Resumo:
Potentiometric sensors are very attractive tools for chemical analysis because of their simplicity, low power consumption and low cost. They are extensively used in clinical diagnostics and in environmental monitoring. Modern applications of both fields require improvements in the conventional construction and in the performance of the potentiometric sensors, as the trends are towards portable, on-site diagnostics and autonomous sensing in remote locations. The aim of this PhD work was to improve some of the sensor properties that currently hamper the implementation of the potentiometric sensors in modern applications. The first part of the work was concentrated on the development of a solid-state reference electrode (RE) compatible with already existing solid-contact ion-selective electrodes (ISE), both of which are needed for all-solid-state potentiometric sensing systems. A poly(vinyl chloride) membrane doped with a moderately lipophilic salt, tetrabutylammonium-tetrabutylborate (TBA-TBB), was found to show a satisfactory stability of potential in sample solutions with different concentrations. Its response time was nevertheless slow, as it required several minutes to reach the equilibrium. The TBA-TBB membrane RE worked well together with solid-state ISEs in several different situations and on different substrates enabling a miniature design. Solid contacts (SC) that mediate the ion-to-electron transduction are crucial components of well-functioning potentiometric sensors. This transduction process converting the ionic conduction of an ion-selective membrane to the electronic conduction in the circuit was studied with the help of electrochemical impedance spectroscopy (EIS). The solid contacts studied were (i) the conducting polymer (CP) poly(3,4-ethylienedioxythiophene) (PEDOT) and (ii) a carbon cloth having a high surface area. The PEDOT films were doped with a large immobile anion poly(styrene sulfonate) (PSS-) or with a small mobile anion Cl-. As could be expected, the studied PEDOT solid-contact mediated the ion-toelectron transduction more efficiently than the bare glassy carbon substrate, onto which they were electropolymerized, while the impedance of the PEDOT films depended on the mobility of the doping ion and on the ions in the electrolyte. The carbon cloth was found to be an even more effective ion-to-electron transducer than the PEDOT films and it also proved to work as a combined electrical conductor and solid contact when covered with an ion-selective membrane or with a TBA-TBB-based reference membrane. The last part of the work was focused on improving the reproducibility and the potential stability of the SC-ISEs, a problem that culminates to the stability of the standard potential E°. It was proven that the E° of a SC-ISE with a conducting polymer as a solid contact could be adjusted by reducing or oxidizing the CP solid contact by applying current pulses or a potential to it, as the redox state of the CP solid-contact influences the overall potential of the ISE. The slope and thus the analytical performance of the SC-ISEs were retained despite the adjustment of the E°. The shortcircuiting of the SC-ISE with a conventional large-capacitance RE was found to be a feasible instrument-free method to control the E°. With this method, the driving force for the oxidation/reduction of the CP was the potential difference between the RE and the SC-ISE, and the position of the adjusted potential could be controlled by choosing a suitable concentration for the short-circuiting electrolyte. The piece-to-piece reproducibility of the adjusted potential was promising, and the day-today reproducibility for a specific sensor was excellent. The instrumentfree approach to control the E° is very attractive considering practical applications.
Resumo:
Potentiometric ion sensors are a very important subgroup of electrochemical sensors, very attractive for practical applications due to their small size, portability, low-energy consumption, relatively low cost and not changing the sample composition. They are investigated by the researchers from many fields of science. The continuous development of this field creates the necessity for a detailed description of sensor response and the electrochemical processes important in the practical applications of ion sensors. The aim of this thesis is to present the existing models available for the description of potentiometric ion sensors as well as their applicability and limitations. This includes the description of the diffusion potential occurring at the reference electrodes. The wide range of existing models, from most idealised phase boundary models to most general models, including migration, is discussed. This work concentrates on the advanced modelling of ion sensors, namely the Nernst-Planck-Poisson (NPP) model, which is the most general of the presented models, therefore the most widely applicable. It allows the modelling of the transport processes occurring in ion sensors and generating the potentiometric response. Details of the solution of the NPP model (including the numerical methods used) are shown. The comparisons between NPP and the more idealized models are presented. The applicability of the model to describe the formation of diffusion potential in reference electrode, the lower detection limit of both ion-exchanger and neutral carrier electrodes and the effect of the complexation in the membrane are discussed. The model was applied for the description of both types of electrodes, i.e. with the inner filling solution and solidcontact electrodes. The NPP model allows the electrochemical methods other than potentiometry to be described. Application of this model in Electrochemical Impedance Spectroscopy is discussed and a possible use in chrono-potentiometry is indicated. By combining the NPP model with evolutionary algorithms, namely Hierarchical Genetic Strategy (HGS), a novel method allowing the facilitation of the design of ion sensors was created. It is described in detail in this thesis and its possible applications in the field of ion sensors are indicated. Finally, some interesting effects occurring in the ion sensors (i.e. overshot response and influence of anionic sites) as well as the possible applications of NPP in biochemistry are described.
