51 resultados para Signal generation

em Doria (National Library of Finland DSpace Services) - National Library of Finland, Finland


Relevância:

60.00% 60.00%

Publicador:

Resumo:

A novel cantilever pressure sensor was developed in the Department of Physics at the University of Turku in order to solve the sensitivity problems which are encountered when condenser microphones are used in photoacoustic spectroscopy. The cantilever pressure sensor, combined with a laser interferometer for the measurement of the cantilever movements, proved to be highly sensitive. The original aim of this work was to integrate the sensor in a photoacoustic gas detector working in a differential measurement scheme. The integration was made successfully into three prototypes. In addition, the cantilever was also integrated in the photoacoustic FTIR measurement schemes of gas-, liquid-, and solid-phase samples. A theoretical model for the signal generation in each measurement scheme was created and the optimal celldesign discussed. The sensitivity and selectivity of the differential method were evaluated when a blackbody radiator and a mechanical chopper were used with CO2, CH4, CO, and C2H4 gases. The detection limits were in the sub-ppm level for all four gases with only a 1.3 second integration time and the cross interference was well below one percent for all gas combinations other than those between hydrocarbons. Sensitivity with other infrared sources was compared using ethylene as an example gas. In the comparison of sensitivity with different infrared sources the electrically modulated blackbody radiator gave a 35 times higher and the CO2-laser a 100 times lower detection limit than the blackbody radiator with a mechanical chopper. As a conclusion, the differential system is well suited to rapid single gas measurements. Gas-phase photoacoustic FTIR spectroscopy gives the best performance, when several components have to be analyzed simultaneously from multicomponent samples. Multicomponent measurements were demonstrated with a sample that contained different concentrations of CO2, H2O, CO, and four different hydrocarbons. It required an approximately 10 times longer measurement time to achieve the same detection limit for a single gas as with the differential system. The properties of the photoacoustic FTIR spectroscopy were also compared to conventional transmission FTIR spectroscopy by simulations. Solid- and liquid-phase photoacoustic FTIR spectroscopy has several advantages compared to other techniques and therefore it also has a great variety of applications. A comparison of the signal-to-noise ratio between photoacoustic cells with a cantilever microphone and a condenser microphone was done with standard carbon black, polyethene, and sunflower oil samples. The cell with the cantilever microphone proved to have a 5-10 times higher signal-to-noise ratio than the reference detector, depending on the sample. Cantilever enhanced photoacoustics will be an effective tool for gas detection and analysis of solid- and liquid-phase samples. The preliminary prototypes gave good results in all three measurement schemes that were studied. According to simulations, there are possibilities for further enhancement of the sensitivity, as well as other properties, of each system.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This dissertation considers the segmental durations of speech from the viewpoint of speech technology, especially speech synthesis. The idea is that better models of segmental durations lead to higher naturalness and better intelligibility. These features are the key factors for better usability and generality of synthesized speech technology. Even though the studies are based on a Finnish corpus the approaches apply to all other languages as well. This is possibly due to the fact that most of the studies included in this dissertation are about universal effects taking place on utterance boundaries. Also the methods invented and used here are suitable for any other study of another language. This study is based on two corpora of news reading speech and sentences read aloud. The other corpus is read aloud by a 39-year-old male, whilst the other consists of several speakers in various situations. The use of two corpora is twofold: it involves a comparison of the corpora and a broader view on the matters of interest. The dissertation begins with an overview to the phonemes and the quantity system in the Finnish language. Especially, we are covering the intrinsic durations of phonemes and phoneme categories, as well as the difference of duration between short and long phonemes. The phoneme categories are presented to facilitate the problem of variability of speech segments. In this dissertation we cover the boundary-adjacent effects on segmental durations. In initial positions of utterances we find that there seems to be initial shortening in Finnish, but the result depends on the level of detail and on the individual phoneme. On the phoneme level we find that the shortening or lengthening only affects the very first ones at the beginning