29 resultados para Speed control humps.
em Doria (National Library of Finland DSpace Services) - National Library of Finland, Finland
Resumo:
The pumping processes requiring wide range of flow are often equipped with parallelconnected centrifugal pumps. In parallel pumping systems, the use of variable speed control allows that the required output for the process can be delivered with a varying number of operated pump units and selected rotational speed references. However, the optimization of the parallel-connected rotational speed controlled pump units often requires adaptive modelling of both parallel pump characteristics and the surrounding system in varying operation conditions. The available information required for the system modelling in typical parallel pumping applications such as waste water treatment and various cooling and water delivery pumping tasks can be limited, and the lack of real-time operation point monitoring often sets limits for accurate energy efficiency optimization. Hence, alternatives for easily implementable control strategies which can be adopted with minimum system data are necessary. This doctoral thesis concentrates on the methods that allow the energy efficient use of variable speed controlled parallel pumps in system scenarios in which the parallel pump units consist of a centrifugal pump, an electric motor, and a frequency converter. Firstly, the suitable operation conditions for variable speed controlled parallel pumps are studied. Secondly, methods for determining the output of each parallel pump unit using characteristic curve-based operation point estimation with frequency converter are discussed. Thirdly, the implementation of the control strategy based on real-time pump operation point estimation and sub-optimization of each parallel pump unit is studied. The findings of the thesis support the idea that the energy efficiency of the pumping can be increased without the installation of new, more efficient components in the systems by simply adopting suitable control strategies. An easily implementable and adaptive control strategy for variable speed controlled parallel pumping systems can be created by utilizing the pump operation point estimation available in modern frequency converters. Hence, additional real-time flow metering, start-up measurements, and detailed system model are unnecessary, and the pumping task can be fulfilled by determining a speed reference for each parallel-pump unit which suggests the energy efficient operation of the pumping system.
Resumo:
Data transmission between an electric motor and a frequency converter is required in variablespeed electric drives because of sensors installed at the motor. Sensor information can be used for various useful applications to improve the system reliability and its properties. Traditionally, the communication medium is implemented by an additional cabling. However, the costs of the traditional method may be an obstacle to the wider application of data transmission between a motor and a frequency converter. In any case, a power cable is always installed between a motor and a frequency converter for power supply, and hence it may be applied as a communication medium for sensor level data. This thesis considers power line communication (PLC) in inverter-fed motor power cables. The motor cable is studied as a communication channel in the frequency band of 100 kHz−30 MHz. The communication channel and noise characteristics are described. All the individual components included in a variable-speed electric drive are presented in detail. A channel model is developed, and it is verified by measurements. A theoretical channel information capacity analysis is carried out to estimate the opportunities of a communication medium. Suitable communication and forward error correction (FEC) methods are suggested. A general method to implement a broadband and Ethernet-based communication medium between a motor and a frequency converter is proposed. A coupling interface is also developed that allows to install the communication device safely to a three-phase inverter-fed motor power cable. Practical tests are carried out, and the results are analyzed. Possible applications for the proposed method are presented. A speed feedback motor control application is verified in detail by simulations and laboratory tests because of restrictions for the delay in the feedback loop caused by PLC. Other possible applications are discussed at a more general level.
Resumo:
Over the recent years, development in mobile working machines has concentrated on reducing emissions owing to the tightening rules and needs to improve energy utilization and reduce power losses. This study focuses on energy utilization and regeneration in an electro-hydraulic forklift, which is a lifting equipment application. The study starts from the modelling and simulation of a hydraulic forklift. The energy regeneration from the potential energy of the load was studied. Also a flow-based electric motor speed control was suggested in this thesis instead of the throttle control method or the variable displacement pump control. Topics related to further development in the future are discussed. Finally, a summary and conclusions are presented.
