42 resultados para energy conversion system
em Doria (National Library of Finland DSpace Services) - National Library of Finland, Finland
Resumo:
This Master's thesis deals with a Micro Scale Wind Wind Turbine application. The thesis consists of nine chapters. The first chapter is an introduction to the philosophy of a small scale wind turbine application. The second defines concepts, and lists the requirements. The third presents the whole application for an On-Grid , and for an Off-Grid arrangement, with main concentration on lighting, heating, and energy storage. The fourth deals with the Inverter's technology, which are used for the conversion of the produced power. The fifth chapter presents the available storage technology and it's possibilities. The sixth deals with the system, and the technological means used for the implementation. The seventh presents the PLC device, which was used as the controller for the management of the whole application. The eighth deals with the concept and the control application philosophy that the PLC involves. And the final chapter presents conclusions and ideas for further considerations.
Resumo:
This thesis studies the possibilities to recover energy in a hydraulic forklift system. Controlling of the system is done directly with an electric servo motor drive and a hydraulic pump. A real system was built and tested and simulations of the system were made with Matlab. Results of the system and simulations were analysed and compared and according to them, energy can be recovered efficiently from the hydraulic forklift system. Also new ideas and directions of further research were obtained with the help of this research.
Resumo:
Recent developments in power electronics technology have made it possible to develop competitive and reliable low-voltage DC (LVDC) distribution networks. Further, islanded microgrids—isolated small-scale localized distribution networks— have been proposed to reliably supply power using distributed generations. However, islanded operations face many issues such as power quality, voltage regulation, network stability, and protection. In this thesis, an energy management system (EMS) that ensures efficient energy and power balancing and voltage regulation has been proposed for an LVDC island network utilizing solar panels for electricity production and lead-acid batteries for energy storage. The EMS uses the master/slave method with robust communication infrastructure to control the production, storage, and loads. The logical basis for the EMS operations has been established by proposing functionalities of the network components as well as by defining appropriate operation modes that encompass all situations. During loss-of-powersupply periods, load prioritizations and disconnections are employed to maintain the power supply to at least some loads. The proposed EMS ensures optimal energy balance in the network. A sizing method based on discrete-event simulations has also been proposed to obtain reliable capacities of the photovoltaic array and battery. In addition, an algorithm to determine the number of hours of electric power supply that can be guaranteed to the customers at any given location has been developed. The successful performances of all the proposed algorithms have been demonstrated by simulations.
Resumo:
The amount of installed wind power has been growing exponentially during the past ten years. As wind turbines have become a significant source of electrical energy, the interactions between the turbines and the electric power network need to be studied more thoroughly than before. Especially, the behavior of the turbines in fault situations is of prime importance; simply disconnecting all wind turbines from the network during a voltage drop is no longer acceptable, since this would contribute to a total network collapse. These requirements have been a contributor to the increased role of simulations in the study and design of the electric drive train of a wind turbine. When planning a wind power investment, the selection of the site and the turbine are crucial for the economic feasibility of the installation. Economic feasibility, on the other hand, is the factor that determines whether or not investment in wind power will continue, contributing to green electricity production and reduction of emissions. In the selection of the installation site and the turbine (siting and site matching), the properties of the electric drive train of the planned turbine have so far been generally not been taken into account. Additionally, although the loss minimization of some of the individual components of the drive train has been studied, the drive train as a whole has received less attention. Furthermore, as a wind turbine will typically operate at a power level lower than the nominal most of the time, efficiency analysis in the nominal operating point is not sufficient. This doctoral dissertation attempts to combine the two aforementioned areas of interest by studying the applicability of time domain simulations in the analysis of the economicfeasibility of a wind turbine. The utilization of a general-purpose time domain simulator, otherwise applied to the study of network interactions and control systems, in the economic analysis of the wind energy conversion system is studied. The main benefits of the simulation-based method over traditional methods based on analytic calculation of losses include the ability to reuse and recombine existing models, the ability to analyze interactions between the components and subsystems in the electric drive train (something which is impossible when considering different subsystems as independent blocks, as is commonly done in theanalytical calculation of efficiencies), the ability to analyze in a rather straightforward manner the effect of selections other than physical components, for example control algorithms, and the ability to verify assumptions of the effects of a particular design change on the efficiency of the whole system. Based on the work, it can be concluded that differences between two configurations can be seen in the economic performance with only minor modifications to the simulation models used in the network interaction and control method study. This eliminates the need ofdeveloping analytic expressions for losses and enables the study of the system as a whole instead of modeling it as series connection of independent blocks with no lossinterdependencies. Three example cases (site matching, component selection, control principle selection) are provided to illustrate the usage of the approach and analyze its performance.
