8 resultados para Relative-rate Test

em Doria (National Library of Finland DSpace Services) - National Library of Finland, Finland


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Glass is a unique material with a long history. Several glass products are used daily in our everyday life, often unnoticed. Glass can be found not only in obvious applications such as tableware, windows, and light bulbs, but also in tennis rackets, windmill turbine blades, optical devices, and medical implants. The glasses used at present as implants are inorganic silica-based melt-derived compositions mainly for hard-tissue repair as bone graft substitute in dentistry and orthopedics. The degree of glass reactivity desired varies according to implantation situation and it is vital that the ion release from any glasses used in medical applications is controlled. Understanding the in vitro dissolution rate of glasses provides a first approximation of their behavior in vivo. Specific studies concerning dissolution properties of bioactive glasses have been relatively scarce and mostly concentrated to static condition studies. The motivation behind this work was to develop a simple and accurate method for quantifying the in vitro dissolution rate of highly different types of glass compositions with interest for future clinical applications. By combining information from various experimental conditions, a better knowledge of glass dissolution and the suitability of different glasses for different medical applications can be obtained. Thus, two traditional and one novel approach were utilized in this thesis to study glass dissolution. The chemical durability of silicate glasses was tested in water and TRIS-buffered solution at static and dynamic conditions. The traditional in vitro testing with a TRISbuffered solution under static conditions works well with bioactive or with readily dissolving glasses, and it is easy to follow the ion dissolution reactions. However, in the buffered solution no marked differences between the more durable glasses were observed. The hydrolytic resistance of the glasses was studied using the standard procedure ISO 719. The relative scale given by the standard failed to provide any relevant information when bioactive glasses were studied. However, the clear differences in the hydrolytic resistance values imply that the method could be used as a rapid test to get an overall idea of the biodegradability of glasses. The standard method combined with the ion concentration and pH measurements gives a better estimate of the hydrolytic resistance because of the high silicon amount released from a glass. A sensitive on-line analysis method utilizing inductively coupled plasma optical emission spectrometer and a flow-through micro-volume pH electrode was developed to study the initial dissolution of biocompatible glasses. This approach was found suitable for compositions within a large range of chemical durability. With this approach, the initial dissolution of all ions could be measured simultaneously and quantitatively, which gave a good overall idea of the initial dissolution rates for the individual ions and the dissolution mechanism. These types of results with glass dissolution were presented for the first time during the course of writing this thesis. Based on the initial dissolution patterns obtained with the novel approach using TRIS, the experimental glasses could be divided into four distinct categories. The initial dissolution patterns of glasses correlated well with the anticipated bioactivity. Moreover, the normalized surface-specific mass loss rates and the different in vivo models and the actual in vivo data correlated well. The results suggest that this type of approach can be used for prescreening the suitability of novel glass compositions for future clinical applications. Furthermore, the results shed light on the possible bioactivity of glasses. An additional goal in this thesis was to gain insight into the phase changes occurring during various heat treatments of glasses with three selected compositions. Engineering-type T-T-T curves for glasses 1-98 and 13-93 were stablished. The information gained is essential in manufacturing amorphous porous implants or for drawing of continuous fibers of the glasses. Although both glasses can be hot worked to amorphous products at carefully controlled conditions, 1-98 showed one magnitude greater nucleation and crystal growth rate than 13-93. Thus, 13-93 is better suited than 1-98 for working processes which require long residence times at high temperatures. It was also shown that amorphous and partially crystalline porous implants can be sintered from bioactive glass S53P4. Surface crystallization of S53P4, forming Na2O∙CaO∙2SiO2, was observed to start at 650°C. The secondary crystals of Na2Ca4(PO4)2SiO4, reported for the first time in this thesis, were detected at higher temperatures, from 850°C to 1000°C. The crystal phases formed affected the dissolution behavior of the implants in simulated body fluid. This study opens up new possibilities for using S53P4 to manufacture various structures, while tailoring their bioactivity by controlling the proportions of the different phases. The results obtained in this thesis give valuable additional information and tools to the state of the art for designing glasses with respect to future clinical applications. With the knowledge gained we can identify different dissolution patters and use this information to improve the tuning of glass compositions. In addition, the novel online analysis approach provides an excellent opportunity to further enhance our knowledge of glass behavior in simulated body conditions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this study, a model for the unsteady dynamic behaviour of a once-through counter flow boiler that uses an organic working fluid is presented. The boiler is a compact waste-heat boiler without a furnace and it has a preheater, a vaporiser and a superheater. The relative lengths of the boiler parts vary with the operating conditions since they are all parts of a single tube. The present research is a part of a study on the unsteady dynamics of an organic Rankine cycle power plant and it will be a part of a dynamic process model. The boiler model is presented using a selected example case that uses toluene as the process fluid and flue gas from natural gas combustion as the heat source. The dynamic behaviour of the boiler means transition from the steady initial state towards another steady state that corresponds to the changed process conditions. The solution method chosen was to find such a pressure of the process fluid that the mass of the process fluid in the boiler equals the mass calculated using the mass flows into and out of the boiler during a time step, using the finite difference method. A special method of fast calculation of the thermal properties has been used, because most of the calculation time is spent in calculating the fluid properties. The boiler was divided into elements. The values of the thermodynamic properties and mass flows were calculated in the nodes that connect the elements. Dynamic behaviour was limited to the process fluid and tube wall, and the heat source was regarded as to be steady. The elements that connect the preheater to thevaporiser and the vaporiser to the superheater were treated in a special way that takes into account a flexible change from one part to the other. The model consists of the calculation of the steady state initial distribution of the variables in the nodes, and the calculation of these nodal values in a dynamic state. The initial state of the boiler was received from a steady process model that isnot a part of the boiler model. The known boundary values that may vary during the dynamic calculation were the inlet temperature and mass flow rates of both the heat source and the process fluid. A brief examination of the oscillation around a steady state, the so-called Ledinegg instability, was done. This examination showed that the pressure drop in the boiler is a third degree polynomial of the mass flow rate, and the stability criterion is a second degree polynomial of the enthalpy change in the preheater. The numerical examination showed that oscillations did not exist in the example case. The dynamic boiler model was analysed for linear and step changes of the entering fluid temperatures and flow rates.The problem for verifying the correctness of the achieved results was that there was no possibility o compare them with measurements. This is why the only way was to determine whether the obtained results were intuitively reasonable and the results changed logically when the boundary conditions were changed. The numerical stability was checked in a test run in which there was no change in input values. The differences compared with the initial values were so small that the effects of numerical oscillations were negligible. The heat source side tests showed that the model gives results that are logical in the directions of the changes, and the order of magnitude of the timescale of changes is also as expected. The results of the tests on the process fluid side showed that the model gives reasonable results both on the temperature changes that cause small alterations in the process state and on mass flow rate changes causing very great alterations. The test runs showed that the dynamic model has no problems in calculating cases in which temperature of the entering heat source suddenly goes below that of the tube wall or the process fluid.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

