81 resultados para Thermal Recovery
em Doria (National Library of Finland DSpace Services) - National Library of Finland, Finland
Resumo:
This master’s thesis handles an operating model for an electric equipment supplier conducted sale oriented energy audit for pumping, fan and other motor applications at power plants. The study goes through the largest factors affecting internal electricity use at a power plant, finds an energy audit –like approach for the basis of information gathering and presents the information needed for conducting the analysis. The model is tested in practice at a kraft recovery boiler of a chemical pulping mill. Targets chosen represent some of the largest electric motor applications in the boiler itself and in its fuel handling. The energy saving potential of the chosen targets is calculated by simulating the energy consumption of the alternatives for controlling the targets, and thereafter combining the information with the volume flow duration curve. Results of the research are somewhat divaricated, as all the information needed is not available in the automation system. Some of the targets could be simulated and their energy saving potential calculated quite easily. At some of the targets chosen the monitoring was not sufficient enough for this and additional measurements would have been needed to base the calculations on. In traditional energy audits, energy efficiency of pump and fan applications is not necessarily examined. This means that there are good possibilities for developing the now presented targeted energy audit procedure basis further.
Resumo:
Carboxylic acids are commonly used organic acids and have many applications in industries producing food and pharmaceutical products, surfactants and detergents. Especially formic, acetic, propionic and butyric acid are important organic chemicals. These compounds can be found in many side streams and plant effluents. Recovery costs of carboxylic acids are high when they are removed from dilute solution. Conventional processes for the recovery of carboxylic acids from aqueous solutions are classical distillation or extractive distillation, azeotropic distillation or liquid-liquid extraction. The literature part of this Master’s of Science Thesis comprises possible extractants in liquid-liquid extraction of carboxylic acids from aqueous solutions and methods for their regeneration form the extract. The experimental part of this Thesis investigates liquid-liquid extraction of carboxylic acids from aqueous solutions. The aim of this work was to find a suitable extractant for liquid-liquid extraction and suitable process conditions to recover carboxylic acids from aqueous solutions. Also, back extraction of carboxylic acids and their thermal decomposition in relation to distillation of were. Experiments showed that there is more than one possible extractant for liquid-liquid extraction of carboxylic acids. Results also showed that it is possible to separate carboxylic acids and regenerate all the used extractants by vacuum distillation at suitable temperature.
Resumo:
Tässä työssä perehdytään soodakattiloiden vesikiertomallin rakentamiseen. Työn päätavoitteena on kehittää simulointimallia varten taulukkolaskentapohja, jonka avulla soodakattilan lämpövuotietoja on yksinkertaista ja nopeaa käsitellä ja siirtää Apros 6 -simulointiohjelmaan. Lisäksi tarkoituksena on pyrkiä automatisoimaan työvaiheet mahdollisimman pitkälle, jolloin vesikiertolaskennan tekeminen yksinkertaistuisi, yhtenäistyisi ja tarkentuisi. Tämä on mahdollista Excel- makrojen ja Apros 6:n uusien toimintojen avulla. Apros 6:ssa on nyt mahdollista hyödyntää SCL- komentotiedostoja, joiden avulla sujuva tiedonsiirto Aproksen ja Excelin välillä vodaan toteuttaa. Vesikiertolaskentaan käytettävän datan käsittely on aikaisemmin ollut työlästä ja sen tarkkuus on pitkälti riippunut mallintajasta. Tässä diplomityössä päästään hyödyntämään uusimpia ja realistisempia soodakattiloiden CFD- malleja, joiden avulla pystytään luomaan aikaisempaa tarkemmat lämpövuojakaumat soodakattilan lämpöpinnoille. Tämä muutos parantaa vesikiertolaskennan tarkkuutta. Työn kokeellisessa osassa uutta Excel laskentatyökalua ja uusia lämpövuoarvoja testataan käytännössä. Eräs vanha Apros- vesikiertomalli päivitetään uusilla lämpövuoarvoilla ja sen rakenteeseen tehdään muutoksia tarkkuuden parantamiseksi. Uuden mallin toimivuutta testataan myös 115 %:n kapasiteetilla ja tutkitaan kuinka kyseinen vesikiertopiiri reagoi suurempaan lämpötehoon. Näitä kolmea eri tilannetta vertaillaan toisiinsa ja tarkastellaan eroavaisuuksia niiden vesi-höyrypiireissä.
