Power Electronic Converters in Low-Voltage Direct Current Distribution – Analysis and Implementation
Resumo:
Over the recent years, smart grids have received great public attention. Many proposed functionalities rely on power electronics, which play a key role in the smart grid, together with the communication network. However, “smartness” is not the driver that alone motivates the research towards distribution networks based on power electronics; the network vulnerability to natural hazards has resulted in tightening requirements for the supply security, set both by electricity end-users and authorities. Because of the favorable price development and advancements in the field, direct current (DC) distribution has become an attractive alternative for distribution networks. In this doctoral dissertation, power electronic converters for a low-voltage DC (LVDC) distribution system are investigated. These include the rectifier located at the beginning of the LVDC network and the customer-end inverter (CEI) on the customer premises. Rectifier topologies are introduced, and according to the LVDC system requirements, topologies are chosen for the analysis. Similarly, suitable CEI topologies are addressed and selected for study. Application of power electronics into electricity distribution poses some new challenges. Because the electricity end-user is supplied with the CEI, it is responsible for the end-user voltage quality, but it also has to be able to supply adequate current in all operating conditions, including a short-circuit, to ensure the electrical safety. Supplying short-circuit current with power electronics requires additional measures, and therefore, the short-circuit behavior is described and methods to overcome the high-current supply to the fault are proposed. Power electronic converters also produce common-mode (CM) and radio-frequency (RF) electromagnetic interferences (EMI), which are not present in AC distribution. Hence, their magnitudes are investigated. To enable comprehensive research on the LVDC distribution field, a research site was built into a public low-voltage distribution network. The implementation was a joint task by the LVDC research team of Lappeenranta University of Technology and a power company Suur-Savon S¨ahk¨o Oy. Now, the measurements could be conducted in an actual environment. This is important especially for the EMI studies. The main results of the work concern the short-circuit operation of the CEI and the EMI issues. The applicability of the power electronic converters to electricity distribution is demonstrated, and suggestions for future research are proposed.
Resumo:
The demand for electricity is constantly growing in contemporary world and, in the same time, quality and reliability requirements are becoming more rigid. In addition, renewable sources of energy have been widely introduced for power generation, and they create specific challenges for the network. Consequently, new solution for distribution system is required, and Low Voltage Direct Current (LVDC) system is the proposed one. This thesis focuses on the investigation of specific cable features for low voltage direct current (LVDC) distribution system. The LVDC system is public ±750 VDC distribution system, which is currently being developed at Lappeen-ranta University of Technology. The aspects, considered in the thesis, are reliable and economic power transmission in distribution networks and possible power line communication in the LVDC cable.
Resumo:
Perinteisesti sähkönjakelu on toteutettu vaihtosähköjärjestelmänä, mutta varsinkin tehoelektroniikan kehittymisen ja halpenemisen myötä on paljon keskusteltu tasasähköisistä jakelujärjestelmistä. Tässä työssä on tutkittu ja koetettu tuoda esille tasasähkön hyödyntämismahdollisuuksia sähkönjakelussa, sekä erityisesti kiinteistöjen kuten kotien ja toimistojen sähköverkoissa. DC-verkko parantaa mm. järjestelmän luotettavuutta ja jännitteenlaatua. Myös hajautetun energiantuotannon ja energiavarastojen lisääminen sähkövoimajärjestelmään olisi yksinkertaisempaa tasasähköiseen verkkoon. Monet nykyajan kotien ja toimistojen sähkölaitteista olisi nykyiselläänkin ilman modifikaatioita liitettävissä DC-verkkoon. Monien laitteiden sisäinen käyttöjännite on nykyään tasajännitettä kuten esimerkiksi tietokoneiden ja viihde-elektroniikan. Näiden laitteiden tarvitsemissa lukuisissa tasasuuntaajissa hukataan paljon energiaa. Yhdistämällä laitteet DC-verkkoon voitaisiin suuntauksista luopua, jolloin järjestelmän kokonaishyötysuhde paranisi. Lisäksi kiinteistöissä tasajännitteellä voitaisiin hyödyntää entistä paremmin muun muassa aurinkoenergiaa, polttokennoja ja energiavarastoja eli uusiutuvia ja ympäristöystävällisiä energialähteitä.
