25 resultados para sedimentation basin sludge

em Doria (National Library of Finland DSpace Services) - National Library of Finland, Finland


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the sparsely populated areas of Finland there are approximately 350 000 households and 450 000 leisure time residences outside sewer networks. According to the Finnish domestic wastewater act outside sewer networks, the Finnish Government is reducing the environmental load of domestic wastewaters by the year 2017. The law is aimed at restricting the quality of sludge from domestic wastewater purification systems. The wastewater purification systems are complex systems, which often include sedimentation basins. The sedimentation basins remove most of the nutrients from the domestic wastewaters. The Finnish Government has decided that sedimentation basin sludge must be treated before reusing. One possibility is to stabilise domestic sludge with slaked lime and to reuse treated sludge in agriculture. According to this master’s thesis lime stabilisation can be done in sedimentation basins or in decanting tanks. Decanting tanks must be under 100 m3. Dosage of stabilisation is 8,5 kg/m3 of lime. If you are treading sludge that is highly hydrous, you need 13,5 kg/m3 of lime. In stabilisation lime and sludge must be thoroughly mixed. Mixed sludge must be in sedimentation basin at least two hours. If there is evidence that sludge contains salmonella or if it’s decanting tank stabilisation time is 48 hours. Sludge must be mixed at least once during the longer stabilisation time. Lime destroys Esherichia coli and enterococcus concentrations below accepted level. Lime also destroys Salmonella bacterium. After treating, sludge’s can be distributed over a field. You can safely spread lime treated domestic sludge’s about 40 m3/ha. Lime stabilisation can also be used to treat separately and collectively collected domestic wastewaters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Selostus: Viljelyvyöhykkeiden ja kasvumallien soveltaminen ilmastonmuutoksen tutkimisessa: Mackenzien jokialue, Kanada

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Työn tavoitteena on ollutselvittää kustannukset, joita syntyy, jos Kuusankosken kaupungin puhdistamolta johdetaan jätevedet UPM-Kymmene Oyj:n Kymin aktiivilietelaitokselle puhdistettaviksi, ja kustannukset, joita aiheutuu kaupungin puhdistamon laajentamisesta typenpoistoon sopivaksi sekä verrata näiden hankkeiden kustannuksia. Työssä selvitetään myös muutokset, joita yhteispuhdistukseen siirtymisestä aiheutuu Kymin aktiivilietelaitokselle ja miten jätevesikuormitus Kymijokeen muuttuu. Lisäksi työssäon tarkasteltu yhdyskuntajätevedenpuhdistamoilta tuotujen lietteiden vaikutustaKymin aktiivilietelaitoksen toimintaan ja luotu katsaus käytössä olevien metsäteollisuusyritysten ja kaupunkien yhteispuhdistamojen toimintaan Raumalla ja Grand Rapids:ssa. Yhdyskuntajätevesien yhteispuhdistuksesta sellu- ja paperitehtaan aktiivilietelaitoksessa on saatu hyviä kokemuksia Raumalta. Kokonaistyppikuormitus Rauman merialueelle on puolittunut ja lisäksi fosfori- ja BOD-kuormitukset ovat vähentyneet. Ravinteiden tarve puhdistamolla on kuitenkin ennakoitua suurempija ravinteiden kulutusta voidaan selittää monella tekijällä mm. lämpötilan laskulla ja lietekuorman lisääntymisellä. Kymin puhdistamolle on tuotu Akanojan puhdistamon ylijäämäliete vuodesta 1996 lähtien. Vuoden 2004 marras- ja joulukuussa suoritetussa kokeilussa Kymin puhdistamolle tuotiin Akanojan lietteiden lisäksi osa Kouvolan puhdistamolla syntyneistä lietteistä. Kokeilun perusteella voidaan todeta, että yhdyskuntajätevesilietteiden tuonnilla voidaan korvata puhdistamolla tarvittavia ravinteita. Uusi jätteenpolttodirektiivi tuskin aiheuttanee ongelmia poltettaessa voimalaitoksella ylijäämälietettä, joka sisältää myös yhdyskuntajätevesistä peräisin olevaa lietettä. Kymin aktiivilietelaitoksen lämpötila tulee laskemaan yhteispuhdistukseen siirryttäessä viileiden yhdyskuntajätevesien vaikutuksesta. Yhteispuhdistustilanteessa Kuusankosken keskustan jokialueen bakteeritilanteeseen ei ole todennäköisesti tulossa muutosta, mutta virustilanteen muuttuminen voi olla mahdollista. Yhteispuhdistukseen siirryttäessä Kymin puhdistamon kapasiteettia tarvitsee kasvattaa ainoastaan jälkiselkeytyksen suhteen. Yhteispuhdistustilanteessa jätevesikuormitus Kymijokeen tulee pienenemään erityisesti typen osalta ja myös BOD- ja fosforikuormat pienenevät. COD-kuormitus pysyy lähes ennallaan