Resumo:
In this work mathematical programming models for structural and operational optimisation of energy systems are developed and applied to a selection of energy technology problems. The studied cases are taken from industrial processes and from large regional energy distribution systems. The models are based on Mixed Integer Linear Programming (MILP), Mixed Integer Non-Linear Programming (MINLP) and on a hybrid approach of a combination of Non-Linear Programming (NLP) and Genetic Algorithms (GA). The optimisation of the structure and operation of energy systems in urban regions is treated in the work. Firstly, distributed energy systems (DES) with different energy conversion units and annual variations of consumer heating and electricity demands are considered. Secondly, district cooling systems (DCS) with cooling demands for a large number of consumers are studied, with respect to a long term planning perspective regarding to given predictions of the consumer cooling demand development in a region. The work comprises also the development of applications for heat recovery systems (HRS), where paper machine dryer section HRS is taken as an illustrative example. The heat sources in these systems are moist air streams. Models are developed for different types of equipment price functions. The approach is based on partitioning of the overall temperature range of the system into a number of temperature intervals in order to take into account the strong nonlinearities due to condensation in the heat recovery exchangers. The influence of parameter variations on the solutions of heat recovery systems is analysed firstly by varying cost factors and secondly by varying process parameters. Point-optimal solutions by a fixed parameter approach are compared to robust solutions with given parameter variation ranges. In the work enhanced utilisation of excess heat in heat recovery systems with impingement drying, electricity generation with low grade excess heat and the use of absorption heat transformers to elevate a stream temperature above the excess heat temperature are also studied.
Resumo:
Forest biomass represents a geographically distributed feedstock, and geographical location affects the greenhouse gas (GHG) performance of a given forest-bioenergy system in several ways. For example, biomass availability, forest operations, transportation possibilities and the distances involved, biomass end-use possibilities, fossil reference systems, and forest carbon balances all depend to some extent on location. The overall objective of this thesis was to assess the GHG emissions derived from supply and energy-utilization chains of forest biomass in Finland, with a specific focus on the effect of location in relation to forest biomass’s availability and the transportation possibilities. Biomass availability and transportation-network assessments were conducted through utilization of geographical information system methods, and the GHG emissions were assessed by means of lifecycle assessment. The thesis is based on four papers in which forest biomass supply on industrial scale was assessed. The feedstocks assessed in this thesis include harvesting residues, smalldiameter energy wood and stumps. The principal implication of the findings in this thesis is that in Finland, the location and availability of biomass in the proximity of a given energyutilization or energy-conversion plant is not a decisive factor in supply-chain GHG emissions or the possible GHG savings to be achieved with forest-biomass energy use. Therefore, for the greatest GHG reductions with limited forest-biomass resources, energy utilization of forest biomass in Finland should be directed to the locations where most GHG savings are achieved through replacement of fossil fuels. Furthermore, one should prioritize the types of forest biomass with the lowest direct supply-chain GHG emissions (e.g., from transport and comminution) and the lowest indirect ones (in particular, soil carbon-stock losses), regardless of location. In this respect, the best combination is to use harvesting residues in combined heat and power production, replacing peat or coal.
