22 resultados para column chromatography

em Doria (National Library of Finland DSpace Services) - National Library of Finland, Finland


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Hawthorn (Crataegus sp.) is widely distributed in the northern hemisphere (Asia, Europe and North America). It has been used as a medicinal material and food for hundreds of years both in Europe and in China. Clinical investigations and other research suggest that extracts of hawthorn fruits and leaves have multiple health effects including hypolipidaemic, anti-atherosclerotic, hypotensive, cardioprotective and blood vessel relaxing activities. Hawthorn fruit extracts have also displayed antioxidant and radical scavenging activities. Emblic leafflower fruit (Phyllanthus emblica) is widely used in Chinese and Indian traditional medicine. It has been found to have anti-cancer, hypoglycaemic and hypolipidaemic activities as well as cardioprotective effects and antioxidant activity. The fruit is currently used as a functional food targeted at obese people in China. Phenolic compounds, procyanidins (PCs), flavonols and C-glycosyl flavones in hawthorn and hydrolysable tannins in emblic leafflower fruits are considered among the major bioactive compounds in these berries. Moreover, hawthorn and emblic leafflower fruits are rich in vitamin C, triterpenoids, fruit acids, sugar alcohols and some other components with beneficial effects on the health of human beings. The aim of the thesis work was to characterise the major phenolic compounds in hawthorn fruits and leaves and emblic leafflower fruits as well as other components contributing to the nutritional profile and sensory properties of hawthorn fruits. Differences in the content and compositional profile of the major phenolic compounds, sugars, acids and sugar alcohols within various origins and species of hawthorn were also investigated. Acids, sugars and sugar alcohols in the fruits of different origins/cultivars belonging to three species (C. pinnatifida, C. brettschneideri and C. scabrifolia) of hawthorn were analysed by gas chromatography (GC-FID) and mass spectrometry (Publication I). Citric acid, quinic acid, malic acid, fructose, glucose, sorbitol and myo-inositol were found in all the subspecies. Sucrose was present only in C. scabrifolia and three cultivars of C. pinnatifida var. major. Forty-two phenolic compounds were identified/tentatively identified in fruits of C. pinnatifida var. major by polyamide column chromatography combined with high-performance liquid chromatograph-electrospray ionisation mass spectrometry (HPLC-ESI-MS) (Publication II). Ideain, chlorogenic acid, procyanidin (PC) B2, (-)-epicatechin, hyperoside and isoquercitrin were the major phenolic components identified. In addition, 35 phenolic compounds were tentatively identified based on UV and mass spectra. Eleven major phenolic compounds (hyperoside, isoquercitrin, chlorogenic acid, ideain, (-)-epicatechin, two PC dimers, three PC trimers and a PC dimer-hexoside) were quantified in the fruits of 22 cultivars/origins of three species of Chinese hawthorn by HPLC-ESI-MS with single ion recording function (SIR) (Publication III). The fruits of the hawthorn cultivars/origins investigated fell into two groups, one rich in sugars and flavonols, the other rich in acids and procyanidins. Based on the compositional features, different biological activities and sensory properties may be expected between cultivars/origins of the two groups. The results suggest that the contents of phenolic compounds, acids, sugars and sugar alcohols may be used as chemotaxonomic information distinguishing the hawthorn species from each other. Phenolic compounds in fruits and leaves of C. grayana and their changes during fruit ripening/harvesting were investigated using HPLC-UV-ESI-MS (Publication IV). (-)-Epicatechin, PC B2 and C1, hyperoside and a quercetin-pentoside were the major phenolic compounds in both fruits and leaves. Three C-glycosyl flavones (a luteolin-C-hexoside, a methyl luteolin-C-hexoside and an apigenin-C-hexoside) were present in leaves in abundance, but only at trace levels in fruits. Ideain and 5-O-caffeoylquinic acid were found in fruits only. Additionally, eleven phenolic compounds were identified/tentatively identified in both leaves and fruits (three B-type PC trimers, two B-type PC tetramers, a quercetin-rhamnosylhexoside, a quercetin-pentoside, a methoxykaempferol-methylpentosylhexoside, a quercetin-hexoside