28 resultados para side-pump
em Doria (National Library of Finland DSpace Services) - National Library of Finland, Finland
Resumo:
Selostus: Yrttien ja vihannesten infrapunakuivaus rumpukuivurissa
Resumo:
The integrated system of design for manufacturing and assembly (DFMA) and internet based collaborative design are presented to support product design, manufacturing process, and assembly planning for axial eccentric oil-pump design. The presented system manages and schedules group oriented collaborative activities. The design guidelines of internet based collaborative design & DFMA are expressed. The components and the manufacturing stages of axial eccentric oil-pump are expressed in detail. The file formats of the presented system include the data types of collaborative design of the product, assembly design, assembly planning and assembly system design. Product design and assembly planning can be operated synchronously and intelligently and they are integrated under the condition of internet based collaborative design and DFMA. The technologies of collaborative modelling, collaborative manufacturing, and internet based collaborative assembly for the specific pump construction are developed. A seven-security level is presented to ensure the security of the internet based collaborative design system.
Resumo:
Tässä diplomityössä käsitellään pumppujen maailmanlaajuista varaosa-jakelua. Työn pääpaino on varaosien moniportaisen jakeluverkon toimitusketjun logistiikassa. Asiakaspalvelussa varaosien nopea saatavuus on ratkaisevassa asemassa, jotta asiakkaiden tehtaiden käynnissäpito voidaan turvata. Työn tavoitteena oli kehittää Ahlström Pumpuille uusi globaali toimintamalli varaosien jakeluun. Tämä uusi varaosien jakelumalli on kehitetty pääasiassa sopimusasiakkaille, jotka ovat halukkaita ulkoistamaan varaosatoimintonsa. Mallia sovelletaan käytäntöön varaosien jakelussa ensiksi Suomessa ja Ruotsissa. Myöhemmin on tarkoitus kopioida mallia myös muualle. Malli on pyritty rakentamaan siten, että siihen voidaan helposti liittää muita Ahlström Pumppujen tarjoamia palveluita. Työssä koottu materiaali perustuu pääasiassa haastatteluihin, palavereihin, erilaisiin sisäisiin raportteihin, kirjallisuuteen ja itsenäiseen selvitystyöhön. Työssä on myös tutustuttu kolmen eri yrityksen after-sales- ja varaosatoimintaan.
Resumo:
This thesis analyses the calculation of FanSave and PumpSave energy saving tools calculation. With these programs energy consumption of variable speed drive control for fans and pumps can be compared to other control methods. With FanSave centrifugal and axial fans can be examined and PumpSave deals with centrifugal pumps. By means of these programs also suitable frequency converter can be chosen from the ABB collection. Programs need as initial values information about the appliances like amount of flow and efficiencies. Operation time is important factor when calculating the annual energy consumption and information about it are the length and profile. Basic theory related to fans and pumps is introduced without more precise instructions for dimensioning. FanSave and PumpSave contain various methods for flow control. These control methods are introduced in the thesis based on their operational principles and suitability. Also squirrel cage motor and frequency converter are introduced because of their close involvement to fans and pumps. Second part of the thesis contains comparison between results of FanSave’s and PumpSave’s calculation and performance curve based calculation. Also laboratory tests were made with centrifugal and axial fan and also with centrifugal pump. With the results from this thesis the calculation of these programs can be adjusted to be more accurate and also some new features can be added.
Resumo:
Background: The long-term side-effects of cancer treatments are of growing importance, since the number of pediatric cancer survivors has considerably increased. Renal side-effects should be noted early to prevent further deterioration. Renal dysfunction may also develop long after cancer treatment. Easy and reliable methods for assessing renal function are needed. Aims: The aims were to find the mechanisms behind methotrexate-induced renal damage by studying renal tubular cells (LLC-PK1cells), and to evaluate the usefulness of laboratory tests in assessing glomerular function in pediatric cancer patients by comparing an isotope clearance method with alternative methods. The aim was also to study the long-term effects of bone marrow transplantation (BMT) and high-dose methotrexate (HD-MTX) treatment in renal function. Results: Methotrexate induced time-dependent renal tubular cell swelling and cell death. In patients treated with HD-MTX a significant decrease in GFR was noted after a follow-up time of one to ten years. One year after BMTthe GFR was reduced, especially in patients treated with total body irradiation (TBI). GFR recovered slightly but remained stable thereafter. In glomerular function assessment the serum cystatin C (cysC) concentration showed a significant association with GFR measured by the isotope method. Conclusions: Methotrexate induced acute damage in renal tubular cells. In assessing GFR the isotope method still remains the method of choice, but the assay of cystatin C was the most reliable of other alternatives. Long-term follow-up of renal function is needed in BMT patients and patients treated with HD-MTX.