ja kiintoainekuorma saattaa lisääntyä hiukan. Yhteispuhdistustilanteessa Kymijokeen aiheutuu jätevesikuormitusta myös ohituksista, kun yhdyskuntajätevesimäärä ylittää hetkellisesti esimerkiksi rankkasateen sattuessa mitoitusvirtaamansa arvon. Investointikustannukseksi, Kuusankosken kaupungin puhdistamon muuttamisesta typenpoistoon sopivaksi, arvioitiin mitoitusvirtaamasta riippuen 3 210 000 ¤ tai 2 460 000 ¤. Yhteispuhdistukseen siirtyminen aiheuttaa kaupungille n. 3 755 000 ¤ investointikustannuksen ja Kymin puhdistamolle n. 365 000 ¤. Investointikustannuksiltaan yhteispuhdistukseen siirtyminen tulee kaupungille kalliimmaksi mutta pitkällä aikavälillä tarkasteltuna edullisempi vaihtoehto Kuusankosken kaupungin kannalta on siirtyminen yhteispuhdistukseen.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim of this study was to investigate the means to reduce nutrient flows to water systems. Focus in this study was to examine peatland buffer zones as a solution to protect water bodies as well as to examine methane and nitrous oxide release from buffer zones. The literature survey covers a review of research which has been done till this day concerning the effects of forestry on water bodies. It also contains a review of the significance of forests and mires in hydrological cycle, effects of forestry on nutrient loads to water systems and a review of different solutions to diminish it. The solutions contain ditch shaping, submerged dams, sludge sumps, sedimentation ponds and buffer zones. The literature survey also covers nitrous oxide and methane gas emissions from buffer zones. Methane and nitrous oxide emissions from six different mires were studied during the summer of 2007. Measurements were conducted once a month using the static chamber method. Emissions of methane and nitrous oxide were calculated. Effects of water table level and peat temperature on emissions were also studied. The results showed a tendency to increased methane-emissions from natural peat lands when compared with restored buffer zones. The results showed also a tendency to increased CH4 emissions and decreased NO2 emissions with rising level of water table. Other mechanisms that influence emissions are vegetation composition and peat temperature. Considering the global warming as a result of increased greenhouse gas emissions, the emissions of CH4 and NO2 measured in the present study were not particularly high.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Työssä tutkittiin pienpuhdistamon ylijäämälietteen ominaisuuksia ja käyttäytymistä pienpuhdistamon ylijäämälietteen tiivistys- tai kuivausmenetelmän kehittämisen teoriapohjaksi. Työ sisältää myös lietteiden tiivistysmenetelmien kustannustarkastelua. Kokeellisessa osuudessa käytettiin työn teettäjän Oy KWH Pipe Ab:n valmistamien pienpuhdistamojen ylijäämälietettä. Tutkittava ylijäämäliete oli peräisin asukasvastineluvultaan 5–95 pienistä aktiivilietelaitepuhdistamoista. Tiivistys- tai kuivausmenetelmän kehittämisen tarkoituksena on saavuttaa kustannussäästöjä pienpuhdistamon ylijäämälietteen kuljetusmatkojen vähentämisen kautta. Soveltuvia vertailtavia sovelluksia ovat staattiseen laskeuttamiseen perustuvat menetelmät, mekaaniset ruuvi- ja linkokuivaimet, kuivauslava ja flotaatio. Tarkasteltavien menetelmien tuli olla käytöltä ja huollolta sekä käyttökuluiltaan edullisia ja yksinkertaisia. Ylijäämälietteiden ominaisuuksia ja käyttäytymistä tutkittiin kirjallisuuslähteistä ja käytännön kokein. Kokeissa tarkasteltiin ylijäämälietteen laskeutumis- ja nousuominaisuuksia, redox-potentiaalin vaihtelua seisovassa näytteessä ja flotaation onnistumista testattavalle lietteelle. Kokeet tehtiin kullakin kerralla eri ajankohtana otetuille lietenäytteille, käytettyjä puhdistamoja oli useita ja mitoitus, kuormitus sekä jäteveden laatu vaihteli paljon.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The problem concerning livestock waste handling in the Leningrad region has been subjected to a number of research works. However, the requirements for use of manure and sewage sludge as well as for treatment processes are not certain. So, this problem remains relevant and, therefore, further investigation ought to be made. Currently a large amount of sewage sludge and manure is generated in the Leningrad region. These livestock wastes have to be obligatory treated. The most common methods for treatment in the region, such as anaerobic digestion, composting and aging as well as the most potential methods are described in the thesis. The most potential methods for the Leningrad region are anaerobic digestion, composting and combustion. Each method has strengths and weaknesses, which are also considered in the paper. Aging was not considered as potential treatment method because it does not meet the sanitary and epidemiological requirements. Furthermore, the work gives an overview and comparison of Finnish and Russian legislative and normative acts concerning livestock wastes handling. On the whole the requirements of the Russian Federation concerning sewage sludge and manure are not much different from the Finnish ones.