acetate, a methoxykaempferol-pentoside, chlorogenic acid and an unknown hydroxycinnamic acid derivative). The total content of phenolic compounds reached the highest level by the end of August in fruits and by the end of September in leaves. The compositional profiles of phenolic compounds in fruits and leaves of C. grayana were different from those of C. pinnatifida, C. brettschneideri, C. scabrifolia, C. pinnatifida. var. major, C. monogyna, C. laevigata and C. pentagyna. Phenolic compounds in emblic leafflower fruits were characterised by Sephadex LH-20 column chromatography combined with HPLC-ESI-MS (Publication V). A mucic acid gallate, three isomers of mucic acid lactone gallate, a galloylglucose, gallic acid, a digalloylglucose, putranjivain A, a galloyl-HHDP-glucose, elaeocarpusin and chebulagic acid represented the major phenolic compounds in fruits of emblic leafflower. In conclusion, results of this study significantly increase the current knowledge on the key bioactive and nutritional components of hawthorn and emblic leafflower fruits. These results provide important information for research on the mechanism responsible for the health benefits of these fruits.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Preparative liquid chromatography is one of the most selective separation techniques in the fine chemical, pharmaceutical, and food industries. Several process concepts have been developed and applied for improving the performance of classical batch chromatography. The most powerful approaches include various single-column recycling schemes, counter-current and cross-current multi-column setups, and hybrid processes where chromatography is coupled with other unit operations such as crystallization, chemical reactor, and/or solvent removal unit. To fully utilize the potential of stand-alone and integrated chromatographic processes, efficient methods for selecting the best process alternative as well as optimal operating conditions are needed. In this thesis, a unified method is developed for analysis and design of the following singlecolumn fixed bed processes and corresponding cross-current schemes: (1) batch chromatography, (2) batch chromatography with an integrated solvent removal unit, (3) mixed-recycle steady state recycling chromatography (SSR), and (4) mixed-recycle steady state recycling chromatography with solvent removal from fresh feed, recycle fraction, or column feed (SSR–SR). The method is based on the equilibrium theory of chromatography with an assumption of negligible mass transfer resistance and axial dispersion. The design criteria are given in general, dimensionless form that is formally analogous to that applied widely in the so called triangle theory of counter-current multi-column chromatography. Analytical design equations are derived for binary systems that follow competitive Langmuir adsorption isotherm model. For this purpose, the existing analytic solution of the ideal model of chromatography for binary Langmuir mixtures is completed by deriving missing explicit equations for the height and location of the pure first component shock in the case of a small feed pulse. It is thus shown that the entire chromatographic cycle at the column outlet can be expressed in closed-form. The developed design method allows predicting the feasible range of operating parameters that lead to desired product purities. It can be applied for the calculation of first estimates of optimal operating conditions, the analysis of process robustness, and the early-stage evaluation of different process alternatives. The design method is utilized to analyse the possibility to enhance the performance of conventional SSR chromatography by integrating it with a solvent removal unit. It is shown that the amount of fresh feed processed during a chromatographic cycle and thus the productivity of SSR process can be improved by removing solvent. The maximum solvent removal capacity depends on the location of the solvent removal unit and the physical solvent removal constraints, such as solubility, viscosity, and/or osmotic pressure limits. Usually, the most flexible option is to remove solvent from the column feed. Applicability of the equilibrium design for real, non-ideal separation problems is evaluated by means of numerical simulations. Due to assumption of infinite column efficiency, the developed design method is most applicable for high performance systems where thermodynamic effects are predominant, while significant deviations are observed under highly non-ideal conditions. The findings based on the equilibrium theory are applied to develop a shortcut approach for the design of chromatographic separation processes under strongly non-ideal conditions with significant dispersive effects. The method is based on a simple procedure applied to a single conventional chromatogram. Applicability of the approach for the design of batch and counter-current simulated moving bed processes is evaluated with case studies. It is shown that the shortcut approach works the better the higher the column efficiency and the lower the purity constraints are.