5 resultados para QC 20 (denture base resin)
em Doria (National Library of Finland DSpace Services) - National Library of Finland, Finland
Resumo:
Polymeric materials have been used in dental applications for decades. Adhesion of polymeric materials to each other and to the tooth substrate is essential to their successful use. The aim of this series of studies was two-folded. First, to improve adhesion of poly(paraphenylene) based rigid rod polymer (RRP) to other dental polymers, and secondly, to evaluate the usability of a new dentin primer system based on RRP fillers. Poly(paraphenylene) based RRP would be a tempting material for dental applications because of its good mechanical properties. To be used in dental applications, reliable adhesion between RRP and other dental polymers is required. In this series of studies, the adhesion of RRP to denture base polymer and the mechanical properties of RRP-denture base polymer-material combination were evaluated. Also adhesion of BisGMA-TEGDMA-resin to RRP was determined. Different surface treatments were tested to improve the adhesion of BisGMA-TEGDMA-resin to RRP. Results were based on three-point bending testing, Vickers surface hardness test and scanning electron microscope analysis (SEM), which showed that no reliable adhesion between RRP and denture base polymer was formed. Addition of RRP filler to denture base polymer increased surface hardness and flexural modulus but flexural strength decreased. Results from the shear bond strength test and SEM revealed that adhesion between resin and RRP was possible to improve by surface treatment with dichloromethane (DCM) based primer and a new kind of adhesive surface can be designed. The current dentin bonding agents have good immediate bond strength, but in long term the bond strength may decrease due to the detrimental effect of water and perhaps by matrix metalloproteinases. This leads to problems in longevity of restorations. Current bonding agents use organic monomers. In this series of studies, RRP filled dentin primer was tested in order to decrease the water sorption of the monomer system of the primers. The properties of new dentin primer system were evaluated in vitro by comparing it to commercial etch and rinse adhesive system. The results from the contact angle measurements and SEM showed that experimental primer with RRP reinforcement provided similar resin infiltration to dentin collagen and formed the resin-dentin interface as the control primer. Microtensile bond strength test and SEM revealed that in short term water storing, RRP increased bond strength and primer with BMEP-monomer (bis[2-(methacryloyloxy)-ethyl]phosphate) and high solvent concentration provided comparable bonding properties to the commercial control primers. In long term water storing, the high solvent-monomer concentration of the experimental primers decreased bond strength. However, in low solvent-monomer concentration groups, the long-term water storing did not decrease the bond strength despite the existence of hydrophilic monomers which were used in the system. These studies demonstrated that new dentin primer system reached the mechanical properties of current traditional etch and rinse adhesive system in short time water storing. Improved properties can be achieved by further modifications of the monomer system. Studies of the adhesion of RRP to other polymers suggest that adhesion between RRP and other dental polymers is possible to obtain by certain surface treatments.
Resumo:
Työssä tutkittiin laboratorio-olosuhteissa germaniumin talteenottoa happamista hydrometallurgisista sulfaattiliuoksista käyttäen kaupallisia ioninvaihtohartseja. Germaniumin talteenottoa tutkittiin sekä tasapaino- että kolonnikokein syöttöliuoksista joiden pH oli alueella 0,8–3,0. Tutkituista hartseista parhaiten germanium voitiin erottaa käyttäen emäsmuotoista N-metyyli-D-glukamiini-tyyppistä ioninvaihtohartsia (esim. Rohm & Haasin IRA-743). Germaniumille määritettiin adsorptioisotermit tasapainokokein sekä emäs- että happomuotoisilla hartseilla. Adsorptioisotermien perusteella parhaiten germa-niumia adsorboi emäsmuotoinen IRA-743-hartsi kun liuoksen alku-pH oli tutkitun alueen korkein. Lämpötilassa 25 °C kapasiteetti oli 114 mg Ge/g. Tasapainokokein määritettiin emäsmuotoisilla hartseilla germaniumin lisäksi myös kuparia ja kobolttia sisältävillä liuoksilla Ge:n jakaantumisvakiot sekä erotustekijät Ge/Cu ja Ge/Co. Havaittiin, että IRA-743:lla alku-pH:ssa 3,0 Ge:n jakaantumisvakiot sekä erotustekijät Ge/Cu ja Ge/Co olivat selvästi suuremmat kuin muilla tutkituilla hartseilla. Arseenin, nikkelin, sinkin ja rauta(III):n adsorboitumista emäsmuotoiseen IRA-743:een tutkittiin monimetallisella liuoksella syöttöliuoksen pH:n ollessa alueella 1,4–3,6. Kokeissa havaittiin, että hartsi adsorboi hieman Ni:a ja Zn:a tasapaino-pH:n ollessa yli 5,5. Arseenia ei tutkitulla pH-alueella havaittu adsorboituvan. Lisäksi huomattiin, että rauta alkaa saostua pH:n ollessa hieman alle kolme. Kolonnikokeissa havaittiin, että emäsmuotoinen IRA-743-hartsi toimii hyvin germaniumin talteenotossa myös kolonnissa. Pelkästään germaniumia ja kobolttia sisältäneellä liuoksella hartsin dynaamiseksi kapasiteetiksi saatiin 54 mg Ge/g. Germaniumin eluointi IRA-743:sta onnistui parhaiten 0,5 M H2SO4:lla. Kolonnikokeita IRA-743:lla ajettiin myös monimetallisilla liuoksilla, mutta silloin havaittiin hartsin kapasiteetin pienenevän hartsin myrkyttymisen takia.
