8 resultados para chitosan microspheres
em Doria (National Library of Finland DSpace Services) - National Library of Finland, Finland
Resumo:
Adsorbents functionalized with chelating agents are effective in removal of heavy metals from aqueous solutions. Important properties of such adsorbents are high binding affinity as well as regenerability. In this study, aminopolycarboxylic acid, EDTA and DTPA, were immobilized on the surface of silica gel, chitosan, and their hybrid materials to achieve chelating adsorbents for heavy metals such as Co(II), Ni(II), Cd(II), and Pb(II). New knowledge about the adsorption properties of EDTA- and DTPA-functionalizedadsorbents was obtained. Experimental work showed the effectiveness, regenerability, and stability of the studied adsorbents. Both advantages and disadvantages of the adsorbents were evaluated. For example, the EDTA-functionalized chitosan-silica hybrid materials combined the benefits of the silica gel and chitosan while at the same time diminishing their observed drawbacks. Modeling of adsorption kinetics and isotherms is an important step in design process. Therefore, several kinetic and isotherm models were introduced and applied in this work. Important aspects such as effect of error function, data range, initial guess values, and linearization were discussed and investigated. The selection of the most suitable model was conducted by comparing the experimental and simulated data as well as evaluating the correspondence between the theory behind the model and properties of the adsorbent. In addition, modeling of two-component data was conducted using various extended isotherms. Modeling results for both one- and twocomponent systems supported each other. Finally, application testing of EDTA- and DTPA-functionalized adsorbents was conducted. The most important result was the applicability of DTPA-functionalized silica gel and chitosan in the capturing of Co(II) from its aqueous EDTA-chelate. Moreover, these adsorbents were efficient in various solution matrices. In addition, separation of Ni(II) from Co(II) and Ni(II) and Pb(II) from Co(II) and Cd(II) was observed in two- and multimetal systems. Lastly, prior to their analysis, EDTA- and DTPA-functionalized silica gels were successfully used to preconcentrate metal ions from both pure and salty waters
Resumo:
Dissolving cellulose is the first main step in preparing novel cellulosicmaterials. Since cellulosic fibres cannot be easily dissolved in water-based solvents, fibres were pretreated with ethanol-acid solution prior to the dissolution. Solubility and changes on the surface of the fibres were studied with microscopy and capillary viscometry. After the treatment, the cellulose fibres were soluble in alkaline urea-water solvent. The nature of this viscous solution was studied rheologically. Cellulose microspheres were prepared by extruding the alkaline cellulose solution through the needle into an acidic medium. By altering the temperature and acidity of the mediumit was possible to adjust the specific surface area and pore sizes of themicrospheres. A typical skin-core structure was found in all samples. Microspheres were oxidised in order to introduce anionic carboxylic acid groups (AGs). Anionic microspheres are more hydrophilic; their water-uptake increased 25 times after oxidation and they could swell almost to their original state (88%) after drying and shrinking. Swelling was studied in simulated physiological environments, corresponding to stomach acid and intestines (pH 1.2-7.4). Oxidised microspheres were used as a drug carriers. They demonstrated a highmass uniformity, which would enable their use for personalised dosing among different patients, including children. The drug was solidified in microspheres in amorphous form. This enhanced solubility and could be used for more challenging drugs with poor solubility. The pores of themicrospheres also remained open after the drug was loaded and they were dried. Regardless of the swelling, the drug was released at a constant rate in all environments.
