14 resultados para PRUSSIAN BLUE ANALOG

em Doria (National Library of Finland DSpace Services) - National Library of Finland, Finland


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Selostus: Tarhattujen sinikettujen vuodenaikainen ja vuorokautinen aktiivisuus

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Selostus: Näköesteen vaikutus sinikettujen hyllynkäyttöön

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Selostus: Ryhmäkoon ja varhaisen käsittelyn vaikutus tarhattujen sinikettujen hyvinvointiin

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Selostus: Siniset liimapyydykset ovat keltaisia liimapyydyksiä tehokkaampia peltoluteen tarkkailussa

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Soitinnus: trumpetti, orkesteri.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Soitinnus: trumpetti, orkesteri.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, the feasibility of the floating-gate technology in analog computing platforms in a scaled down general-purpose CMOS technology is considered. When the technology is scaled down the performance of analog circuits tends to get worse because the process parameters are optimized for digital transistors and the scaling involves the reduction of supply voltages. Generally, the challenge in analog circuit design is that all salient design metrics such as power, area, bandwidth and accuracy are interrelated. Furthermore, poor flexibility, i.e. lack of reconfigurability, the reuse of IP etc., can be considered the most severe weakness of analog hardware. On this account, digital calibration schemes are often required for improved performance or yield enhancement, whereas high flexibility/reconfigurability can not be easily achieved. Here, it is discussed whether it is possible to work around these obstacles by using floating-gate transistors (FGTs), and analyze problems associated with the practical implementation. FGT technology is attractive because it is electrically programmable and also features a charge-based built-in non-volatile memory. Apart from being ideal for canceling the circuit non-idealities due to process variations, the FGTs can also be used as computational or adaptive elements in analog circuits. The nominal gate oxide thickness in the deep sub-micron (DSM) processes is too thin to support robust charge retention and consequently the FGT becomes leaky. In principle, non-leaky FGTs can be implemented in a scaled down process without any special masks by using “double”-oxide transistors intended for providing devices that operate with higher supply voltages than general purpose devices. However, in practice the technology scaling poses several challenges which are addressed in this thesis. To provide a sufficiently wide-ranging survey, six prototype chips with varying complexity were implemented in four different DSM process nodes and investigated from this perspective. The focus is on non-leaky FGTs, but the presented autozeroing floating-gate amplifier (AFGA) demonstrates that leaky FGTs may also find a use. The simplest test structures contain only a few transistors, whereas the most complex experimental chip is an implementation of a spiking neural network (SNN) which comprises thousands of active and passive devices. More precisely, it is a fully connected (256 FGT synapses) two-layer spiking neural network (SNN), where the adaptive properties of FGT are taken advantage of. A compact realization of Spike Timing Dependent Plasticity (STDP) within the SNN is one of the key contributions of this thesis. Finally, the considerations in this thesis extend beyond CMOS to emerging nanodevices. To this end, one promising emerging nanoscale circuit element - memristor - is reviewed and its applicability for analog processing is considered. Furthermore, it is discussed how the FGT technology can be used to prototype computation paradigms compatible with these emerging two-terminal nanoscale devices in a mature and widely available CMOS technology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this work was to study techniques to extract and purify of anthocyanins from purple-blue potato. This topic was determined as a master’s thesis and it was done in collaboration with the Food Chemistry and Food Development Department of University of Turku and Department of Chemical and Process Engineering at Lappeenranta University of Technology. At first, purple-blue potatoes were pretreated in four types of boiled, raw, freeze-dried and dried boiled potato for extraction. They were mixed with aqueous acidified ethanol (ethanol:water:acetic acid 40%:53%:7% v/v) for conventional extraction. Boiled potato was selected as a best pretreated potato. Different ethanol concentration and extraction time were examined and the mixture of 80% in 24 h resulted in maximum anthocyanin content (132.23 mg/L). As conventional extraction method of anthocyanins was non-selective, some of impurities such as free sugars might accelerate anthocyanin degradation. Therefore, to obtain anthocyanins in purified form, adsorption as a promising selective method was used to recovery and isolate anthocyanins. It was carried out with six adsorbents. Among those, Amberlite XAD-7HP, a nonionic acrylic ester adsorbent, was found to have the best performance. In an adsorption column, flow rate of 3 mL/min was selected as the loading flow rate among four tested flow rates. Eluent volume and flow rate were 3 BV of aqueous acidified ethanol (75%, v/v) and 1 mL/min for desorption. The quantification of the total anthocyanin contents was performed by pH-differential method using UV-vis spectrophotometer. The resulting anthocyanin solution after purification was almost free from free sugars which were the major cause for degradation of anthocyanins. The average anthocyanin concentration in the purified and concentrated sample was obtained 1752.89 mg/L.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rare-earth based upconverting nanoparticles (UCNPs) have attracted much attention due to their unique luminescent properties. The ability to convert multiple photons of lower energy to ones with higher energy through an upconversion (UC) process offers a wide range of applications for UCNPs. The emission intensities and wavelengths of UCNPs are important performance characteristics, which determine the appropriate applications. However, insufficient intensities still limit the use of UCNPs; especially the efficient emission of blue and ultraviolet (UV) light via upconversion remains challenging, as these events require three or more near-infrared (NIR) photons. The aim of the study was to enhance the blue and UV upconversion emission intensities of Tm3+ doped NaYF4 nanoparticles and to demonstrate their utility in in vitro diagnostics. As the distance between the sensitizer and the activator significantly affect the energy transfer efficiency, different strategies were explored to change the local symmetry around the doped lanthanides. One important strategy is the intentional co-doping of active (participate in energy transfer) or passive (do not participate in energy transfer) impurities into the host matrix. The roles of doped passive impurities (K+ and Sc3+) in enhancing the blue and UV upconversions, as well as in influencing the intense UV upconversion emission through excess sensitization (active impurity) were studied. Additionally, the effects of both active and passive impurity doping on the morphological and optical performance of UCNPs were investigated. The applicability of UV emitting UCNPs as an internal light source for glucose sensing in a dry chemistry test strip was demonstrated. The measurements were in agreement with the traditional method based on reflectance measurements using an external UV light source. The use of UCNPs in the glucose test strip offers an alternative detection method with advantages such as control signals for minimizing errors and high penetration of the NIR excitation through the blood sample, which gives more freedom for designing the optical setup. In bioimaging, the excitation of the UCNPs in the transparent IR region of the tissue permits measurements, which are free of background fluorescence and have a high signal-to-background ratio. In addition, the narrow emission bandwidth of the UCNPs enables multiplexed detections. An array-in-well immunoassay was developed using two different UC emission colours. The differentiation between different viral infections and the classification of antibody responses were achieved based on both the position and colour of the signal. The study demonstrates the potential of spectral and spatial multiplexing in the imaging based array-in-well assays.