Resumo:
The integration of electric motors and industrial appliances such as pumps, fans, and compressors is rapidly increasing. For instance, the integration of an electric motor and a centrifugal pump provides cost savings and improved performance characteristics. Material cost savings are achieved when an electric motor is integrated into the shaft of a centrifugal pump, and the motor utilizes the bearings of the pump. This arrangement leads to a smaller configuration that occupies less floor space. The performance characteristics of a pump drive can be improved by using the variable-speed technology. This enables the full speed control of the drive and the absence of a mechanical gearbox and couplers. When using rotational speeds higher than those that can be directly achieved by the network frequency the structure of the rotor has to be mechanically durable. In this thesis the performance characteristics of an axial-flux solid-rotor-core induction motor are determined. The motor studied is a one-rotor-one-stator axial-flux induction motor, and thus, there is only one air-gap between the rotor and the stator. The motor was designed for higher rotational speeds, and therefore a good mechanical strength of the solid-rotor-core rotor is required to withstand the mechanical stresses. The construction of the rotor and the high rotational speeds together produce a feature, which is not typical of traditional induction motors: the dominating loss component of the motor is the rotor eddy current loss. In the case of a typical industrial induction motor instead the dominating loss component is the stator copper loss. In this thesis, several methods to decrease the rotor eddy current losses in the case of axial-flux induction motors are presented. A prototype motor with 45 kW output power at 6000 min-1 was designed and constructed for ascertaining the results obtained from the numerical FEM calculations. In general, this thesis concentrates on the methods for improving the electromagnetic properties of an axial-flux solid-rotor-core induction motor and examines the methods for decreasing the harmonic eddy currents of the rotor. The target is to improve the efficiency of the motor and to reach the efficiency standard of the present-day industrial induction motors equipped with laminated rotors.
Resumo:
Työssä rakennettiin integroitu simulointimalli sähkökäytölle, jonka mekaniikka koostuu joustava-akselisesta kaksimassa systeemistä. Lisäksi tarkasteltiin kyseiselle sähkökäytölle ominaisia piirteitä ja niiden aiheuttamia ongelmia eri sovelluksissa, sekä tutkittiin teollisuudessa yleisesti esiintyvän pyörimisnopeussäädön, PI-säädön, parametrien vaikutusta kyseisen mekaniikan omaaviin sähkökäyttöihin. Taajuusmuuttajalle kehiteltiin yksinkertaistettu simulointimalli, jolla pystytään pienentämään merkittävästi simuloinnin laskenta-aikaa. Vääntövärähtelyiden kompensointiin tutkittiin optimaalista tilasäätöä, jossa Kalman suotimella estimoidaan systeemin tilojen lisäksi myös kuormamomentti ja jossa nopeussäätö suunnitellaan lineaarisella neliöllisellä menetelmällä (Linear Quadratic).
Resumo:
Työn tavoitteena oli uudentyyppisen hiontaprosessin ohjausjärjestelmän kehittäminen ja testaaminen UPM-Kymmene Kaukaan hiomossa. Uuden ohjausjärjestelmän perusajatuksena oli pitää yksittäistä hiomakiveä jatkuvasti optimaalisessa toimintapisteessä, ja hiomon kaikilla koneilla pyrittiin samaan kivenalusmassan laatuun. Uutta ohjaustapaa kutsuttiin Optimum operating point -strategiaksi (OOPS). Hiomakiven pitäminen optimaalisessa toimintapisteessä tapahtui pääosin vesiteräyskäsittelyllä, jonka intensiteettiä ohjasi asiantuntijajärjestelmä (AI-järjestelmä). Lisäksi testattiin ohjelmoidun anturan nopeussäädön vaikutusta hiomakoneen resurssien käyttöön. AI-järjestelmä päätteli vesiteräyskäsittelyn tarpeellisuuden CSF-mallin ja hiomakoneen resurssien perusteella. Seurannasta saatujen tulosten perusteella AI-järjestelmän käyttöönotto vesiteräyskäsittelyssä paransi tuotannon ja massan laadun tasaisuutta. Hiomakoneiden resurssien havaittiin pienenevän puunsyöttölinjan mukaisesti. Paksummat pöllit kerääntyvät linjan päähän, jolloin varsinkin hydrauliikkapaineiden tarve lisääntyy linjan päässä olevilla hiomakoneilla. Hiomakoneen resurssit saatiin paremmin käyttöön kuormittamalla konetta ohjelmoidulla anturan nopeussäädöllä (ONS) kuin vakioidulla anturan nopeussäädöllä (VNS). Kuitenkin hydraulipaineresurssien puutteellisuus rajoitti koeajon aikana ONS:n toimintaa. Resursseja ei optimoitu koeajon aikana, koska kiven pinnan haluttiin pysyvän mahdollisimman stabiilina. Kivelle ei suoritettu mekaanista käsittelyä, vaikka kivenpinnan massan kuljetuskapasiteetin havaittiin olevan huono. AI-järjestelmä otettiin ohjaamaan vesiteräyskäsittelyä vasta ONS - VNS -koeajon jälkeen. Mekaanisen rullateräyksen jälkeen massan ominaisuudet muuttuivat, koska kiven pinnan terävät särmät katkoivat kuituja alentaen massan sitoutumiskykyä. Heti rullakäsittelyn jälkeen mitattu CSF saattoi jopa alentua huomattavasti, mutta AI-järjestelmän laskema CSF nousi selvästi indikoiden energian ominaiskulutuksen (EOK) laskua. Muutaman päivän hionnan jälkeen mitattu ja laskettu CSF saavuttivat saman tason.
