60 resultados para Three-phase power flow
em Doria (National Library of Finland DSpace Services) - National Library of Finland, Finland
Resumo:
The maximum realizable power throughput of power electronic converters may be limited or constrained by technical or economical considerations. One solution to this problemis to connect several power converter units in parallel. The parallel connection can be used to increase the current carrying capacity of the overall system beyond the ratings of individual power converter units. Thus, it is possible to use several lower-power converter units, produced in large quantities, as building blocks to construct high-power converters in a modular manner. High-power converters realized by using parallel connection are needed for example in multimegawatt wind power generation systems. Parallel connection of power converter units is also required in emerging applications such as photovoltaic and fuel cell power conversion. The parallel operation of power converter units is not, however, problem free. This is because parallel-operating units are subject to overcurrent stresses, which are caused by unequal load current sharing or currents that flow between the units. Commonly, the term ’circulatingcurrent’ is used to describe both the unequal load current sharing and the currents flowing between the units. Circulating currents, again, are caused by component tolerances and asynchronous operation of the parallel units. Parallel-operating units are also subject to stresses caused by unequal thermal stress distribution. Both of these problemscan, nevertheless, be handled with a proper circulating current control. To design an effective circulating current control system, we need information about circulating current dynamics. The dynamics of the circulating currents can be investigated by developing appropriate mathematical models. In this dissertation, circulating current models aredeveloped for two different types of parallel two-level three-phase inverter configurations. Themodels, which are developed for an arbitrary number of parallel units, provide a framework for analyzing circulating current generation mechanisms and developing circulating current control systems. In addition to developing circulating current models, modulation of parallel inverters is considered. It is illustrated that depending on the parallel inverter configuration and the modulation method applied, common-mode circulating currents may be excited as a consequence of the differential-mode circulating current control. To prevent the common-mode circulating currents that are caused by the modulation, a dual modulator method is introduced. The dual modulator basically consists of two independently operating modulators, the outputs of which eventually constitute the switching commands of the inverter. The two independently operating modulators are referred to as primary and secondary modulators. In its intended usage, the same voltage vector is fed to the primary modulators of each parallel unit, and the inputs of the secondary modulators are obtained from the circulating current controllers. To ensure that voltage commands obtained from the circulating current controllers are realizable, it must be guaranteed that the inverter is not driven into saturation by the primary modulator. The inverter saturation can be prevented by limiting the inputs of the primary and secondary modulators. Because of this, also a limitation algorithm is proposed. The operation of both the proposed dual modulator and the limitation algorithm is verified experimentally.
Resumo:
Airlift reactors are pneumatically agitated reactors that have been widely used in chemical, petrochemical, and bioprocess industries, such as fermentation and wastewater treatment. Computational Fluid Dynamics (CFD) has become more popular approach for design, scale-up and performance evaluation of such reactors. In the present work numerical simulations for internal-loop airlift reactors were performed using the transient Eulerian model with CFD package, ANSYS Fluent 12.1. The turbulence in the liquid phase is described using κ- ε the model. Global hydrodynamic parameters like gas holdup, gas velocity and liquid velocity have been investigated for a range of superficial gas velocities, both with 2D and 3D simulations. Moreover, the study of geometry and scale influence on the reactor have been considered. The results suggest that both, geometry and scale have significant effects on the hydrodynamic parameters, which may have substantial effects on the reactor performance. Grid refinement and time-step size effect have been discussed. Numerical calculations with gas-liquid-solid three-phase flow system have been carried out to investigate the effect of solid loading, solid particle size and solid density on the hydrodynamic characteristics of internal loop airlift reactor with different superficial gas velocities. It was observed that averaged gas holdup is significantly decreased with increasing slurry concentration. Simulations show that the riser gas holdup decreases with increase in solid particle diameter. In addition, it was found that the averaged solid holdup increases in the riser section with the increase of solid density. These produced results reveal that CFD have excellent potential to simulate two-phase and three-phase flow system.
