37 resultados para Power Systems, Load Model, Indentification
em Doria (National Library of Finland DSpace Services) - National Library of Finland, Finland
Resumo:
Condition monitoring systems for physical assets are constantly becoming more and more common in the industrial sector. At the same time an increasing portion of asset monitoring systems are being remotely supported. As global competitors are actively developing solutions for condition monitoring and condition-based maintenance, which it enables, Wärtsilä too feels the pressure to provide customers with more sophisticated condition-based maintenance solutions. The main aim of this thesis study is to consider Wärtsilä remote condition monitoring solutions and how they relate to similar solutions from other suppliers and end customers’ needs, in the context of offshore assets. A theoretical study is also included in the thesis, where the concepts of condition monitoring, condition-based maintenance, maintenance management and physical asset management are introduced.
Resumo:
This study compares different electric propulsion systems. Results of the analysis of all the advantages and disadvantages of the different propulsion systems are given. This thesis estimates possibilities to apply different diesel-electric propulsion concepts for different vessel types. Small and medium size vessel’s power ranges are studied. The optimal delivery system is chosen. This choice is made on the base of detailed study of the concepts, electrical equipment market and comparison of mass, volume and efficiency parameters. In this thesis three marine generators are designed. They are: salient pole synchronous generator and two permanent magnet synchronous generators. Their electrical, dimensional, cost and efficiency parameters are compared. To understand all the benefits diagrams with these parameters are prepared. Possible benefits and money savings are estimated. As the result the advantages, disadvantages and boundary conditions for the permanent magnet synchronous generator application in marine electric-power systems are found out.
Resumo:
Ambitious energy targets set by EU put pressures to increase share of renewable electricity supply in this and next decades and therefore, some EU member countries have boosted increasing renewable energy generation capacity by implementing subsidy schemes on national level. In this study, two different change approaches to increase renewable energy supply and increase self-sufficiency of supply are assessed with respect to their impacts on power system, electricity market and electricity generation costs in Finland. It is obtained that the current electricity generation costs are high compared to opportunities of earnings from present-day investor’s perspective. In addition, the growth expectations of consumptions and the price forecasts do not stimulate investing in new generation capacity. Revolutionary transition path is driven by administrative and political interventions to achieve the energy targets. Evolutionary transition path is driven by market-based mechanisms, such as market itself and emission trading scheme. It is obtained in this study that in the revolutionary transition path operation of market-based mechanisms is distorted to some extent and it is likely that this path requires providing more public financial resources compared to evolutionary transition path. In the evolutionary transition path the energy targets are not achieved as quickly but market-based mechanisms function better and investment environment endures more stable compared to revolutionary transition path.
Resumo:
In the doctoral dissertation, low-voltage direct current (LVDC) distribution system stability, supply security and power quality are evaluated by computational modelling and measurements on an LVDC research platform. Computational models for the LVDC network analysis are developed. Time-domain simulation models are implemented in the time-domain simulation environment PSCAD/EMTDC. The PSCAD/EMTDC models of the LVDC network are applied to the transient behaviour and power quality studies. The LVDC network power loss model is developed in a MATLAB environment and is capable of fast estimation of the network and component power losses. The model integrates analytical equations that describe the power loss mechanism of the network components with power flow calculations. For an LVDC network research platform, a monitoring and control software solution is developed. The solution is used to deliver measurement data for verification of the developed models and analysis of the modelling results. In the work, the power loss mechanism of the LVDC network components and its main dependencies are described. Energy loss distribution of the LVDC network components is presented. Power quality measurements and current spectra are provided and harmonic pollution on the DC network is analysed. The transient behaviour of the network is verified through time-domain simulations. DC capacitor guidelines for an LVDC power distribution network are introduced. The power loss analysis results show that one of the main optimisation targets for an LVDC power distribution network should be reduction of the no-load losses and efficiency improvement of converters at partial loads. Low-frequency spectra of the network voltages and currents are shown, and harmonic propagation is analysed. Power quality in the LVDC network point of common coupling (PCC) is discussed. Power quality standard requirements are shown to be met by the LVDC network. The network behaviour during transients is analysed by time-domain simulations. The network is shown to be transient stable during large-scale disturbances. Measurement results on the LVDC research platform proving this are presented in the work.
