8 resultados para Vertical Crack

em Doria (National Library of Finland DSpace Services) - National Library of Finland, Finland


Relevância:

20.00% 20.00%

Publicador:

Resumo:

To predict the capacity of the structure or the point which is followed by instability, calculation of the critical crack size is important. Structures usually contain several cracks but not necessarily all of these cracks lead to failure or reach the critical size. So, defining the harmful cracks or the crack size which is the most leading one to failure provides criteria for structure’s capacity at elevated temperature. The scope of this thesis was to calculate fracture parameters like stress intensity factor, the J integral and plastic and ultimate capacity of the structure to estimate critical crack size for this specific structure. Several three dimensional (3D) simulations using finite element method by Ansys program and boundary element method by Frank 3D program were carried out to calculate fracture parameters and results with the aid of laboratory tests (loaddisplacement curve, the J resistance curve and yield or ultimate stress) leaded to extract critical size of the crack. Two types of the fracture which is usually affected by temperature, Elastic and Elasti-Plastic fractures were simulated by performing several linear elastic and nonlinear elastic analyses. Geometry details of the weldment; flank angle and toe radius were also studied independently to estimate the location of crack initiation and simulate stress field in early stages of crack extension in structure. In this work also overview of the structure’s capacity in room temperature (20 ºC) was studied. Comparison of the results in different temperature (20 ºC and -40 ºC) provides a threshold of the structure’s behavior within the defined range.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The behavior of the nuclear power plants must be known in all operational situations. Thermal hydraulics computer applications are used to simulate the behavior of the plants. The computer applications must be validated before they can be used reliably. The simulation results are compared against the experimental results. In this thesis a model of the PWR PACTEL steam generator was prepared with the TRAC/RELAP Advanced Computational Engine computer application. The simulation results can be compared against the results of the Advanced Process Simulator analysis software in future. Development of the model of the PWR PACTEL vertical steam generator is introduced in this thesis. Loss of feedwater transient simulation examples were carried out with the model.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tämä työ käsittelee valkaistun ja valkaisemattoman sellumassan varastosäiliön tärinää ja värähtelyä. Värähtelyn seurauksena säiliön seinämän jäykisterenkaan hitsausliitokseen on syntynyt särö. Työn tavoitteena on selvittää, mikä johtaa särön syntyyn ja miten kestäväm-piä varastosäiliöitä voidaan rakentaa materiaali-, valmistus- tai rakennemuutoksien avulla. Työ alkoi tutkimalla rakennemateriaalina olevan duplex-teräksen mikrorakenteen ominai-suuksia, sekä sen hitsattavuutta ja seostamista kirjallisuustutkimuksena. Kirjallisuustutki-musta jatkettiin selvittämällä mahdollisia vaurion syntymekanismeja seinämän särölle. Työssä analysoitiin myös tehtaalla mitattuja värähtelyarvoja. Lopuksi laskettiin FE-analyysillä tyhjän varastosäiliön ominaismuodot ja -taajuudet moodianalyysillä, sekä selvi-tettiin harmonisella analyysillä pinnankorkeuden vaihtelun vaikutus siirtymävasteeseen ja kriittisiin värähtelytaajuuksiin. Varastosäiliöön kohdistuvaa värähtelyä ei ole mahdollista poistaa kokonaan, mutta väräh-telyn aiheuttamia seurauksia kyetään rajaamaan useilla keinoilla. Toimenpiteinä voivat olla ainakin seinämän materiaalin paksuuden lisääminen, jäykisteripojen lisääminen ja kriittisten sellun pinnankorkeuksien välttäminen. Kriittiseksi pinnankorkeudeksi havaittiin 40–45 %:n täyttöaste ja turvalliseksi korkeudeksi 35–38 %:n täyttöaste. Varastosäiliölle kriittisen ominaistaajuuden katsotaan syntyvän taajuuksilla 3,3–3,8 Hz ja 5,8–6,4 Hz. Sellumassa putoaa varastosäiliöön noin 2 Hz taajuudella.