Resumo:
In the drilling processes and especially deep-hole drilling process, the monitoring system and having control on mechanical parameters (e.g. Force, Torque,Vibration and Acoustic emission) are essential. The main focus of this thesis work is to study the characteristics of deep-hole drilling process, and optimize the monitoring system for controlling the process. The vibration is considered as a major defect area of the deep-hole drilling process which often leads to breakage of the drill, therefore by vibration analysis and optimizing the workpiecefixture, this area is studied by finite element method and the suggestions are explained. By study on a present monitoring system, and searching on the new sensor products, the modifications and recommendations are suggested for optimize the present monitoring system for excellent performance in deep-hole drilling process research and measurements.
Resumo:
A recently developed calculation method to determine stoichiometric dissociation constants of weak acids from potentiometric titration data is described. The titration data from three different weak acids in aqueous salt solutions at 25 °C were used as examples of the use of the method. The salt alone determined the ionic strength of the solutions considered in this study, and salt molalities up to 0,5 mol kg -1 were used.
Resumo:
The simple single-ion activity coefficient equation originating from the Debye-Hückel theory was used to determine the thermodynamic and stoichiometric dissociation constants of weak acids from data concerning galvanic cells. Electromotive force data from galvanic cells without liquid junctions, which was obtained from literature, was studied in conjuction with the potentiometric titration data relating to aqueous solutions at 298.15 K. The dissociation constants of weak acids could be determined by the presented techniques and almost all the experimental data studied could be interpreted within the range of experimental error. Potentiometric titration has been used here and the calculation methods were developed to obtain the thermodynamic and stoichiometric dissociation constants of some weak acids in aqueous solutions at 298.15 K. The ionic strength of titrated solutions were adjusted using an inert electrolyte, namely, sodium or potassium chloride. Salt content alonedetermines the ionic strength. The ionic strength of the solutions studied varied from 0.059 mol kg-1 to 0.37 mol kg-1, and in some cases up to 1.0 mol kg-1. The following substances were investigated using potentiometric titration: aceticacid, propionic acid, L-aspartic acid, L-glutamic acid and bis(2,2-dimethyl-3-oxopropanol) amine.
Resumo:
In the work eddy current sensors are described and evaluated. Theoretical part includes physical basics of the eddy currents, overview of available commercial products and technologies. Industrial sensors operation was assessed based on several working modes. Apart from this, the model was created in Matlab Simulink with Xilinx Blockset and then translated into a Xilinx ISE Design Suite compatible project. The performance of the resulting implementation was compared to the existing implementation in the Xilinx Spartan 3 FPGA board with the custom made sensor. Additionally, an introduction to FPGAs and VHDL is presented.
Resumo:
Various categories of food packaging indicators namely; VTT, Ageless Eye, Mocon, Åbo Akademi and Impak were selected and incorporated into food trays manufactured at LUT packaging laboratory. Each of these food packaging indicators was used to investigate (visually and qualitatively) the transmission of oxygen through the seal, and tray material, as well as to detect microbial activity within the content of the package. Applications of different methods of gas flushing, content variation and introduction of two distinct levels of oxygen scavengers were employed as treatments to evaluate the packaging performance of the food packaging indicators. Ease of handling of each food packaging indicator was also taken into considerations. Findings showed that for packages, which contained chicken product, the amount of oxygen in the package, measured immediately after the sealing operation on the first day gradually decreased to zero percent by the third day of the storage period. The oxygen level remained at this point throughout the duration of storage for the chicken packages. Besides, level of oxygen in the packages without product continued to increase with the storage time, at moderate rate of 0.1% for 100%N2 and 0.3% for 30%CO2/70%N2 empty packages. More carbon dioxide gas was recorded for packages flushed with 30%CO2/70%N2. Results also revealed that visual analysis of one of the color indicators for example Ageless Eye, conformed to the data derived from the luminescence food-packaging indicator. This shows that packaging operation of the packaging line was considerably stable, and efficient with negligible exception. However, it was found that most of the food packaging indicators investigated in this research study exhibited considerable packaging challenges, such as, reaction with the content of the package (Impak); over sensitivity (Åbo Akademi and Impak); ease of handling problem (Åbo Akademi); and ease of activation problem (VTT indicators). In this study, the strengths and limitations of different indicators were analyzed. This study demonstrates the applicability of various indicators in MAP using chicken package application.