Resumo:
Detta arbete fokuserar på modellering av katalytiska gas-vätskereaktioner som genomförs i kontinuerliga packade bäddar. Katalyserade gas-vätskereaktioner hör till de mest typiska reaktionerna i kemisk industri; därför behandlas här packade bäddreaktorer som ett av de populäraste alternativen, då kontinuerlig drift eftersträvas. Tack vare en stor katalysatormängd per volym har de en kompakt struktur, separering av katalysatorn behövs inte och genom en professionell design kan den mest fördelaktiga strömningsbilden upprätthållas i reaktorn. Packade bäddreaktorer är attraktiva p.g.a. lägre investerings- och driftskostnader. Även om packade bäddar används intensivt i industri, är det mycket utmanande att modellera. Detta beror på att tre faser samexisterar och systemets geometri är komplicerad. Existensen av flera reaktioner gör den matematiska modelleringen även mera krävande. Många förenklingar blir därmed nödvändiga. Modellerna involverar typiskt flera parametrar som skall justeras på basis av experimentella data. I detta arbete studerades fem olika reaktionssystem. Systemen hade studerats experimentellt i vårt laboratorium med målet att nå en hög produktivitet och selektivitet genom ett optimalt val av katalysatorer och driftsbetingelser. Hydrering av citral, dekarboxylering av fettsyror, direkt syntes av väteperoxid samt hydrering av sockermonomererna glukos och arabinos användes som exempelsystem. Även om dessa system hade mycket gemensamt, hade de också unika egenskaper och krävde därför en skräddarsydd matematisk behandling. Citralhydrering var ett system med en dominerande huvudreaktion som producerar citronellal och citronellol som huvudprodukter. Produkterna används som en citrondoftande komponent i parfymer, tvålar och tvättmedel samt som plattform-kemikalier. Dekarboxylering av stearinsyra var ett specialfall, för vilket en reaktionsväg för produktion av långkedjade kolväten utgående från fettsyror söktes. En synnerligen hög produktselektivitet var karakteristisk för detta system. Även processuppskalning modellerades för dekarboxylerings-reaktionen. Direkt syntes av väteperoxid hade som målsättning att framta en förenklad process att producera väteperoxid genom att låta upplöst väte och syre reagera direkt i ett lämpligt lösningsmedel på en aktiv fast katalysator. I detta system förekommer tre bireaktioner, vilka ger vatten som oönskad produkt. Alla dessa tre reaktioner modellerades matematiskt med hjälp av dynamiska massbalanser. Målet med hydrering av glukos och arabinos är att framställa produkter med en hög förädlingsgrad, nämligen sockeralkoholer, genom katalytisk hydrering. För dessa två system löstes ämnesmängd- och energibalanserna simultant för att evaluera effekter inne i porösa katalysatorpartiklar. Impulsbalanser som bestämmer strömningsbetingelser inne i en kemisk reaktor, ersattes i alla modelleringsstudier med semi-empiriska korrelationsuttryck för vätskans volymandel och tryckförlust och med axiell dispersionsmodell för beskrivning av omblandningseffekter. Genom att justera modellens parametrar kunde reaktorns beteende beskrivas väl. Alla experiment var genomförda i laboratorieskala. En stor mängd av kopplade effekter samexisterade: reaktionskinetik inklusive adsorption, katalysatordeaktivering, mass- och värmeöverföring samt strömningsrelaterade effekter. En del av dessa effekter kunde studeras separat (t.ex. dispersionseffekter och bireaktioner). Inverkan av vissa fenomen kunde ibland minimeras genom en noggrann planering av experimenten. På detta sätt kunde förenklingar i modellerna bättre motiveras. Alla system som studerades var industriellt relevanta. Utveckling av nya, förenklade produktionsteknologier för existerande kemiska komponenter eller nya komponenter är ett gigantiskt uppdrag. Studierna som presenterades här fokuserade på en av den teknisk-vetenskapliga utfärdens första etapper.
