119 resultados para Reverse Power flows

em Doria (National Library of Finland DSpace Services) - National Library of Finland, Finland


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the Thesis main focus is done on power flow development paths around the Baltic States as well as on market-based requirements for creation of the common Baltic electricity market. Current market regulations between the countries are presented; barriers for creating competitive common Baltic power market and for electricity trading with third countries are clarified; solutions are offered and corresponding road map is developed. Future power development paths around the Baltic States are analysed. For this purpose the 330 kV transmission grid of Estonia, Latvia and Lithuania is modelled in a power flow tool. Power flow calculations are carried out for winter and summer peak and off-peak load periods in 2020 with different combinations of interconnections. While carrying out power balance experiments several power flow patterns in the Baltic States are revealed. Conclusions are made about security of supply, grid congestion and transmission capacity availability for different scenarios.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Tässä työssä simuloitiin Valkealassa sijaitsevaa Tirvan pienvesivoimalaitosta ja sen vaikutusta sähkönjakeluverkkoon. Pienvesivoimalaitos mallinnettiin PSCAD-ympäristöön verkko- ja voimalaitostietojen perusteella. Sähköverkko kuvattiin malliin koko 110 kV:n siirtävän verkon ja Tirvan pienjänniteverkon väliltä. Mallin avulla tehtiin sarja hajautettua sähköntuotantoa koskevia tarkasteluita. Tarkasteluissa huomattiin voimalaitoksen verkkoonliitynnän aiheuttavan standardien ylärajoilla olevan transienttisen muutoksen voimalaitoksen jännitteisiin. Työssä tehtiin yksityiskohtaisempi jännitehäviöiden mittaus voimalaitoksen pullonkaulana toimivalle pienitehoiselle jakelumuuntajalle. Tuotannon lisäämisen yhteydessä näkyvän yllättävän jännitteen laskun syyt paikannettiin muuntajalla tapahtuviin loistehon siirrosta johtuviin ylimääräisiin jännitehäviöihin. Voimalaitoksella ei ole merkittävää vaikutusta vikatilanteiden virtoihin.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Growing recognition of the electricity grid modernization to enable new electricity generation and consumption schemes has found articulation in the vision of the Smart Grid platform. The essence of this vision is an autonomous network with two-way electricity power flows and extensive real-time information between the generation nodes, various electricity-dependent appliances and all points in-between. Three major components of the Smart Grids are distributed intelligence, communication technologies, and automated control systems. The aim of this thesis is to recognize the challenges that Smart Grids are facing, while extinguishing the main driving factors for their introduction. The scope of the thesis also covers possible place of electricity Aggregator Company in the current and future electricity markets. Basic functions of an aggregator and possible revenue sources along with demand response feasibility calculations are reviewed within this thesis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This doctoral thesis introduces an improved control principle for active du/dt output filtering in variable-speed AC drives, together with performance comparisons with previous filtering methods. The effects of power semiconductor nonlinearities on the output filtering performance are investigated. The nonlinearities include the timing deviation and the voltage pulse waveform distortion in the variable-speed AC drive output bridge. Active du/dt output filtering (ADUDT) is a method to mitigate motor overvoltages in variable-speed AC drives with long motor cables. It is a quite recent addition to the du/dt reduction methods available. This thesis improves on the existing control method for the filter, and concentrates on the lowvoltage (below 1 kV AC) two-level voltage-source inverter implementation of the method. The ADUDT uses narrow voltage pulses having a duration in the order of a microsecond from an IGBT (insulated gate bipolar transistor) inverter to control the output voltage of a tuned LC filter circuit. The filter output voltage has thus increased slope transition times at the rising and falling edges, with an opportunity of no overshoot. The effect of the longer slope transition times is a reduction in the du/dt of the voltage fed to the motor cable. Lower du/dt values result in a reduction in the overvoltage effects on the motor terminals. Compared with traditional