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The UPM-Kymmene Oyj Pietarsaari pulp and paper Mill biological wastewater treatment plant was built in the 1980's and the plant has been in use ever since. During the past years there have been problems with deviations. The wastewater treatment plant needs update, especially the aeration basin, where the old surface aerators cannot produce enough mixing and indroduce oxygen enough to the wastewater. In this thesis how extra aeration with oxygen affects the wastewater treatment plant effluent was studied. In the literature part the main focus is in aeration devices, which can be used in biological wastewater treatment. The target is to compare different kind of aerators, which are suitable for pulp and paper wastewater treatment. Studies show, that EDI-aerators are commonly used and also most suitable. In the experimental part, the focus is on the Pietarsaari Mills wastewater treatment plant and oxygen aeration during autumn 2008. This thesis presents the results of the trial run. Studies show, that extra oxygen devices can produce lot a of mixing and the oxygenation capacity was more than what the micro-organisms needed. The effect on sludge quality could not been seen during the trial runs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The nutrient load to the Gulf of Finland has started to increase as a result of the strong economic recovery in agriculture and livestock farming in the Leningrad region. Also sludge produced from municipal wastewater treatment plant of the Leningrad region causes the great impact on the environment, but still the main options for its treatment is disposal on the sludge beds or Landfills. The aim of this study was to evaluate the implementation of possible joint treatment methods of manure form livestock and poultry enterprises and sewage sludge produced from municipal wastewater treatment plants in the Leningrad region. The study is based on published data. The most attention was put on the anaerobic digestion and incineration methods. The manure and sewage sludge generation for the whole Leningrad region and energy potential produced from their treatment were estimated. The calculations showed that total amount of sewage sludge generation is 1 348 000 t/a calculated on wet matter and manure generation is 3 445 000 t/a calculated on wet matter. The potential heat release from anaerobic digestion process and incineration process is 4 880 000 GJ/a and 5 950 000 GJ/a, respectively. Furthermore, the work gives the overview of the general Russian and Finnish legislation concerning manure and sewage sludge treatment. In the Gatchina district it was chosen the WWTP and livestock and poultry enterprises for evaluation of the centralized treatment plant implementation based on anaerobic digestion and incineration methods. The electricity and heat power of plant based on biogas combustion process is 4.3 MW and 7.8 MW, respectively. The electricity and heat power of plant based on manure and sewage sludge incineration process is 3.0 MW and 6.1 MW, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Diplomityön tavoitteena oli tutkia biokaasulaitoksen rejektivesien ominaisuuksiin vaikuttavia tekijöitä ja rejektiveden esikäsittelyn tarpeellisuutta. Lisäksi tavoitteena oli tarkastella Kouvolaan suunnitteilla olevan Kymen Bioenergia Oy:n biokaasulaitoksen rejektivesien vaikutusta Kouvolan Veden Mäkikylän jätevedenpuhdistamolla. Biokaasulaitoksen rejektivedet ovat yhdyskuntajätevesiin verrattuna selvästi konsentroituneempia. Jätevedenpuhdistamoilla erityisesti rejektiveden korkea typpipitoisuus aiheuttaa lisäkuormitusta. Suomessa toiminnassa oleville biokaasulaitoksille tehdyn kyselytutkimuksen tulosten perusteella rejektiveden typpipitoisuuteen vaikuttaa syötteen typpipitoisuus sekä mädätysjäännöksen kuivauksen tehokkuus. Rejektiveden kiintoainepitoisuudella