Resumo:
Työn ensimmäisessä osassa tutustutaan pumppauksen teoriaan ja esitellään kuristus- ja pyörimisnopeussäätö. Toisessa osassa perehdytään pyörimisnopeussäädössä käytettävän taajuusmuuttajan rakenteeseen ja sen eri osissa syntyviin häviöihin. Kolmannessa osassa tutkitaan kolmen eri tavoin säädetyn pumppauksen toimintaa Pelloksen voimalaitoksella. Lauhdepumpun kierrosnopeussäätöä verrataan vaihtoehtoiseen kuristussäätöön. Viimeisessä osassa selvitetään mahdollisuutta poistaa pyörimisnopeussäädön turhaksi tekemä syöttövesiventtiili voimalaitosten suunnittelusta. Erityisesti etsitään vaihtoehtoisia menetelmiä ruiskutusveden tuottamiseen. Uusia vaihtoehtoja ruiskutusvedelle esitetään kaksitoista. Ruiskutusvesitekniikoita vertaillaan keskenään ja parasta vaihtoehtoa verrataan nykyiseen menettelyyn.
Resumo:
Työssä pyrittiin etsimään differentiaalievoluutioalgoritmilla kaksiakseliselle, välijäähdytyksellä, välipoltolla ja rekuperaattorilla varustetulle mikrokaasuturbiinille sellaiset kompressorien painesuhteet ja rekuperaattorin rekuperaatioaste, että saavutettaisiin mandollisimman hyvä osakuormahyötysuhteen säilyvyys. Osakuormatehon säätömenetelmäksi oli valittu pyörimisnopeussäädön ja turbiinien sisääntulolämpötilan alentamisen yhdistelmä, jossa generaattorilla varustetun akselin pyörimisnopeus sekä molempien turbiinien sisääntulolämpötilat olivat toisistaan riippumatta vapaasti säädettävissä. Työssä löydettiin optimaalinen säätömenetelmien yhdistelmä, jolla saavutetaan parempi osakuormahyötysuhteen säilyvyys, kuin millään käytetyistä menetelmistä yksinään. Lisäksi havaittiin, ettei optimaalinen säätömenetelmä merkittävästi riipu koneikolle valituista suunnittelupisteen parametreista. Osakuormahyötysuhteen säilyvyyden kannalta optimaalinen koneikko ei merkittävästi poikennut suunnittelupisteen hyötysuhteen kannalta optimaalisesta.