Resumo:
Tässä diplomityössä tutkittiin kalvosuodatuksen esikäsittelymenetelmiä ja kalvonpesua. Työn kirjallisuusosassa käsitellään vuon alenemiseen vaikuttavia tekijöitä, esikäsittelymenetelmiä ja kalvonpesua. Kokeellisessa osassa tutkittiin kemiallisten esikäsittelyjen vaikutusta vuon alenemiseen paperitehtaan happaman kiertoveden kirkkaan suodoksen kalvosuodatuksessa. Esikäsittelykemikaalit olivat ympäristöystävällisiä ja paperinvalmistusprosessiin soveltuvia. Lisäksi tutkittiin kalvonpesuaineiden pesutehokkuuksia. Tutkitut esikäsittelyaineet olivat mikrokiteinen kitosaani, karboksimetyyliselluloosa, selluloosa- ja puukuitu sekä kaupallinen antiskalantti. Pesuaineista tutkittiin kolmea kaupallista kalvonpesuainetta, yhtä kalvopesun tehostusainetta sekä peretikkahappoa. Kokeet tehtiin kahdella laboratoriomittakaavaisella kalvosuodattimella. Kalvoina käytettiin kahta nanosuodatus- ja yhtä ultrasuodatuskalvoa. Vuon alenemista tutkittiin suodatuksen aikaisena alenemisena ja vesivuohon verrattavana alenemisena. Esikäsittelyjen vaikutusta erotustehokkuuteen tutkittiin ioni-, johtokyky-, orgaanisen hiilen kokonaispitoisuus-, sokeri-, sameus- ja ligniinireduktioilla. Lisäksi määritettiin kalvon likaantuminen suodatuksen aikana vesivuon määrityksillä ennen ja jälkeen suodatuksen. Pesutehokkuus määritettiin vesivuon määrityksillä suodatuksen jälkeen ja pesun jälkeen. Kitosaani- ja karboksimetyyliselluloosakäsittelyillä oli vuon alenemista estävä vaikutus hydrofiilisellä nanosuodatuskalvolla suodatettaessa. Kitosaanikäsittelyn 5 g/dm3:n ja karboksimetyyliselluloosakäsittelyn 2 g/ dm3:n annostuksella vuot alentuivat suodatuksen aikana 8 %-yksikköä vähemmän kuin ilman esikäsittelyä. Puukuitukäsittely stabiloi 0,1 g/dm3:n annostuksella saman kalvon vuota, kun kiintoainetta ei poistettu syötöstä. Hydrofobisen nanosuodatuskalvon vuon alenemista ehkäisivät puu- ja selluloosakuitukäsittelyt sekä karboksimetyyliselluloosakäsittely. Karboksimetyyliselluloosakäsittely vähensi vuon alenemista 25 %-yksikköä ja puukuitukäsittely 13 %-yksikköä. Hydrofiilisellä ultrasuodatuskalvolla vuon aleneminen oli pientä ilman esikäsittelyä. Reduktioihin esikäsittelyt vaikuttivat parhaiten ultrasuodatuskalvolla. Kitosaanikäsittely nosti 1 g/dm3:n annostuksella alumiinireduktion 50 %:sta 96 %:iin ja 5 g/dm3:n annostuksella rautareduktion 30 %:sta 55 %:iin. Karboksyylimetyyliselluloosakäsittelyt vaikuttivat parantavasti mangaanin, magnesiumin, raudan ja kalsiumin reduktioihin. Optimi karboksyylimetyyliselluloosa-annostus oli 2 g/dm3. Merkittävin reduktion nousu oli kalsiumilla, jonka reduktio nousi esikäsittelyllä 4 %:sta 57 %:iin. Reduktiota nostava mekanismi oli kalvon pinnalle muodostuva sekundaarikerros. Pesuaineista tehokkain oli entsyymiä sisältävä kalvonpesuaine. Suurin vaikutus sillä oli hydrofobisen nanosuodatuskalvon pesussa. Optimiannostuksella (0,5 %) kalvon vesivuo pesun jälkeen oli 114 % pesua edeltäneestä vesivuosta. Muut kaupalliset pesuaneet oli tehokkaita hydrofiilisille kalvoille. Peretikkahappo oli yksittäisenä pesuaineena heikkotehoinen.
Resumo:
Bioactive glasses are excellent candidates for implant materials, because they can form a chemical bond to bone or guide bone growth, depending on the glass composition. Some compositions have even shown soft tissue attachment and antimicrobial effects. So far, most clinical applications are based on monoliths, plates and particulates of different grain sizes. There is a growing interest in special products such as porous implants sintered from microspheres and fibers drawn from preforms or glass melts. The viscosity range at which these are formed coincides with the crystallization temperature range for most bioactive glasses, thus complicating the manufacturing process. In this work, the crystallization tendency and its kinetics for a series of glasses with their compositions within the range of bioactivity were investigated. The factors affecting crystallization and how it is related to composition were studied by means of thermal analysis and hot stage microscopy. The crystal compositions formed during isothermal and non-isothermal heat treatments were analyzed with SEM-EDXA and X-ray diffraction analysis. The temperatures at which sintering and fiber drawing can take place without interfering with crystallization were determined and glass compositions which are suitable for these purposes were established. The bioactivity of glass fibers and partly crystallized glass plates was studied by soaking them in simulated body fluid (SBF). The thickness of silica, calcium and phosphate rich reaction layers on the glass surface after soaking was used as an indication of the bioactivity. The results indicated that the crystallization tendencies of the experimental glasses are strongly dependent on composition. The main factor affecting the crystallization was found to be the alkali oxide content: the higher the alkali oxide content the lower the crystallization temperature. The primary crystalline phase formed at low temperatures in these glasses was sodium calcium silicate. The crystals were found to form through internal nucleation, leading to bulk crystallization. These glasses had high bioactivity in vitro. Even when partially crystalline, they formed typical reaction layers, indicating bioactivity. In fact, sodium calcium silicate crystals were shown to transform in vitro into hydroxyapatite during soaking. However, crystallization should be avoided because it was shown to retard dissolution, bioactivity reactions and complicate fiber drawing process. Glass compositions having low alkali oxide content showed formation of wollastonite crystals on the surface, at about 300°C above the glass transition temperature. The wide range between glass transition and crystallization allowed viscous flow sintering of these compositions. These glasses also withstood the thermal treatments required for fiber drawing processing. Precipitation of calcium and phosphate on fibers of these glasses in SBF suggested that they were osteoconductive. Glasses showing bioactivity crystallize easily, making their hot working challenging. Undesired crystallization can be avoided by choosing suitable compositions and heat treatment parameters, allowing desired product forms to be attained. Small changes in the oxide composition of the glass can have large effects and therefore a thorough understanding of glass crystallization behavior is a necessity for a successful outcome, when designing and manufacturing implants containing bioactive glasses.
