Resumo:
The thin disk and fiber lasers are new solid-state laser technologies that offer a combinationof high beam quality and a wavelength that is easily absorbed by metal surfacesand are expected to challenge the CO2 and Nd:YAG lasers in cutting of metals ofthick sections (thickness greater than 2mm). This thesis studied the potential of the disk and fiber lasers for cutting applications and the benefits of their better beam quality. The literature review covered the principles of the disk laser, high power fiber laser, CO2 laser and Nd:YAG laser as well as the principle of laser cutting. The cutting experiments were made with thedisk, fiber and CO2 lasers using nitrogen as an assist gas. The test material was austenitic stainless steel of sheet thickness 1.3mm, 2.3mm, 4.3mm and 6.2mm for the disk and fiber laser cutting experiments and sheet thickness of 1.3mm, 1.85mm, 4.4mm and 6.4mm for the CO2 laser cutting experiments. The experiments focused on the maximum cutting speeds with appropriate cut quality. Kerf width, cutedge perpendicularity and surface roughness were the cut characteristics used to analyze the cut quality. Attempts were made to draw conclusions on the influence of high beam quality on the cutting speed and cut quality. The cutting speeds were enormous for the disk and fiber laser cutting experiments with the 1.3mm and 2.3mm sheet thickness and the cut quality was good. The disk and fiber laser cutting speeds were lower at 4.3mm and 6.2mm sheet thickness but there was still a considerable percentage increase in cutting speeds compared to the CO2 laser cutting speeds at similar sheet thickness. However, the cut quality for 6.2mm thickness was not very good for the disk and fiber laser cutting experiments but could probably be improved by proper selection of cutting parameters.
Resumo:
Multispectral images contain information from several spectral wavelengths and currently multispectral images are widely used in remote sensing and they are becoming more common in the field of computer vision and in industrial applications. Typically, one multispectral image in remote sensing may occupy hundreds of megabytes of disk space and several this kind of images may be received from a single measurement. This study considers the compression of multispectral images. The lossy compression is based on the wavelet transform and we compare the suitability of different waveletfilters for the compression. A method for selecting a wavelet filter for the compression and reconstruction of multispectral images is developed. The performance of the multidimensional wavelet transform based compression is compared to other compression methods like PCA, ICA, SPIHT, and DCT/JPEG. The quality of the compression and reconstruction is measured by quantitative measures like signal-to-noise ratio. In addition, we have developed a qualitative measure, which combines the information from the spatial and spectral dimensions of a multispectral image and which also accounts for the visual quality of the bands from the multispectral images.
Resumo:
Control applications of switched mode power supplies have been widely investigated. The main objective ofresearch and development (R&D) in this field is always to find the most suitable control method to be implemented in various DC/DC converter topologies. Inother words, the goal is to select a control method capable of improving the efficiency of the converter, reducing the effect of disturbances (line and load variation), lessening the effect of EMI (electro magnetic interference), and beingless effected by component variation. The main objective of this research work is to study different control methods implemented in switched mode power supplies namely (PID control, hysteresis control, adaptive control, current programmed control, variable structure control (VSC), and sliding mode control (SMC). The advantages and drawbacks of each control method are given. Two control methods, the PID and the SMC are selected and their effects on DC/DC (Buck, Boost, and Buck-Boost) converters are examined. Matlab/SimulinkTM is used to implement PID control method in DC/DC Buck converter and SMC in DC/DC (Buck, and Buck Boost) converters. For the prototype, operational amplifiers (op-amps) are used to implement PID control in DC/DC Buck converter. For SMC op-amps are implemented in DC/DC Buck converter and dSPACETM is used to control the DC/DC Buck-Boost converter. The SMC can be applied to the DC/DC (Buck, Boost, and Buck-Boost) converters. A comparison of the effects of the PID control and the SMC on the DC/DC Buck converter response in steady state, under line variations, load variations, and different component variations is performed. Also the Conducted RF-Emissions between the PID and SMC DC/DC Buck Converter are compared. The thesis shows that, in comparison with the PID control, the SMC provides better steady-state response, better dynamic response, less EMI, inherent order reduction, robustness against system uncertainty disturbances, and an implicit stability proof. Giving a better steady-state and dynamic response, the SMC is implemented in a DC/DC resonant converter. The half-wave zero current switching (HWZCS) DC/DC Buck converter is selected as a converter topology. A general guideline to select the tank component values, needed for the designing of a HWZCS DC/DC Buck, is obtained. The implementation of the SMC to a HWZCS DC/DC Buck converter is analysed. The converter response is investigated in the steady-state region and in the dynamic region.
