10 resultados para priming effect of soil organic
em Doria (National Library of Finland DSpace Services) - National Library of Finland, Finland
Effect of soil-spraying time on root-colonization ability of antagonistic Streptomyces griseoviridis
Resumo:
Selostus: Kasvualustan käsittelyajan vaikutus Streptomyces griseoviridis -antagonistin juurten asutuskykyyn
Resumo:
Selostus: Maan märkyyden vaikutus ilman koostumukseen ja dityppioksidiemissioon hiuemaassa
Resumo:
Summary
Resumo:
Selostus: Maan fosforitilan muutos pitkäaikaisessa kenttäkokeessa hietamaalla
Resumo:
Selostus: Kynnöstä luopumisen ja turvelisäyksen vaikutus savimaan rikkakasvillisuuteen kevätviljakasvustossa
Resumo:
Selostus: Kalkituksen vaikutus piparmintun ja Sachalinin mintun satoon Pohjois-Suomessa
Resumo:
In many industries, such as petroleum production, and the petrochemical, metal, food and cosmetics industries, wastewaters containing an emulsion of oil in water are often produced. The emulsions consist of water (up to 90%), oils (mineral, animal, vegetable and synthetic), surfactants and other contaminates. In view of its toxic nature and its deleterious effects on the surrounding environment (soil, water) such wastewater needs to be treated before release into natural water ways. Membrane-based processes have successfully been applied in industrial applications and are considered as possible candidates for the treatment of oily wastewaters. Easy operation, lower cost, and in some cases, the ability to reduce contaminants below existing pollution limits are the main advantages of these systems. The main drawback of membranes is flux decline due tofouling and concentration polarisation. The complexity of oil-containing systems demands complementary studies on issues related to the mitigation of fouling and concentration polarisation in membranebased ultrafiltration. In this thesis the effect of different operating conditions (factors) on ultrafiltration of oily water is studied. Important factors are normally correlated and, therefore, their effect should be studied simultaneously. This work uses a novel approach to study different operating conditions, like pressure, flow velocity, and temperature, and solution properties, like oil concentration (cutting oil, diesel, kerosene), pH, and salt concentration (CaCl2 and NaCl)) in the ultrafiltration of oily water, simultaneously and in a systematic way using an experimental design approach. A hypothesis is developed to describe the interaction between the oil drops, salt and the membrane surface. The optimum conditions for ultrafiltration and the contribution of each factor in the ultrafiltration of oily water are evaluated. It is found that the effect on permeate flux of the various factors studied strongly depended on the type of oil, the type of membrane and the amount of salts. The thesis demonstrates that a system containing oil is very complex, and that fouling and flux decline can be observed even at very low pressures. This means that only the weak form of the critical flux exists for such systems. The cleaning of the fouled membranes and the influence of different parameters (flow velocity, temperature, time, pressure, and chemical concentration (SDS, NaOH)) were evaluated in this study. It was observed that fouling, and consequently cleaning, behaved differently for the studied membranes. Of the membranes studied, the membrane with the lowest propensity for fouling and the most easily cleaned was the regenerated cellulose membrane (C100H). In order to get more information about the interaction between the membrane and the components of the emulsion, a streaming potential study was performed on the membrane. The experiments were carried out at different pH and oil concentration. It was seen that oily water changed the surface charge of the membrane significantly. The surface charge and the streaming potential during different stages of filtration were measured and analysed being a new method for fouling of oil in this thesis. The surface charge varied in different stages of filtration. It was found that the surface charge of a cleaned membrane was not the same as initially; however, the permeability was equal to that of a virgin membrane. The effect of filtration mode was studied by performing the filtration in both cross-flow and deadend mode. The effect of salt on performance was considered in both studies. It was found that salt decreased the permeate flux even at low concentration. To test the effect of hydrophilicity change, the commercial membranes used in this thesis were modified by grafting (PNIPAAm) on their surfaces. A new technique (corona treatment) was used for this modification. The effect of modification on permeate flux and retention was evaluated. The modified membranes changed their pore size around 33oC resulting in different retention and permeability. The obtained results in this thesis can be applied to optimise the operation of a membrane plant under normal or shock conditions or to modify the process such that it becomes more efficient or effective.
Resumo:
Electrokinetic remediation coupled with Fenton oxidation, widely called as Electrokinetic Fenton process is a potential soil remediation technique used for low permeable soil. The applicability of the process has been proved with soil contaminated with a wide range of organic compounds from phenol to the most recalcitrant ones such as PAHs and POPs. This thesis summarizes the major findings observed during an Electrokinetic Fenton Process study conducted for the remediation of low permeable soil contaminated with HCB, a typical hydrophobic organic contaminant. Model low permeable soil, kaolin, was artificially contaminated with HCB and subjected to Electrokinetic Fenton treatments in a series of laboratory scale batch experiments. The use of cyclodextrins as an enhancement agent to mobilize the sorbed contaminant through the system was investigated. Major process hindrances such as the oxidant availability and treatment duration were also addressed. The HCB degradation along with other parameters like soil pH, redox and cumulative catholyte flow were analyzed and monitored. The results of the experiments strengthen the existing knowledge on electrokinetic Fenton process as a promising technology for the treatment of soil contaminated with hydrophobic organic compounds. It has been demonstrated that HCB sorbed to kaolin can be degraded by the use of high concentrations of hydrogen peroxide during such processes. The overall system performances were observed to be influenced by the point and mode of oxidant delivery. Furthermore, the study contributes to new knowledge in shortening the treatment duration by adopting an electrode polarity reversal during the process.