Resumo:
The research of power-line communications has been concentrated on home automation, broadband indoor communications and broadband data transfer in a low voltage distribution network between home andtransformer station. There has not been carried out much research work that is focused on the high frequency characteristics of industrial low voltage distribution networks. The industrial low voltage distribution network may be utilised as a communication channel to data transfer required by the on-line condition monitoring of electric motors. The advantage of using power-line data transfer is that it does not require the installing of new cables. In the first part of this work, the characteristics of industrial low voltage distribution network components and the pilot distribution network are measured and modelled with respect topower-line communications frequencies up to 30 MHz. The distributed inductances, capacitances and attenuation of MCMK type low voltage power cables are measured in the frequency band 100 kHz - 30 MHz and an attenuation formula for the cables is formed based on the measurements. The input impedances of electric motors (15-250 kW) are measured using several signal couplings and measurement based input impedance model for electric motor with a slotted stator is formed. The model is designed for the frequency band 10 kHz - 30 MHz. Next, the effect of DC (direct current) voltage link inverter on power line data transfer is briefly analysed. Finally, a pilot distribution network is formed and signal attenuation in communication channels in the pilot environment is measured. The results are compared with the simulations that are carried out utilising the developed models and measured parameters for cables and motors. In the second part of this work, a narrowband power-line data transfer system is developed for the data transfer ofon-line condition monitoring of electric motors. It is developed using standardintegrated circuits. The system is tested in the pilot environment and the applicability of the system for the data transfer required by the on-line condition monitoring of electric motors is analysed.
Resumo:
Työssä tutkitaan nopeusanturittoman vaihtovirtakäytön skalaarisia ohjaus- ja säätömenetelmiä. Työn alussa esitetään perusteoriat taajuusmuuttajista ja oikosulkumoottoreista. Tämän jälkeen esitellään yleisimmin kirjallisuudessa esiintyneet skalaariohjaukset ja –säädöt. Vektorisäätöä ja erityisesti moottoriparametrien vaikutusta säädön toimivuuteen esitellään lyhyesti. Työn tavoitteena on ACS800 taajuusmuuttajan skalaarisäädön tutkiminen. ACS800:n nykyinen skalaarisäätö on liian sidoksissa vektorisäätöön, joten simulointien ja kirjallisuustutkimuksen tarkoituksena on täysin vektorisäädöstä eriytetyn skalaarisäädön kehitysmahdollisuuksien tutkiminen. Kirjallisuudessa esiintyneiden säätöjen avulla muodostetaan diskreettiaikainen toteutus skalaarisäädölle vaihtovirtakäytössä, jossa on käytössä virran ja välipiirijännitteen takaisinkytkentä. Säädettävää moottoria mallinnetaan jatkuvaaikaisella L-sijaiskytkennällä. Välipiirin mallinnus toimii myös jatkuva-aikaisena lukuun ottamatta välipiirin tasavirtakomponenttia, joka muodostetaan virran takaisinkytkennän ja PWM-modulaattorin kytkinasentojen avulla. Simuloinnin tarkoituksena on mallintaa skalaarisäädön suurimpia ongelmia, kuten virta- ja välijännitesäätöä. Tuloksista voidaan päätellä, että perussäädöt toimivat moitteettomasti, mutta erityisesti virtasäätöä tulisi kehittää.
Resumo:
Technical analysis of Low Voltage Direct Current (LVDC) distribution systems shows that in LVDC transmission the customer voltage quality is higher. One of the problems in LVDC distribution networks that converters both ends of the DC line are required. Because of the converters produce not pure DC voltage, but some fluctuations as well, the huge electrolytic capacitors are required to reduce voltage distortions in the DC-side. This thesis master’s thesis is focused on calculating required DC-link capacitance for LVDC transmission and estimation of the influence of different parameters on the voltage quality. The goal is to investigate the methods of the DC-link capacitance estimation and location in the transmission line.