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dynamic behavior of bothisothermal and non-isothermal single-column chromatographic reactors with an ion-exchange resin as the stationary phase was investigated. The reactor performance was interpreted by using results obtained when studying the effect of the resin properties on the equilibrium and kinetic phenomena occurring simultaneously in the reactor. Mathematical models were derived for each phenomenon and combined to simulate the chromatographic reactor. The phenomena studied includes phase equilibria in multicomponent liquid mixture¿ion-exchange resin systems, chemicalequilibrium in the presence of a resin catalyst, diffusion of liquids in gel-type and macroporous resins, and chemical reaction kinetics. Above all, attention was paid to the swelling behavior of the resins and how it affects the kinetic phenomena. Several poly(styrene-co-divinylbenzene) resins with different cross-link densities and internal porosities were used. Esterification of acetic acid with ethanol to produce ethyl acetate and water was used as a model reaction system. Choosing an ion-exchange resin with a low cross-link density is beneficial inthe case of the present reaction system: the amount of ethyl acetate as well the ethyl acetate to water mole ratio in the effluent stream increase with decreasing cross-link density. The enhanced performance of the reactor is mainly attributed to increasing reaction rate, which in turn originates from the phase equilibrium behavior of the system. Also mass transfer considerations favor the use ofresins with low cross-link density. The diffusion coefficients of liquids in the gel-type ion-exchange resins were found to fall rapidly when the extent of swelling became low. Glass transition of the polymer was not found to significantlyretard the diffusion in sulfonated PS¿DVB ion-exchange resins. It was also shown that non-isothermal operation of a chromatographic reactor could be used to significantly enhance the reactor performance. In the case of the exothermic modelreaction system and a near-adiabatic column, a positive thermal wave (higher temperature than in the initial state) was found to travel together with the reactive front. This further increased the conversion of the reactants. Diffusion-induced volume changes of the ion-exchange resins were studied in a flow-through cell. It was shown that describing the swelling and shrinking kinetics of the particles calls for a mass transfer model that explicitly includes the limited expansibility of the polymer network. A good description of the process was obtained by combining the generalized Maxwell-Stefan approach and an activity model that was derived from the thermodynamics of polymer solutions and gels. The swelling pressure in the resin phase was evaluated by using a non-Gaussian expression forthe polymer chain length distribution. Dimensional changes of the resin particles necessitate the use of non-standard mathematical tools for dynamic simulations. A transformed coordinate system, where the mass of the polymer was used as a spatial variable, was applied when simulating the chromatographic reactor columns as well as the swelling and shrinking kinetics of the resin particles. Shrinking of the particles in a column leads to formation of dead volume on top of the resin bed. In ordinary Eulerian coordinates, this results in a moving discontinuity that in turn causes numerical difficulties in the solution of the PDE system. The motion of the discontinuity was eliminated by spanning two calculation grids in the column that overlapped at the top of the resin bed. The reactive and non-reactive phase equilibrium data were correlated with a model derived from thethermodynamics of polymer solution and gels. The thermodynamic approach used inthis work is best suited at high degrees of swelling because the polymer matrixmay be in the glassy state when the extent of swelling is low.