Resumo:
Selostus: Termisen kasvukauden muutokset Pohjoismaissa viimeisen vuosisadan aikana ja tulevaisuudessa
Resumo:
Potilaiden käsitys terveyteen liittyvästä elämänlaadusta lonkan tekonivelleikkauksen jälkeisenä toipumisaikana – kuuden kuukauden seurantatutkimus Tässä kaksivaiheisessa seurantatutkimuksessa tarkasteltiin potilaiden käsitystä terveyteen liittyvästä elämänlaadusta lonkan tekonivelleikkauksen jälkeisenä toipumisaikana. Tutkimuksen ensimmäisessä vaiheessa tarkoituksena oli sekä kuvailla potilaiden kokemuksia potilaana olosta, saamastaan hoidosta ja terveyspalveluorganisaatiosta että analysoida aikaisempien tutkimusten perusteella leikkauksen tuloksia potilaan kannalta. Toisessa vaiheessa tarkoituksena oli arvioida potilaiden kokemaa elämänlaatua leikkauksen jälkeen, ja sitä vaikuttivatko primaaritulokset (fyysinen toimintakyky, kipu, ahdistus) tai taloudelliset seuraukset (potilaiden itsensämaksamat kustannukset, palvelujen käyttö) terveyteen liittyvään elämänlaatuun. Tutkimuksen tavoitteena oli löytää mahdolliset kriittiset ajankohdat tai tekijät, jotka saattavat hidastaa toipumista ja siten huonontaa potilaiden elämänlaatua. Tätä tietoa voidaan käyttää hoitotyössä kun suunnitellaan sopivaa hoitoa ja tukea toipumisajalle. Tutkimuksen ensimmäisessä vaiheessa primaarileikkaukseen tulevat potilaat (n = 17) kuvailivat teemahaastatteluissa kokemuksiaan kahdesti leikkauksen jälkeen. Haastatteluaineisto analysoitiin induktiivisella sisällönanalyysilla. Lisäksi 17 tutkimusartikkelista analysoitiin deduktiivisella sisällönanalyysilla leikkauksen tuloksia potilaalle, tuloksiin vaikuttavia tekijöitä ja käytetyt tutkimusmetodit. Toisessa vaiheessa primaari- tai revisioleikkaukseen tulevat potilaat (n = 100) arvioivat leikkauksen tuloksia kuuden kuukauden ajan leikkauksen jälkeen: terveyteen liittyvää elämänlaatua, primaarituloksia ja taloudellisia seurauksia. Aineisto kerättiin erilaisilla mittareilla: Sickness Impact Profile, Finnish Version, Stait-Trait Anxiety Inventory, ja Numeric Rating Scale. Lisäksi käytettiin tätä tutkimusta varten tehtyjä kyselylomakkeita: Fyysinen toimintakyky-mittari, Palvelujen käyttö-mittari ja Kustannusmittari. Tutkimuksen toiseen vaiheen tulokset analysoitiin tilastollisilla menetelmillä. Potilaiden terveyteen liittyvä elämänlaatu parani ja kipu lievittyi leikkauksen jälkeen ja fyysinen toimintakyky lisääntyi toipumisaikana. Positiivisista muutoksista huolimatta potilaat kokivat ahdistusta samassa määrin kuin ennen leikkaustakin. Palvelujen käyttö vaihteli toipumisajan kuluessa ja potilaiden maksamissa kustannuksissa oli suuria vaihteluita. Fyysisen toimintakyvyn lisääntyminen ja kivun lieveneminen paransivat terveyteen liittyvää elämänlaatua. Sen sijaan huonompi elämänlaatu toipumisaikana oli yhteydessä suurempaan palvelujen käyttöön, kun taas kustannuksilla ei ollut yhteyttä elämänlaatuun. Potilaiden ominaispiirteet tulisi ottaa enemmän huomioon suunniteltaessa sopivaa leikkauksenjälkeistä hoitoa ja tukea. Potilaat tarvitsevat yksilöllisiä ohjeita, sillä monet taustatekijät (esim. ikä, sukupuoli, preoperatiivinen kipu, siviilisääty, ja leikkaustyyppi) vaikuttavat toipumiseen.