Resumo:
Yleisesti sähkönjakelussa käytettyä vaihtosähköä ollaan korvaamassa tasasähköllä pienjänniteverkoissa. Vaihtojännitteeseen verrattuna tasajännitteen käyttö mahdollistaa korkeampien jännitetasojen käytön ja paremman sähkönlaadun ja sitä kautta paremman käyttövarmuuden. Sähköverkossa käytettävien muuntajien ja suuntaajien osalta tarvitaan uudenlaisia rakenteita ja kehitystä, että tasajännitejakelun käyttöönotto olisi mahdollista. Oikeiden ratkaisujen löytämiseksi on tehty jo paljon tutkimusta, mutta valmiita järjestelmiä ei vielä ole laajemmin otettu käyttöön. Tasajänniteverkot tarvitsevat myös ohjauksen, säädön ja valvonnan takia tiedonsiirto-ominaisuuksia. Tietoa on mahdollista siirtää samassa kaapelissa, jota käytetään myös sähkön siirtoon. Haasteita asettavat mm. kaapeliin kytketyminen ja tiedonsiirtokanavassa esiintyvät häiriöt. Työssä muodostetaan malli tiedonsiirtokanavasta, jonka avulla voidaan mallintaa verkon käyttäytymistä eri taajuuksilla sekä simuloida sähköverkkoon muodostettavia tiedonsiirtokanavia.
Resumo:
In the doctoral dissertation, low-voltage direct current (LVDC) distribution system stability, supply security and power quality are evaluated by computational modelling and measurements on an LVDC research platform. Computational models for the LVDC network analysis are developed. Time-domain simulation models are implemented in the time-domain simulation environment PSCAD/EMTDC. The PSCAD/EMTDC models of the LVDC network are applied to the transient behaviour and power quality studies. The LVDC network power loss model is developed in a MATLAB environment and is capable of fast estimation of the network and component power losses. The model integrates analytical equations that describe the power loss mechanism of the network components with power flow calculations. For an LVDC network research platform, a monitoring and control software solution is developed. The solution is used to deliver measurement data for verification of the developed models and analysis of the modelling results. In the work, the power loss mechanism of the LVDC network components and its main dependencies are described. Energy loss distribution of the LVDC network components is presented. Power quality measurements and current spectra are provided and harmonic pollution on the DC network is analysed. The transient behaviour of the network is verified through time-domain simulations. DC capacitor guidelines for an LVDC power distribution network are introduced. The power loss analysis results show that one of the main optimisation targets for an LVDC power distribution network should be reduction of the no-load losses and efficiency improvement of converters at partial loads. Low-frequency spectra of the network voltages and currents are shown, and harmonic propagation is analysed. Power quality in the LVDC network point of common coupling (PCC) is discussed. Power quality standard requirements are shown to be met by the LVDC network. The network behaviour during transients is analysed by time-domain simulations. The network is shown to be transient stable during large-scale disturbances. Measurement results on the LVDC research platform proving this are presented in the work.
Resumo:
Today, renewable energy technologies and modern power electronics have made it feasible to implement low voltage direct current (LVDC) microgrids (MGs) ca-pable to island operation. Such LVDC networks are particularly useful in remote areas. However, there are still pending issues in island operated LVDC MGs like electrical safety and controlled operation, which should be addressed before wide-scale implementation. This thesis is focused on the overall protection of an island operated LVDC network concept, including protection against electrical shocks, mains equipment protection and protection of photovoltaic (PV) power sources and battery energy storage systems (BESSs). The topic is approached through ex-amination of the safety hazards and the appropriate methods to protect against them, comprising considerations for earthing system selection and realisation of the protection system.