output filtering methods to accomplish this task, the active du/dt filtering provides lower inductance values and a smaller physical size of the filter itself. The filter circuit weight can also be reduced. However, the power semiconductor nonlinearities skew the filter control pulse pattern, resulting in control deviation. This deviation introduces unwanted overshoot and resonance in the filter. The controlmethod proposed in this thesis is able to directly compensate for the dead time-induced zero-current clamping (ZCC) effect in the pulse pattern. It gives more flexibility to the pattern structure, which could help in the timing deviation compensation design. Previous studies have shown that when a motor load current flows in the filter circuit and the inverter, the phase leg blanking times distort the voltage pulse sequence fed to the filter input. These blanking times are caused by excessively large dead time values between the IGBT control pulses. Moreover, the various switching timing distortions, present in realworld electronics when operating with a microsecond timescale, bring additional skew to the control. Left uncompensated, this results in distortion of the filter input voltage and a filter self-induced overvoltage in the form of an overshoot. This overshoot adds to the voltage appearing at the motor terminals, thus increasing the transient voltage amplitude at the motor. This doctoral thesis investigates the magnitude of such timing deviation effects. If the motor load current is left uncompensated in the control, the filter output voltage can overshoot up to double the input voltage amplitude. IGBT nonlinearities were observed to cause a smaller overshoot, in the order of 30%. This thesis introduces an improved ADUDT control method that is able to compensate for phase leg blanking times, giving flexibility to the pulse pattern structure and dead times. The control method is still sensitive to timing deviations, and their effect is investigated. A simple approach of using a fixed delay compensation value was tried in the test setup measurements. The ADUDT method with the new control algorithm was found to work in an actual motor drive application. Judging by the simulation results, with the delay compensation, the method should ultimately enable an output voltage performance and a du/dt reduction that are free from residual overshoot effects. The proposed control algorithm is not strictly required for successful ADUDT operation: It is possible to precalculate the pulse patterns by iteration and then for instance store them into a look-up table inside the control electronics. Rather, the newly developed control method is a mathematical tool for solving the ADUDT control pulses. It does not contain the timing deviation compensation (from the logic-level command to the phase leg output voltage), and as such is not able to remove the timing deviation effects that cause error and overshoot in the filter. When the timing deviation compensation has to be tuned-in in the control pattern, the precalculated iteration method could prove simpler and equally good (or even better) compared with the mathematical solution with a separate timing compensation module. One of the key findings in this thesis is the conclusion that the correctness of the pulse pattern structure, in the sense of ZCC and predicted pulse timings, cannot be separated from the timing deviations. The usefulness of the correctly calculated pattern is reduced by the voltage edge timing errors. The doctoral thesis provides an introductory background chapter on variable-speed AC drives and the problem of motor overvoltages and takes a look at traditional solutions for overvoltage mitigation. Previous results related to the active du/dt filtering are discussed. The basic operation principle and design of the filter have been studied previously. The effect of load current in the filter and the basic idea of compensation have been presented in the past. However, there was no direct way of including the dead time in the control (except for solving the pulse pattern manually by iteration), and the magnitude of nonlinearity effects had not been investigated. The enhanced control principle with the dead time handling capability and a case study of the test setup timing deviations are the main contributions of this doctoral thesis. The simulation and experimental setup results show that the proposed control method can be used in an actual drive. Loss measurements and a comparison of active du/dt output filtering with traditional output filtering methods are also presented in the work. Two