Resumo:
The general striving to bring down the number of municipal landfills and to increase the reuse and recycling of waste-derived materials across the EU supports the debates concerning the feasibility and rationality of waste management systems. Substantial decrease in the volume and mass of landfill-disposed waste flows can be achieved by directing suitable waste fractions to energy recovery. Global fossil energy supplies are becoming more and more valuable and expensive energy sources for the mankind, and efforts to save fossil fuels have been made. Waste-derived fuels offer one potential partial solution to two different problems. First, waste that cannot be feasibly re-used or recycled is utilized in the energy conversion process according to EU’s Waste Hierarchy. Second, fossil fuels can be saved for other purposes than energy, mainly as transport fuels. This thesis presents the principles of assessing the most sustainable system solution for an integrated municipal waste management and energy system. The assessment process includes: · formation of a SISMan (Simple Integrated System Management) model of an integrated system including mass, energy and financial flows, and · formation of a MEFLO (Mass, Energy, Financial, Legislational, Other decisionsupport data) decision matrix according to the selected decision criteria, including essential and optional decision criteria. The methods are described and theoretical examples of the utilization of the methods are presented in the thesis. The assessment process involves the selection of different system alternatives (process alternatives for treatment of different waste fractions) and comparison between the alternatives. The first of the two novelty values of the utilization of the presented methods is the perspective selected for the formation of the SISMan model. Normally waste management and energy systems are operated separately according to the targets and principles set for each system. In the thesis the waste management and energy supply systems are considered as one larger integrated system with one primary target of serving the customers, i.e. citizens, as efficiently as possible in the spirit of sustainable development, including the following requirements: · reasonable overall costs, including waste management costs and energy costs; · minimum environmental burdens caused by the integrated waste management and energy system, taking into account the requirement above; and · social acceptance of the selected waste treatment and energy production methods. The integrated waste management and energy system is described by forming a SISMan model including three different flows of the system: energy, mass and financial flows. By defining the three types of flows for an integrated system, the selected factor results needed in the decision-making process of the selection of waste management treatment processes for different waste fractions can be calculated. The model and its results form a transparent description of the integrated system under discussion. The MEFLO decision matrix has been formed from the results of the SISMan model, combined with additional data, including e.g. environmental restrictions and regional aspects. System alternatives which do not meet the requirements set by legislation can be deleted from the comparisons before any closer numerical considerations. The second novelty value of this thesis is the three-level ranking method for combining the factor results of the MEFLO decision matrix. As a result of the MEFLO decision matrix, a transparent ranking of different system alternatives, including selection of treatment processes for different waste fractions, is achieved. SISMan and MEFLO are methods meant to be utilized in municipal decision-making processes concerning waste management and energy supply as simple, transparent and easyto- understand tools. The methods can be utilized in the assessment of existing systems, and particularly in the planning processes of future regional integrated systems. The principles of SISMan and MEFLO can be utilized also in other environments, where synergies of integrating two (or more) systems can be obtained. The SISMan flow model and the MEFLO decision matrix can be formed with or without any applicable commercial or free-of-charge tool/software. SISMan and MEFLO are not bound to any libraries or data-bases including process information, such as different emission data libraries utilized in life cycle assessments.
Resumo:
Ambitious energy targets set by EU put pressures to increase share of renewable electricity supply in this and next decades and therefore, some EU member countries have boosted increasing renewable energy generation capacity by implementing subsidy schemes on national level. In this study, two different change approaches to increase renewable energy supply and increase self-sufficiency of supply are assessed with respect to their impacts on power system, electricity market and electricity generation costs in Finland. It is obtained that the current electricity generation costs are high compared to opportunities of earnings from present-day investor’s perspective. In addition, the growth expectations of consumptions and the price forecasts do not stimulate investing in new generation capacity. Revolutionary transition path is driven by administrative and political interventions to achieve the energy targets. Evolutionary transition path is driven by market-based mechanisms, such as market itself and emission trading scheme. It is obtained in this study that in the revolutionary transition path operation of market-based mechanisms is distorted to some extent and it is likely that this path requires providing more public financial resources compared to evolutionary transition path. In the evolutionary transition path the energy targets are not achieved as quickly but market-based mechanisms function better and investment environment endures more stable compared to revolutionary transition path.