Resumo:
Painelajittimet ovat yleisimpiä hiokkeen lajitteluun käytettyjä lajittimia. Painelajittimien suorituskyky on parantunut viimeisten vuosikymmenien aikana niin paljon, että pyörrepuhdistuksesta on pääosin voitu luopua osana hiokkeen lajittelua. Painelajittimen erinomaisuus perustuu siihen, että sillä voidaan erottaa massasta hyvinkin erilaisia epäpuhtauksia. Nykyään vallitsevia painelajittelun trendejä ovat sakeuden nosto, energiankulutuksen vähentäminen sekä eri fraktioiden erottumisen tehostuminen. Kaikilla pyritään vähentämään vedenkäyttöä ja parantamaan massan ominaisuuksia jatkoprosesseja silmälläpitäen. Tässä työssä tarkasteltiin painelajittimen roottorin kierrosnopeuden vaikutusta akseptimassan laatuun. Luodaan malli freeness-pudotukselle lajittimen yli. Sekä tarkastellaan myös automaatioon pohjautuvan säädön käyttöönottoa lajittimen akseptimassan freenesvaihteluiden tasaamiseksi. Toisaalta tehdään myös suppea selvitys lajittimien energiankulutuksista erilaisilla roottorin pyörimisnopeuksilla. Tuotantokäytössä oleviin lajittimiin asennettujen invertterisäätöjen ja koepisteistä saatujen tulosten avulla voidaan todeta, että laskemalla roottorin pyörimisnopeutta voidaan lajittimessa tapahtuvaa freenespudotusta kasvattaa. Samalla saavutetaan hyötyjä myös muissa massan ominaisuuksissa, kuten vetolujuudessa. Automaattisäädön käyttöönotolla saavutetaan huomattavasti pienempi hajonta akseptimassan freeneksessä. Rejektilinjan lajittimissa hajonta lähes puolittui ja päälinjan lajittimissa päästiin noin kolmanneksen parannukseen. Energian kulutuksia tutkittaessa huomataan, että roottorin kierrosnopeutta alentamalla voidaan merkittävästi vähentää lajittimien energian kulutusta. Parhaassa tapauksessa voidaan säästää neljännes lajittelun energiakustannuksissa.
Resumo:
Centrifugal pumps are widely used in industrial and municipal applications, and they are an important end-use application of electric energy. However, in many cases centrifugal pumps operate with a significantly lower energy efficiency than they actually could, which typically has an increasing effect on the pump energy consumption and the resulting energy costs. Typical reasons for this are the incorrect dimensioning of the pumping system components and inefficiency of the applied pump control method. Besides the increase in energy costs, an inefficient operation may increase the risk of a pump failure and thereby the maintenance costs. In the worst case, a pump failure may lead to a process shutdown accruing additional costs. Nowadays, centrifugal pumps are often controlled by adjusting their rotational speed, which affects the resulting flow rate and output pressure of the pumped fluid. Typically, the speed control is realised with a frequency converter that allows the control of the rotational speed of an induction motor. Since a frequency converter can estimate the motor rotational speed and shaft torque without external measurement sensors on the motor shaft, it also allows the development and use of sensorless methods for the estimation of the pump operation. Still today, the monitoring of pump operation is based on additional measurements and visual check-ups, which may not be applicable to determine the energy efficiency of the pump operation. This doctoral thesis concentrates on the methods that allow the use of a frequency converter as a monitoring and analysis device for a centrifugal pump. Firstly, the determination of energy-efficiency- and reliability-based limits for the recommendable operating region of a variable-speed-driven centrifugal pump is discussed with a case study for the laboratory pumping system. Then, three model-based estimation methods for the pump operating location are studied, and their accuracy is determined by laboratory tests. In addition, a novel method to detect the occurrence of cavitation or flow recirculation in a centrifugal pump by a frequency converter is introduced. Its sensitivity compared with known cavitation detection methods is evaluated, and its applicability is verified by laboratory measurements for three different pumps and by using two different frequency converters. The main focus of this thesis is on the radial flow end-suction centrifugal pumps, but the studied methods can also be feasible with mixed and axial flow centrifugal pumps, if allowed by their characteristics.
Resumo:
This thesis presents briefly the basic operation and use of centrifugal pumps and parallel pumping applications. The characteristics of parallel pumping applications are compared to circuitry, in order to search analogy between these technical fields. The purpose of studying circuitry is to find out if common software tools for solving circuit performance could be used to observe parallel pumping applications. The empirical part of the thesis introduces a simulation environment for parallel pumping systems, which is based on circuit components of Matlab Simulink —software. The created simulation environment ensures the observation of variable speed controlled parallel pumping systems in case of different controlling methods. The introduced simulation environment was evaluated by building a simulation model for actual parallel pumping system at Lappeenranta University of Technology. The simulated performance of the parallel pumps was compared to measured values of the actual system. The gathered information shows, that if the initial data of the system and pump perfonnance is adequate, the circuitry based simulation environment can be exploited to observe parallel pumping systems. The introduced simulation environment can represent the actual operation of parallel pumps in reasonably accuracy. There by the circuitry based simulation can be used as a researching tool to develop new controlling ways for parallel pumps.