Resumo:
Kasvualustana käytetyn heikosti maatuneen rahkaturpeen lämmönjohtavuus
Resumo:
The safe use of nuclear power plants (NPPs) requires a deep understanding of the functioning of physical processes and systems involved. Studies on thermal hydraulics have been carried out in various separate effects and integral test facilities at Lappeenranta University of Technology (LUT) either to ensure the functioning of safety systems of light water reactors (LWR) or to produce validation data for the computer codes used in safety analyses of NPPs. Several examples of safety studies on thermal hydraulics of the nuclear power plants are discussed. Studies are related to the physical phenomena existing in different processes in NPPs, such as rewetting of the fuel rods, emergency core cooling (ECC), natural circulation, small break loss-of-coolant accidents (SBLOCA), non-condensable gas release and transport, and passive safety systems. Studies on both VVER and advanced light water reactor (ALWR) systems are included. The set of cases include separate effects tests for understanding and modeling a single physical phenomenon, separate effects tests to study the behavior of a NPP component or a single system, and integral tests to study the behavior of the whole system. In the studies following steps can be found, not necessarily in the same study. Experimental studies as such have provided solutions to existing design problems. Experimental data have been created to validate a single model in a computer code. Validated models are used in various transient analyses of scaled facilities or NPPs. Integral test data are used to validate the computer codes as whole, to see how the implemented models work together in a code. In the final stage test results from the facilities are transferred to the NPP scale using computer codes. Some of the experiments have confirmed the expected behavior of the system or procedure to be studied; in some experiments there have been certain unexpected phenomena that have caused changes to the original design to avoid the recognized problems. This is the main motivation for experimental studies on thermal hydraulics of the NPP safety systems. Naturally the behavior of the new system designs have to be checked with experiments, but also the existing designs, if they are applied in the conditions that differ from what they were originally designed for. New procedures for existing reactors and new safety related systems have been developed for new nuclear power plant concepts. New experiments have been continuously needed.
Resumo:
Vanerin tai kertopuun valmistusprosessissaviilun kuivaukseen käytetään suurin osa koko valmistusprosessin primäärienergiasta. Viilunkuivauskoneessa viilun sisältämä vesi siirretään tyypillisesti prosessihöyryllä lämmitettyyn viilunkuivaajan kiertoilmaan höyrystämällä ja poistetaanviilunkuivaajasta poistoilman mukana. Viilunkuivaajan poistoilma on lämmintä jaerittäin suuren kosteuspitoisuutensa takia sisältää runsaasti energiaa. Tyypillisellä viilunkuivaajalla poistoilmaan sitoutunut lämpöteho vaihtelee prosessiolosuhteista riippuen välillä 2,7-5,7 MW. Diplomityössä tutkittiin viilunkuivaajan poistoilman sisältämän lämmön talteenottoa laitteistolla, johon kuuluu lämmöntalteenottopesuri, jossa poistoilmalla lämmitetään tuotantolaitoksen tukkipuun hautomon kiertovettä sekä ilma-ilma-lämmönsiirrin, jolla lämmitetään pesurista poistuvan ilman jäännöslämmöllä ulkoilmaa tehdassalin tuloilmakäyttöön. Työn tavoitteena oli kehittää lämmöntalteenottojärjestelmän suunnittelua, mitoitusta ja ajotapoja. Työssä analysoitiin teoreettisesti pesuria ja ilmalämmönsiirrintä, kehitettiin lämmöntalteenottopesurin simulointimenetelmä ja mitattiin toiminnassa olevia talteenottolaitteistoja. Tutkimuksessa todettiin lämmöntalteenottohyötysuhteen vaihtelevan lämmityskaudella välillä 50-70 %. Lämmöntalteenottolaitteiston pesurin veteen saatava teho riippuu ensisijaisesti viilunkuivaajan poistoilman lämpösisällöstä, joka on enimmäkseen kosteusriippuvainen ja ilmanvaihtoilmaan saatava teho ulkolämpö-tilan määräämästä tehontarpeesta. Pesurin vesijärjestelmän vaikutusmekanismit pesurin suorituskykyyn tunnistettiin ja niiden pohjalta annetaan suositukset mitoitukseen ja ajotapaan. Lämmöntalteenottolaitteiston lämpötehon tasapainottamiseen pesurin ja ilma-ilma-lämmönsiirtimen välillä mitoituksen avulla esitellään työkalut.