Resumo:
An electric system based on renewable energy faces challenges concerning the storage and utilization of energy due to the intermittent and seasonal nature of renewable energy sources. Wind and solar photovoltaic power productions are variable and difficult to predict, and thus electricity storage will be needed in the case of basic power production. Hydrogen’s energetic potential lies in its ability and versatility to store chemical energy, to serve as an energy carrier and as feedstock for various industries. Hydrogen is also used e.g. in the production of biofuels. The amount of energy produced during hydrogen combustion is higher than any other fuel’s on a mass basis with a higher-heating-value of 39.4 kWh/kg. However, even though hydrogen is the most abundant element in the universe, on Earth most hydrogen exists in molecular forms such as water. Therefore, hydrogen must be produced and there are various methods to do so. Today, the majority hydrogen comes from fossil fuels, mainly from steam methane reforming, and only about 4 % of global hydrogen comes from water electrolysis. Combination of electrolytic production of hydrogen from water and supply of renewable energy is attracting more interest due to the sustainability and the increased flexibility of the resulting energy system. The preferred option for intermittent hydrogen storage is pressurization in tanks since at ambient conditions the volumetric energy density of hydrogen is low, and pressurized tanks are efficient and affordable when the cycling rate is high. Pressurized hydrogen enables energy storage in larger capacities compared to battery technologies and additionally the energy can be stored for longer periods of time, on a time scale of months. In this thesis, the thermodynamics and electrochemistry associated with water electrolysis are described. The main water electrolysis technologies are presented with state-of-the-art specifications. Finally, a Power-to-Hydrogen infrastructure design for Lappeenranta University of Technology is presented. Laboratory setup for water electrolysis is specified and factors affecting its commissioning in Finland are presented.
Electromagnetic and thermal design of a multilevel converter with high power density and reliability
Resumo:
Electric energy demand has been growing constantly as the global population increases. To avoid electric energy shortage, renewable energy sources and energy conservation are emphasized all over the world. The role of power electronics in energy saving and development of renewable energy systems is significant. Power electronics is applied in wind, solar, fuel cell, and micro turbine energy systems for the energy conversion and control. The use of power electronics introduces an energy saving potential in such applications as motors, lighting, home appliances, and consumer electronics. Despite the advantages of power converters, their penetration into the market requires that they have a set of characteristics such as high reliability and power density, cost effectiveness, and low weight, which are dictated by the emerging applications. In association with the increasing requirements, the design of the power converter is becoming more complicated, and thus, a multidisciplinary approach to the modelling of the converter is required. In this doctoral dissertation, methods and models are developed for the design of a multilevel power converter and the analysis of the related electromagnetic, thermal, and reliability issues. The focus is on the design of the main circuit. The electromagnetic model of the laminated busbar system and the IGBT modules is established with the aim of minimizing the stray inductance of the commutation loops that degrade the converter power capability. The circular busbar system is proposed to achieve equal current sharing among parallel-connected devices and implemented in the non-destructive test set-up. In addition to the electromagnetic model, a thermal model of the laminated busbar system is developed based on a lumped parameter thermal model. The temperature and temperature-dependent power losses of the busbars are estimated by the proposed algorithm. The Joule losses produced by non-sinusoidal currents flowing through the busbars in the converter are estimated taking into account the skin and proximity effects, which have a strong influence on the AC resistance of the busbars. The lifetime estimation algorithm was implemented to investigate the influence of the cooling solution on the reliability of the IGBT modules. As efficient cooling solutions have a low thermal inertia, they cause excessive temperature cycling of the IGBTs. Thus, a reliability analysis is required when selecting the cooling solutions for a particular application. The control of the cooling solution based on the use of a heat flux sensor is proposed to reduce the amplitude of the temperature cycles. The developed methods and models are verified experimentally by a laboratory prototype.
Resumo:
The issue of energy efficiency is attracting more and more attention of academia, business and policy makers worldwide due to increasing environmental concerns, depletion of non-renewable energy resources and unstable energy prices. The significant importance of energy efficiency within gold mining industry is justified by considerable energy intensity of this industry as well as by the high share of energy costs in the total operational costs. In the context of increasing industrial energy consumption energy efficiency improvement may provide significant energy savings and reduction of CO2 emission that is highly important in order to contribute to the global goal of sustainability. The purpose of this research is to identify the ways of energy efficiency improvement relevant for a gold mining company. The study implements single holistic case study research strategy focused on a Russian gold mining company. The research involves comprehensive analysis of company’s energy performance including analysis of energy efficiency and energy management practices. This study provides following theoretical and managerial contributions. Firstly, it proposes a methodology for comparative analysis of energy performance of Russian and foreign gold mining companies. Secondly, this study provides comprehensive analysis of main energy efficiency challenges relevant for a Russian gold mining company. Finally, in order to overcome identified challenges this research conceives a guidance for a gold mining company for implementation of energy management system based on the ISO standard.