Resumo:
Permanent magnet synchronous machines (PMSM) have become widely used in applications because of high efficiency compared to synchronous machines with exciting winding or to induction motors. This feature of PMSM is achieved through the using the permanent magnets (PM) as the main excitation source. The magnetic properties of the PM have significant influence on all the PMSM characteristics. Recent observations of the PM material properties when used in rotating machines revealed that in all PMSMs the magnets do not necessarily operate in the second quadrant of the demagnetization curve which makes the magnets prone to hysteresis losses. Moreover, still no good analytical approach has not been derived for the magnetic flux density distribution along the PM during the different short circuits faults. The main task of this thesis is to derive simple analytical tool which can predict magnetic flux density distribution along the rotor-surface mounted PM in two cases: during normal operating mode and in the worst moment of time from the PM’s point of view of the three phase symmetrical short circuit. The surface mounted PMSMs were selected because of their prevalence and relatively simple construction. The proposed model is based on the combination of two theories: the theory of the magnetic circuit and space vector theory. The comparison of the results in case of the normal operating mode obtained from finite element software with the results calculated with the proposed model shows good accuracy of model in the parts of the PM which are most of all prone to hysteresis losses. The comparison of the results for three phase symmetrical short circuit revealed significant inaccuracy of the proposed model compared with results from finite element software. The analysis of the inaccuracy reasons was provided. The impact on the model of the Carter factor theory and assumption that air have permeability of the PM were analyzed. The propositions for the further model development are presented.
Resumo:
Line converters have become an attractive AC/DC power conversion solution in industrial applications. Line converters are based on controllable semiconductor switches, typically insulated gate bipolar transistors. Compared to the traditional diode bridge-based power converters line converters have many advantageous characteristics, including bidirectional power flow, controllable de-link voltage and power factor and sinusoidal line current. This thesis considers the control of the lineconverter and its application to power quality improving. The line converter control system studied is based on the virtual flux linkage orientation and the direct torque control (DTC) principle. A new DTC-based current control scheme is introduced and analyzed. The overmodulation characteristics of the DTC converter are considered and an analytical equation for the maximum modulation index is derived. The integration of the active filtering features to the line converter isconsidered. Three different active filtering methods are implemented. A frequency-domain method, which is based on selective harmonic sequence elimination, anda time-domain method, which is effective in a wider frequency band, are used inharmonic current compensation. Also, a voltage feedback active filtering method, which mitigates harmonic sequences of the grid voltage, is implemented. The frequency-domain and the voltage feedback active filtering control systems are analyzed and controllers are designed. The designs are verified with practical measurements. The performance and the characteristics of the implemented active filtering methods are compared and the effect of the L- and the LCL-type line filteris discussed. The importance of the correct grid impedance estimate in the voltage feedback active filter control system is discussed and a new measurement-based method to obtain it is proposed. Also, a power conditioning system (PCS) application of the line converter is considered. A new method for correcting the voltage unbalance of the PCS-fed island network is proposed and experimentally validated.
Resumo:
In this master's thesis a mechanical model that is driven with variable speed synchronous machine was developed. The developed mechanical model simulates the mechanics of power transmission and its torsional vibrations. The mechanical model was developed for the need of the branched mechanics of a rolling mill and the propulsion system of a tanker. First, the scope of the thesis was to clarify the concepts connected to the mechanical model. The clarified concepts are the variable speed drive, the mechanics of power transmission and the vibrationsin the power transmission. Next, the mechanical model with straight shaft line and twelve moments of inertia that existed in the beginning was developed to be branched considering the case of parallel machines and the case of parallel rolls. Additionally, the model was expanded for the need of moreaccurate simulation to up to thirty moments of inertia. The model was also enhanced to enable three phase short circuit situation of the simulated machine. After that the mechanical model was validated by comparing the results of the developed simulation tool to results of other simulation tools. The compared results are the natural frequencies and mode shapes of torsional vibration, the response of the load torque step and the stress in the mechanical system occurred by the permutation of the magnetic field that is arisen from the three phase short circuit situation. The comparisons were accomplished well and the mechanical model was validated for the compared cases. Further development to be made is to develop the load torque to be time-dependent and to install two frequency converters and two FEM modeled machines to be simulated parallel.
Resumo:
Data transmission between an electric motor and a frequency converter is required in variablespeed electric drives because of sensors installed at the motor. Sensor information can be used for various useful applications to improve the system reliability and its properties. Traditionally, the communication medium is implemented by an additional cabling. However, the costs of the traditional method may be an obstacle to the wider application of data transmission between a motor and a frequency converter. In any case, a power cable is always installed between a motor and a frequency converter for power supply, and hence it may be applied as a communication medium for sensor level data. This thesis considers power line communication (PLC) in inverter-fed motor power cables. The motor cable is studied as a communication channel in the frequency band of 100 kHz−30 MHz. The communication channel and noise characteristics are described. All the individual components included in a variable-speed electric drive are presented in detail. A channel model is developed, and it is verified by measurements. A theoretical channel information capacity analysis is carried out to estimate the opportunities of a communication medium. Suitable communication and forward error correction (FEC) methods are suggested. A general method to implement a broadband and Ethernet-based communication medium between a motor and a frequency converter is proposed. A coupling interface is also developed that allows to install the communication device safely to a three-phase inverter-fed motor power cable. Practical tests are carried out, and the results are analyzed. Possible applications for the proposed method are presented. A speed feedback motor control application is verified in detail by simulations and laboratory tests because of restrictions for the delay in the feedback loop caused by PLC. Other possible applications are discussed at a more general level.