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Antosyaanit ovat luonnossa esiintyvien flavonoidien suurin ryhmä. Niitä on tunnistettu yli 600 erilaista, mutta kuitenkin vain kuusi on luonnossa yleisesti esiintyviä. Eniten antosyaaneja on tummissa marjoissa kuten mustikassa, marja-aroniassa sekä variksenmarjassa. Antosyaaneilla on havaittu monia positiivisiaterveysvaikutuksia kuten antioksidatiivisia, antikarsinogeenisia, sekä antimikrobiaalisia vaikutuksia. Tässä työssä tutkittiin marjojen antosyaanien talteenottoa uuttamalla sekä niiden väkevöintiä. Tavoitteena oli saada mahdollisimman korkea antosyaanien saanto ja hyvä säilyvyys. Antosyaanien analysointi tehtiin nestekromatografisesti käyttäen ODS-2 kolonnia sekä nopeampaa spektrofotometristä pH-eromenetelmää. Tulokset laskettiin syanidiini-3-glukosidina. Antosyaanien väkevöintiä tutkittiin käyttäen erityyppisiä polymeerisiä makrohuokoisia adsorptiohartseja. Väkevöintiä kokeiltiin myös erottamalla epäpuhtauksia antosyaaniuutteesta sekä esikäsittelemällä puristejäännös eri olosuhteissa ennen antosyaanien uuttoa. Kuiva antosyaaniuute sisälsi ennen väkevöintiä noin 50 mg/g antosyaaneja ja väkevöinnin jälkeen yli 300 mg/g. Antosyaanien säilyvyyttä tutkittiin eri lämpötiloissa sekä kuivana että uutteena. Riippumatta säilytysolosuhteista kuivan puhdistetun antosyaanin havaittiin säilyvän hyvin.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this thesis, the sorption and elastic properties of the cation-exchange resins were studied to explain the liquid chromatographic separation of carbohydrates. Na+, Ca2+ and La3+ form strong poly(styrene-co-divinylbenzene) (SCE) as well as Na+ and Ca2+ form weak acrylic (WCE) cation-exchange resins at different cross-link densities were treated within this work. The focus was on the effects of water-alcohol mixtures, mostly aqueous ethanol, and that of the carbohydrates. The carbohydrates examined were rhamnose, xylose, glucose, fructose, arabinose, sucrose, xylitol and sorbitol. In addition to linear chromatographic conditions, non-linear conditions more typical for industrial applications were studied. Both experimental and modeling aspectswere covered. The aqueous alcohol sorption on the cation-exchangers were experimentally determined and theoretically calculated. The sorption model includes elastic parameters, which were obtained from sorption data combined with elasticity measurements. As hydrophilic materials cation-exchangers are water selective and shrink when an organic solvent is added. At a certain deswelling degree the elastic resins go through glass transition and become as glass-like material. Theincreasing cross-link level and the valence of the counterion decrease the sorption of solvent components in the water-rich solutions. The cross-linkage or thecounterions have less effect on the water selectivity than the resin type or the used alcohol. The amount of water sorbed is higher in the WCE resin and, moreover, the WCE resin is more water selective than the corresponding SCE resin. Theincreased aliphatic part of lower alcohols tend to increase the water selectivity, i.e. the resins are more water selective in 2-propanol than in ethanol solutions. Both the sorption behavior of carbohydrates and the sorption differences between carbohydrates are considerably affected by the eluent composition and theresin characteristics. The carbohydrate sorption was experimentally examined and modeled. In all cases, sorption and moreover the separation of carbohydrates are dominated by three phenomena: partition, ligand exchange and size exclusion. The sorption of hydrophilic carbohydrates increases when alcohol is added into the eluent or when carbohydrate is able to form coordination complexes with the counterions, especially with multivalent counterions. Decreasing polarity of the eluent enhances the complex stability. Size exclusion effect is more prominent when the resin becomes tighter or carbohydrate size increases. On the other hand,the elution volumes between different sized carbohydrates decreases with the decreasing polarity of the eluent. The chromatographic separation of carbohydrateswas modeled, using rhamnose and xylose as target molecules. The thermodynamic sorption model was successfully implemented in the rate-based column model. The experimental chromatographic data were fitted by using only one adjustable