Resumo:
Currently widely accepted consensus is that greenhouse gas emissions produced by the mankind have to be reduced in order to avoid further global warming. The European Union has set a variety of CO2 reduction and renewable generation targets for its member states. The current energy system in the Nordic countries is one of the most carbon free in the world, but the aim is to achieve a fully carbon neutral energy system. The objective of this thesis is to consider the role of nuclear power in the future energy system. Nuclear power is a low carbon energy technology because it produces virtually no air pollutants during operation. In this respect, nuclear power is suitable for a carbon free energy system. In this master's thesis, the basic characteristics of nuclear power are presented and compared to fossil fuelled and renewable generation. Nordic energy systems and different scenarios in 2050 are modelled. Using models and information about the basic characteristics of nuclear power, an opinion is formed about its role in the future energy system in Nordic countries. The model shows that it is possible to form a carbon free Nordic energy system. Nordic countries benefit from large hydropower capacity which helps to offset fluctuating nature of wind power. Biomass fuelled generation and nuclear power provide stable and predictable electricity throughout the year. Nuclear power offers better energy security and security of supply than fossil fuelled generation and it is competitive with other low carbon technologies.
Resumo:
The main objective of the study was to define the methodology for assessing the limits for application island grids instead of interconnecting with existing grid infrastructure. The model for simulation of grid extension distance and levelised cost of electricity has been developed and validated by the case study in Finland. Thereafter, sensitivities of the application limits were examined with the respect to operational environment, load conditions, supply security and geographical location. Finally, recommendations for the small-scale rural electrification projects in the market economy environment have been proposed.
Resumo:
The application of VSC-HVDC technology throughout the world has turned out to be an efficient solution regarding a large share of wind power in different power systems. This technology enhances the overall reliability of the grid by utilization of the active and reactive power control schemes which allows to maintain frequency and voltage on busbars of the end-consumers at the required level stated by the network operator. This master’s thesis is focused on the existing and planned wind farms as well as electric power system of the Åland Islands. The goal is to analyze the wind conditions of the islands and appropriately predict a possible production of the existing and planned wind farms with a help of WAsP software program. Further, to investigate the influence of increased wind power it is necessary to develop a simulation model of the electric grid and VSC-HVDC system in PSCAD and examine grid response to different wind power production cases with respect to the grid code requirements and ensure the stability of the power system.
Resumo:
Electric motors driven by adjustable-frequency converters may produce periodic excitation forces that can cause torque and speed ripple. Interaction with the driven mechanical system may cause undesirable vibrations that affect the system performance and lifetime. Direct drives in sensitive applications, such as elevators or paper machines, emphasize the importance of smooth torque production. This thesis analyses the non-idealities of frequencyconverters that produce speed and torque ripple in electric drives. The origin of low order harmonics in speed and torque is examined. It is shown how different current measurement error types affect the torque. As the application environment, direct torque control (DTC) method is applied to permanent magnet synchronous machines (PMSM). A simulation model to analyse the effect of the frequency converter non-idealities on the performance of the electric drives is created. Themodel enables to identify potential problems causing torque vibrations and possibly damaging oscillations in electrically driven machine systems. The model is capable of coupling with separate simulation software of complex mechanical loads. Furthermore, the simulation model of the frequency converter's control algorithm can be applied to control a real frequency converter. A commercial frequencyconverter with standard software, a permanent magnet axial flux synchronous motor and a DC motor as the load are used to detect the effect of current measurement errors on load torque. A method to reduce the speed and torque ripple by compensating the current measurement errors is introduced. The method is based on analysing the amplitude of a selected harmonic component of speed as a function oftime and selecting a suitable compensation alternative for the current error. The speed can be either measured or estimated, so the compensation method is applicable also for speed sensorless drives. The proposed compensation method is tested with a laboratory drive, which consists of commercial frequency converter hardware with self-made software and a prototype PMSM. The speed and torque rippleof the test drive are reduced by applying the compensation method. In addition to the direct torque controlled PMSM drives, the compensation method can also beapplied to other motor types and control methods.
