5 resultados para minimally invasive

em Doria (National Library of Finland DSpace Services) - National Library of Finland, Finland


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Measuring protein biomarkers from sample matrix, such as plasma, is one of the basic tasks in clinical diagnostics. Bioanalytical assays used for the measuring should be able to measure proteins with high sensitivity and specificity. Furthermore, multiplexing capability would also be advantageous. To ensure the utility of the diagnostic test in point-of-care setting, additional requirements such as short turn-around times, ease-ofuse and low costs need to be met. On the other hand, enhancement of assay sensitivity could enable exploiting novel biomarkers, which are present in very low concentrations and which the current immunoassays are unable to measure. Furthermore, highly sensitive assays could enable the use of minimally invasive sampling. In the development of high-sensitivity assays the label technology and affinity binders are in pivotal role. Additionally, innovative assay designs contribute to the obtained sensitivity and other characteristics of the assay as well as its applicability. The aim of this thesis was to study the impact of assay components on the performance of both homogeneous and heterogeneous assays. Applicability of two different lanthanide-based label technologies, upconverting nanoparticles and switchable lanthanide luminescence, to protein detection was explored. Moreover, the potential of recombinant antibodies and aptamers as alternative affinity binders were evaluated. Additionally, alternative conjugation chemistries for production of the labeled binders were studied. Different assay concepts were also evaluated with respect to their applicability to point-of-care testing, which requires simple yet sensitive methods. The applicability of upconverting nanoparticles to the simultaneous quantitative measurement of multiple analytes using imaging-based detection was demonstrated. Additionally, the required instrumentation was relatively simple and inexpensive compared to other luminescent lanthanide-based labels requiring time-resolved measurement. The developed homogeneous assays exploiting switchable lanthanide luminescence were rapid and simple to perform and thus applicable even to point-ofcare testing. The sensitivities of the homogeneous assays were in the picomolar range, which are still inadequate for some analytes, such as cardiac troponins, requiring ultralow limits of detection. For most analytes, however, the obtained limits of detection were sufficient. The use of recombinant antibody fragments and aptamers as binders allowed site-specific and controlled covalent conjugation to construct labeled binders reproducibly either by using chemical modification or recombinant technology. Luminescent lanthanide labels were shown to be widely applicable for protein detection in various assay setups and to contribute assay sensitivity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Selostus: Tulokastuholaiset ja kasvinsuojelu : taloudellinen näkökulma

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cardiac troponins (cTn) I and T are the current golden standard biochemical markers in the diagnosis and risk stratification of patients with suspected acute coronary syndrome. During the past few years, novel assays capable of detecting cTn‐concentrations in >50% of apparently healthy individuals have become readily available. With the emerging of these high sensitivity cTn assays, reductions in the assay specificity have caused elevations in the measured cTn levels that do not correlate with the clinical picture of the patient. The increased assay sensitivity may reveal that various analytical interference mechanisms exist. This doctoral thesis focused on developing nanoparticle‐assisted immunometric assays that could possibly be applied to an automated point‐of‐care system. The main objective was to develop minimally interference‐prone assays for cTnI by employing recombinant antibody fragments. Fast 5‐ and 15‐minute assays for cTnI and D‐dimer, a degradation product of fibrin, based on intrinsically fluorescent nanoparticles were introduced, thus highlighting the versatility of nanoparticles as universally applicable labels. The utilization of antibody fragments in different versions of the developed cTnI‐assay enabled decreases in the used antibody amounts without sacrificing assay sensitivity. In addition, the utilization of recombinant antibody fragments was shown to significantly decrease the measured cTnI concentrations in an apparently healthy population, as well as in samples containing known amounts of potentially interfering factors: triglycerides, bilirubin, rheumatoid factors, or human anti‐mouse antibodies. When determining the specificity of four commercially available antibodies for cTnI, two out of the four cross‐reacted with skeletal troponin I, but caused crossreactivity issues in patient samples only when paired together. In conclusion, the results of this thesis emphasize the importance of careful antibody selection when developing cTnI assays. The results with different recombinant antibody fragments suggest that the utilization of antibody fragments should strongly be encouraged in the immunoassay field, especially with analytes such as cTnI that require highly sensitive assay approaches.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Metastasis is the main cause of death among cancer patients. In order to initiate the metastatic cascade cancer cells have to undergo epithelial-to-mesenchymal transition (EMT). In EMT epithelial cells lose their cell-cell and cell-extracellular matrix (ECM) contacts and become more motile. The expression of the transcription factor Slug and of the mesenchymal intermediate filament vimentin is induced during EMT. Vimentin is often overexpressed in malignant epithelial cancers but the functional role of vimentin remains incompletely understood. In addition, kinases such as AKT and ERK are known to be involved in the regulation of EMT and cancer cell motility but the mechanisms underlining their functions are often unclear. Integrins are heterodimeric receptors that attach cells to the surrounding tissue and participate in regulating cell migration and invasion. Changes in integrin activity are linked to increased cell motility and further cancer metastasis. The aim for my PhD studies was to investigate the role of cellular signalling pathways and vimentin in the regulation of cancer cell motility and EMT. Our results revealed that in prostate cancer the downregulation of AKT1 and AKT2, but not AKT3, induces activation of cell surface 1-integrins leading to enhanced cell adhesion, migration and invasion. In addition, our findings demonstrated a reciprocal regulatory interaction between vimentin and ERK2 facilitating ERK-mediated phosphorylation of Slug at serine-87 (S87) in breast cancer. Surprisingly, Slug S87 phosphorylation is dispensable for E-cadherin repression but essential for the induction of vimentin and Axl expression in early onset of EMT. Our findings reveal previously unknown mechanistic information of how prostate and breast cancer cell motility and disease progression is regulated