different ADUDT filter designs are included, with ferrite core and air core inductors. Other filters included in the tests were a passive du/dtfilter and a passive sine filter. The loss measurements incorporated a silicon carbide diode-equipped IGBT module, and the results show lower losses with these new device technologies. The new control principle was measured in a 43 A load current motor drive system and was able to bring the filter output peak voltage from 980 V (the previous control principle) down to 680 V in a 540 V average DC link voltage variable-speed drive. A 200 m motor cable was used, and the filter losses for the active du/dt methods were 111W–126 W versus 184 W for the passive du/dt. In terms of inverter and filter losses, the active du/dt filtering method had a 1.82-fold increase in losses compared with an all-passive traditional du/dt output filter. The filter mass with the active du/dt method was 17% (2.4 kg, air-core inductors) compared with 14 kg of the passive du/dt method filter. Silicon carbide freewheeling diodes were found to reduce the inverter losses in the active du/dt filtering by 18% compared with the same IGBT module with silicon diodes. For a 200 m cable length, the average peak voltage at the motor terminals was 1050 V with no filter, 960 V for the all-passive du/dt filter, and 700 V for the active du/dt filtering applying the new control principle.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this thesis was to research how slurry’s viscosity and rheology affect to pumping in peristaltic hose pump and in eccentric progressive cavity pump. In addition, it was researched the formed pressure pulsation in hose pump. Pressure pulsation was studied by pumping different slurries and by using different pipe materials. Pressure and power curves were determined for both used pumps. It was also determined NPSHR curve for the progressive cavity pump. Literature part of the thesis considered to distribute fluids to different rheology types, as well as theories and models to identify different rheology types. Special attention was paid to non-Newtonian fluids, which were also used in experimental part of this thesis. In addition, the literature part discusses about pumps, parameters for pump sizing, and pressure pulsation in hose pump. Starch, bentonite, and carboxymethyl cellulose slurries were used in the experimental part of this thesis. The slurries were pumped with Flowrox peristaltic hose pump (LPP-T32) and eccentric progressive cavity pump (C10/10). From the each slurry was taken a sample, and the samples were analyzed for concentration, viscosity and rheology type. The used pipe materials in pressure pulsation experiments were steel and elastic, and it was also used a prototype of pulsation dampener. The pulsation experiments indicated that the elastic pipe and the prototype of pulsation dampener attenuated pressure pulsation better than the steel pipe at low pressure levels. The differences between different materials disappeared when pressure level and pump rotation speed increased. In slurry experiments, pulsation was different depending on rheology and viscosity of the slurry. According to experiments, the rheology did not significantly affect to pump power consumption or efficiency.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Solar and wind power produce electricity irregularly. This irregular power production is problematic and therefore production can exceed the need. Thus sufficient energy storage solutions are needed. Currently there are some storages, such as flywheel, but they are quite short-term. Power-to-Gas (P2G) offers a solution to store energy as a synthetic natural gas. It also improves nation’s energy self-sufficiency. Power-to-Gas can be integrated to an industrial or a municipal facility to reduce production costs. In this master’s thesis the integration of Power-to-Gas technologies to wastewater treatment as a part of the VTT’s Neo-Carbon Energy project is studied. Power-to-Gas produces synthetic methane (SNG) from water and carbon dioxide with electricity. This SNG can be considered as stored energy. Basic wastewater treatment technologies and the production of biogas in the treatment plant are studied. The utilisation of biogas and SNG in heat and power production and in transportation is also studied. The integration of the P2G to wastewater treatment plant (WWTP) is examined mainly from economic view. First the mass flows of flowing materials are calculated and after that the economic impact based on the mass flows. The economic efficiency is evaluated with Net Present Value method. In this thesis it is also studied the overall profitability of the integration and the key economic factors.