Resumo:
Tässä kandidaatintyössä tutkittiin, voidaanko puuhydrolysaatin esikäsittelyllä vähentää sen ultrasuodatuksen aikana esiintyvää kalvojen foulaantumista. Kokeellinen osa rajattiin koskemaan hydrolysaatin käsittelyä lakkaasientsyymillä, flokkulanteilla, kitosaanilla sekä adsorbentin ja lakkaasientsyymin yhdistelmällä. Esikäsittelyjen tavoitteena oli poistaa tai hajottaa hydrolysaatin sisältämää ligniiniä. Käsittelyjen teho testattiin suodattamalla eri tavoin käsiteltyä hydrolysaattia laboratoriokokeissa. Kokeissa adsorbentin ja lakkaasientsyymin yhdistelmäkäsittely osoittautui parhaaksi. Suodatuskapasiteetti parani ja foulaantuminen väheni verrattuna esikäsittelemättömän hydrolysaatin suodatukseen. Ligniiniä poistui käsittelyssä, kuten tavoitteena oli. Suodatuksessa kuitenkin edelleen tapahtui foulaantumista ja esikäsittelyn tehoa tulisi siksi vielä parantaa. Myös esikäsittely lakkaasientsyymillä paransi suodatuskapasiteettia ja vähensi foulaantumista, mutta vähemmän kuin entsyymi-adsorbenttikäsittely.
Resumo:
Cranial bone reconstructions are necessary for correcting large skull bone defects due to trauma, tumors, infections and craniotomies. Traditional synthetic implant materials include solid or mesh titanium, various plastics and ceramics. Recently, biostable glass-fiber reinforced composites (FRC), which are based on bifunctional methacrylate resin, were introduced as novel implant solution. FRCs were originally developed and clinically used in dental applications. As a result of further in vitro and in vivo testing, these composites were also approved for clinical use in cranial surgery. To date, reconstructions of large bone defects were performed in 35 patients. This thesis is dedicated to the development of a novel FRC-based implant for cranial reconstructions. The proposed multi-component implant consists of three main parts: (i) porous FRC structure; (ii) bioactive glass granules embedded between FRC layers and (iii) a silver-polysaccharide nanocomposite coating. The porosity of the FRC structure should allow bone ingrowth. Bioactive glass as an osteopromotive material is expected to stimulate the formation of new bone. The polysaccharide coating is expected to prevent bacterial colonization of the implant. The FRC implants developed in this study are based on the porous network of randomly-oriented E-glass fibers bound together by non-resorbable photopolymerizable methacrylate resin. These structures had a total porosity of 10–70 volume %, of which > 70% were open pores. The pore sizes > 100 μm were in the biologically-relevant range (50-400 μm), which is essential for vascularization and bone ingrowth. Bone ingrowth into these structures was simulated by imbedding of porous FRC specimens in gypsum. Results of push-out tests indicated the increase in the shear strength and fracture toughness of the interface with the increase in the total porosity of FRC specimens. The osteopromotive effect of bioactive glass is based on its dissolution in the physiological environment. Here, calcium and phosphate ions, released from the glass, precipitated on the glass surface and its proximity (the FRC) and formed bone-like apatite. The biomineralization of the FRC structure, due to the bioactive glass reactions, was studied in Simulated Body Fluid (SBF) in static and dynamic conditions. An antimicrobial, non-cytotoxic polysaccharide coating, containing silver nanoparticles, was obtained through strong electrostatic interactions with the surface of FRC. In in vitro conditions the lactose-modified chitosan (chitlac) coating showed no signs of degradation within seven days of exposure to lysozyme or one day to hydrogen peroxide (H2O2). The antimicrobial efficacy of the coating was tested against Staphylococcus aureus and Pseudomonas aeruginosa. The contact-active coating had an excellent short time antimicrobial effect. The coating neither affected the initial adhesion of microorganisms to the implant surface nor the biofilm formation after 24 h and 72 h of incubation. Silver ions released to the aqueous environment led to a reduction of bacterial growth in the culture medium.