of an utterance. However, on average, the effect seems to shorten the whole first word on the word level. We establish the effect of final lengthening in Finnish. The effect in Finnish has been an open question for a long time, whilst Finnish has been the last missing piece for it to be a universal phenomenon. Final lengthening is studied from various angles and it is also shown that it is not a mere effect of prominence or an effect of speech corpus with high inter- and intra-speaker variation. The effect of final lengthening seems to extend from the final to the penultimate word. On a phoneme level it reaches a much wider area than the initial effect. We also present a normalization method suitable for corpus studies on segmental durations. The method uses an utterance-level normalization approach to capture the pattern of segmental durations within each utterance. This prevents the impact of various problematic variations within the corpora. The normalization is used in a study on final lengthening to show that the results on the effect are not caused by variation in the material. The dissertation shows an implementation and prowess of speech synthesis on a mobile platform. We find that the rule-based method of speech synthesis is a real-time software solution, but the signal generation process slows down the system beyond real time. Future aspects of speech synthesis on limited platforms are discussed. The dissertation considers ethical issues on the development of speech technology. The main focus is on the development of speech synthesis with high naturalness, but the problems and solutions are applicable to any other speech technology approaches.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Point-of-care (POC) –diagnostics is a field with rapidly growing market share. As these applications become more widely used, there is an increasing pressure to improve their performance to match the one of a central laboratory tests. Lanthanide luminescence has been widely utilized in diagnostics because of the numerous advantages gained by the utilization of time-resolved or anti-Stokes detection. So far the use of lanthanide labels in POC has been scarce due to limitations set by the instrumentation required for their detection and the shortcomings, e.g. low brightness, of these labels. Along with the advances in the research of lanthanide luminescence, and in the field of semiconductors, these materials are becoming a feasible alternative for the signal generation also in the future POC assays. The aim of this thesis was to explore ways of utilizing time-resolved detection or anti-Stokes detection in POC applications. The long-lived fluorescence for the time-resolved measurement can be produced with lanthanide chelates. The ultraviolet (UV) excitation required by these chelates is cumbersome to produce with POC compatible fluorescence readers. In this thesis the use of a novel light-harvesting ligand was studied. This molecule can be used to excite Eu(III)-ions at wavelengths extending up to visible part of the spectrum. An enhancement solution based on this ligand showed a good performance in a proof-of-concept -bioaffinity assay and produced a bright signal upon 365 nm excitation thanks to the high molar absorptivity of the chelate. These features are crucial when developing miniaturized readers for the time-resolved detection of fluorescence. Upconverting phosphors (UCPs) were studied as an internal light source in glucose-sensing dry chemistry test strips and ways of utilizing their various emission wavelengths and near-infrared excitation were explored. The use of nanosized NaYF :Yb3+,Tm3+-particles enabled the replacement of an external UV-light source with a NIR-laser and gave an additional degree of freedom in the optical setup of the detector instrument. The new method enabled a blood glucose measurement with results comparable to a current standard method of measuring reflectance. Microsized visible emitting UCPs were used in a similar manner, but with a broad absorbing indicator compound filtering the excitation and emission wavelengths of the UCP. This approach resulted in a novel way of benefitting from the non-linear relationship between the excitation power and emission intensity of the UCPs, and enabled the amplification of the signal response from the indicator dye.