Resumo:
Työn tavoitteena oli tutkia HSR(High Speed Release)-mittausmenetelmän käyttämistä tarralaminaattiprosessin ohjauksessa UPM Raflatacissa. Nykyisin käytössä olevaan LSR(Low Speed Release)-menetelmään verrattuna HSR-menetelmä kuvaa paremmin tarralaminaatin jatkojalostuksessa sekä etiketöinnissä tapahtuvaa irrotustyötä. Lisäksi työssä tutkittiin irrotusnopeuden vaikutusta HSR-arvoon. Työn kirjallisuusosassa perehdyttiin tarralaminaatin rakenteeseensekä valmistusprosessiin. Koska silikonin valinnalla on merkittävä vaikutus tarralaminaatin releasearvoon, kirjallisessa osassa syvennytään tarkastelemaan tarralaminaatin valmistuksessa käytettyjä silikoneja sekänäiden rakennetta. Kirjallisuusosassa on myös käsitelty muita releasetasoon vaikuttavia tekijöitä. Työn kokeellisessa osassa oli tarkoituksena tutkia HSR-mittausmenetelmän käytettävyyttä tarralaminaatin prosessinohjauksessa. Tätä tutkittiin selvittämällä nykyisin käytössä olevan LSR-menetelmän sekä HSR-menetelmän välistä korreloituvuutta. Mikäli näidenvälillä olisi korreloituvuutta, voitaisiin prosessinohjauksessa ajatella siirtyvän HSR-mittaukseen. Korrelaatiota näiden kahden menetelmän välille ei kuitenkaan löydetty. Työssä tutkittiin myös irrotusnopeuden vaikutusta tuotteen HSR-arvoon. Testeihin valittiin useita eri tuotteita useilta tuotantolaitoksilta. Kaikilla näillä tuotteilla releasearvo kasvoi irrotusnopeutta lisättäessä. Lisäksi työssä määritettiin uudet HSR-spesifikaatiot tietyille tuotteille. Kaikille UPM Raflatacin tuotteille on määritetty LSRspesifikaatiot, HSR-spesifikaatiot on asetettu vain tietyille tuotteille.
Resumo:
Pulsewidth-modulated (PWM) rectifier technology is increasingly used in industrial applications like variable-speed motor drives, since it offers several desired features such as sinusoidal input currents, controllable power factor, bidirectional power flow and high quality DC output voltage. To achieve these features,however, an effective control system with fast and accurate current and DC voltage responses is required. From various control strategies proposed to meet these control objectives, in most cases the commonly known principle of the synchronous-frame current vector control along with some space-vector PWM scheme have been applied. Recently, however, new control approaches analogous to the well-established direct torque control (DTC) method for electrical machines have also emerged to implement a high-performance PWM rectifier. In this thesis the concepts of classical synchronous-frame current control and DTC-based PWM rectifier control are combined and a new converter-flux-based current control (CFCC) scheme is introduced. To achieve sufficient dynamic performance and to ensure a stable operation, the proposed control system is thoroughly analysed and simple rules for the controller design are suggested. Special attention is paid to the estimationof the converter flux, which is the key element of converter-flux-based control. Discrete-time implementation is also discussed. Line-voltage-sensorless reactive reactive power control methods for the L- and LCL-type line filters are presented. For the L-filter an open-loop control law for the d-axis current referenceis proposed. In the case of the LCL-filter the combined open-loop control and feedback control is proposed. The influence of the erroneous filter parameter estimates on the accuracy of the developed control schemes is also discussed. A newzero vector selection rule for suppressing the zero-sequence current in parallel-connected PWM rectifiers is proposed. With this method a truly standalone and independent control of the converter units is allowed and traditional transformer isolation and synchronised-control-based solutions are avoided. The implementation requires only one additional current sensor. The proposed schemes are evaluated by the simulations and laboratory experiments. A satisfactory performance and good agreement between the theory and practice are demonstrated.