High barrier materiaaleilla pyritään pidentämään pakattujen elintarvikkeiden hyllyikää. Barrierin tärkein tehtävä on elintarvikkeen suojaaminen hapelta ja kosteudelta. Alumiinin käyttöä barriermateriaalina pyritään vähentämään korvaamalla alumiini polymeereillä, jotka täyttävät elintarvikkeiden asettamat korkeat säilyvyysvaatimukset. Etyylivinyylialkoholin (EVOH) hapenläpäisevyys on kuivissa olosuhteissa alhaisin kaupallisista muovilaaduista. EVOH tarjoaa myös erinomaisen suojan muita kaasuja, rasvoja, hajuja ja aromeja vastaan ja sitä on helppo prosessoida. Polyamideilla on erinomainen kaasutiiveys sekä hyvä lujuus ja sitkeys. Eri muovilaatuja sekoittamalla voidaan vähentää hapenläpäisyä ja parantaa prosessointia. Polyolefiineja käytetään yleisesti päällystysmateriaaleina, koska ne suojaavat tuotetta erinomaisesti kosteudelta. Hapenläpäisyllä tarkoitetaan hapen kulkeutumista materiaalin läpi joko permeaation kautta tai reikien ja vuotojen läpi. Kaasun permeoitumiseen materiaalin läpi vaikuttavat materiaalin vapaa tilavuus, kiteisyysaste, orientaatio, substituointi, suhteellinen kosteus, lämpötila, barrierkerroksen paksuus, paine-ero ja permeoituvan molekyylin ominaisuudet. Kokeellisessa osassa analysoitiin ja vertailtiin kartonkipohjaisia mehutölkkejä, joissa käytettävät high barrier materiaalit olivat EVOH ja PA. Kartonkipohjaisia alumiinitölkkejä käytettiin referenssinä. Pakkausten hapenläpäisevyysmittauksissa saatiin samasta näytteestä toistettavia tuloksia, vaikka vuotomittauksissa saadut tulokset eivät olleet vertailukelpoisia hapenläpäisytulosten kanssa. Tölkkien valmistus vaikutti oleellisesti pakkausten tiiveysominaisuuksiin. Hapenläpäisy vuotojen ja reikien läpi oli merkittävämpää kuin hapenläpäisy materiaalin läpi. Pakkausten tiiveysominaisuuksia analysoitiin mittaamalla appelsiinimehun askorbiini-happopitoisuus. Askorbiinihapon hajoaminen mitattiin koetölkkeihin pakatusta appelsiinimehusta, ja lämpötilan, valon ja hapen vaikutusta askorbiinihapon hajoamiseen tutkittiin 12 viikon ajan. Lämpötilalla oli suurin vaikutus askorbiinihapon hajoamiseen huolimatta käytetystä pakkausmateriaalista.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

