5 resultados para shape displays
em Doria (National Library of Finland DSpace Services) - National Library of Finland, Finland
Resumo:
The reformation of power sector is still in the process of development. The present day situation in Russian electricity power market ischaracterized as transitional period: competitive electricity market is forming, new companies are being created and the power of government regulation is decreasing. The main aim of the reformation is to attract much-needed private investments to the power sector. The electricity consumption increases very rapidly and power sector has to cope with high demand. The goal of this master's thesis is to analyze the nowadays situation in Russian power sector, such as generation structure, condition of electricity networks, electricity price formation for end-users, shape of fuel sector and investments risks and attraction.The final result of this work is creation of scenario of Russian power sector future shape and analysis of the present day situation.
Resumo:
The main objective of this thesis was to design a hinge and a closing mechanism for the plastic rim of a paperboard package. Of the hinge and closing mechanisms the 3D-models were designed using SolidWorks program and the functionality of the mechanisms was tested with rapid prototype models. When a mechanism that worked was found, the manufacturability of the mechanisms was tested in an injection molding machine with changeable inserts. Another objective of this thesis was to test the effect of the shape of paperboard package to its manufacturability. The effect of the packages shape was tested with plastic tools made for three different shaped trays. Suggestions for further research were made according to the results of the thesis.
Resumo:
The Repair of segmental defects in load-bearing long bones is a challenging task because of the diversity of the load affecting the area; axial, bending, shearing and torsional forces all come together to test the stability/integrity of the bone. The natural biomechanical requirements for bone restorative materials include strength to withstand heavy loads, and adaptivity to conform into a biological environment without disturbing or damaging it. Fiber-reinforced composite (FRC) materials have shown promise, as metals and ceramics have been too rigid, and polymers alone are lacking in strength which is needed for restoration. The versatility of the fiber-reinforced composites also allows tailoring of the composite to meet the multitude of bone properties in the skeleton. The attachment and incorporation of a bone substitute to bone has been advanced by different surface modification methods. Most often this is achieved by the creation of surface texture, which allows bone growth, onto the substitute, creating a mechanical interlocking. Another method is to alter the chemical properties of the surface to create bonding with the bone – for example with a hydroxyapatite (HA) or a bioactive glass (BG) coating. A novel fiber-reinforced composite implant material with a porous surface was developed for bone substitution purposes in load-bearing applications. The material’s biomechanical properties were tailored with unidirectional fiber reinforcement to match the strength of cortical bone. To advance bone growth onto the material, an optimal surface porosity was created by a dissolution process, and an addition of bioactive glass to the material was explored. The effects of dissolution and orientation of the fiber reinforcement were also evaluated for bone-bonding purposes. The Biological response to the implant material was evaluated in a cell culture study to assure the safety of the materials combined. To test the material’s properties in a clinical setting, an animal model was used. A critical-size bone defect in a rabbit’s tibia was used to test the material in a load-bearing application, with short- and long-term follow-up, and a histological evaluation of the incorporation to the host bone. The biomechanical results of the study showed that the material is durable and the tailoring of the properties can be reproduced reliably. The Biological response - ex vivo - to the created surface structure favours the attachment and growth of bone cells, with the additional benefit of bioactive glass appearing on the surface. No toxic reactions to possible agents leaching from the material could be detected in the cell culture study when compared to a nontoxic control material. The mechanical interlocking was enhanced - as expected - with the porosity, whereas the reinforcing fibers protruding from the surface of the implant gave additional strength when tested in a bone-bonding model. Animal experiments verified that the material is capable of withstanding load-bearing conditions in prolonged use without breaking of the material or creating stress shielding effects to the host bone. A Histological examination verified the enhanced incorporation to host bone with an abundance of bone growth onto and over the material. This was achieved with minimal tissue reactions to a foreign body. An FRC implant with surface porosity displays potential in the field of reconstructive surgery, especially regarding large bone defects with high demands on strength and shape retention in load-bearing areas or flat bones such as facial / cranial bones. The benefits of modifying the strength of the material and adjusting the surface properties with fiber reinforcement and bone-bonding additives to meet the requirements of different bone qualities are still to be fully discovered.