Resumo:
Dental oxide ceramics have been inspired by their biocompability and mechanical properties which have made durable all-ceramic structures possible. Clinical longevity of the prosthetic structures is dependent on effective bonding with luting cements. As the initial shear bond strength values can be comparable with several materials and procedures, long-term durability is affected by ageing. Aims of the current study were: to measure the shear bond strength of resin composite-to-ceramics and to evaluate the longevity of the bond; to analyze factors affecting the bond, with special emphasis on: the form of silicatization of the ceramic surface; form of silanization; type of resin primer and the effect of the type of the resin composite luting cement; the effect of ageing in water was studied regarding its effect to the endurance of the bond. Ceramic substrates were alumina and yttrium stabilized zirconia. Ceramic conditioning methods included tribochemical silicatization and use of two silane couplings agents. A commercial silane primer was used as a control silane. Various combinations of conditioning methods, primers and resin cements were tested. Bond strengths were measured by shear bond strength method. The longevity of the bond was generally studied by thermocycling the materials in water. Additionally, in one of the studies thermal cycling was compared with long-term water storaging. Results were analysed statistically with ANOVA and Weibull analysis. Tribochemical treatment utilizing air pressure of 150 kPa resulted shear bond strengths of 11.2 MPa to 18.4 MPa and air pressure of 450 kPa 18.2 MPa to 30.5 MPa, respectively. Thermocycling of 8000 cycles or four years water storaging both decreased shear bond strength values to a range of 3.8 MPa to 7.2 MPa whereas initial situation varied from 16.8. Mpa to 23.0 MPa. The silane used in studies had no statistical significance. The use of primers without 10-MDP resulted spontaneous debonding during thermocycling or shear bond strengths below 5 MPa. As conclusion, the results showed superior long-term bonding with primers containing 10-MDP. Silicatization with silanizing showed improved initial shear bond strength values which considerably decreased with ageing in water. Thermal cycling and water storing for up to four years played the major role in reduction of bond strength, which could be due to thermal fatigue of the bonding interface and hydrolytic degradation of the silane coupled interface.
Resumo:
Tässä työssä tutkittiin FE-analyysin soveltamista S960 QC teräksisen I-profiilin kestävyyden määrittämisessä. Työn tavoitteena oli tarkastella nykyisten suunnitteluohjeiden soveltuvuutta ultralujille teräksille ja koota ohjemateriaali I-profiilin optimoimisesta sekä FE-analyysin hyö-dyntämisestä I-profiilin staattisen ja dynaamisen kestävyyden määrittämisessä. I-profiili mitoitettiin ja optimoitiin Eurokoodi 3:ssa esitettyjen PL3 mukaisten mitoitusohjeiden avulla. Rakenteelle suoritettiin Eurokoodi 3:n ja IIW:n mukaiset lommahdus-, kiepahdus- ja vä-symiskestävyystarkastelut. Väsymistarkastelussa sovellettiin nimellisen jännityksen, rakenteelli-sen jännityksen ja tehollisen lovijännityksen menetelmiä sekä murtumismekaniikkaa. Rakenteel-lisen jännityksen menetelmässä sovellettiin lisäksi lineaarista ja parabolista pintaa pitkin ekstra-polointia, paksuuden yli linearisointia sekä Dong:in menetelmää. Lommahdus-, kiepahdus- ja väsymistarkasteluissa hyödynnettiin analyyttistä laskentaa, FE-analyysiä sekä Frank2d sovellusta. Tarkastelujen perusteella voidaan todeta, että analyyttisillä menetelmillä saadaan numeerisia me-netelmiä varmemmalla puolella olevia tuloksia. Lommahdustarkastelussa ero tulosten välillä on suurimmillaan 8 % ja kiepahdustarkastelussa suurimmillaan 20 % mutta väsymistarkastelussa saadut tulokset eroavat keskenään huomattavasti. Väsymistarkastelussa tehollisen lovijännityksen menetelmällä sekä rakenteellisen jännityksen menetelmän Dong:in menetelmällä saadaan huo-mattavasti muita menetelmiä pidempiä kestoikiä, kun taas yksinkertaisemmilla menetelmillä saa-dut kestoiät ovat lyhyempiä. Rakenteen kestävyyden määrittäminen analyyttisillä menetelmillä on melko helppoa, mutta tu-lokset ovat monesti liian konservatiivisia. FE-analyysillä saadaan puolestaan hyvin tarkkoja tu-loksia mallin ollessa yksityiskohtainen. Mallintaminen on kuitenkin aikaa ja resursseja vievää ja vaatii käyttökokemusta. FE-analyysin mahdolliset hyödyt on aina arvioitava tapauskohtaisesti tarkasteltavan geometrian, kuormitusten ja reunaehtojen perusteella.