on puolestaan vaikutusta biologiseen hapenkulutukseen ja välillisesti myös rejektiveden kemialliseen hapenkulutukseen. Rejektivesien jätevedenpuhdistamoilla aiheuttamaa kuormitusta on mahdollista vähentää esikäsittelemällä rejektivedet joko biologisella tai fysikaalis-kemiallisella puhdistusmenetelmällä. Kyselytutkimus kuitenkin osoitti, että rejektivesien esikäsittelyssä ei aina päästä puhdistustavoitteeseen. Jätevedenkäsittelyn sijaan rejektivesiä on mahdollista käyttää lannoitteena, mikäli biokaasulaitoksen syöte ei sisällä jätevedenpuhdistamon lietteitä. Myös Kouvolan Veden Mäkikylän puhdistamolla biokaasulaitoksen rejektivedet tulevat lisäämään merkittävästi tulovirtaaman typpikuormaa. Typpikuorman lisäys edellyttää ilmastusaltaassa ilmastuksen tehostamista sekä kalkin syöttömäärän lisäämistä, jotta jäteveden happipitoisuus ja pH pysyvät typenpoistoreaktioille suotuisina. Lisäksi tulovirtaamasta puolet tullaan ohjaamaan esiselkeyttimen ohi, jotta ilmastusaltaassa on orgaanista ainetta typenpoistoon riittävästi. Mäkikylän puhdistamon typenpoistokapasiteettia on mahdollista kasvattaa lisähiilen syötöllä. Mikäli biokaasulaitoksen kapasiteettilisäyksen jälkeen rejektivesien typpikuoma ylittää lisähiilellä saavutetun lisäkapasiteetin, on rejektivedet esikäsiteltävä.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Original sludge from wastewater treatment plants (WWTPs) usually has a poor dewaterability. Conventionally, mechanical dewatering methods are used to increase the dry solids (DS) content of the sludge. However, sludge dewatering is an important economic factor in the operation of WWTPs, high water content in the final sludge cake is commonly related to an increase in transport and disposal costs. Electro‐dewatering could be a potential technique to reduce the water content of the final sludge cake, but the parameters affecting the performance of electro‐dewatering and the quality of the resulting sludge cake, as well as removed water, are not sufficiently well known. In this research, non‐pressure and pressure‐driven experiments were set up to investigate the effect of various parameters and experimental strategies on electro‐dewatering. Migration behaviour of organic compounds and metals was also studied. Application of electrical field significantly improved the dewatering performance in comparison to experiments without electric field. Electro‐dewatering increased the DS content of the sludge from 15% to 40 % in non‐pressure applications and from 8% to 41% in pressure‐driven applications. DS contents were significantly higher than typically obtained with mechanical dewatering techniques in wastewater treatment plant. The better performance of the pressure‐driven dewatering was associated to a higher current density at the beginning and higher electric field strength later on in the experiments. The applied voltage was one of the major parameters affecting dewatering time, water removal rate and DS content of the sludge cake. By decreasing the sludge loading rate, higher electrical field strength was established between the electrodes, which has a positive effect on an increase in DS content of the final sludge cake. However interrupted voltage application had anegative impact on dewatering in this study, probably because the off‐times were too long. Other factors affecting dewatering performance were associated to the original sludge characteristics and sludge conditioning. Anaerobic digestion of the sludge with high pH buffering capacity, polymer addition and freeze/thaw conditioning had a positive impact on dewatering. The impact of pH on electro‐dewatering was related to the surface charge of the particles measured as zeta‐potential. One of the differences between electro‐dewatering and mechanical dewatering technologies is that electro‐dewatering actively removes ionic compounds from the sludge. In this study, dissolution and migration of organic compounds (such as shortchain fatty acids), macro metals (Na, K, Ca, Mg, Fe) and trace metals (Ni, Mn, Zn, Cr) was investigated. The migration of the metals depended on the fractionation and electrical field strength. These compounds may have both negative and positive impacts on the reuse and recycling of the sludge and removed water. Based on the experimental results of this study, electro‐dewatering process can be optimized in terms of dewatering time, desired DS content, power consumption and chemical usage.