6 resultados para Maximum loading point

em Doria (National Library of Finland DSpace Services) - National Library of Finland, Finland


Relevância:

80.00% 80.00%

Publicador:

Resumo:

The performance of Grid connected Photovoltaic System working with DCBoost stage is investigated. The DC-Boost Converter topology is deduced from three phase half controlled bridge and controlled by Sliding Mode Control. Due to the fact that Grid connected Photovoltaic System includes Solar cells as a DC source and inverter for grid connection, those are under the scope of this research as well. The advantages of using MPPT are analyzed. The system is simulated in Matlab-Simulink™ environment.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Työssä selvitetään mallipohjaisen suunnittelun ja simulointimallista tuotetun ohjelmakoodin kelpoisuutta tuotekehityskäytössä. Työtapoja tutkitaan, koska halutaan selvittää parantavatko esitetyt toimintatavat aurinkosähkövaihtosuuntaajien ohjelmistokehitystä. Työssä käydään läpi mallipohjaisen suunnittelun työvaiheet, niiden sisältö ja tarkoitus. Aurinkosähköjärjestelmästä muodostetaan simulointimalli, josta tuotetaan maksimitehopisteseuraajan ohjelmakoodi, jonka toiminta testataan aurinkosähkövaihtosuuntaajan ohjausalustan simulaattorissa. Mallipohjainen suunnittelu mahdollistaa ohjelmistotuotekehityksen nopeuttamisen käyttämällä samaa järjestelmää useassa työvaiheessa. Ohjelmakoodin tuottaminen simulointimallista on mahdollista ja hyödyllistä, jos yrityksessä käytetään simulointitestausta säätö- ja ohjausjärjestelmän toiminnan suunnitteluun ja varmentamiseen.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Työssä tutkittiin kirjallisuuden ja laboratoriomittausten avulla vaihtoehtoja kullan pelkistämiseen ja talteenottoon kultauuton takaisinuuttoliuoksista. Tavoitteena oli löytää menetelmä, jolla saadaan puhdasta kiinteää lopputuotetta ilman kullan häviöitä. Käytettyjä pelkistimiä olivat D-(+)-glukoosi, natriumboorihydridi, L-askorbiinihappo, D-(-)-isoaskorbiinihappo ja aktiivihiili. Laboratoriokokeiden perusteella D-(-)-isoaskorbiinihappo sekä aktiivihiili olivat sopivimmat pelkistimet kokeissa käytetylle kultaliuokselle. Isoaskorbiinihapolla suoritettiin panoskokeita lasireaktorissa eri alku-pH:ssa sekä erilaisilla pelkistimen ja kullan moolisuhteilla. Tulosten perusteella havaittiin pH:n ja pelkistimen ylimäärän vaikuttavan merkittävästi lopputuotteen puhtauteen. Myös redox-potentiaalia säätämällä ja happopesulla pelkistyksen jälkeen voidaan vaikuttaa lopputuotteen puhtauteen. Aktiivihiilellä suoritettiin panoskokeita adsorptiotasapainojen (latausisotermi) ja kinetiikan tutkimiseksi. Hiileen on mahdollista saada kultaa 383 mg/g kuivaa hiiltä. Suurempi lataus voitaisiin saavuttaa käyttämällä hiiltä, jolla on pienempi partikkelikoko. Kolonnikokeita tehtiin eri virtausnopeuksilla. Kolonnikokeissa kullan dynaaminen adsorptiokapasiteetti hiileen odotetusti kasvoi virtausnopeuden laskiessa. Pienin käytetty virtausnopeus oli 2,40 BV/h, jolloin kapasiteetti oli 75,4 mg/g kuivaa hiiltä (c (Au feed) = 129 mg/L). Kullasta voidaan poistaa myös kolonnipelkistyksen jälkeen epäpuhtauksia happopesulla. Isoaskorbiinihapolla pelkistyksen kinetiikka on nopea ja sillä saatiin pelkistettyä puhdasta lopputuotetta. Sekä isoaskorbiinihappo, että aktiivihiili ovat potentiaalisia menetelmiä kullan talteenottoon.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Porous silicon (PSi) is a promising material to be utilized in drug delivery formulations. The release rate of the drug compound can be controlled by changing the pore properties and surface chemistry of PSi. The loading of a poorly soluble drug into mesoporous silicon particles enhances its dissolution in the body. The drug loading is based on adsorption. The attainable maximum loaded amount depends on the properties of the drug compound and the PSi material, and on the process conditions. The loading solvent also essentially affects the adsorption process. The loading of indomethacin into PSi particles with varying surface modification was studied. Solvent mixtures were applied in the loading, and the loaded samples were analyzed with thermal analysis methods. The best degree of loading was obtained using a mixture of dichloromethane and methanol. The drug loads varied from 7.7 w-% to 26.8 w-%. A disturbing factor in the loading experiments was the tendency of indomethacin to form solvates with the solvents applied. In addition, the physical form and stability of indomethacin loaded in PSi and silica particles were studied using Raman spectroscopy. In the case of silica, the presence of crystalline drug as well as the polymorph form can be detected, but the method proved to be not applicable for PSi particles.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this thesis is to investigate the thermal loading of medium voltage three-level NPC inverter’s semiconductor IGCT switches in different operation points. The objective is to reach both a fairly accurate off-line simulation program and also so simple a simulation model that its implementation into an embedded system could be reasonable in practice and a real time use should become feasible. Active loading limitation of the inverter can be realized with a thermal model which is practical in a real time use. Determining of the component heating has been divided into two parts; defining of component losses and establishing the structure of a thermal network. Basics of both parts are clarified. The simulation environment is Matlab-Simulink. Two different models are constructed – a more accurate one and a simplified one. Potential simplifications are clarified with the help of the first one. Simplifications are included in the latter model and the functionalities of both models are compared. When increasing the calculation time step a decreased number of considered components and time constants of the thermal network can be used in the simplified model. Heating of a switching component is dependent on its topological position and inverter’s operation point. The output frequency of the converter defines mainly which one of the switching components is – because of its losses and heating – the performance limiting component of the converter. Comparison of results given by different thermal models demonstrates that with larger time steps, describing of fast occurring switching losses becomes difficult. Generally articles and papers dealing with this subject are written for two-level inverters. Also inverters which apply direct torque control (DTC) are investigated rarely from the heating point of view. Hence, this thesis completes the former material.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In the current economy situation companies try to reduce their expenses. One of the solutions is to improve the energy efficiency of the processes. It is known that the energy consumption of pumping applications range from 20 up to 50% of the energy usage in the certain industrial plants operations. Some studies have shown that 30% to 50% of energy consumed by pump systems could be saved by changing the pump or the flow control method. The aim of this thesis is to create a mobile measurement system that can calculate a working point position of a pump drive. This information can be used to determine the efficiency of the pump drive operation and to develop a solution to bring pump’s efficiency to a maximum possible value. This can allow a great reduction in the pump drive’s life cycle cost. In the first part of the thesis, a brief introduction in the details of pump drive operation is given. Methods that can be used in the project are presented. Later, the review of available platforms for the project implementation is given. In the second part of the thesis, components of the project are presented. Detailed description for each created component is given. Finally, results of laboratory tests are presented. Acquired results are compared and analyzed. In addition, the operation of created system is analyzed and suggestions for the future development are given.