyze its safety and feasibility in biliary cannulation as a single procedure and as a part of the novel three-step cannulation protocol. Female gender was evaluated in regard to difficult cannulation. The use of an angled and a straight tipped guidewire in biliary cannulation was studied in a prospective, randomized trial. Additionally, the patency of the novel antireflux plastic biliary stent was compared to the patency of the conventional plastic biliary stent in a prospective, randomized setting. The DGW method seems safe and feasible as an alternative cannulation technique in biliary cannulation. Female gender was not associated significantly with difficult biliary cannulation in our study, although the cannulation times seemed to be longer and the alternative cannulation techniques seemed to be needed more often in females than males. According to the results of this thesis, an angled tipped guidewire may facilitate biliary cannulation. In controversy to the previous result presented in the literature, the antireflux plastic biliary stent tested herein should not be used, as the patency of the stent was significantly shorter compared to the conventional plastic stent.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The application of computational fluid dynamics (CFD) and finite element analysis (FEA) has been growing rapidly in the various fields of science and technology. One of the areas of interest is in biomedical engineering. The altered hemodynamics inside the blood vessels plays a key role in the development of the arterial disease called atherosclerosis, which is the major cause of human death worldwide. Atherosclerosis is often treated with the stenting procedure to restore the normal blood flow. A stent is a tubular, flexible structure, usually made of metals, which is driven and expanded in the blocked arteries. Despite the success rate of the stenting procedure, it is often associated with the restenosis (re-narrowing of the artery) process. The presence of non-biological device in the artery causes inflammation or re-growth of atherosclerotic lesions in the treated vessels. Several factors including the design of stents, type of stent expansion, expansion pressure, morphology and composition of vessel wall influence the restenosis process. Therefore, the role of computational studies is crucial in the investigation and optimisation of the factors that influence post-stenting complications. This thesis focuses on the stent-vessel wall interactions followed by the blood flow in the post-stenting stage of stenosed human coronary artery. Hemodynamic and mechanical stresses were analysed in three separate stent-plaque-artery models. Plaque was modeled as a multi-layer (fibrous cap (FC), necrotic core (NC), and fibrosis (F)) and the arterial wall as a single layer domain. CFD/FEA simulations were performed using commercial software packages in several models mimicking the various stages and morphologies of atherosclerosis. The tissue prolapse (TP) of stented vessel wall, the distribution of von Mises stress (VMS) inside various layers of vessel wall, and the wall shear stress (WSS) along the luminal surface of the deformed vessel wall were measured and evaluated. The results revealed the role of the stenosis size, thickness of each layer of atherosclerotic wall, thickness of stent strut, pressure applied for stenosis expansion, and the flow condition in the distribution of stresses. The thicknesses of FC, and NC and the total thickness of plaque are critical in controlling the stresses inside the tissue. A small change in morphology of artery wall can significantly affect the distribution of stresses. In particular, FC is the most sensitive layer to TP and stresses, which could determine plaque’s vulnerability to rupture. The WSS is highly influenced by the deflection of artery, which in turn is dependent on the structural composition of arterial wall layers. Together with the stenosis size, their roles could play a decisive role in controlling the low values of WSS (<0.5 Pa) prone to restenosis. Moreover, the time dependent flow altered the percentage of luminal area with WSS values less than 0.5 Pa at different time instants. The non- Newtonian viscosity model of the blood properties significantly affects the prediction of WSS magnitude. The outcomes of this investigation will help to better understand the roles of the individual layers of atherosclerotic vessels and their risk to provoke restenosis at the post-stenting stage. As a consequence, the implementation of such an approach to assess the post-stented stresses will assist the engineers and clinicians in optimizing the stenting techniques to minimize the occurrence of restenosis.