Resumo:
Transmission system operators and distribution system operators are experiencing new challenges in terms of reliability, power quality, and cost efficiency. Although the potential of energy storages to face those challenges is recognized, the economic implications are still obscure, which introduce the risk into the business models. This thesis aims to investigate the technical and economic value indicators of lithium-ion battery energy storage systems (BESS) in grid-scale applications. In order to do that, a comprehensive performance lithium-ion BESS model with degradation effects estimation is developed. The model development process implies literature review on lifetime modelling, use, and modification of previous study progress, building the additional system parts and integrating it into a complete tool. The constructed model is capable of describing the dynamic behavior of the BESS voltage, state of charge, temperature and capacity loss. Five control strategies for BESS unit providing primary frequency regulation are implemented, in addition to the model. The questions related to BESS dimensioning and the end of life (EoL) criterion are addressed. Simulations are performed with one-month real frequency data acquired from Fingrid. The lifetime and cost-benefit analysis of the simulation results allow to compare and determine the preferable control strategy. Finally, the study performs the sensitivity analysis of economic profitability with variable size, EoL and system price. The research reports that BESS can be profitable in certain cases and presents the recommendations.
Resumo:
Diplomityön tavoitteena oli tutkia UPM-Kymmene Oyj:n keskusvalvomossa tapahtuvaa vesivoiman ajosuunnittelua. Pääkohdat tarkastelussa olivat vesistöjen säännöstely, erilaiset vesivuodet ja sähkömarkkinatilanteet. Vesivoiman ajosuunnittelua tarkasteltiin pääasiassa erilaisten vesivuosien ja sähkömarkkinatilanteiden näkökulmasta. Lähtötietoina käytettiin Suomen ympäristökeskuksen vesistömallijärjestelmän ja UPM-Kymmene Oyj:n energianhallintajärjestelmän numeerisia historia-arvoja. Työssäselvitettiin UPM-Kymmene Oyj:n vesivarannoista hyödynnettävissä olevat energiamäärät. Energiamäärien avulla määritettiin skenaario UPM-Kymmene Oyj:n vesivoimantuotannon vaihtelusta. Lisäksi tarkasteltiin vesivoimaa sähkötaseen säätövoimana. Teoreettisessa osassa perehdyttiin Suomen sähköntuotantorakenteeseen, vesivoiman asemaan sähköntuotannossa ja vesivoiman ohjausmekanismeihin. Lisäksi tarkasteltiin UPM-Kymmene Oyj:n sähkön käyttöä ja vesivarantoja. Soveltavassa osassa tarkasteltiin, miten vesivoiman ohjausmekanismit toimivat käytännössä. Lisäksi analysoitiin sähkömarkkinatilanteiden vaikutuksia ja vesivoimalaitosten ajon tehostamismahdollisuuksia. Työn tuloksena laadittiin ennuste-simulaattori, jolla voidaan optimoida vesivoimanja lauhdevoiman ajoa. Tulevaisuudessa simulaattorin avulla voidaan ennustaa poikkeuksellisia sähkömarkkinatilanteita.