Resumo:
This literature review aims to clarify what is known about map matching by using inertial sensors and what are the requirements for map matching, inertial sensors, placement and possible complementary position technology. The target is to develop a wearable location system that can position itself within a complex construction environment automatically with the aid of an accurate building model. The wearable location system should work on a tablet computer which is running an augmented reality (AR) solution and is capable of track and visualize 3D-CAD models in real environment. The wearable location system is needed to support the system in initialization of the accurate camera pose calculation and automatically finding the right location in the 3D-CAD model. One type of sensor which does seem applicable to people tracking is inertial measurement unit (IMU). The IMU sensors in aerospace applications, based on laser based gyroscopes, are big but provide a very accurate position estimation with a limited drift. Small and light units such as those based on Micro-Electro-Mechanical (MEMS) sensors are becoming very popular, but they have a significant bias and therefore suffer from large drifts and require method for calibration like map matching. The system requires very little fixed infrastructure, the monetary cost is proportional to the number of users, rather than to the coverage area as is the case for traditional absolute indoor location systems.
Resumo:
The emergence of depth sensors has made it possible to track – not only monocular cues – but also the actual depth values of the environment. This is especially useful in augmented reality solutions, where the position and orientation (pose) of the observer need to be accurately determined. This allows virtual objects to be installed to the view of the user through, for example, a screen of a tablet or augmented reality glasses (e.g. Google glass, etc.). Although the early 3D sensors have been physically quite large, the size of these sensors is decreasing, and possibly – eventually – a 3D sensor could be embedded – for example – to augmented reality glasses. The wider subject area considered in this review is 3D SLAM methods, which take advantage of the 3D information available by modern RGB-D sensors, such as Microsoft Kinect. Thus the review for SLAM (Simultaneous Localization and Mapping) and 3D tracking in augmented reality is a timely subject. We also try to find out the limitations and possibilities of different tracking methods, and how they should be improved, in order to allow efficient integration of the methods to the augmented reality solutions of the future.
Resumo:
In this thesis, bacteriorhodopsin (BR) photosensor’s optical and electrical properties were studied. The BR sensor consisted of a dry film with BR in polyvinyl alcohol and covered with transparent conductors. In the experiments the BR photocycle was started with two lasers. The characteristics of the BR sensor were measured in two ways. The first approach was theoretical and it required knowing the laser parameters. The second way required assembling a measurement setup for the optical response measurements. However, no measurable results were obtained due to low laser power. The photoelectric response was measured in the experiments with two laser systems and the amplifier was tested. In the experiment with a Cavitar laser, the photoelectric response was obtained. In the experiment with FemtoFiber Pro laser, the photoelectric response was not measured. The expected amplitude of the response was obtained. The experimental data was analyzed and possible solutions for reducing the interference were given.
Resumo:
Stress is a phenomenon that on some level affects everyone’s lives on a daily basis. The autonomic nervous system controls the varying levels of stress at any given time. The responses of the autonomic nervous system adjust the body to cope with changing external and internal conditions. During high-stress situations the body is forced into a state of heightened alertness, which passes when the stressor is removed. The stressor can be any external or internal event that causes the body to respond. Stress is a very versatile phenomenon that can be both a cause and an indicator of other medical conditions, for example cardiovascular disease. Stress detection can therefore be helpful in identifying these conditions and monitoring the overall emotional state of a person. Electrodermal activity (EDA) is one of the most easily implemented ways to monitor the activity of the autonomic nervous system. EDA describes changes occurring in the various electrical properties of the skin, including skin conductivity and resistance. Increased emotional sweating has been proven to be one possible indication of stress. On the surface of the skin, increased sweating translates to increased skin conductivity, which can be observed through EDA measurements. This makes electrodermal activity a very useful tool in a wide range of applications where it is desirable to observe changes in a person’s stress level. EDA can be recorded by using specialized body sensors placed on specific locations on the body. Most commonly used recording sites are the palms of the hands due to the high sweat gland density on those areas. Measurement is done using at least two electrodes attached to the skin, and recording the electrical conductance between them. This thesis implements a prototype of a wireless EDA measurement system. The feasibility of the prototype is also verified with a small group of test subjects. EDA was recorded from the subjects while they were playing a game of Tetris. The goal was to observe variations in the measured EDA that would indicate changes in the subjects’ stress levels during the game. The analysis of the obtained measurement results confirmed the connection between stress and recorded EDA. During the game, random occurrences of lowered skin resistance were clearly observable, which indicates points in the game where the player felt more anxious. A wireless measurement system has the potential of offering more flexible and comfortable long-term measuring of EDA, and could be utilized in a wide range of applications.