Resumo:
The present study was done with two different servo-systems. In the first system, a servo-hydraulic system was identified and then controlled by a fuzzy gainscheduling controller. The second servo-system, an electro-magnetic linear motor in suppressing the mechanical vibration and position tracking of a reference model are studied by using a neural network and an adaptive backstepping controller respectively. Followings are some descriptions of research methods. Electro Hydraulic Servo Systems (EHSS) are commonly used in industry. These kinds of systems are nonlinearin nature and their dynamic equations have several unknown parameters.System identification is a prerequisite to analysis of a dynamic system. One of the most promising novel evolutionary algorithms is the Differential Evolution (DE) for solving global optimization problems. In the study, the DE algorithm is proposed for handling nonlinear constraint functionswith boundary limits of variables to find the best parameters of a servo-hydraulic system with flexible load. The DE guarantees fast speed convergence and accurate solutions regardless the initial conditions of parameters. The control of hydraulic servo-systems has been the focus ofintense research over the past decades. These kinds of systems are nonlinear in nature and generally difficult to control. Since changing system parameters using the same gains will cause overshoot or even loss of system stability. The highly non-linear behaviour of these devices makes them ideal subjects for applying different types of sophisticated controllers. The study is concerned with a second order model reference to positioning control of a flexible load servo-hydraulic system using fuzzy gainscheduling. In the present research, to compensate the lack of dampingin a hydraulic system, an acceleration feedback was used. To compare the results, a pcontroller with feed-forward acceleration and different gains in extension and retraction is used. The design procedure for the controller and experimental results are discussed. The results suggest that using the fuzzy gain-scheduling controller decrease the error of position reference tracking. The second part of research was done on a PermanentMagnet Linear Synchronous Motor (PMLSM). In this study, a recurrent neural network compensator for suppressing mechanical vibration in PMLSM with a flexible load is studied. The linear motor is controlled by a conventional PI velocity controller, and the vibration of the flexible mechanism is suppressed by using a hybrid recurrent neural network. The differential evolution strategy and Kalman filter method are used to avoid the local minimum problem, and estimate the states of system respectively. The proposed control method is firstly designed by using non-linear simulation model built in Matlab Simulink and then implemented in practical test rig. The proposed method works satisfactorily and suppresses the vibration successfully. In the last part of research, a nonlinear load control method is developed and implemented for a PMLSM with a flexible load. The purpose of the controller is to track a flexible load to the desired position reference as fast as possible and without awkward oscillation. The control method is based on an adaptive backstepping algorithm whose stability is ensured by the Lyapunov stability theorem. The states of the system needed in the controller are estimated by using the Kalman filter. The proposed controller is implemented and tested in a linear motor test drive and responses are presented.
Resumo:
Thedirect torque control (DTC) has become an accepted vector control method besidethe current vector control. The DTC was first applied to asynchronous machines,and has later been applied also to synchronous machines. This thesis analyses the application of the DTC to permanent magnet synchronous machines (PMSM). In order to take the full advantage of the DTC, the PMSM has to be properly dimensioned. Therefore the effect of the motor parameters is analysed taking the control principle into account. Based on the analysis, a parameter selection procedure is presented. The analysis and the selection procedure utilize nonlinear optimization methods. The key element of a direct torque controlled drive is the estimation of the stator flux linkage. Different estimation methods - a combination of current and voltage models and improved integration methods - are analysed. The effect of an incorrect measured rotor angle in the current model is analysed andan error detection and compensation method is presented. The dynamic performance of an earlier presented sensorless flux estimation method is made better by improving the dynamic performance of the low-pass filter used and by adapting the correction of the flux linkage to torque changes. A method for the estimation ofthe initial angle of the rotor is presented. The method is based on measuring the inductance of the machine in several directions and fitting the measurements into a model. The model is nonlinear with respect to the rotor angle and therefore a nonlinear least squares optimization method is needed in the procedure. A commonly used current vector control scheme is the minimum current control. In the DTC the stator flux linkage reference is usually kept constant. Achieving the minimum current requires the control of the reference. An on-line method to perform the minimization of the current by controlling the stator flux linkage reference is presented. Also, the control of the reference above the base speed is considered. A new estimation flux linkage is introduced for the estimation of the parameters of the machine model. In order to utilize the flux linkage estimates in off-line parameter estimation, the integration methods are improved. An adaptive correction is used in the same way as in the estimation of the controller stator flux linkage. The presented parameter estimation methods are then used in aself-commissioning scheme. The proposed methods are tested with a laboratory drive, which consists of a commercial inverter hardware with a modified software and several prototype PMSMs.