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The steam turbines play a significant role in global power generation. Especially, research on low pressure (LP) steam turbine stages is of special importance for steam turbine man- ufactures, vendors, power plant owners and the scientific community due to their lower efficiency than the high pressure steam turbine stages. Because of condensation, the last stages of LP turbine experience irreversible thermodynamic losses, aerodynamic losses and erosion in turbine blades. Additionally, an LP steam turbine requires maintenance due to moisture generation, and therefore, it is also affecting on the turbine reliability. Therefore, the design of energy efficient LP steam turbines requires a comprehensive analysis of condensation phenomena and corresponding losses occurring in the steam tur- bine either by experiments or with numerical simulations. The aim of the present work is to apply computational fluid dynamics (CFD) to enhance the existing knowledge and understanding of condensing steam flows and loss mechanisms that occur due to the irre- versible heat and mass transfer during the condensation process in an LP steam turbine. Throughout this work, two commercial CFD codes were used to model non-equilibrium condensing steam flows. The Eulerian-Eulerian approach was utilised in which the mix- ture of vapour and liquid phases was solved by Reynolds-averaged Navier-Stokes equa- tions. The nucleation process was modelled with the classical nucleation theory, and two different droplet growth models were used to predict the droplet growth rate. The flow turbulence was solved by employing the standard k-ε and the shear stress transport k-ω turbulence models. Further, both models were modified and implemented in the CFD codes. The thermodynamic properties of vapour and liquid phases were evaluated with real gas models. In this thesis, various topics, namely the influence of real gas properties, turbulence mod- elling, unsteadiness and the blade trailing edge shape on wet-steam flows, are studied with different convergent-divergent nozzles, turbine stator cascade and 3D turbine stator-rotor stage. The simulated results of this study were evaluated and discussed together with the available experimental data in the literature. The grid independence study revealed that an adequate grid size is required to capture correct trends of condensation phenomena in LP turbine flows. The study shows that accurate real gas properties are important for the precise modelling of non-equilibrium condensing steam flows. The turbulence modelling revealed that the flow expansion and subsequently the rate of formation of liquid droplet nuclei and its growth process were affected by the turbulence modelling. The losses were rather sensitive to turbulence modelling as well. Based on the presented results, it could be observed that the correct computational prediction of wet-steam flows in the LP turbine requires the turbulence to be modelled accurately. The trailing edge shape of the LP turbine blades influenced the liquid droplet formulation, distribution and sizes, and loss generation. The study shows that the semicircular trailing edge shape predicted the smallest droplet sizes. The square trailing edge shape estimated greater losses. The analysis of steady and unsteady calculations of wet-steam flow exhibited that in unsteady simulations, the interaction of wakes in the rotor blade row affected the flow field. The flow unsteadiness influenced the nucleation and droplet growth processes due to the fluctuation in the Wilson point.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Artikkeli on alunperin julkaistu teoksessa: The informational city (1989) / Manuel Castells

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Line converters have become an attractive AC/DC power conversion solution in industrial applications. Line converters are based on controllable semiconductor switches, typically insulated gate bipolar transistors. Compared to the traditional diode bridge-based power converters line converters have many advantageous characteristics, including bidirectional power flow, controllable de-link voltage and power factor and sinusoidal line current. This thesis considers the control of the lineconverter and its application to power quality improving. The line converter control system studied is based on the virtual flux linkage orientation and the direct torque control (DTC) principle. A new DTC-based current control