Resumo:
Työn tarkoituksena oli analysoida polttoainesauvojen käyttäytymistä Loviisan ydinvoimalaitoksen tehonsäätöajossa. Sähkömarkkinoiden vapautuminen Pohjoismaissa sekä tämän seurauksena vaihteleva sähkön markkinahinta ovat ajaneet sähkötuottajat tilanteeseen, jossa tuotanto aiempaa enemmän mukautuu markkinatilanteeseen. Näin ollen myös Loviisan ydinvoimalaitoksen osallistuminen sähkön tuotannon säätelyyn saattaa tulevaisuudessa olla ajankohtaista. Ennen kuin reaktorin tehonsäätöajoa voidaan alkaa toteuttaa, tulee varmistua siitä, että polttoainesauvassa tehonsäätöjen seurauksena tapahtuvat muutokset eivät aiheuta epäsuotuisia käyttäytymisilmiöitä. Työssä tarkastellaan kahden Loviisan ydinvoimalaitoksen polttoainetoimittajan, British Nuclear Fuels plc:n ja venäläisen TVEL:n ensinippujen polttoainesauvan käyttäytymistä tehonsäätötapauksissa. Työssä tarkastellut tehonsäätötapaukset on pyritty valitsemaan niin, että ne kuvaisivat tulevaisuudessa mahdollisesti toteutettavia tehonsäätöjä. Laskentatapauksien sauvatehohistoriat on generoitu HEXBU-3D sydänsimulaattoriohjelmalla lasketun nelivuotisen perustehohistorian pohjalta lisäämällä säätösauvan aiheuttama reaktoritehon muutos, säätösauvan viereisen polttoainenipun aksiaalitehon muutos sekä säätösauvan rakenteen aiheuttama paikallinen tehopiikki säätösauvan vieressä. Työssä tarkastellaan tehonsäätöjen toteuttamista eri tehotasoille ja vaihtelevilla määrillä tehonsäätösyklejä. Työssä käsitellyt laskentatapaukset on jaoteltu reaktorin ajotavan mukaan seuraavasti: peruskuorma-ajo, viikonloppusäätö ja päiväsäätö. Laskenta suoritettiin ydinpolttoaineen käyttäytymistä kuvaavaa ENIGMA-B 7.3.0 ohjelmaa apuna käyttäen. Laskelmien tulokset osoittavat, että molempien polttoainetoimittajien ensinippujen sauvat kestävät reaktorin tehonsäätöajoa rajoituksetta tarkastelluissa laskentatapauksissa. ENIGMA-ohjelman sisältämät mallit, jotka ennustavat polttoainesauvan suojakuoren vaurioitumistodennäköisyyden jännityskorroosion tai väsymismurtuman kautta, eivät näytä mitään merkkejä vaurioitumisesta. BNFL:n polttoainesauva saavuttaa kuitenkin suurempia väsymismurtumatodennäköisyyden arvoja. Tämä johtuu siitä, että polttoainepelletin ja suojakuoren välinen mekaaninen vuorovaikutus syntyy BNFL:n sauvassa aikaisemmin, joka taas johtaa suurempaan määrään sauvaa rasittavia muodonmuutoksia tehonnostotilanteissa. TVEL:n Zr1%Nb -materiaalista valmistetun suojakuoren käyttäytymistä ei voida kuitenkaan suoraan näiden laskujen perusteella arvioida, sillä ENIGMA-ohjelman mallit perustuvat Zircaloy-suojakuorimateriaaleilla suoritettuihin kokeisiin.
Resumo:
Tutkielman tavoitteena oli tarkastella telekommunikaatiolaitevalmistajien liiketoimintamalleja. Tutkielma jakaantuu teoreettiseen ja empiiriseen osaan. Teoreettinen osa keskittyy lähinnä liiketoimintamallin käsitteen määrittelyyn. Olemassa olevien määritelmien, sekä liiketoimintamallin käsitteeseen läheisesti liittyvien termien, pohjalta luotiin liiketoimintamallille uusi malli. Tutkielman empiirinen osa keskittyy case-yritys Cisco Systemsin liiketoimintamallin määrittelyyn ja kehityksen kuvaamiseen. Liiketoimintamallin kehitystä seurattiin kahden vuoden ajalta perehtymällä lähinnä yrityksen lehdistötiedotteisiin, artikkeleihin ja muuhun julkiseen materiaaliin. Ciscon lisäksi empiirisessä osassa tutkittiin kahdeksan muun laitevalmistajan liiketoimintamallien kehitystä. Empiirisen osan päätavoitteena oli selvittää, miten telekommunikaatiolaitevalmistajien liiketoimintamallit kehittyvät nyt ja tulevaisuudessa.
Resumo:
The subject of this master’s thesis is to research grounding in a particular wind power application. The aim is to define how the grounding from different points effects to the function of the whole system. The investigated subjects are generator voltage spikes, ground currents and system fault situations. The first part of this thesis represents power electronics, which is commonly used in wind power systems. The second part concentrates more to the grounding, electrical safety demands and potential fault situations. The object of the simulations is to investigate voltage spikes and fault situations. Measurements will be made with small-scale setup and in the last part simulation and measurement results are compared to each other and to a full-scale system.
