51 resultados para RADIATION SOURCE IMPLANTS

em Doria (National Library of Finland DSpace Services) - National Library of Finland, Finland


Relevância:

80.00% 80.00%

Publicador:

Resumo:

The purpose of gamma spectrometry and gamma and X-ray tomography of nuclear fuel is to determine both radionuclide concentration and integrity and deformation of nuclear fuel. The aims of this thesis have been to find out the basics of gamma spectrometry and tomography of nuclear fuel, to find out the operational mechanisms of gamma spectrometry and tomography equipment of nuclear fuel, and to identify problems that relate to these measurement techniques. In gamma spectrometry of nuclear fuel the gamma-ray flux emitted from unstable isotopes is measured using high-resolution gamma-ray spectroscopy. The production of unstable isotopes correlates with various physical fuel parameters. In gamma emission tomography the gamma-ray spectrum of irradiated nuclear fuel is recorded for several projections. In X-ray transmission tomography of nuclear fuel a radiation source emits a beam and the intensity, attenuated by the nuclear fuel, is registered by the detectors placed opposite. When gamma emission or X-ray transmission measurements are combined with tomographic image reconstruction methods, it is possible to create sectional images of the interior of nuclear fuel. MODHERATO is a computer code that simulates the operation of radioscopic or tomographic devices and it is used to predict and optimise the performance of imaging systems. Related to the X-ray tomography, MODHERATO simulations have been performed by the author. Gamma spectrometry and gamma and X-ray tomography are promising non-destructive examination methods for understanding fuel behaviour under normal, transient and accident conditions.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Tässä työssä on tutkittu OL1/OL2-ydinvoimalaitosten käytetyn polttoaineen siirrossa aiheutuvaa altistusta neutronisäteilylle. Käytetty polttoaine siirretään vedellä täytetyssä käytetyn polttoaineen siirtosäiliössä Castor TVO:ssa OL1/OL2-laitoksilta käytetyn polttoaineen varastolle. Siirtotyön aikana useat eri ammattiryhmiin kuuluvat henkilöt työskentelevät siirtosäiliön välittömässä läheisyydessä, altistuen käytetystä polttoaineesta emittoituvalle fotoni- ja neutronisäteilylle. Aikaisemmista neutronisäteilyannosten mittauksista on todettu, ettei jatkuvalle altistuksen seurannalle ole ollut tarvetta. Tämän työn tarkoitus on selvittää teoreettisilla laskelmilla siirtotyöhön osallistuvan henkilön mahdollisuus saada kirjausrajan ylittävä annos neutronisäteilyä. Neutronisäteilyn annosnopeudet siirtosäiliötä ympäröivässä tilassa on laskettu yhdysvaltalaisella Monte Carlo-menetelmään perustuvalla MCNP-ohjelmalla. MCNP:llä mallinnettiin siirtosäiliö, siirtosäiliön sisältämä polttoaine ja ympäröivä tila kolmella jäähtymisajalla ja kolmella keskimääräisellä maksimipoistopalamalla. Polttoainenippujen isotooppikonsentraatiot ja säteilylähteiden voimakkuudet on laskettu Studsvik SNF-ohjelmalla. Simuloinnin perusteella voidaan todeta, ettei neutronisäteilyannosten jatkuvalle seurannalle ole tarvetta käytetyn polttoaineen siirrossa. Vaikka neutronisäteilyn annosnopeudet voivat nousta siirtosäiliön läheisyydessä suhteellisen suuriksi, ovat siirtosäiliön lähellä tehtävät työt niin lyhytaikaisia, että kirjausrajan ylitystä voidaan pitää hyvin epätodennäköisenä. Johtopäätökset varmistetaan työssä suunnitellulla mittausjärjestelyllä.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Selostus : Kilpailukykyinen menetelmä pistemäisten fosforikuormitusalueiden paikantamiseen