One of the primary goals for food packages is to protect food against harmful environment, especially oxygen and moisture. The gas transmission rate is the total gas transport through the package, both by permeation through the package material and by leakage through pinholes and cracks. The shelf life of a product can be extended, if the food is stored in a gas tight package. Thus there is a need to test gas tightness of packages. There are several tightness testing methods, and they can be broadly divided into destructive and nondestructive methods. One of the most sensitive methods to detect leaks is by using a non destructive tracer gas technique. Carbon dioxide, helium and hydrogen are the most commonly used tracer gases. Hydrogen is the lightest and the smallest of all gases, which allows it to escape rapidly from the leak areas. The low background concentration of H2 in air (0.5 ppm) enables sensitive leak detection. With a hydrogen leak detector it is also possible to locate leaks. That is not possible with many other tightness testing methods. The experimental work has been focused on investigating the factors which affect the measurement results with the H2leak detector. Also reasons for false results were searched to avoid them in upcoming measurements. From the results of these experiments, the appropriate measurement practice was created in order to have correct and repeatable results. The most important thing for good measurement results is to keep the probe of the detector tightly against the leak. Because of its high diffusion rate, the HZ concentration decreases quickly if holding the probe further away from the leak area and thus the measured H2 leaks would be incorrect and small leaks could be undetected. In the experimental part hydrogen, oxygen and water vapour transmissions through laser beam reference holes (diameters 1 100 μm) were also measured and compared. With the H2 leak detector it was possible to detect even a leakage through 1 μm (diameter) within a few seconds. Water vapour did not penetrate even the largest reference hole (100 μm), even at tropical conditions (38 °C, 90 % RH), whereas some O2 transmission occurred through the reference holes larger than 5 μm. Thus water vapour transmission does not have a significant effect on food deterioration, if the diameter of the leak is less than 100 μm, but small leaks (5 100 μm) are more harmful for the food products, which are sensitive to oxidation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

APROS (Advanced Process Simulation Environment) is a computer simulation program developed to simulate thermal hydraulic processes in nuclear and conventional power plants. Earlier research at VTT Technological Research Centre of Finland had found the current version of APROS to produce inaccurate simulation results for a certain case of loop seal clearing. The objective of this Master’s thesis is to find and implement an alternative method for calculating the rate of stratification in APROS, which was found to be the reason for the inaccuracies. Brief literature study was performed and a promising candidate for the new method was found. The new method was implemented into APROS and tested against experiments and simulations from two test facilities and the current version of APROS. Simulation results with the new version were partially conflicting; in some cases the new method was more accurate than the current version, in some the current method was better. Overall, the new method can be assessed as an improvement.