Resumo:
Tässä työssä on tutkittu tasasähkönsiirron tuomia mahdollisuuksia sähkönjakelussa, kun pienjännitedirektiivin pienjännitemäärittelyn soveltamista laajennetaan koskemaan vaihtojännitteen lisäksi myös tasajännitettä. Aiemmin tasasähköjärjestelmiä on käytetty ainoastaan sähköistymisen alkuaikoina 1900-luvun alussa. Viime vuosikymmeninä on sähkönjakelussa käytetty pelkästään vaihtosähköverkkoja, koska tehoelektronisten laitteiden korkea hintataso ja tekniset ominaisuudet ovat mahdollistaneet tasasähkön käytön vain suurjännitteellä. Suomalaisten sähkönkäyttö on lisääntynyt muutamalla prosenttiyksiköllä vuosittain ja kasvun taantumista ei ole odotettavissa lähiaikoina. Samaan aikaan yhteiskunta muuttuu jatkuvasti yhä riippuvaisemmaksi sähköstä ja odotukset toteutuvasta sähkönlaadusta ovat jatkuvasti korkeammat. Sähkönlaadun näkökulmasta ilmasto on tuonut aiempia suurempia haasteita sähkön toimitusvarmuudelle, kun myrskyjen aiheuttamat tuhot ovat olleet yhä entisiä suurempia. Toimitusvarmuuden parantamiseksi ovat muutamat vuosikymmenen alun rajut myrskyt johtaneet pohdintaan tulevien haasteiden hoitamiseksi ja edelleen uuden 3-portaiseen 20/1/0,4 kV vaihtosähköjärjestelmän kehittämiseen. Tasasähkönsiirron avulla halutaan tuoda käyttöön niitä hyötyjä, joita järjestelmän vaihdolla on saavutettavissa. Täysimääräisellä tasajännitteen hyödyntämisellä voidaan saavuttaa mm. aiempaa edullisempia investointivaihtoehtoja,parempi sähkönlaatu, parempi hajautetun tuotannon liitettävyys verkkoon ja erilaisten asiakaskohtaisten laitteiden helppo integroitavuus osaksi jakelujärjestelmää. Tämän työn puitteissa on pohdittu sekä teknisiä ratkaisuja että järjestelmän teknistaloudellista käyttöaluetta. Lisäksi on pyritty hahmottamaan eri tekijöiden vaikutuksia sähkönjakeluun.
Resumo:
Pienjännitejakeluverkko Suomessa on toteutettu 400 V:n kolmivaiheisella vaihtosähköllä. Pienestä jännitteestä johtuen 20/0.4 kV:n muuntajat täytyy sijoittaa lähelle kuluttajaa, jotta siirtohäviöt eivät nouse liian suuriksi. Suuremman vaihto- tai tasajännitteen käyttö pienjännitejakelussa kasvattaisi verkon tehonsiirtokapasiteettia ja mahdollistaisi pidempien siirtomatkojen käytön. Käynnissä olevassa tutkimushankkeessa käsitellään vaihtoehtoa, jossa tasajännitettä käytettäisiin 20 kV:n verkon ja kuluttajan välisessä tehonsiirrossa ja kuluttajalla sijaitseva vaihtosuuntaaja muodostaisi tasasähköstä standardien mukaista yksi- tai kolmivaiheista vaihtosähköä. Tässä diplomityössä käsitellään tehoelektroniikan soveltamista kuluttajalle sijoitetussa vaihtosuuntaajassa. Työssä tarkastellaan yksivaiheisia invertteritopologioita, niiden ohjausta ja soveltamista erilaisissa vaihtosuuntaajaratkaisuissa sekä LC- ja LCL-suotimien soveltuvuutta invertterin lähtöjännitteen suodatukseen. Lisäksi esitellään erilaisia rakenneratkaisuja vaihtosuuntauksen toteutukseen ja tarkastellaan näiden järjestelmien vikatilanteita ja sähköturvallisuutta. Lopuksi käsitellään koko järjestelmän häviöitä ja hyötysuhdetta eri suodinkomponenteilla sekä kytkentätaajuuksilla ja esitellään laboratorioprototyyppi. Työssä saatiin selville, että puolisiltainvertteri ei sovellu suurten kondensaattorien vuoksi syöttämään verkkotaajuista kuormaa, vaan joudutaan käyttämään kokosiltainvertteriä. Kokosiltainvertterin ja LC- tai LCL-suotimen käsittävää kokonaisuutta tarkasteltaessa havaittiin, että pienimmät häviöt saavutetaan LC-suotimella 5 %:n ja LCL-suotimella 1 %:n särövaatimuksella. Hyötysuhdekäyrää tarkasteltaessa saatiin sama tulos läpi koko invertterin tehoalueen. Suotimen häviöiden tarkka laskenta on kuitenkin erittäin haasteellista, joten tulokset ovat suuntaa-antavia.