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Line converters have become an attractive AC/DC power conversion solution in industrial applications. Line converters are based on controllable semiconductor switches, typically insulated gate bipolar transistors. Compared to the traditional diode bridge-based power converters line converters have many advantageous characteristics, including bidirectional power flow, controllable de-link voltage and power factor and sinusoidal line current. This thesis considers the control of the lineconverter and its application to power quality improving. The line converter control system studied is based on the virtual flux linkage orientation and the direct torque control (DTC) principle. A new DTC-based current control scheme is introduced and analyzed. The overmodulation characteristics of the DTC converter are considered and an analytical equation for the maximum modulation index is derived. The integration of the active filtering features to the line converter isconsidered. Three different active filtering methods are implemented. A frequency-domain method, which is based on selective harmonic sequence elimination, anda time-domain method, which is effective in a wider frequency band, are used inharmonic current compensation. Also, a voltage feedback active filtering method, which mitigates harmonic sequences of the grid voltage, is implemented. The frequency-domain and the voltage feedback active filtering control systems are analyzed and controllers are designed. The designs are verified with practical measurements. The performance and the characteristics of the implemented active filtering methods are compared and the effect of the L- and the LCL-type line filteris discussed. The importance of the correct grid impedance estimate in the voltage feedback active filter control system is discussed and a new measurement-based method to obtain it is proposed. Also, a power conditioning system (PCS) application of the line converter is considered. A new method for correcting the voltage unbalance of the PCS-fed island network is proposed and experimentally validated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pulsewidth-modulated (PWM) rectifier technology is increasingly used in industrial applications like variable-speed motor drives, since it offers several desired features such as sinusoidal input currents, controllable power factor, bidirectional power flow and high quality DC output voltage. To achieve these features,however, an effective control system with fast and accurate current and DC voltage responses is required. From various control strategies proposed to meet these control objectives, in most cases the commonly known principle of the synchronous-frame current vector control along with some space-vector PWM scheme have been applied. Recently, however, new control approaches analogous to the well-established direct torque control (DTC) method for electrical machines have also emerged to implement a high-performance PWM rectifier. In this thesis the concepts of classical synchronous-frame current control and DTC-based PWM rectifier control are combined and a new converter-flux-based current control (CFCC) scheme is introduced. To achieve sufficient dynamic performance and to ensure a stable operation, the proposed control system is thoroughly analysed and simple rules for the controller design are suggested. Special attention is paid to the estimationof the converter flux, which is the key element of converter-flux-based control. Discrete-time implementation is also discussed. Line-voltage-sensorless reactive reactive power control methods for the L- and LCL-type line filters are presented. For the L-filter an open-loop control law for the d-axis current referenceis proposed. In the case of the LCL-filter the combined open-loop control and feedback control is proposed. The influence of the erroneous filter parameter estimates on the accuracy of the developed control schemes is also discussed. A newzero vector selection rule for suppressing the zero-sequence current in parallel-connected PWM rectifiers is proposed. With this method a truly standalone and independent control of the converter units is allowed and traditional transformer isolation and synchronised-control-based solutions are avoided. The implementation requires only one additional current sensor. The proposed schemes are evaluated by the simulations and laboratory experiments. A satisfactory performance and good agreement between the theory and practice are demonstrated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The diffusion of mobile telephony began in 1971 in Finland, when the first car phones, called ARP1 were taken to use. Technologies changed from ARP to NMT and later to GSM. The main application of the technology, however, was voice transfer. The birth of the Internet created an open public data network and easy access to other types of computer-based services over networks. Telephones had been used as modems, but the development of the cellular technologies enabled automatic access from mobile phones to Internet. Also other wireless technologies, for instance Wireless LANs, were also introduced. Telephony had developed from analog to digital in fixed networks and allowed easy integration of fixed and mobile networks. This development opened a completely new functionality to computers and mobile phones. It also initiated the merger of the information technology (IT) and telecommunication (TC) industries. Despite the arising opportunity for firms' new competition the applications based on the new functionality were rare. Furthermore, technology development combined with innovation can be disruptive to industries. This research focuses on the new technology's impact on competition in the ICT industry through understanding the strategic needs and alternative futures of the industry's customers. The change speed inthe ICT industry is high and therefore it was valuable to integrate the DynamicCapability view of the firm in this research. Dynamic capabilities are an application of the Resource-Based View (RBV) of the firm. As is stated in the literature, strategic positioning complements RBV. This theoretical framework leads theresearch to focus on three areas: customer strategic innovation and business model development, external future analysis, and process development combining these two. The theoretical contribution of the research is in the development of methodology integrating theories of the RBV, dynamic capabilities and strategic positioning. The research approach has been constructive due to the actual managerial problems initiating the study. The requirement for iterative and innovative progress in the research supported the chosen research approach. The study applies known methods in product development, for instance, innovation process in theGroup Decision Support Systems (GDSS) laboratory and Quality Function Deployment (QFD), and combines them with known strategy analysis tools like industry analysis and scenario method. As the main result, the thesis presents the strategic innovation process, where new business concepts are used to describe the alternative resource configurations and scenarios as alternative competitive environments, which can be a new way for firms to achieve competitive advantage in high-velocity markets. In addition to the strategic innovation process as a result, thestudy has also resulted in approximately 250 new innovations for the participating firms, reduced technology uncertainty and helped strategic infrastructural decisions in the firms, and produced a knowledge-bank including data from 43 ICT and 19 paper industry firms between the years 1999 - 2004. The methods presentedin this research are also applicable to other industries.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