Resumo:
Non-metallic implants made of bioresorbable or biostable synthetic polymers are attractive options in many surgical procedures, ranging from bioresorbable suture anchors of arthroscopic surgery to reconstructive skull implants made of biostable fiber-reinforced composites. Among other benefits, non-metallic implants produce less interference in imaging. Bioresorbable polymer implants may be true multifunctional, serving as osteoconductive scaffolds and as matrices for simultaneous delivery of bone enhancement agents. As a major advantage for loading conditions, mechanical properties of biostable fiber-reinforced composites can be matched with those of the bone. Unsolved problems of these biomaterials are related to the risk of staphylococcal biofilm infections and to the low osteoconductivity of contemporary bioresorbable composite implants. This thesis was focused on the research and development of a multifunctional implant model with enhanced osteoconductivity and low susceptibility to infection. In addition, the experimental models for assessment, diagnostics and prophylaxis of biomaterial-related infections were established. The first experiment (Study I) established an in vitro method for simultaneous evaluation of calcium phosphate and biofilm formation on bisphenol-Aglycidyldimethacrylate and triethylenglycoldimethacrylate (BisGMA-TEGDMA) thermosets with different content of bioactive glass 45S5. The second experiment (Study II) showed no significant difference in osteointegration of nanostructured and microsized polylactide-co-glycolide/β-tricalcium phosphate (PLGA /β-TCP) composites in a minipig model. The third experiment (Study III) demonstrated that positron emission tomography (PET) imaging with the novel 68Ga labelled 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid (DOTA) CD33 related sialic-acid immunoglobulin like lectins (Siglec-9) tracer was able to detect inflammatory response to S. epidermidis and S. aureus peri-implant infections in an intraosseous polytetrafluoroethylene catheter model. In the fourth experiment (Study IV), BisGMATEGDMA thermosets coated with lactose-modified chitosan (Chitlac) and silver nanoparticles exhibited antibacterial activity against S. aureus and P. aeruginosa strains in an in vitro biofilm model and showed in vivo biocompatibility in a minipig model. In the last experiment (Study V), a selective androgen modulator (SARM) released from a poly(lactide)-co-ε-caprolactone (PLCL) polymer matrix failed to produce a dose-dependent enhancement of peri-implant osteogenesis in a bone marrow ablation model.
Resumo:
Tämän työn tavoitteena oli selvittää, kuinka selluloosan lisääminen vaikuttaa polysulfonirunkoisiin membraaneihin. Lisäksi työssä selvitettiin selluloosamembraanien modifiointia kitosaanilla ja bentoniitilla. Työssä muodostettiin membraanit faasi-inversiotekniikalla. Selluloosamembraanien valmistuksessa jauhettu selluloosa liuotettiin ioniseen nesteeseen. Sekä polysulfonista että selluloosasta valmistetuille membraaneille määritettiin puhdasvesivuot ja retentiot. Retention määrittämiseen käytettiin malliaineena dekstraanin vesiliuosta. Lisäksi määriteltiin polysulfonipohjaisten membraanien hydrofiilisyys tutkimalla membraanien pintojen ja vesipisaroiden välisiä kontaktikulmia. Polysulfonimembraaneihin lisätyn selluloosan havaittiin pienentävän puhdasvesivuota ja kasvattavan hydrofiilisyyttä mitä enemmän selluloosaa oli membraanimatriisissa. Kaikkien selluloosalla modifioitujen membraanien retentiot olivat suurempia kuin modifioimattoman polysulfonimembraanin. Kitosaanilla modifioitujen selluloosamembraanien valmistus ei onnistunut johtuen luultavasti kitosaanin liian suuresta partikkelikoosta. Bentoniitilla modifioitujen membraanien vuot olivat merkittävästi suuremmat sekä niiden retentiot pienemmät verrattuna modifioimattomaan selluloosamembraaniin. Tämä johtui luultavasti siitä, että bentoniitin lisääminen aiheutti membraanirakenteeseen reikiä.