parameter. In addition to the fitted data also simulated data were generated and utilized in explaining the effect of the eluent composition and of the resin characteristics on the carbohydrate separation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Enantiomeerit ovat yhdisteitä, jotka ovat toistensa peilikuvamuotoja. Enantiomeerien erotusmenetelmiä ovat neste-nesteuutto, kalvotekniikka, kiteytys, kromatografia ja kapillaarielektroforeesi. Nestekromatografinen erotus perustuu joko suoraan erotukseen tai epäsuoraan erotukseen. Kiraaliset stationaarifaasit erottavat yhdisteet kolonnissa suoralla erotuksella. Derivoimattomia aminohappojen enantiomeerejä on erotettu käyttäen ligandinvaihto-, kruunueetteri-, antibiootti- ja polysakkaridistationaarifaaseja. Epäsuora erotus vaatii erotettavan enantiomeeriparin esikäsittelyn ennen kolonnia. Markkinoilta löytyy niukasti preparatiiviseen mittakaavaan soveltuvia enantiomeerien erotusmateriaaleja. Työn kokeellisessa osassa enantiomeerien erotuksia tehtiin sekä analyyttisessä mittakaavassa että preparatiivisessa mittakaavassa. Tutkittavina pääkomponentteina aminohapoista olivat metioniinin, proliinin ja seriinin enantiomeeriparit. Analyyttisessä mittakaavassa kuparimuotoisella ligandinvaihtokolonnilla tehty erotus onnistui erittäin hyvin. Piikkien resoluutioiden arvot vaihtelivat tyypillisesti välillä 2,0-35 ja erotustekijöiden arvot välillä 1,5-30. Parhaiten onnistuttiin erottamaan metioniinin enantiomeerit toisistaan. Prepatatiivisen mittakaavan erotusmateriaalin tutkimus keskittyi materiaalin kokeiluun ja kehitykseen aminohappojen enantiomeerien erotukseen soveltuvaksi. Erotusmateriaalilla onnistuttiin erottamaan aminohappoja toisistaan, mutta aminohappojen enantiomeerien erottumista ei onnistuttu selkeästi havaitsemaan. Erotusmateriaali toimi parhaiten muunnettuna alkaalisissa olosuhteissa kuparimuotoiseksi. Kuparin pysymättömyys erotusmateriaalissa aiheutti kuitenkin ongelmia kokeiden toistettavuuteen.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Teollisessa kromatografiassa kolonnia pyritään kuormittamaan mahdollisimman paljon, jotta saataisiin maksimoitua erotetun komponentin määrä aikayksikköä kohden. Tässä työssä kuormitusta tutkittiin nostamalla syöttöliuoksen, synteettisen melassin, näyteväkevyyttä 80-125 ºC:ssa. Eluenttina oli paineistettu kuumaa vesi ja hartsina vahva Na-muotoinen PS-DVB pohjainen vahva kationinvaihtohartsi. Lämpötilaa nostamalla piikit kapenivat ja tulivat symmetrisemmiksi, erotus nopeutui sekä suola erottui usein paremmin sokereista. Syöttöliuoksen kuiva-ainetta lisättiin asteittain 55 p-% saakka, jolloin ei vielä havaittu ongelmia erotuksessa. Lämpötilassa 125 ºC havaittiin erotuksen aikana kuormituksesta riippumatonta sakkaroosin invertoitumista. Vertailtaessa eri stationäärifaaseja havaittiin Na-muotoisen PS-DVB pohjaisen kationinvaihtohartsin erottavan yleensä sokereita, sokerialkoholeja, oligosakkarideja ja betaiinia lähes poikkeuksetta paremmin alhaisilla pitoisuuksilla kuin neutraalihartsi ja Na-muotoinen zeoliitti. Erottuminen ei yleensä parantunut lämpötilaa nostamalla, mutta piikit kapenivat ja erotus nopeutui. Monosakkaridien erotus huononi 125 ºC:ssa kationinvaihtohartsilla. Tutkittaessa terveysvaikutteisten ksylo-oligosakkaridien soveltuvuutta alikriittiseen erotukseen, niiden havaittiin huomattavasti hydrolysoituvan happamissa olosuhteissa koeputkessa 100 ºC:ssa kahdessa tunnissa. Näytteessä olevien epäpuhtauksien havaittiin katalysoineen hydrolyysiä. Hydrolysoituminen oli hitaampaa neutraaleissa olosuhteissa korotetussa lämpötilassa. Tästä voitiin tehdä johtopäätös, että alikriittiset olosuhteet eivät sovi ksylo-oligosakkaridien erotukseen.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Viime vuosien nopea kehitys on kiihdyttänyt uusien lääkkeiden kehittämisprosessia. Kombinatorinen kemia on tehnyt mahdolliseksi syntetisoida suuria kokoelmia rakenteeltaan toisistaan poikkeavia molekyylejä, nk. kombinatorisia kirjastoja, biologista seulontaa varten. Siinä molekyylien rakenteeseen liittyvä aktiivisuus tutkitaan useilla erilaisilla biologisilla testeillä mahdollisten "osumien" löytämiseksi, joista osasta saatetaan myöhemmin kehittää uusia lääkeaineita. Jotta biologisten tutkimusten tulokset olisivat luotettavia, on syntetisoitujen komponenttien oltava mahdollisimman puhtaita. Tämän vuoksi tarvitaan HTP-puhdistusta korkealaatuisten komponenttien ja luotettavan biologisen tiedon takaamiseksi. Jatkuvasti kasvavat tuotantovaatimukset ovat johtaneet näiden puhdistustekniikoiden automatisointiin ja rinnakkaistamiseen. Preparatiivinen LC/MS soveltuu kombinatoristen kirjastojen nopeaan ja tehokkaaseen puhdistamiseen. Monet tekijät, esimerkiksi erotuskolonnin ominaisuudet sekä virtausgradientti, vaikuttavat preparatiivisen LC/MS puhdistusprosessin tehokkuuteen. Nämä parametrit on optimoitava parhaan tuloksen saamiseksi. Tässä työssä tutkittiin emäksisiä komponentteja erilaisissa virtausolosuhteissa. Menetelmä kombinatoristen kirjastojen puhtaustason määrittämiseksi LC/MS-puhdistuksen jälkeen optimoitiin ja määritettiin puhtaus joillekin komponenteille eri kirjastoista ennen puhdistusta.