Resumo:
The increasing power demand and emerging applications drive the design of electrical power converters into modularization. Despite the wide use of modularized power stage structures, the control schemes that are used are often traditional, in other words, centralized. The flexibility and re-usability of these controllers are typically poor. With a dedicated distributed control scheme, the flexibility and re-usability of the system parts, building blocks, can be increased. Only a few distributed control schemes have been introduced for this purpose, but their breakthrough has not yet taken place. A demand for the further development offlexible control schemes for building-block-based applications clearly exists. The control topology, communication, synchronization, and functionality allocationaspects of building-block-based converters are studied in this doctoral thesis. A distributed control scheme that can be easily adapted to building-block-based power converter designs is developed. The example applications are a parallel and series connection of building blocks. The building block that is used in the implementations of both the applications is a commercial off-the-shelf two-level three-phase frequency converter with a custom-designed controller card. The major challenge with the parallel connection of power stages is the synchronization of the building blocks. The effect of synchronization accuracy on the system performance is studied. The functionality allocation and control scheme design are challenging in the seriesconnected multilevel converters, mainly because of the large number of modules. Various multilevel modulation schemes are analyzed with respect to the implementation, and this information is used to develop a flexible control scheme for modular multilevel inverters.
Resumo:
Sähkömoottorin jatkuva-aikainen kunnonvalvonta vaatii tiedonsiirtoa moottorilta ylemmälle tietojärjestelmätasolle, kuten taajuusmuuttajalle. Uusien kaapeleiden asennus on työlästä ja kallista. Moottorin ja taajuusmuuttajan välillä on kuitenkin aina kaapeli, jota käytetään moottorin tehonsyöttöön. Tätä kaapelia on mahdollista käyttää myös tiedonsiirtokanavana. Tässä diplomityössä käsitellään ja tutkitaan sähköverkkotiedonsiirtomenetelmää, jonka avulla voidaan muodostaa Ethernet-yhteys moottorilta taajuusmuuttajalle tai toisinpäin. Työssä kehitetään simulointimalli tiedonsiirtokanavan taajuusriippuvan vaimennuksen simuloimiseen. Lisäksi kehitetään kytkentärajapinta, joka mahdollistaa tiedonsiirron kolmivaiheisessa taajuusmuuttajan syöttämässä moottorikaapelissa. Työssä suunnitellaan ja toteutetaan tiedonsiirtoa varten pilot-laitteisto, jolla tehdään laboratoriotestit. Laboratoriotesteillä varmistetaan menetelmän soveltuvuus. Laboratoriotestien avulla etsitään myös reunaehdot tiedonsiirron toiminnalle ja tiedonsiirtonopeuteen vaikuttavia tekijöitä taajuusmuuttajakäytössä. Lisäksi tarkastellaan menetelmän aiheuttamaa viivettä, joka on tärkeäsäätösovellusten kannalta. Lopuksi arvioidaan menetelmän soveltuvuus käytännön sovelluksiin.