Resumo:
Diplomityön tavoitteena oli parantaa oliotietokantaan perustuvan mökkivarausjärjestelmän pitkiä vasteaikoja ja epävakaata toimintaa sekä luoda tietokantaperusta uusille toiminnoille. Ratkaisua etsittiin korvaamalla oliotietokanta relaatiotietokannalla. Diplomityö on osa koko varausjärjestelmän uusintaa. Työn teoreettinen osuus käsittelee sekä olio- että relaatiotietokannan rakennetta ja oliomallin muuttamista relaatiomalliksi. Käytännön osassa esitellään relaatiotietokannan luominen vaiheittain ja kerrotaan tietojen siirron periaatteesta. Relaatiotietokannan havaittiin olevan vakaampi ja tehokkaampi vasteajoiltaan. Samoin sen vaatima levytilan ja muistin määrä oli pienempi kuin oliotietokannalla. Lisäksi siihen todettiin uusien järjestelmien liittämisen olevan yksinkertaisempaa.
Resumo:
Frequency converters have started to gain new market areas in the field of motion control applications. The communication and control properties of frequency converters have reached the properties of traditional servo amplifiers during the past few years. In this thesis a motion control system was examined. This particular system consists of frequency converters, permanent magnet synchronous motors and linear belt drives. The properties and prerequisites for packing are discussed. A test setup was build and measurement sets were done to examine the performance of the system. Speed and accuracy measurements were done in all three dimensions. Based on the measurement results applicability of the system for packing industry was evaluated.
Resumo:
Since the introduction of antibiotic agents, the amount and prevalence of Beta-lactam resistant enterobacteria has become an increasing problem. Many enterobacteria are opportunistic pathogens that easily acquire resistance mechanisms and genes, which make the situation menacing. These bacteria have acquired resistance and can hydrolyse extended spectrum cephalosporins and penicillins by producing enzymes called extended-spectrum Beta-lactamases (ESBLs). ESBL-producing bacteria are most commonly found in the gastro-intestinal tract of colonised patients. These resistant strains can be found in both health-care associated and community-acquired isolates. The detection and treatment of infections caused by bacteria producing ESBLs are problematic. This study investigated the genetic basis of extended-spectrum Beta-lactamases in Enterobacteriaceae, especially in Escherichia coli and Klebsiella pneumoniae isolates. A total of 994 Finnish Enterobacteriaceae strains, collected at 26 hospital laboratories, during 2000 and 2007 were analysed. For the genetic basis studies, PCR, sequencing and pyrosequencing methods were optimised. In addition, international standard methods, the agar dilution and disk diffusion methods were performed for the resistance studies, and the susceptibility of these strains was tested for antimicrobial agents that are used for treating patients. The genetic analysis showed that blaCTX-M was the most prevalent gene among the E. coli isolates, while blaSHV-12 was the most common Beta-lactamase gene in K. pneumoniae. The susceptibility testing results showed that about 60% of the strains were multidrug resistant. The prevalence of ESBL-producing isolates in Finland has been increasing since 2000. However, the situation in Finland is still much better than in many other European countries.