Resumo:
Huoli ympäristön tilasta ja fossiilisten polttoaineiden hinnan nousu ovat vauhdittaneet tutkimusta uusien energialähteiden löytämiseksi. Polttokennot ovat yksi lupaavimmista tekniikoista etenkin hajautetun energiantuotannon, varavoimalaitosten sekä liikennevälineiden alueella. Polttokenno on tehonlähteenä kuitenkin hyvin epäideaalinen, ja se asettaa tehoelektroniikalle lukuisia erityisvaatimuksia. Polttokennon kytkeminen sähköverkkoon on tavallisesti toteutettu käyttämällä galvaanisesti erottavaa DC/DC hakkuria sekä vaihtosuuntaajaa sarjassa. Polttokennon kulumisen estämiseksi tehoelektroniikalta vaaditaan tarkkaa polttokennon lähtövirran hallintaa. Perinteisesti virran hallinta on toteutettu säätämällä hakkurin tulovirtaa PI (Proportional and Integral) tai PID (Proportional, Integral and Derivative) -säätimellä. Hakkurin epälineaarisuudesta johtuen tällainen ratkaisu ei välttämättä toimi kaukana linearisointipisteestä. Lisäksi perinteiset säätimet ovat herkkiä mallinnusvirheille. Tässä diplomityössä on esitetty polttokennon jännitettä nostavan hakkurin tilayhtälökeskiarvoistusmenetelmään perustuva malli, sekä malliin perustuva diskreettiaikainen integroiva liukuvan moodin säätö. Esitetty säätö on luonteeltaan epälineaarinen ja se soveltuu epälineaaristen ja heikosti tunnettujen järjestelmien säätämiseen.
Resumo:
Tämän diplomityön tavoitteena oli tutkia tasehallinnan kehittämismahdollisuuksia Suomessa järjestelmävastaavan näkökulmasta. Sähköjärjestelmässä tulee vallita jatkuvasti tasapaino tuotannon ja kulutuksen välillä, tämän järjestelmävastaavan vastuulla olevan tasapainon ylläpitoa kutsutaan tehotasapainon hallinnaksi. Työssä pääasiasiallinen huomio oli markkinalähtöisessä tehotasapainon hallinnan kehittämisessä. Tuotantosuunnitelmat ovat ratkaisevassa osassa sähköjärjestelmän muutoksia ennustettaessa ja suunniteltaessa. Pääasiassa tutkimus kohdistuu tuotantosuunnitelmien tarkentamisen mahdollisuuksien analysointiin sekä tarkentamisesta aiheutuvien muutosten selvittämiseen. Työn yhteydessä toteutettiin sopivalla otannalla kyselytutkimus, jonka oli tarkoitus antaa tietoa Eurooppalaisista käytännöistä asian suhteen. Tutkimusten pohjalta päädyttiin malliin, jossa tuotantosuunnitelmien jaksonpituutta lyhennettäisiin nykyisestä 60 minuutista 15 minuuttiin. 15 minuutin jaksonpituus ulottuisi koko tuotantotaseen käsittelyyn, mukaan lukien säätösähkömarkkinat ja muut tehokaupat.
Resumo:
The objective of this master’s thesis is to investigate the loss behavior of three-level ANPC inverter and compare it with conventional NPC inverter. The both inverters are controlled with mature space vector modulation strategy. In order to provide the comparison both accurate and detailed enough NPC and ANPC simulation models should be obtained. The similar control model of SVM is utilized for both NPC and ANPC inverter models. The principles of control algorithms, the structure and description of models are clarified. The power loss calculation model is based on practical calculation approaches with certain assumptions. The comparison between NPC and ANPC topologies is presented based on results obtained for each semiconductor device, their switching and conduction losses and efficiency of the inverters. Alternative switching states of ANPC topology allow distributing losses among the switches more evenly, than in NPC inverter. Obviously, the losses of a switching device depend on its position in the topology. Losses distribution among the components in ANPC topology allows reducing the stress on certain switches, thus losses are equally distributed among the semiconductors, however the efficiency of the inverters is the same. As a new contribution to earlier studies, the obtained models of SVM control, NPC and ANPC inverters have been built. Thus, this thesis can be used in further more complicated modelling of full-power converters for modern multi-megawatt wind energy conversion systems.
Resumo:
All over the world power systems become bigger and bigger every day. New equipment is installed, new feeders are constructed, new power units are installed. Some old elements of the network, however, are not changed in time. As a result, “bottlenecks” for capacity transmission can occur. By locked power problem the situation when a power plant has installed capacity exceeding the power it can actually deliver is usually meant. Regime, scheme or even technical restrictions-related issues usually cause this kind of problem. It is really important, since from the regime point of view it is typical decision to have a mobile capacity reserve, in case of malfunctions. And, what can be even more significant, power plant owner (JSC Fortum in our case) losses his money because of selling less electrical energy. The goal of master`s thesis is to analyze the current state of Chelyabinsk power system and the CHP-3 (Combined Heat and Power plant) in particular in relation with it`s ability to deliver the whole capacity of the CHP in it`s existing state and also taking into consideration the prospect of power unit 3 installation by the fourth quarter of 2010. The thesis contains some general information about the UPS of Russia, CPS of Ural, power system of Chelyabinsk and the Chelyabinsk region itself. Then the CHP-3 is described from technical point of view with it`s equipment observation. Regimes for the nowadays power system and for the system after the power unit 3 installation are reviewed. The problems occurring are described and, finally, a solution is offered.