Resumo:
IIn electric drives, frequency converters are used to generatefor the electric motor the AC voltage with variable frequency and amplitude. When considering the annual sale of drives in values of money and units sold, the use of low-performance drives appears to be in predominant. These drives have tobe very cost effective to manufacture and use, while they are also expected to fulfill the harmonic distortion standards. One of the objectives has also been to extend the lifetime of the frequency converter. In a traditional frequency converter, a relatively large electrolytic DC-link capacitor is used. Electrolytic capacitors are large, heavy and rather expensive components. In many cases, the lifetime of the electrolytic capacitor is the main factor limiting the lifetime of the frequency converter. To overcome the problem, the electrolytic capacitor is replaced with a metallized polypropylene film capacitor (MPPF). The MPPF has improved properties when compared to the electrolytic capacitor. By replacing the electrolytic capacitor with a film capacitor the energy storage of the DC-linkwill be decreased. Thus, the instantaneous power supplied to the motor correlates with the instantaneous power taken from the network. This yields a continuousDC-link current fed by the diode rectifier bridge. As a consequence, the line current harmonics clearly decrease. Because of the decreased energy storage, the DC-link voltage fluctuates. This sets additional conditions to the controllers of the frequency converter to compensate the fluctuation from the supplied motor phase voltages. In this work three-phase and single-phase frequency converters with small DC-link capacitor are analyzed. The evaluation is obtained with simulations and laboratory measurements.
Resumo:
Design aspects of the Transversally Laminated Anisotropic (TLA) Synchronous Reluctance Motor (SynRM) are studied and the machine performance analysis compared to the Induction Motor (IM) is done. The SynRM rotor structure is designed and manufactured for a30 kW, four-pole, three-phase squirrel cage induction motor stator. Both the IMand SynRM were supplied by a sensorless Direct Torque Controlled (DTC) variablespeed drive. Attention is also paid to the estimation of the power range where the SynRM may compete successfully with a same size induction motor. A technicalloss reduction comparison between the IM and SynRM in variable speed drives is done. The Finite Element Method (FEM) is used to analyse the number, location and width of flux barriers used in a multiple segment rotor. It is sought for a high saliency ratio and a high torque of the motor. It is given a comparison between different FEM calculations to analyse SynRM performance. The possibility to take into account the effect of iron losses with FEM is studied. Comparison between the calculated and measured values shows that the design methods are reliable. A new application of the IEEE 112 measurement method is developed and used especially for determination of stray load losses in laboratory measurements. The study shows that, with some special measures, the efficiency of the TLA SynRM is equivalent to that of a high efficiency IM. The power factor of the SynRM at rated load is smaller than that of the IM. However, at lower partial load this difference decreases and this, probably, brings that the SynRM gets a better power factor in comparison with the IM. The big rotor inductance ratio of the SynRM allows a good estimating of the rotor position. This appears to be very advantageous for the designing of the rotor position sensor-less motor drive. In using the FEM designed multi-layer transversally laminated rotor with damper windings it is possible to design a directly network driven motor without degrading the motorefficiency or power factor compared to the performance of the IM.
Resumo:
Pienjännitejakeluverkko Suomessa on toteutettu 400 V:n kolmivaiheisella vaihtosähköllä. Pienestä jännitteestä johtuen 20/0.4 kV:n muuntajat täytyy sijoittaa lähelle kuluttajaa, jotta siirtohäviöt eivät nouse liian suuriksi. Suuremman vaihto- tai tasajännitteen käyttö pienjännitejakelussa kasvattaisi verkon tehonsiirtokapasiteettia ja mahdollistaisi pidempien siirtomatkojen käytön. Käynnissä olevassa tutkimushankkeessa käsitellään vaihtoehtoa, jossa tasajännitettä käytettäisiin 20 kV:n verkon ja kuluttajan välisessä tehonsiirrossa ja kuluttajalla sijaitseva vaihtosuuntaaja muodostaisi tasasähköstä standardien mukaista yksi- tai kolmivaiheista vaihtosähköä. Tässä diplomityössä käsitellään tehoelektroniikan soveltamista kuluttajalle sijoitetussa vaihtosuuntaajassa. Työssä tarkastellaan yksivaiheisia invertteritopologioita, niiden ohjausta ja soveltamista erilaisissa vaihtosuuntaajaratkaisuissa sekä LC- ja LCL-suotimien soveltuvuutta invertterin lähtöjännitteen suodatukseen. Lisäksi esitellään erilaisia rakenneratkaisuja vaihtosuuntauksen toteutukseen ja tarkastellaan näiden järjestelmien vikatilanteita ja sähköturvallisuutta. Lopuksi käsitellään koko järjestelmän häviöitä ja hyötysuhdetta eri suodinkomponenteilla sekä kytkentätaajuuksilla ja esitellään laboratorioprototyyppi. Työssä saatiin selville, että puolisiltainvertteri ei sovellu suurten kondensaattorien vuoksi syöttämään verkkotaajuista kuormaa, vaan joudutaan käyttämään kokosiltainvertteriä. Kokosiltainvertterin ja LC- tai LCL-suotimen käsittävää kokonaisuutta tarkasteltaessa havaittiin, että pienimmät häviöt saavutetaan LC-suotimella 5 %:n ja LCL-suotimella 1 %:n särövaatimuksella. Hyötysuhdekäyrää tarkasteltaessa saatiin sama tulos läpi koko invertterin tehoalueen. Suotimen häviöiden tarkka laskenta on kuitenkin erittäin haasteellista, joten tulokset ovat suuntaa-antavia.