Resumo:
This thesis includes several thermal hydraulic analyses related to the Loviisa WER 440 nuclear power plant units. The work consists of experimental studies, analysis of the experiments, analysis of some plant transits and development of a calculational model for calculation of boric acid concentrations in the reactor. In the first part of the thesis, in the case of won of boric acid solution behaviour during long term cooling period of LOCAs, experiments were performed in scaled down test facilities. The experimental data together with the results of RELAPS/MOD3 simulations were used to develop a model for calculations of boric acid concentrations in the reactor during LOCAs. The results of calculations showed that margins to critical concentrations that would lead to boric acid crystallization were large, both in the reactor core and in the lower plenum. This was mainly caused by the fact that water in the primary cooling circuit includes borax (Na)BsO,.IOHZO), which enters the reactor when ECC water is taken from the sump and greatly increases boric acid solubility in water. In the second part, in the case of simulation of horizontal steam generators, experiments were performed with PACTEL integral test loop to simulate loss of feedwater transients. The PACTEL experiments, as well as earlier REWET III natural circulation tests, were analyzed with RELAPS/MOD3 Version Sm5 code. The analysis showed that the code was capable of simulating the main events during the experiments. However, in the case of loss of secondary side feedwater the code was not completely capable to simulate steam superheating in the secondary side of the steam generators. The third part of the work consists of simulations of Loviisa VVER reactor pump trip transients with RELAPSlMODI Eur, RELAPS/MOD3 and CATHARE codes. All three codes were capable to simulate the two selected pump trip transients and no significant differences were found between the results of different codes. Comparison of the calculated results with the data measured in the Loviisa plant also showed good agreement.
Resumo:
In the current economy situation companies try to reduce their expenses. One of the solutions is to improve the energy efficiency of the processes. It is known that the energy consumption of pumping applications range from 20 up to 50% of the energy usage in the certain industrial plants operations. Some studies have shown that 30% to 50% of energy consumed by pump systems could be saved by changing the pump or the flow control method. The aim of this thesis is to create a mobile measurement system that can calculate a working point position of a pump drive. This information can be used to determine the efficiency of the pump drive operation and to develop a solution to bring pump’s efficiency to a maximum possible value. This can allow a great reduction in the pump drive’s life cycle cost. In the first part of the thesis, a brief introduction in the details of pump drive operation is given. Methods that can be used in the project are presented. Later, the review of available platforms for the project implementation is given. In the second part of the thesis, components of the project are presented. Detailed description for each created component is given. Finally, results of laboratory tests are presented. Acquired results are compared and analyzed. In addition, the operation of created system is analyzed and suggestions for the future development are given.
Resumo:
Centrifugal pumps are widely used in industrial and municipal applications, and they are an important end-use application of electric energy. However, in many cases centrifugal pumps operate with a significantly lower energy efficiency than they actually could, which typically has an increasing effect on the pump energy consumption and the resulting energy costs. Typical reasons for this are the incorrect dimensioning of the pumping system components and inefficiency of the applied pump control method. Besides the increase in energy costs, an inefficient operation may increase the risk of a pump failure and thereby the maintenance costs. In the worst case, a pump failure may lead to a process shutdown accruing additional costs. Nowadays, centrifugal pumps are often controlled by adjusting their rotational speed, which affects the resulting flow rate and output pressure of the pumped fluid. Typically, the speed control is realised with a frequency converter that allows the control of the rotational speed of an induction motor. Since a frequency converter can estimate the motor rotational speed and shaft torque without external measurement sensors on the motor shaft, it also allows the development and use of sensorless methods for the estimation of the pump operation. Still today, the monitoring of pump operation is based on additional measurements and visual check-ups, which may not be applicable to determine the energy efficiency of the pump operation. This doctoral thesis concentrates on the methods that allow the use of a frequency converter as a monitoring and analysis device for a centrifugal pump. Firstly, the determination of energy-efficiency- and reliability-based limits for the recommendable operating region of a variable-speed-driven centrifugal pump is discussed with a case study for the laboratory pumping system. Then, three model-based estimation methods for the pump operating location are studied, and their accuracy is determined by laboratory tests. In addition, a novel method to detect the occurrence of cavitation or flow recirculation in a centrifugal pump by a frequency converter is introduced. Its sensitivity compared with known cavitation detection methods is evaluated, and its applicability is verified by laboratory measurements for three different pumps and by using two different frequency converters. The main focus of this thesis is on the radial flow end-suction centrifugal pumps, but the studied methods can also be feasible with mixed and axial flow centrifugal pumps, if allowed by their characteristics.