IIn electric drives, frequency converters are used to generatefor the electric motor the AC voltage with variable frequency and amplitude. When considering the annual sale of drives in values of money and units sold, the use of low-performance drives appears to be in predominant. These drives have tobe very cost effective to manufacture and use, while they are also expected to fulfill the harmonic distortion standards. One of the objectives has also been to extend the lifetime of the frequency converter. In a traditional frequency converter, a relatively large electrolytic DC-link capacitor is used. Electrolytic capacitors are large, heavy and rather expensive components. In many cases, the lifetime of the electrolytic capacitor is the main factor limiting the lifetime of the frequency converter. To overcome the problem, the electrolytic capacitor is replaced with a metallized polypropylene film capacitor (MPPF). The MPPF has improved properties when compared to the electrolytic capacitor. By replacing the electrolytic capacitor with a film capacitor the energy storage of the DC-linkwill be decreased. Thus, the instantaneous power supplied to the motor correlates with the instantaneous power taken from the network. This yields a continuousDC-link current fed by the diode rectifier bridge. As a consequence, the line current harmonics clearly decrease. Because of the decreased energy storage, the DC-link voltage fluctuates. This sets additional conditions to the controllers of the frequency converter to compensate the fluctuation from the supplied motor phase voltages. In this work three-phase and single-phase frequency converters with small DC-link capacitor are analyzed. The evaluation is obtained with simulations and laboratory measurements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis describes the development of advanced silicon radiation detectors and their characterization by simulations, used in the work for searching elementary particles in the European Organization for Nuclear Research, CERN. Silicon particle detectors will face extremely harsh radiation in the proposed upgrade of the Large Hadron Collider, the future high-energy physics experiment Super-LHC. The increase in the maximal fluence and the beam luminosity up to 1016 neq / cm2 and 1035 cm-2s-1 will require detectors with a dramatic improvement in radiation hardness, when such a fluence will be far beyond the operational limits of the present silicon detectors. The main goals of detector development concentrate on minimizing the radiation degradation. This study contributes mainly to the device engineering technology for developing more radiation hard particle detectors with better characteristics. Also the defect engineering technology is discussed. In the nearest region of the beam in Super-LHC, the only detector choice is 3D detectors, or alternatively replacing other types of detectors every two years. The interest in the 3D silicon detectors is continuously growing because of their many advantages as compared to conventional planar detectors: the devices can be fully depleted at low bias voltages, the speed of the charge collection is high, and the collection distances are about one order of magnitude less than those of planar technology strip and pixel detectors with electrodes limited to the detector surface. Also the 3D detectors exhibit high radiation tolerance, and thus the ability of the silicon detectors to operate after irradiation is increased. Two parameters, full depletion voltage and electric field distribution, is discussed in more detail in this study. The full depletion of the detector is important because the only depleted area in the detector is active for the particle tracking. Similarly, the high electric field in the detector makes the detector volume sensitive, while low-field areas are non-sensitive to particles. This study shows the simulation results of full depletion voltage and the electric field distribution for the various types of 3D detectors. First, the 3D detector with the n-type substrate and partial-penetrating p-type electrodes are researched. A detector of this type has a low electric field on the pixel side and it suffers from type inversion. Next, the substrate is changed to p-type and the detectors having electrodes with one doping type and the dual doping type are examined. The electric field profile in a dual-column 3D Si detector is more uniform than that in the single-type column 3D detector. The dual-column detectors are the best in radiation hardness because of their low depletion voltages and short drift distances.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Selostus: Perunaruton munaitiöt maassa ovat uusi merkittävä epidemian alkulähde Suomessa