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The research of condition monitoring of electric motors has been wide for several decades. The research and development at universities and in industry has provided means for the predictive condition monitoring. Many different devices and systems are developed and are widely used in industry, transportation and in civil engineering. In addition, many methods are developed and reported in scientific arenas in order to improve existing methods for the automatic analysis of faults. The methods, however, are not widely used as a part of condition monitoring systems. The main reasons are, firstly, that many methods are presented in scientific papers but their performance in different conditions is not evaluated, secondly, the methods include parameters that are so case specific that the implementation of a systemusing such methods would be far from straightforward. In this thesis, some of these methods are evaluated theoretically and tested with simulations and with a drive in a laboratory. A new automatic analysis method for the bearing fault detection is introduced. In the first part of this work the generation of the bearing fault originating signal is explained and its influence into the stator current is concerned with qualitative and quantitative estimation. The verification of the feasibility of the stator current measurement as a bearing fault indicatoris experimentally tested with the running 15 kW induction motor. The second part of this work concentrates on the bearing fault analysis using the vibration measurement signal. The performance of the micromachined silicon accelerometer chip in conjunction with the envelope spectrum analysis of the cyclic bearing faultis experimentally tested. Furthermore, different methods for the creation of feature extractors for the bearing fault classification are researched and an automatic fault classifier using multivariate statistical discrimination and fuzzy logic is introduced. It is often important that the on-line condition monitoring system is integrated with the industrial communications infrastructure. Two types of a sensor solutions are tested in the thesis: the first one is a sensor withcalculation capacity for example for the production of the envelope spectra; the other one can collect the measurement data in memory and another device can read the data via field bus. The data communications requirements highly depend onthe type of the sensor solution selected. If the data is already analysed in the sensor the data communications are needed only for the results but in the other case, all measurement data need to be transferred. The complexity of the classification method can be great if the data is analysed at the management level computer, but if the analysis is made in sensor itself, the analyses must be simple due to the restricted calculation and memory capacity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Remote diagnostics has become very popular in marine industry. Diagnostic systems are improved all the time and the newest monitoring systems are constantly taken into operation. Most vessels are, however, rigged up by outmoded facilities, which should be updated. In this work the principles of operating of such a remote diagnostic system as the ABB's third generation remote diagnostic system (RDS) and the newest Propulsion Condition Management System (PCMS) are studied. As a result of the thesis the ways of upgrading the old systems of RDS are presented. Specifically, the work focuses on the establishment of the connection between Advant controller AC-110 from the old system and PCMS server, and in other words how to get Modbus data by OPC server.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The reformation of power sector is still in the process of development. The present day situation in Russian electricity power market ischaracterized as transitional period: competitive electricity market is forming, new companies are being created and the power of government regulation is decreasing. The main aim of the reformation is to attract much-needed private investments to the power sector. The electricity consumption increases very rapidly and power sector has to cope with high demand. The goal of this master's thesis is to analyze the nowadays situation in Russian power sector, such as generation structure, condition of electricity networks, electricity price formation for end-users, shape of fuel sector and investments risks and attraction.The final result of this work is creation of scenario of Russian power sector future shape and analysis of the present day situation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Verkkoon kytkettävien laitteiden määrä on lisääntynyt viime vuosina, joka luo tarpeen reitittimille ja niiden ominaisuuksille. On muodostunut uusi tarve laitteille, jotka voivat yhdistää erilaisia verkkoja toisiinsa. Tällaisen reitittimen rakentamiseen tarvitaan vakaa alusta. Tällaisella alustalla luodaan mahdollisuus kuormittaa järjestelmää ilman suuria ongelmia. Tällainen alusta on Open Platform, joka on suunniteltu tällaisille toiminnoille ja yhdessä oikeanlaisen verkkoratkaisun kanssa sitä voidaan käyttää sille suunnitellussa ympäristössä. Tämän diplomityön tarkoituksena on arvioida neljää eri reititysohjelmistoa ja kahta eri IP pinoa. Työssä käytetyt testit on suunniteltu arviointia varten ja niiden tarkoituksena on tuoda esille ohjelmistoissa esiintyvät viat ja ongelmat. Kaikki testit ovat samoja kaikille ohjelmille ja tehdään samassa ympäristössä. Testit analysoidaan niiden ajon jälkeen ja niiden tulosten avulla tehdään päätös mitä näistä ohjelmistoista tullaan käyttämään seuraavan sukupolven avoimella alustalla, joka tulee toimimaan Nokian Intelligent Service Nodessa. Tämä verkon laite toimii yhdyskäytävänäerilaisten verkkojen välillä.