8 resultados para RADIATION INJURIES

em Doria (National Library of Finland DSpace Services) - National Library of Finland, Finland


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis describes the development of advanced silicon radiation detectors and their characterization by simulations, used in the work for searching elementary particles in the European Organization for Nuclear Research, CERN. Silicon particle detectors will face extremely harsh radiation in the proposed upgrade of the Large Hadron Collider, the future high-energy physics experiment Super-LHC. The increase in the maximal fluence and the beam luminosity up to 1016 neq / cm2 and 1035 cm-2s-1 will require detectors with a dramatic improvement in radiation hardness, when such a fluence will be far beyond the operational limits of the present silicon detectors. The main goals of detector development concentrate on minimizing the radiation degradation. This study contributes mainly to the device engineering technology for developing more radiation hard particle detectors with better characteristics. Also the defect engineering technology is discussed. In the nearest region of the beam in Super-LHC, the only detector choice is 3D detectors, or alternatively replacing other types of detectors every two years. The interest in the 3D silicon detectors is continuously growing because of their many advantages as compared to conventional planar detectors: the devices can be fully depleted at low bias voltages, the speed of the charge collection is high, and the collection distances are about one order of magnitude less than those of planar technology strip and pixel detectors with electrodes limited to the detector surface. Also the 3D detectors exhibit high radiation tolerance, and thus the ability of the silicon detectors to operate after irradiation is increased. Two parameters, full depletion voltage and electric field distribution, is discussed in more detail in this study. The full depletion of the detector is important because the only depleted area in the detector is active for the particle tracking. Similarly, the high electric field in the detector makes the detector volume sensitive, while low-field areas are non-sensitive to particles. This study shows the simulation results of full depletion voltage and the electric field distribution for the various types of 3D detectors. First, the 3D detector with the n-type substrate and partial-penetrating p-type electrodes are researched. A detector of this type has a low electric field on the pixel side and it suffers from type inversion. Next, the substrate is changed to p-type and the detectors having electrodes with one doping type and the dual doping type are examined. The electric field profile in a dual-column 3D Si detector is more uniform than that in the single-type column 3D detector. The dual-column detectors are the best in radiation hardness because of their low depletion voltages and short drift distances.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hamstring muscle injuries and tendon disorders are common, especially in sports. They can be severe and difficult to treat, often resulting in impaired athletic performance and long rehabilitation times. Previous studies considering treatment of these problems are scarce. The current study was designed to investigate the effect of surgery on different types of hamstring muscle injuries and on proximal hamstring tendinopathy. In addition, we wanted to study the typical histopathological findings relating to proximal hamstring tendinopathy. In the study of complete (all three muscles torn) proximal hamstring avulsions (41 patients), our results showed that early operative treatment gives significantly better results than late surgery, and is therefore recommended. Despite this, considerable improvement of symptoms could also be achieved in chronic cases. In the study of partial (one or two muscles torn) proximal hamstring tears (47 patients), we observed that these injuries can cause significant functional deficit and impaired performance in athletes. The main finding was that after surgical repair most of the patients were able to return to their pre-injury level of sports. In the study of distal hamstring tears (18 patients), the results showed that surgical treatment had a good effect in the majority of these cases. In proximal hamstring tendinopathy, the main problem is pain which limits sports. In this study (90 patients), we found that after unsuccessful conservative treatment, surgery was a good treatment option resulting in full return to sports in most cases. In tendinopathic hamstring tendons, the morphological changes of tendinosis were largely identical to those previously described in other common (e.g. Achilles and patellar) tendinopathies. In chronic proximal hamstring avulsions, and also in reoperations, a large defect between distally retracted tendons and the ischial tuberosity may occasionally prevent anatomic reinsertion. We have described a reconstruction method using fascia lata autograft augmentation to be used in these most challenging repairs. This technique was utilized in the treatment of five patients, with encouraging results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Planar, large area, position sensitive silicon detectors are widely utilized in high energy physics research and in medical, computed tomography (CT). This thesis describes author's research work relating to development of such detector components. The key motivation and objective for the research work has been the development of novel, position sensitive detectors improving the performance of the instruments they are intended for. Silicon strip detectors are the key components of barrel-shaped tracking instruments which are typically the innermost structures of high energy physics experimental stations. Particle colliders such as the former LEP collider or present LHC produce particle collisions and the silicon strip detector based trackers locate the trajectories of particles emanating from such collisions. Medical CT has become a regular part of everyday medical care in all developed countries. CT scanning enables x-ray imaging of all parts of the human body with an outstanding structural resolution and contrast. Brain, chest and abdomen slice images with a resolution of 0.5 mm are possible and latest CT machines are able to image whole human heart between heart beats. The two application areas are presented shortly and the radiation detection properties of planar silicon detectors are discussed. Fabrication methods and preamplifier electronics of the planar detectors are presented. Designs of the developed, large area silicon detectors are presented and measurement results of the key operating parameters are discussed. Static and dynamic performance of the developed silicon strip detectors are shown to be very satisfactory for experimental physics applications. Results relating to the developed, novel CT detector chips are found to be very promising for further development and all key performance goals are met.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dental injuries are common and the incidence of maxillofacial injuries has increased over the recent decades in Finland. Accidental injuries are the global leading cause of death among children over the age of one year and among adults under the age of 40 globally. Significant resources and costs are needed for the treatment of these patients. The prevention is the most economical way to reduce trauma rates and costs. For the prevention it is crucial to know the prevalences, incidences and risk factors related to injuries. To improve the quality of treatment, it is essential to explore the causes, trauma mechanisms and management of trauma. The above mentioned was the aim of this thesis. With a large epidemiological cohort study (5737 participants) it was possible to estimate lifetime prevalence of and risk factors for dental trauma in general population (Study I). The prevalence of dental fractures was 43% and the prevalence of dental luxations and avulsions was 14%. Male gender, a history of previous non-dental injuries, mental distress, overweight and high alcohol consumption were positively associated with the occurrence of dental injuries Study II was conducted to explore the differences in type and multiplicity of mandibular fractures in three different countries (Canada, Finland and Kuwait). This retrospective study showed that the differences in mandibular fracture multiplicity and location are based on different etiologies and demographic patterns. This data can be exploited for planning of measures to prevent traumatic facial fractures. The etiology, management and outcome of 63 pediatric skull base fracture (Study III) and 20 pediatric frontobasal fracture patients (Study IV) were explored. These retrospective studies showed that, both skull base fracture and frontobasa fracture are rare injuries in childhood and although intracranial injuries and morbidity are frequent, permanent neurological or neuropsychological deficits are infrequent. A systematic algorithm (Study V) for computer tomography (CT) image review was aimed at clinicians and radiologists to improve the assessment of patients with complex upper midface and cranial base trauma. The cohort study was cross sectional and data was collected in the Turku and Oulu University Hospitals. A novel image-reviewing algorithm was created to enhance the specificity of CT for the diagnosis of frontobasal fractures. The study showed that an image-viewing algorithm standardizes the frontobasal trauma detection procedure and leads to better control and assessment. The purpose of the retrospective subcranial craniotomy study (VI) was to review the types of frontobasal fractures and their management, complications and outcome when the fracture is approached subcranially. The subcranial approach appears to be successful and have a reasonably low complication rate. It may be recommended as the technique of choice in multiple and the most complicated frontal base fractures where the endoscopic endonasal approach is not feasible.