Resumo:
Diplomityö on tehty UPM-Kymmene Oyj, Kaukaan tehtailla Lappeenrannassa. Integroidussa metsäteollisuudessa energiantuotanto koostuu yleensä sähkön- ja lämmöntuotannosta. Kaukaan tehtailla prosessien lämmöntarve saadaan katettua kokonaisuudessaan omalla tuotannolla, kun taas kulutetusta sähköstä ainoastaan puolet on tuotettu itse. Loput sähköntarpeesta joudutaan ostamaan ulkopuolelta. Tutkimuksen pääpaino on ollut selvittää, miten kustannukset ovat riippuvaisia energiantuotannosta erilaisissa käyttöolosuhteissa. Työn tuloksena on luotu tietokonepohjainen laskentamalli, jonka avulla Kaukaan tehtaiden energiantuotantoa voidaan ohjata taloudellisesti optimaalisimmalla tavalla kulloinkin vallitsevassa käyttötilanteessa. Lisäksi tutkimuksessa on analysoitu tehdasintegraatin lämmönkulutuksen seurannan mahdollisuuksia lämmönsiirtoverkon nykyisten mittausten perusteella. Työssä on kerrottu yleisesti metsäteollisuuden energiankulutuksesta Suomessa. Lisäksi on esitetty arvioita energiankulutuksen kehityksestä tulevaisuudessa sekä keinoja energiatehokkuuden parantamiseksi. Kaukaan tehtailla lämmönkulutuksen seurantaan käytettävät mittausmenetelmät ja -laitteet on esitelty virtausmittausten osalta sekä arvioitu nykyisten mittausten luotettavuutta ja riittävyyttä kokonaisvaltaisen lämpötaseen hallintaan. Kaukaan tehtaiden energiantuotantojärjestelmästä on luotu termodynaaminen malli, johon energiantuotannosta aiheutuneiden kustannusten laskenta perustuu. Energiantuotannon optimoinnilla pyritään määrittelemään tietyn tarkasteluhetken käyttötilanteessa taloudellisesti optimaalisin kattiloiden ajojärjestys. Tarkastelu on rajattu lämmöntuotannon lisäämisen osalta maakaasun käytön lisäämiseen ja höyryturbiinien ohitukseen. Sähkön ja maakaasun hinnan sekä ympäristön lämpötilan vaihtelujen vaikutusta optimaaliseen ajojärjestykseen on havainnollistettu esimerkkien avulla.
Resumo:
Empower Oy on energia-alan palveluja tarjoava yritys. Energianhallintajärjestelmää käytetään energiatietojen hallintaan ja ylläpitoon sekä tietojen esittämiseen loppukäyttäjille. Palvelun näytöt ja raportit on toteutettu web-pohjaisen käyttöliittymän kautta. Yhtiössä käynnistyi suurprojekti vanhan energianhallintajärjestelmän korvaamiseksi. Vanha järjestelmä otettiin käyttöön vuonna 1995 ja EMS-projekti käynnistettiin vuonna 2001. Diplomityö tehtiin osana EMS-projektia ja työn tavoitteina oli selvittää perusjärjestelmän käyttämän tietokantaratkaisun toimivuutta ja soveltuvuutta tehtävään sekä tutkailla eri tietokantamalleja teoreettisesti. Lisäksi työhön kuului erillisten haku- ja muutoskomponenttien ja rajapintojen toteuttaminen. Näiden avulla voidaan hakea ja muuttaa tietoa perusjärjestelmän pohjalla toimivasta oliorelaatiotietokannasta. Perusjärjestelmän DOR-tietokannaksi (Domain Object Repository) kutsuttu kokonaisuus on olioläheinen tietovarasto, josta tietoa haetaan ilmoittamalla haettavan olion tyyppi ja siihen liitoksissa olevat tyypit. Hakutulokseen mukaan haluttavat ominaisuudet ilmoitetaan kultakin tyypiltä erikseen. Haettaessa ja muutettaessa oliopohjaista DOR-tietoa, tulee noudattaa järjestelmän käyttämiä tietomalleja. Haku- ja muutoskomponentit toteutettiin Microsoftin kehittämällä .NET-teknologialla. Tietokantamallien teoreettinen tarkastelu auttoi ymmärtämään järjestelmän pohjalla toimivaa tietokantaratkaisua. Työssä selvisi, että perusjärjestelmän hyödyntämä oliorelaatiotietokanta soveltuu varsin hyvin tarkoitukseensa. Haku- ja muutoskomponenttien toteutus onnistui ja ne toimivat helppokäyttöisenä rajapintana energianhallintajärjestelmän tietokantaan.