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Suurelta osin Natura-alueeseen kuuluvan Kokemäenjoen suistoalueen kuivan maan ja suiston edustan vesialueen erityyppisten maaperäkerrostumien kerrosjärjestys ja alueellinen jakautuminen selvitettiin pintamaaperän kartoituksella, tutkimuskaivannoilla ja kairauksella. Suiston kerrostumat luokiteltiin viiteen maaperämuodostumaan. Vanhimmasta nuorimpaan, Toukari, Vainio-Mattila, Hevosluoto, Lanajuopa ja Säikkä muodostumaan. Nämä edustavat vanhoja Itämeren altaan ja nuorempia merelle päin etenevän suiston eri osien kerrostumisympäristöjä. Eri muodostumien fysikaaliset ja kemialliset ominaisuudet kuvattiin ja ne eroavat luonteeltaan ratkaisevasti toisistaan. Suiston etenemistä edustavat Hevosluoto- ja Säikkä-muodostumat ovat kontaminoituneet 1900-luvun alkupuolelta lähtien yhä voimakkaammin ihmistoiminnasta kertyvistä raskasmetallipitoisuuksista ja orgaanisista haitta-aineista. Tämä näkyy erityisesti elohopean, kadmiumin, arseenin, lyijyn, sinkin, nikkelin, dioksiinien ja furaanien kokonaispitoisuuksien kasvuna näissä muodostumissa. Pitoisuudet ovat suurimpia muodostumien nuorimmissa osissa. Kuivalla maalla raskasmetallipitoisuudet ylittävät paikoin valtioneuvoston pilaantuneelle maaperälle asettamat kynnysarvot, jolloin säädökset on huomioitava suiston maaperää muokattaessa. Vesialueella nämä kynnysarvot ylittyvät myös orgaanisten haitta-aineiden osalta. Tietyin osin ovat esimerkiksi arseenin ja nikkelin osalta taustapitoisuudet suistoalueen vanhimmassa Toukari muodostumassa jo luontaisesti kynnysarvoja suuremmat. Tämä pitää osata ottaa huomioon maansiirtotoimenpiteitä suunniteltaessa. Suistoon kerrostuvan maa-aineksen ja nopean maankohoamisen vuoksi suisto etenee nykyisin 30-40 m vuodessa merialueelle päin. Tämä mataloittaa vääjäämättömästi suiston edustan vesialueita kerrostumisen siirtyessä merelle päin. Näin myös Natura-alueen ainutlaatuiset biotoopit vähitellen siirtyvät merelle päin.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis includes detailed sedimentological and ichnological studies on two geological units: the Pebas Formation, with a special focus in its informal upper member, and the Nauta Formation. Both formations were deposited during the Miocene in Northeastern Peruvian Amazonia, in the Amazon retroarc foreland basin. The Pebas and Nauta successions mainly consist of non-consolidated, clastic sedimentary deposits arranged into sand- to mud-dominated heterolithic successions, which can be upward-coarsening to upward-fining. Sediments in both the Pebas and Nauta successions range from mud to fine- to medium-grained sand. The main facies observed were 1) mud-dominated horizontal heterolithic couplets; 2) rooted brownish mud; 3) lenticular, mud-draped, cross-stratified sand; 4) mud- to sand-dominated, inclined heterolithic stratification; 5) sand-dominated horizontal heterolithic couplets; and 6) mud-draped, trough cross-stratified sand. Locally, tidal rhythmites were documented. The facies are interpreted as: 1) muddy, shallow, subaqueous flats/shoals; 2) palaeosols; 3) secondary tidal channels or run-off creeks; 4) tidally influenced point bars; 5) shoreface deposits; and 6) subtidal compound dunes. Thalassinoides-dominated Glossifungites ichnofacies, low-diversity expressions of the Skolithos ichnofacies and depauperate suites consisting of elements common to the Cruziana ichnofacies strongly indicate brackish-water conditions. However, continental trace fossil assemblages, with possible elements common to the Scoyenia ichnofacies, have also been identified. In addition to the palaeoenvironmental study, a local hydrogeochemical characterisation of the Pebas and Nauta formations was also conducted. The geochemistry of the groundwaters reflects the characteristics and the soil geochemistry of the geological formations studied. The Pebas formation has low hardness, acid to neutral waters, whereas the upper Pebas has high hardness, acid to neutral waters. In both units, the arsenic content is locally high. The Nauta formation has low hardness acid groundwaters. A regional review of the Pebas and Nauta formations placed the local observations into a continental perspective and suggests that the whole Pebas-Nauta system was a probably shallow (some tens of metres at maximum), brackish- to freshwater, tidally-influenced epicontinental embayment with a probable semi-diurnal to mixed tidal regime and a microtidal range, surrounded by continental environments such as forest floors, lagoons, rivers and their flood plains, and lakes.