Resumo:
Pienitehoisessa taajuusmuuttajassa verkkojännite tasasuunnataan yleisesti diodisillalla. Taajuusmuuttajaa kuormitettaessa diodisilta aiheuttaa sen, että verkosta otettava virta on epäsinimuotoista ja sisältää runsaasti eri kertalukujen yliaaltoja. Tällainen virta vääristää verkon jännitettä sekä aiheuttaa häviöitä, resonansseja ja toimintaepävarmuutta sähkönjakeluverkkoon liitetyissä laitteissa ja komponenteissa. Työssä on tarkasteltu pienitehoisen kolmivaiheisen taajuusmuuttajan tulovirrassa esiintyviä yliaaltoja ja keinoja niiden rajoittamiseksi. Laitevalmistajien osalta syynä aiheen tutkimiseen ja kiinnostavuuteen ovat lähinnä uudet yliaaltoja käsittelevät standardit. Työssä onkin tutustuttu tarvittavin osin standardoinnin nykytilaan sekä seurattu standardeja valmistelevien työryhmien työtä ja tätä kautta perehdytty alaa käsittelevien standardien tulevaisuudennäkymiin Euroopan Unionin alueella. Käsittely on kohdistettu kolmivaiheisiin laitteisiin. Standardi IEC 61000-3-2 asettaa yliaaltorajat ammattikäyttöön tarkoitetuille laitteille, kun laitteen tuloteho on korkeintaan 1 kW. Tällä tehoalueella riittää kolmivaihelaitteille kuristimilla suoritettu passiivinen suodatus täyttämään asetetut viranomaisvaatimukset. Tähän liittyen on suunniteltu kolmivaihekuristin, joka on tarkoitettu käytettäväksi taajuusmuuttajasarjan lisävarusteena tehoalueella 0.12…2.2 kW.
Resumo:
Verkon harmonisvirtoja rajoittavien standardien tiukentuessa joudutaan etenkin suuritehoisissa tehoelektronisissa laitteissa siirtymään aktiivisiin transistoriohjattuihin tasasuuntaajiin, jotka korjaavat tehokerrointa ja siten pienentävät verkkoon kytkeytyviä häiriövirtoja. Tässä diplomityössä esitellään yleisimpien kolmivaiheisten tasasuuntaajatopologioiden eroja ja vertaillaan puoliohjatun kolmikytkintopologian ja kuusikytkintopologian suorituskykyä tehokertoimen ja harmonissärön osalta, 16 kilowatin teholuokan taajuusmuuttajassa. Tasasuuntaajille tehtiin skalaariohjaukseen perustuva simulointimalli. Työn tavoitteena esitellään simulointitulokset harmonistason sekä tehokertoimen osalta. Työ liittyy Lappeenrannan teknillisen yliopiston sovelletun elektroniikan laboratorion ja Vacon Oyj:n yhteiseen hankkeeseen.
Resumo:
In the Thesis main focus is done on power flow development paths around the Baltic States as well as on market-based requirements for creation of the common Baltic electricity market. Current market regulations between the countries are presented; barriers for creating competitive common Baltic power market and for electricity trading with third countries are clarified; solutions are offered and corresponding road map is developed. Future power development paths around the Baltic States are analysed. For this purpose the 330 kV transmission grid of Estonia, Latvia and Lithuania is modelled in a power flow tool. Power flow calculations are carried out for winter and summer peak and off-peak load periods in 2020 with different combinations of interconnections. While carrying out power balance experiments several power flow patterns in the Baltic States are revealed. Conclusions are made about security of supply, grid congestion and transmission capacity availability for different scenarios.