Resumo:
This Master's thesis is devoted to semiconductor samples study using time-resolved photoluminescence. This method allows investigating recombination in semiconductor samples in order to develop quality of optoelectronic device. An additional goal was the method accommodation for low-energy-gap materials. The first chapter gives a brief intercourse into the basis of semiconductor physics. The key features of the investigated structures are noted. The usage area of the results covers saturable semiconductor absorber mirrors, disk lasers and vertical-external-cavity surface-emittinglasers. The experiment set-up is described in the second chapter. It is based on up-conversion procedure using a nonlinear crystal and involving the photoluminescent emission and the gate pulses. The limitation of the method was estimated. The first series of studied samples were grown at various temperatures and they suffered rapid thermal annealing. Further, a latticematched and metamorphically grown samples were compared. Time-resolved photoluminescence method was adapted for wavelengths up to 1.5 µm. The results allowed to specify the optimal substrate temperature for MBE process. It was found that the lattice-matched sample and the metamorphically grown sample had similar characteristics.
Resumo:
Tässä työssä tutkitaan D-luokan audiovahvistimen pääteastetopologioiden eroja teknisen toiminnan, käytännön toteutuksen ja audiosignaalin laadun näkökulmista. Tutkimuksen perusteella valitaan yksi topologia kitaravahvistinsovellukseen, jossa modulointi on toteutettu Sigma-Delta-modulaattorilla. Pääteastetopologioiden tekninen toiminta selvitetään yksityiskohtaisesti virtojen kulkureittien avulla. Simulaatioilla tutkitaan suoja-ajan ja tulosignaalin variaatioiden vaikutusta lähtösignaalin kokonaisharmoniseen säröön (THD) ja selvitetään signaalin säröytymiseen vaikuttavien tekijöiden syitä D-luokan vahvistimen pääteasteessa.
Resumo:
Antimicrobial Resistance in Campylobacter jejuni and Campylobacter coli Campylobacters are a common cause of bacterial gastroenteritis worldwide, with Campylobacter jejuni and C. coli being the most common species isolated in human infections. If antimicrobial treatment is required, the drugs of choice at the moment are the macrolides and fluoroquinolones. In this thesis, the in vitro resistance profiles of the C. jejuni and C. coli strains were evaluated with emphasis on multidrug resistance. The aim was also to evaluate the different resistance mechanisms against the macrolides. Further, the disk diffusion method was compared to agar dilution method and its repeatability was evaluated, since it has been widely used for the susceptibility testing of campylobacters. The results of the present study showed that resistance to the fluoroquinolones is common in strains isolated from Finnish patients, but resistance to the macrolides is still rare. Multidrug resistance was associated with resistance to both ciprofloxacin and erythromycin. Among the available per oral drugs, least resistance was observed to coamoxiclav There was no resistance to the carbapenems. Sitafloxacin and tigecycline were in vitro highly effective towards Campylobacter species. A point mutation A2059G of the 23S rRNA gene was the main mechanism behind the macrolide resistance, whereas the efflux pumps did not seem to play an important role when a strain had A2059G mutation. A five amino acids insertion, which has not been described previously, in the ribosomal protein L22 of one highly-resistant C. jejuni strain without mutation in the 23S rRNA gene was also detected. Concerning the disk diffusion method, there was variation in the repeatability In conclusion, macrolides still appear to be the first-choice alternative for suspected Campylobacter enteritis. The in vitro susceptibilities found suggest that co-amoxiclav might be a candidate for clinical trials on campylobacteriosis, but in life-threatening situations, a carbapenem may be the drug of choice. More studies are needed on whether the disk diffusion test method could be improved or whether all susceptibilities of campylobacters should be done using a MIC based method.
Resumo:
Bacteriorhodopsin (BR) is a photosensitive protein which functions as a light-driven proton pump. Due to its photoactivity, BR could be used in photosensing and information processing which has inspired researchers to study the photoelectric response and the appropriate measurement instrumentation for BR. In this thesis, the measurement instrumentation connected to a dry BR sensor was confirmed to affect the photovoltage response measured by using voltage amplifiers. Changing of the input impedance of the measurement instrumentation was shown to alter a part of the measured photovoltage response. The photocurrent measurements using transimpedance amplifier and the presented electrical equivalent circuit were used to show that the photocurrent measurements have no significant effect on the photoelectric response. The photocurrent was shown to be a derivate of the photovoltage response measured from the dry BR sensor when it was compared to the response measured with a voltage amplifier. This confirmed that another part of the photovoltage response was not affected by the measurement instrumentation. The time-variant behavior of the dry BR sensor was confirmed in both the photocurrent and the photovoltage measurements. This was caused by the fact that the capacitance of the dry BR sensor changes with the excitation light intensity.