Resumo:
Tämän työn tavoitteena oli selvittää erään ilmanvaihtokoneen lämmöntalteenottokennon vuosihyötysuhde japohtia voitaisiinko ilmastointikoneen energiatehokkuutta parantaa käyttämällä nykyisen ristivirtalämmönsiirtimen tilalla vastavirtalämmönsiirrintä tai poistoilmalämpöpumppua. Lisäksi tavoitteena oli mitata kahden ilmanvaihtokoneeseen liitettävän äänenvaimentimen vaimennuskyky ja pyrkiä parantamaan näiden vaimennusta. Työn teoriaosassa käsitellään yleisellä tasolla eri ilmanvaihtotapojen ja lämmöntalteenottomenetelmien toimintaperiaatteita ja soveltuvuuksiaeri tilanteisiin. Työn kokeellisessa osassa mitataan ilmanvaihtokoneen lämmöntalteenoton toiminta eri sääolosuhteissa ja lasketaan tulosten perusteella laitteelle lämpötila- ja entalpiavuosihyötysuhteet. Äänenvaimentimesta rakennetaan kaksi kehitysversiota, joiden mittaustuloksia verrataan alkuperäisen vaimentimen vaimennuskykyyn. Lämmöntalteenottoja vertailtaessa havaittiin, että suositeltavin kehitysvaihtoehto olisi vastavirtalämmönsiirtimeen siirtyminen sen yksinkertaisen rakenteen ja hyvän hyötysuhteen ansiosta.Äänenvaimentimien rakenteessa kannattaa mittausten ja pohdinnan perusteella siirtyä seinämillä jaettuun vaimentimeen.
Resumo:
Diplomityön tavoitteena on paineistimen yksityiskohtainen mallintaminen APROS- ja TRACE- termohydrauliikkaohjelmistoja käyttäen. Rakennetut paineistinmallit testattiin vertaamalla laskentatuloksia paineistimen täyttymistä, tyhjentymistä ja ruiskutusta käsittelevistä erilliskokeista saatuun mittausdataan. Tutkimuksen päätavoitteena on APROSin paineistinmallin validoiminen käyttäen vertailuaineistona PACTEL ATWS-koesarjan sopivia paineistinkokeita sekä MIT Pressurizer- ja Neptunus- erilliskokeita. Lisäksi rakennettiin malli Loviisan ydinvoimalaitoksen paineistimesta, jota käytettiin turbiinitrippitransientin simulointiin tarkoituksena selvittää mahdolliset voimalaitoksen ja koelaitteistojen mittakaavaerosta johtuvat vaikutukset APROSin paineistinlaskentaan. Kokeiden simuloinnissa testattiin erilaisia noodituksia ja mallinnusvaihtoehtoja, kuten entalpian ensimmäisen ja toisen kertaluvun diskretisointia, ja APROSin sekä TRACEn antamia tuloksia vertailtiin kattavasti toisiinsa. APROSin paineistinmallin lämmönsiirtokorrelaatioissa havaittiin merkittävä puute ja laskentatuloksiin saatiin huomattava parannus ottamalla käyttöön uusi seinämälauhtumismalli. Työssä tehdyt TRACE-simulaatiot ovat osa United States Nuclear Regulatory Commissionin kansainvälistä CAMP-koodinkehitys-ja validointiohjelmaa.