Resumo:
Sähkönjakeluverkkojen kehittäminen nykyistä käyttövarmemmiksi ja taloudellisemmiksi vaatii jatkuvasti uusia ratkaisumalleja. Lupaavaksi tekniikaksi sähkönjakeluverkkojen kehittämisessä on osoittautumassa tasasähkönjakelu tehoelektronisten komponenttien kehittyessä ja hintojen laskiessa samanaikaisesti. Pienjännitedirektiivi mahdollistaa tasajännitteen myötä aiempaa suurempien jännitteiden käytön pienjänniteverkoissa. Tasajännitteen käytöllä voidaan saavuttaa etuja mm. tehonsiirtokyvyssä, sähkönlaadussa, käyttövarmuudessa sekä kustannuksissa. Työssä tehdään yksityiskohtaisia teknistaloudellisia tarkasteluja perinteistä 20/0,4 kV tekniikkaa, 1000 V sähkönjakelua sekä tasasähköjärjestelmiä hyödyntäen ja verrataan näiden järjestelmien kustannuksia ja ominaisuuksia toisiinsa. Tutkimusalueet on valittu Fortum Sähkönsiirto Oy:n maaseutu- ja taajamaverkoista. Työssä pyritään hahmotta-maan teknistaloudellista käyttöaluetta eri tasasähkönjakelujärjestelmille sekä määrittä-mään tasasähkönjakelun käyttöpotentiaali tutkimuskohteena olleissa verkoissa. Lisäksi tutkitaan eri tekijöiden vaikutuksia tasasähköjakelun kannattavuuteen ja käyttövarmuu-teen sekä pyritään tuomaan esiin muitakin tasasähkönjakelujärjestelmien ominaisuuksia.
Resumo:
In general, models of ecological systems can be broadly categorized as ’top-down’ or ’bottom-up’ models, based on the hierarchical level that the model processes are formulated on. The structure of a top-down, also known as phenomenological, population model can be interpreted in terms of population characteristics, but it typically lacks an interpretation on a more basic level. In contrast, bottom-up, also known as mechanistic, population models are derived from assumptions and processes on a more basic level, which allows interpretation of the model parameters in terms of individual behavior. Both approaches, phenomenological and mechanistic modelling, can have their advantages and disadvantages in different situations. However, mechanistically derived models might be better at capturing the properties of the system at hand, and thus give more accurate predictions. In particular, when models are used for evolutionary studies, mechanistic models are more appropriate, since natural selection takes place on the individual level, and in mechanistic models the direct connection between model parameters and individual properties has already been established. The purpose of this thesis is twofold. Firstly, a systematical way to derive mechanistic discrete-time population models is presented. The derivation is based on combining explicitly modelled, continuous processes on the individual level within a reproductive period with a discrete-time maturation process between reproductive periods. Secondly, as an example of how evolutionary studies can be carried out in mechanistic models, the evolution of the timing of reproduction is investigated. Thus, these two lines of research, derivation of mechanistic population models and evolutionary studies, are complementary to each other.
Resumo:
Communications play a key role in modern smart grids. New functionalities that make the grids ‘smart’ require the communication network to function properly. Data transmission between intelligent electric devices (IEDs) in the rectifier and the customer-end inverters (CEIs) used for power conversion is also required in the smart grid concept of the low-voltage direct current (LVDC) distribution network. Smart grid applications, such as smart metering, demand side management (DSM), and grid protection applied with communications are all installed in the LVDC system. Thus, besides remote connection to the databases of the grid operators, a local communication network in the LVDC network is needed. One solution applied to implement the communication medium in power distribution grids is power line communication (PLC). There are power cables in the distribution grids, and hence, they may be applied as a communication channel for the distribution-level data. This doctoral thesis proposes an IP-based high-frequency (HF) band PLC data transmission concept for the LVDC network. A general method to implement the Ethernet-based PLC concept between the public distribution rectifier and the customerend inverters in the LVDC grid is introduced. Low-voltage cables are studied as the communication channel in the frequency band of 100 kHz–30 MHz. The communication channel characteristics and the noise in the channel are described. All individual components in the channel are presented in detail, and a channel model, comprising models for each channel component is developed and verified by measurements. The channel noise is also studied by measurements. Theoretical signalto- noise ratio (SNR) and channel capacity analyses and practical data transmission tests are carried out to evaluate the applicability of the PLC concept against the requirements set by the smart grid applications in the LVDC system. The main results concerning the applicability of the PLC concept and its limitations are presented, and suggestion for future research proposed.