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Työssä tutkittiin sakkaroosin hydrolyysiä anioninvaihtohartseihin immobilisoidun entsyymin avulla tavoitteena löytää sellainen kantaja-entsyymi -yhdistelmä, jolla konversio halutuiksi lopputuotteiksi olisi mahdollisimman korkea. Työhön valittiin aikaisemmissa laboratoriokokeissa parhaita tuloksia saavuttaneet kantaja-entsyymi -parit. Entsyymeinä oli kaksi nestemäistä Saccharomyces cerevisiae -hiivasta eristettyjä entsyymivalmistetta. Kokeissa käytetyt kantajamateriaalit olivat erilaisia heikkoja anioninvaihtohartseja. Entsyymit immobilisoitiin kantajaan sekoitusreaktorissa ja niiden aktiivisuudet määritettiin sitomisen jälkeen. Hydrolyysikokeet tehtiin jatkuvatoimisessa kiintopetireaktorissa ja lisäksi panos-kokeina tutkittiin ominaisuuksiltaan erilaisten kantajien eroja hydrolyysissä. Reaktio-olosuhteet pidettiin kaikissa kokeissa samoina. Sakkaroosiliuoksen pitoisuus oli 50 p-%, reaktiolämpötila 50 oC ja pH 5. Kiintopetikolonnissa tutkittiin myös sakkaroosi-liuoksen viipymäajan vaikutusta sivutuotteiden syntyyn. Näytteet analysoitiin neste-kromatografilla. Kiintopetikolonnissa lyhimmän viipymäajan (15 min) kokeissa ainoastaan hitaimmilla kantaja-entsyymi -pareilla muodostui sivutuotteita, jotka hydrolyysireaktion edetessä kuitenkin hävisivät. Kun viipymäaikaa kasvatettiin sivutuotteiden synty väheni ja lopulta niitä ei havaittu syntyvän lainkaan. Hydrolyysin edetessä viipymäajan ollessa tarpeeksi pitkä pienet sivutuotekomponentit hävisivät sakkaroosin hajotessa kokonaan glukoosiksi ja fruktoosiksi. Verrattaessa partikkelikoon ja hartsimatriisin vaikutusta samaan entsyymiin sidottuna havaittiin, että niillä kummallakin on vaikutusta sekä sakkaroosin hydrolyysi-nopeuteen että sivutuotteiden muodostumiseen.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The literature part of the work reviews overall Fischer-Tropsch process, Fischer-Tropsch reactors and catalysts. Fundamentals of Fischer-Tropsch modeling are also presented. The emphasis is on the reactor unit. Comparison of the reactors and the catalysts is carried out to choose the suitable reactor setup for the modeling work. The effects of the operation conditions are also investigated. Slurry bubble column reactor model operating with cobalt catalyst is developed by taking into account the mass transfer of the reacting components (CO and H2) and the consumption of the reactants in the liquid phase. The effect of hydrostatic pressure and the change in total mole flow rate in gas phase are taken into account in calculation of the solubilities. The hydrodynamics, reaction kinetics and product composition are determined according to literature. The cooling system and furthermore the required heat transfer area and number of cooling tubes are also determined. The model is implemented in Matlab software. Commercial scale reactor setup is modeled and the behavior of the model is investigated. The possible inaccuraries are evaluated and the suggestions for the future work are presented. The model is also integrated to Aspen Plus process simulation software, which enables the usage of the model in more extensive Fischer-Tropsch process simulations. Commercial scale reactor of diameter of 7 m and height of 30 m was modeled. The capacity of the reactor was calculated to be about 9 800 barrels/day with CO conversion of 75 %. The behavior of the model was realistic and results were in the right range. The highest uncertainty to model was estimated to be caused by the determination of the kinetic rate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bioetanolin tuotanto kiinnostaa monissa maissa johtuen kansainvälisissä sopimuksissa määritellyistä ilmastotavoitteista. Työssä tutkittiin laboratorio-oloissa ioninvaihtohartsien ominaisuuksien ja erotuksen olosuhteiden