Resumo:
Decreasing bone mass during aging predisposes to fractures and it is estimated that every second woman and one in five men will suffer osteoporotic fractures during their lifetime. Bone is an adaptive tissue undergoing continuous remodeling in response to physical and metabolic stimuli. Bone mass decreases through a net negative balance in the bone remodeling process of bone, in which the new bone incompletely replaces the resorbed bone mass. Bone resorption is carried out by the osteoclasts; the bone mineral is solubilized by acidification and the organic matrix is subsequently degraded by proteases. Several classes of drugs are available for prevention of osteoporotic fractures. They act by different mechanisms to increase bone mass, and some of them act mainly as antiresorptives by inhibition of osteoclast formation or their function. Optimally, a drug should act selectively on a specific process, since other processes affected usually result in adverse effects. The purpose of this study was to evaluate whether the osteoclastic vacuolar adenosine trisphosphatases (V-ATPase), which drives the solubilization of bone mineral, can be selectively inhibited despite its ubiquitous cellular functions. The V-ATPase is a multimeric protein composed of 13 subunits of which six possesses two or more isoforms. Selectivity for the osteoclastic V-ATPase could be provided if it has some structural uniqueness, such as a unique isoform combination. The a3 isoform of the 116kDa subunit is inevitable for bone resorption; however, it is also present in, and mainly limited to, the lysosomes of other cells. No evidence of a structural uniqueness of the osteoclastic V-ATPase compared to the lysosomal V-ATPase was found, although this can not yet be excluded. Thus, an inhibitor selective for the a3 isoform would target the lysosomal V-ATPase as well. However, the results suggest that selectivity for bone resorption over lysosomal function can be obtained by two other mechanisms, suggesting that isoform a3 is a valid target. The first is differential compensation; bone resorption depends on the high level of a3 expression, and is not compensated for by other isoforms, while the lower level of a3 in lysosomes of other cells may be partly compensated for. The second mechanism is because the bone resorption process itself is fundamentally different from lysosomal acidification because of the chemistry of bone dissolution and the anatomy of the resorbing osteoclast. By this mechanism, full inhibition of bone resorption is obtained with more than tenfold lower inhibitor concentration than those needed to fully inhibit lysosomal acidification. The two mechanisms are additive. Based on the results, we suggest that bone resorption can be selectively inhibited if VATPase inhibitors that are sufficiently selective for the a3 isoform over the other isoforms are developed.
Resumo:
Approximately a quarter of electrical power consumption in pulp and paper industry is used in different pumping systems. Therefore, improving pumping system efficiency is a considerable way to reduce energy consumption in different processes. Pumping of wood pulp in different consistencies is common in pulp and paper industry. Earlier, centrifugal pumps were used to pump pulp only at low consistencies, but development of MC technology has made it possible to pump medium consistency pulp. Pulp is a non-Newtonian fluid, which flow characteristics are significantly different than what of water. In this thesis is examined the energy efficiency of pumping medium consistency pulp with centrifugal pump. The factors effecting the pumping of MC pulp are presented and through case study is examined the energy efficiency of pumping in practice. With data obtained from the case study are evaluated the effects of pump rotational speed and pulp consistency on energy efficiency. Additionally, losses caused by control valve and validity of affinity laws in pulp pumping are evaluated. The results of this study can be used for demonstrating the energy consumption of MC pumping processes and finding ways to improve energy efficiency in these processes.
Resumo:
Human trafficking is not a new phenomenon. It has existed in various forms for ages around the world. Some researchers have even compared it to slavery, calling it the modern form of slavery in the 21st century. This study is particularly interested in the role of work-related human trafficking in Finnish business. In order for something to be called work-related human trafficking, the concepts of forced labour and human trafficking have to overlap. From the economic point of view, human trafficking is governed by the laws of supply and demand. In many countries the global pressure on cutting costs has created two trends: the increased supply of migrant workers and the deregulation of labour markets. These competitive pressures can have an adverse impact on the conditions of employment and, in the worst cases, can lead to forced labour and trafficking. In fact, trafficking has become one of the most profitable illicit industries worldwide, generating tremendous profits due to its low costs and huge profits. Therefore, it is important to investigate the phenomenon from the business point of view. This study is a qualitative research conducted by using theme interviews as a research approach. Altogether 13 interviews have been conducted and some secondary data has been used in order to find out what the role of human trafficking is in Finnish business. The special sectors investigated are the Finnish construction and service sectors. The theory framework used in this study follows the stakeholder approach. The relevant stakeholder groups for this study are: ‘institutions and authorities’, ‘law enforcement’, ‘management’ and ‘employees – potential victims’ of trafficking. With the help of these stakeholder groups, a holistic picture of the phenomenon is formed. It can be concluded that the role of human trafficking is complicated but it does exist in Finnish business. It appears in low-cost business sectors where the demand for cheap labour is high. Thus, often the victims are foreigners who do not know the culture or the Finnish conditions of employment. Especially smaller Finnish companies are at risk of getting involved in human trafficking or related exploitation cases since monitoring is much more scarce in these firms than in larger companies. The risk of human trafficking and exploitation is also higher at the bottom of the complicated subcontracting chains or when using foreign recruitment agencies. Thus, the study believes that active and intensive collaboration between the company’s different stakeholder groups is needed in order to prevent work-related human trafficking from flourishing in Finland.