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Työn tavoitteena oli selvittää organisaation ostopäätösprosessi, kun tuotteina ovat biohajoavat kasvo- ja kallokirurgian implantit. Ensin selvitettiin biohajoavien implanttien markkinapotentiaalia, biohajoavien materiaalien lisäksi implanttien valmistuksessa käytettäviä muita materiaaleja sekä implanteilta vaadittavia ominaisuuksia kirjallisuuden ja internetin sekä asiantuntijahaastatteluiden avulla. Kirjallisuuden avulla selvitettiin myös organisaatioiden ostopäätösprosessien yleisiä piirteitä ja vaiheita. Biohajoavien kasvo- ja kallokirurgian implanttien ostopäätösprosessia tutkittiin kirjallisen kyselytutkimuksen avulla, joka oli suunnattu alan asiantuntijoille Euroopassa, Yhdysvalloissa sekä Kanadassa. Tutkimuksessa selvitettiin mm. tärkeimpiä käytettävien implanttien materiaalivalintaan vaikuttavia kriteereitä, ostopäätösprosessiin osallistuvia organisaation jäseniä, sekä heidän roolejaan päätöksenteossa, implantteja koskevan informaation etsintää sekä ostopäätösprosessin vaiheita. Kirjallisuudesta, internetistä, asiantuntijahaastatteluista ja kyselytutkimuksesta saatu tieto koottiin vuokaaviomalliksi, joka kuvaa kasvo- ja kallokirurgian implanttien ostopäätösprosessia organisaatioissa. Lopuksi esitettiin myös ehdotuksia markkinointisuunnitelmaan sekä jatkotutkimusehdotukset.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tässä diplomityössä kuvataan Loviisan voimalaitoksen vaihtelevien kontaminaation nuklidijakaumien vaikutusta kontaminaatiomittausten tuloksiin. Nuklidikohtaisten tietojen ja kontaminaation nuklidikoostumuksen selvittämiseen käytettiin epäsuoraa kontaminaationmittausmenetelmää. Valvonta-alueen eri huonetiloista kerättiin pyyhintänäytteitä. Näytteet mitattiin kontaminaatiomittareilla sekä gammaspektrometrisesti radiokemian laboratoriossa. Gamma-analyysissä saatiin selville nuklidikohtaiset aktiivisuudet ja suhteelliset nuklidijakaumat. Kirjallisuudesta etsittiin tiedot kunkin kontaminaatiosta löytyneen nuklidin aktiivisuusominaisuuksille. Säteilyn ilmaisimien havaitsemistehokkuuden energiariippuvuus vaikuttaa kunkin nuklidin mittaustulokseen. Nuklidikohtaisten tietojen sekä tunnettujen energiariippuvuuksien perusteella arvioitiin hiukkasten energiajakauman aiheuttaman mittausvirheen osuutta kullekin nuklidijakaumalle. Tässä tutkimuksessa tarkastellaan lisäksi eri kontaminaatiomittausmenetelmien hyviä ja huonoja puolia. Säteilysuojelutyössä käytetyt kontaminaation mittalaitteet on työssä esitelty ja mittaustarkkuuteen vaikuttavia seikkoja on käsitelty operatiivisen säteilysuojelun kannalta.