Resumo:
Erotusvahvistin on instrumentointivahvistin, jonka tulo ja lähtö ovat galvaanisesti erotettu toisistaan. Erotusvahvistimia käytetään galvaanista erotusta vaativissa sovelluksissa, muun muassa sairaalalaitteissa. Teollisuudessa on olemassa sovelluksia, joihin tarvittaisiin analogisia erotusvahvistimia, mutta ei tiedetä onko analogisilla erotusvahvistimilla riittävän hyvät komponenttiarvot. Tässä työssä selvitetään analogisten erotusvahvistimien tämänhetkisiä ominaisuuksia, hintoja ja komponenttiarvoja neljältä eri valmistajalta.
Resumo:
The objective of this thesis was to examine the potential of multi-axis solutions in packaging machines produced in Europe. The definition of a multi-axis solution in this study is a construction that uses a common DC bus power supply for different amplifiers running the axes and the intelligence is centralized into one unit. The cost structure of a packaging machine was gained from an automation research, which divided the machines according to automation categories. The automation categories were then further divided into different sub-components by evaluating the ratio of multi-axis solutions compared to other automation components in packaging machines. A global motion control study was used for further information. With the help of the ratio, an estimation of the potential of multi-axis solutions in each country and packaging machine sector was completed. In addition to the research, a specific questionnaire was sent to five companies to gain information about the present situation and possible trends in packaging machinery. The greatest potential markets are in Germany and Italy, which are also the largest producers of packaging machinery in Europe. The greatest growth in the next few years will be seen in Turkey where the annual growth rate equals the general machinery production rate in Asia. The greatest market potential of the Nordic countries is found in Sweden in 35th position on the list. According to the interviews, motion control products in packaging machines will retain their current power levels, as well as the number of axes in the future. Integrated machine safety features together with a universal programming language are the desired attributes of the future. Unlike generally in industry, the energy saving objectives are and will remain insignificant in the packaging industry.
Resumo:
Fiber-reinforced composites (FRCs) are a new group of non-metallic biomaterials showing a growing popularity in many dental and medical applications. As an oral implant material, FRC is biocompatible in bone tissue environment. Soft tissue integration to FRC polymer material is unclear. This series of in vitro studies aimed at evaluating unidirectional E-glass FRC polymer in terms of mechanical, chemical, and biological properties in an attempt to develop a new non-metallic oral implant abutment alternative. Two different types of substrates were investigated: (a) Plain polymer (BisGMA 50%–TEGDMA 50%) and (b) Unidirectional FRC. The mechanical behavior of high fiber-density FRCs was assessed using a three-point bending test. Surface characterization was performed using scanning electron and spinning disk confocal microscopes. The surface wettability/energy was determined using sessile drop method. The blood response, including blood-clotting ability and platelet morphology was evaluated. Human gingival fibroblast cell responses - adhesion kinetics, adhesion strength, and proliferation activity - were studied in cell culture environment using routine test conditions. A novel tissue culture method was developed and used to evaluate porcine gingival tissue graft attachment and growth on the experimental composite implants. The analysis of the mechanical properties showed that there is a direct proportionality in the relationship between E-glass fiber volume fraction and toughness, modulus of elasticity, and load bearing capacity; however, flexural strength did not show significant improvement when high fiber-density FRC is used. FRCs showed moderate hydrophilic properties owing to the presence of exposed glass fibers on the polymer surface. Blood-clotting time was shorter on FRC substrates than on plain polymer. The FRC substrates also showed higher platelet activation state than plain polymer substrates. Fibroblast cell adhesion strength and proliferation rate were highly pronounced on FRCs. A tissue culture study revealed that gingival epithelium and connective tissue established an immediate close contact with both plain polymer and FRC implants. However, FRC seemed to guide epithelial migration outwards from the tissue/implant interface. Due to the anisotropic and hydrophilic nature of FRC, it can be concluded that this material enhances biological events related with soft tissue integration on oral implant surface.