scheme is introduced and analyzed. The overmodulation characteristics of the DTC converter are considered and an analytical equation for the maximum modulation index is derived. The integration of the active filtering features to the line converter isconsidered. Three different active filtering methods are implemented. A frequency-domain method, which is based on selective harmonic sequence elimination, anda time-domain method, which is effective in a wider frequency band, are used inharmonic current compensation. Also, a voltage feedback active filtering method, which mitigates harmonic sequences of the grid voltage, is implemented. The frequency-domain and the voltage feedback active filtering control systems are analyzed and controllers are designed. The designs are verified with practical measurements. The performance and the characteristics of the implemented active filtering methods are compared and the effect of the L- and the LCL-type line filteris discussed. The importance of the correct grid impedance estimate in the voltage feedback active filter control system is discussed and a new measurement-based method to obtain it is proposed. Also, a power conditioning system (PCS) application of the line converter is considered. A new method for correcting the voltage unbalance of the PCS-fed island network is proposed and experimentally validated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Venäjällä uudistetaan sähkömarkkinoita. Uudistamisella pyritään vapauttamaan sähkömarkkinat ja lisäämään kilpailua energiasektorilla. Sähkömarkkinoiden vapauttamisen tarkoitus on energiasektorin hyötysuhteen nostaminen ja investointien houkutteleminen sektorille. Venäjä on ratifioinut Kioton protokollan, mikä energiasektorin kannalta on tärkeää, koska protokollan yhteistoteutusmekanismin kautta saadaan houkuteltua investointeja sektorille. Venäjän sähkömarkkinoiden vapauttamisen pitkäaikainen tähtäin on Venäjän ja Euroopan sähkömarkkinoiden integroituminen, joka tarkoittaa myös ympäristölainsäädännönyhtenäistämistä. Tämä tutkimus on osa Fortum Oyj:n tarjoamaa teknistä katselmusta Venäjällä toimivalle sähköyhtiölle, TGC-9:lle. Tässä työssä keskitytään TGC-9:n omistamien energiatuotantolaitoksien happamoitumista aiheuttaviin ilmapäästöihin ja pölypäästöihin. Tutkimuksessa pyritään myös löytämään Kioton protokollan yhteistoteutusmekanismi hyödyntämiskohteita. NOx -päästöt tulevat olemaan suurin haaste TGC-9:lle, jos ympäristöstandardit yhdenmukaistetaan. Yhteistoteutusmekanismin hyödyntämiskohteita löydettiin neljä: koksaamokaasun hyödyntäminen, maakaasun korvaaminen kuoren poltolla ja kaksi tapausta liittyen laitoksien hyötysuhteen nostamiseen.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Diplomityössä tutkittiin Loviisan voimalaitoksen primääri- ja sekundääripiirin aktiivisuusmittausten kykyä tunnistaa pienet primääri-sekundäärivuodot. Tarkasteltavat primääri-sekundäärivuotojen suuruudet valittiin laitoksen hätätilanne- ja häiriönselvitysohjeiden mukaisesti. Vuodon vaikutuksia arvioitiin erilaisilla primäärijäähdytteen ominaisaktiivisuuksilla. Ominaisaktiivisuudet primääripiirissä määritettiin nuklidikohtaisesti erilaisille polttoainevuototapauksille. Työssä huomioitiin myös transienteissa mahdollisesti esiintyvä primääripiirin aktiivisuustasoa nostava spiking-ilmiö. Vuodon tarkempaa tunnistamista varten työssä laskettiin tarkasteltaville mittareille kalibrointikertoimet. Primääri-sekundäärivuoto mallinnettiin APROS-simulointiohjelmalla laitoksen eri käyttötiloissa ja kahdella eri vuotokoolla. Varsinainen aktiivisuuslaskenta suoritettiin SEKUN-ohjelmalla. Työssä tätä aktiivisuus- ja päästölaskentaohjelmaa muokattiin ohjelmoimalla siihen tarkasteltavat aktiivisuusmittaukset sekä primääripiirin puhdistus ja ulospuhallus. Laskelmien tuloksena saatiin arviot kunkin tarkasteltavana olleen aktiivisuusmittauksen soveltuvuudesta primääri-sekundäärivuodon tunnistamiseen erilaisissa polttoainevuototapauksissa ja reaktorin eri tehotasoilla. Häiriönselvitysohje I3:n käyttöönottoa edellyttävät vuotokoot määritettiin aktiivisuusmittausten havaitseman perusteella. Erityisesti kuumavalmiustilassa tapauksissa, joissa reaktorisydämessä oletetaan olevan tiiveytensä menettäneitä polttoainesauvoja, spikingin vaikutus jäähdytteiden aktiivisuuspitoisuuksiin ja mittaustuloksiin oli merkittävä. Niiltä osin, kuin tulokset käsittelevät ohjeissa vuodon tunnistamiseen käytettyjä aktiivisuusrajoja, tulokset osoittivat aktiivisuusrajat oikeiksi. Kuumavalmiudessa aktiivisuusmittausten mittausalueet saattavat joissakin tapauksissa rajoittaa primääri-sekundäärivuodon tunnistamista.