Resumo:
Uusia keinoja kullan erottamiseksi malmista on etsitty viimeaikoina taloudellisista ja ympäristöllisistä syistä kautta maailman. Syanidointimenetelmä on hallinnut kullan talteenottoayli sata vuotta. Menetelmässä kulta liuotetaan laimeaan syanidiliuokseen, jostase otetaan talteen aktiivihiilen avulla. Syanidin käyttöä pyritään kuitenkin vähentämään sen myrkyllisyyden takia. Lisäksi nykyään louhitaan enenemässä määrin malmia, josta on hankala rikastaa kulta kustannustehokkaasti syanidia käyttäen. Kullan talteenottoa syanidi- ja kloridiliuoksesta on selvitetty kirjallisuuden avulla. Kullan kemiaan liuotuksen aikana on perehdytty ennen kullan talteenottoa aktiivihiilellä. Aktiivihiilen elinkaari kullan adsorbenttinaon käsitelty valmistuksesta hylkäämiseen mukaan lukien hiilen myrkyttyminen prosessissa ja regenerointi. Aktiivi-hiilen käyttäytyminen syanidi- ja kloridiliuoksessa on selvitetty erikseen. Kullan talteenottoa kuparipitoisista malmeista on käsitelty. Kullan talteenottoa kloridiliuoksesta aktiivihiiltä käyttäen on tutkittu kokeellisesti. Pääasialliset tutkimuskohteet ovat adsorption kinetiikka, kuparin vaikutus adsorptioon, aktiivihiilen vaikutus adsorptioonja adsorboituneiden metallien strippaus hiilestä selektiivisesti. Hapettavan stippauksen vaikutus kullan desorptioon hiilestä on tutkittu yksityiskohtaisesti. Kullan erotusmenetelmät kuparimalmista aktiivihiiltä käyttäen on selvitetty diplomityön tulosten pohjalta. Diplomityön keskeisten tulosten perusteella kulta ei välttämättä saostu aktiivihiilen pinnalle kloridiliuoksesta. Havainto varmistettiin ladattujen hiilipartikkelien pyyhkäisyelektronimikroskooppikuvista ja partikkeleille tehdyistä mikroanalyyseistä. Kullan pelkistyminen metalliseksi kullaksi aktiivihiilessä voitaneen välttää käyttämällä erittäin hapettavia olosuhteita. Aktiivihiili ilmeisesti hapettuu näissä olosuhteissa, mikä mahdollistaa kultakloridin adsorboitumisen hiileen.
Resumo:
The fiber recovery process is an essential part of the modern paper mill. It creates the basisfor mill's internal recirculation of the most important raw materials ¿ water and fiber. It is normally also a start point for further treatment of wastewater and if it works efficiently, it offers excellent basis to minimize effluents. This dissertation offers two different approaches to the subject. Firstly a novel save-all disc filter feeding system is developed and presented. This so-called precoat method is tested both in the laboratory and full-scale conditions. In laboratory scale it beats the traditional one clearly, when low freeness pulps are used as a sweetener stock. The full-scale application needs still some development work before it can be implemented to the paper mills. Secondly, the operationenvironment of save-all disc filter is studied mostly in laboratory conditions.The focus of this study is in cases, where low-freeness pulps are used as a sweetener stock of save-all filter. The effects of CSF-value, pressure drop, suspension consistency and retention chemicals to the quantity and quality of the filtrate was studied. Also the filtration resistance of the low freeness pulps was one studied.
Resumo:
This thesis gives an overview of the validation process for thermal hydraulic system codes and it presents in more detail the assessment and validation of the French code CATHARE for VVER calculations. Three assessment cases are presented: loop seal clearing, core reflooding and flow in a horizontal steam generator. The experience gained during these assessment and validation calculations has been used to analyze the behavior of the horizontal steam generator and the natural circulation in the geometry of the Loviisa nuclear power plant. The cases presented are not exhaustive, but they give a good overview of the work performed by the personnel of Lappeenranta University of Technology (LUT). Large part of the work has been performed in co-operation with the CATHARE-team in Grenoble, France. The design of a Russian type pressurized water reactor, VVER, differs from that of a Western-type PWR. Most of thermal-hydraulic system codes are validated only for the Western-type PWRs. Thus, the codes should be assessed and validated also for VVER design in order to establish any weaknesses in the models. This information is needed before codes can be used for the safety analysis. Theresults of the assessment and validation calculations presented here show that the CATHARE code can be used also for the thermal-hydraulic safety studies for VVER type plants. However, some areas have been indicated which need to be reassessed after further experimental data become available. These areas are mostly connected to the horizontal stem generators, like condensation and phase separation in primary side tubes. The work presented in this thesis covers a large numberof the phenomena included in the CSNI code validation matrices for small and intermediate leaks and for transients. Also some of the phenomena included in the matrix for large break LOCAs are covered. The matrices for code validation for VVER applications should be used when future experimental programs are planned for code validation.