vaikutusta rikkihapon ja glukoosin kromatografiseen erotukseen. Tehokkaimmaksi hartsiksi osoittautui polysulfonoitu mesohuokoinen vahva kationinvaihtohartsi Finex CS100C. CS100C:lla voitiin erottaa rikkihappoa ja glukoosia tehokkaimmin korkeissa 25 p-% ja 36 p-% glukoosi- ja rikkihappo-pitoisuuksissa. Lisäksi sillä havaittiin suurin tuotto simuloidussa liikkuvassa pedissä. Yhdessä kolonnissa suoritetuissa erotuskokeissa tutkittiin hartsien erotuskykyä rikkihapolle ja glukoosille sekä virtausnopeuden vaikutusta erotukseen lämpötilassa 22 °C. Saatujen tulosten pohjalta valittiin CS11GC, CS16GC ja CS100C tarkempaan isotermin määritykseen ja simulointiin hyvän erotuskyvyn sekä keskinäisten erojen takia. Adsorptioisotermit määritettiin kolonnikokein sekä 22 °C:n että 50 °C:n lämpötilassa. Isotermeistä havaittiin, että tasapaino kiinto- ja liuosfaasien välille saavutetaan rikkihapolla alhaisella 1 cm3/min virtausnopeudella varmemmin kuin suuremmalla 2,5 cm3/min virtausnopeudella. 50 °C:n lämpötilassa hapon ja glukoosin isotermit olivat jyrkempiä kuin 22 °C:n lämpötilassa. Määritettyihin hapon ja sokerin isotermeihin sovitettiin mallit, joiden parametreja käytettiin yksittäisen kolonnin simulointiin. Simuloinnissa oli estimoitavia parametreja yhdellä kolonnilla aineensiirtokertoimet sekä läpäisykäyristä määritetyt isotermiparametrit glukoosille sekä rikkihapolle ja SMB–erotuksessa vyöhykkeiden 2 ja 3 suhteelliset virtausnopeudet. Siirryttäessä lämpötilojen 22 °C ja 50 °C välillä hartsien parametrit muuttuivat sokerille täysin ja hapolle vain aineensiirtokertoimen osalta. CS100C oli tehokkain SMB–erotuksessa korkeimmalla 0,11 cm3/min tuottavuudella 95 %:n saannon saavuttamiseksi 95 % tuotepuhtaudella raffinaatissa ja ekstraktissa.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim of this thesis was to design and manufacture a microdistillation column. The literature review part of this thesis covers stainless steels, material processing and basics about engineering design and distillation. The main focus, however, is on the experimental part. Experimental part is divided into five distinct sections: First part is where the device is introduced and separated into three parts. Secondly the device is designed part by part. It consists mostly of detail problem solving, since the first drawings had already been drawn and the critical dimensions decided. Third part is the manufacture, which was not fully completed since the final assembly was left out of this thesis. Fourth part is the test welding for the device, and its analysis. Finally some ideas for further studies are presented. The main goal of this thesis was accomplished. The device only lacks some final assembly but otherwise it is complete. One thing that became clear during the process was how difficult it is to produce small and precise steel parts with conventional manufacturing methods. Internal stresses within steel plates and thermal distortions can easily ruin small steel structures. Designing appropriate welding jigs is an important task for even simple devices. Laser material processing is a promising tool for this kind of steel processing because of the flexibility, good cutting quality and also precise and low heat input when welding. Next step in this project is the final assembly and the actual distillation tests. The tests will be carried out at Helsinki University of Technology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Batch chromatography is a widely used separation technique in a variety of fields meeting difficult separations. Several technologies for improving the performance of chromatography have been studied, including mixed-recycle steady state recycling (MR-SSR) chromatography. Design of MR-SSR has been commonly limited on 100 % purity constraint cases and empirical work. In this study a predictive design method was used to optimize feed pulse size and design a number of experimental MR-SSR separations for a solution of 20 % sulfuric acid and 100 g/L glucose. The design was under target product fraction purities of 98.7 % for H2SO4 and 95 % for glucose. The experiments indicate a maximum of 59 % increase in sulfuric acid productivity and 82 % increase for glucose when compared to corresponding batch separation. Eluent consumption was lowered by approximately 50 % using recycling chromatography. Within this study the target purities and yields set in design were not completely met, and further optimization of the process is deemed necessary.