11 resultados para Ionizing radiation

em Doria (National Library of Finland DSpace Services) - National Library of Finland, Finland


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Salivary gland cancer (SGC) is a rare cancer. The histological classification of SGC is complex and its biological behavior highly variable: it may vary from a low-grade tumor to a high-grade and often fatal malignancy. These circumstances make this cancer a diagnostic and therapeutic challenge. Older age and exposure to ionizing radiation are known risk factors. The mainstay of treatment is surgery combined with adjuvant radiation therapy, when appropriate. In addition to the histological type, the only well known prognostic factor is the TNM classification, which describes the tumor size and the amount of metastases. This study was performed using a full population-based nationwide cohort of SGC patients and tumors diagnosed in Finland in 1991-1996. The annual incidence of SGC in the entire population was, on average, 47.7 per year. By histological re-evaluation of 237 specimens the most frequent histological types were the adenoid cystic carcinoma (n=65; 27%), the mucoepidermoid carcinoma (n=45; 19%) and the acinic cell carcinoma (n=41; 17%). The highest 10-year disease-specific survival rate occurred among patients with acinic cell carcinoma (90%), followed by mucoepidermoid carcinoma (81%) and adenoid cystic carcinoma (60%). A high volume-corrected index (VCI) of Ki-67 correlated with worse survival of patients with SGC. Computer-assisted morphometric analyses of CD34-positive vessels indicated an unfavorable prognosis for patients with mucoepidermoid carcinoma and an association with poor survival among patients with acinic cell carcinoma. A high level of expression of matrix metalloproteinase-9 (MMP-9) showed a trend for a poorer prognosis in salivary duct carcinoma, and a high level of MMP-13 and a low level of MMP-1 had a trend for a poorer prognosis of patients with SGC. A low level of MMP-7 was associated with a poor prognosis of patients with acinic cell and mucoepidermoid carcinoma.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Ydinvoimalaitosten vesikemian optimointi ja korroosionesto on välttämätöntä laitosten taloudellisen ja turvallisen käytön kannalta. Eri laitoksiin liittyvää vesikemiaa ja järjestelmissä havaittavia korroosion muotoja on tutkittu laajasti ja tutkitaan yhä edelleen. Monien prosessien ymmärtäminen vaatii usean eri tieteenalan osaamista, kuten kemiantekniikan, energiatekniikan sekä materiaalitekniikan. Tässä työssä kerrotaan yksinkertaistaen vesikemiaan ja korroosioon liittyviä prosesseja ja reaktioita. Työssä käsitellään kevytvettä jäähdytteenä sekä moderaattorina käyttävien ydinvoimalaitosten eri korroosiomuotoja sekä säteilyn vaikutusta näihin suoraan tai vesikemian kautta. Työssä kerrotaan korroosio- ja aktivoitumistuotteiden muodostumisesta ja kulkeutumisesta sekä näiden tuotteiden vaikutuksista laitosten toimintaan. Korroosion ja materiaalien aktivoitumisen pohjalta tarkastellaan kattavasti ydinvoimalaitosten tyypillisimpiä vesikemian muokkauskeinoja sekä korroosionhallintaa. Tärkeimpiin asioihin syvennytään hieman lähemmin. Tarkastelun kohteena ovat eniten käytetyt ydinvoimalaitokset, eli länsimaiset paine- ja kiehutusvesilaitokset sekä venäläisvalmisteiset VVER-laitokset. Tarkoituksena on ollut luoda tiivis tietopaketti opiskelijoiden käyttöön muun opintomateriaalin tueksi.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Olkiluodon ja Loviisan ydinvoimalaitoksilla syntyvä käytetty ydinpolttoaine tullaan kapseloimaan ja loppusijoittamaan Posiva Oy:n kapselointi- ja loppusijoituslaitoksella, joka rakennetaan Olkiluotoon. Käytetyn polttoaineen käsittelyssä on huomioitava säteilytyöhön liittyviä säteilysuojelunäkökohtia. Kapseloinnissa ja loppusijoituksessa käsitellään vaarallisia säteilylähteitä, joista merkittävimmät ovat käytetty ydinpolttoaine ja täyden loppusijoituskapselin röntgentarkastuslaitteisto. Posivan laitosten käyttötoiminnalle muodostetaan tässä diplomityössä säteilysuojelun vaatimusmäärittely. Kapseloinnin ja loppusijoituksen säteilytyövaiheet käsitellään yksitellen säteilysuojelun näkökulmasta. Työvaiheille määritetään tarpeelliset säteilysuojelutoimenpiteet ja työvaiheiden suorittamisen säteilysuojeluvaatimukset. Molempien laitosten valvonta-aluejärjestelyjä ja säteilyolosuhteiden vyöhykejakoa tarkennetaan. Työssä määritetään vyöhyke- ja aluerajoilla vaadittavat säteilysuojelutoiminnot sekä kontaminaationhallinnan laatuvaatimukset. Työssä käsitellään myös operatiivisen säteilysuojelun toimenpiteiden laatuvaatimuksia ja tarvittavaa säteilysuojelun sisäistä ohjeistoa. Työn tuloksena on kapselointi- ja loppusijoituslaitoksen käyttötoiminnan operatiivisten säteilysuojelutoimenpiteiden kuvaus. Kapselointi- ja loppusijoituslaitosten säteilysuojelua toteutetaan käyttövaiheen työnsuunnittelulla, operatiivisilla säteilysuojelutoimilla ja rakenteellisin keinoin. Työntekijöiden säteilyannokset minimoidaan välttämällä oleskelua kohonneen säteilytason alueilla. Kapselin röntgentarkastuslaitteiston käytön säteilyturvallisuus on varmistettava ja laitosten käyttötoiminta ei saa aiheuttaa työntekijöille sisäistä säteilyannosta. Useista työvaiheista ja käyttötoiminnan poikkeustilanteista on tehtävä jatkoanalyyseja työntekijöiden säteilysuojelun näkökulmasta.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The research on the interaction between radiation and biomolecules pro-vides valuable information for both radiobiology and molecular physics. While radiobiology is interested in the damage inflicted on the molecule upon irradiation, molecular physics exploits these studies to obtain infor-mation about the physical properties of the molecule and the quantum me-chanical processes involved in the interaction. This thesis work investigated how a small change in the structure or composition of a biomolecule changes the response of the molecule to ioniz-ing radiation. Altogether eight different biomolecules were studied: nucleo-sides uridine, 5-methyluridine and thymidine; amino acids alanine, cysteine and serine; and halogenated acetic acids chloro- and bromoacetic acids. The effect of ionizing radiation on these molecules was studied on molecular level, investigating the samples in gas phase. Synchrotron radiation of VUV or soft x-ray range was used to ionize sample molecules, and the subsequent fragmentation processes were investigated with ion mass spectroscopy and ion-ion-electron coincidence spectroscopy. The comparison between the three nucleosides revealed that adding or removing a single functional group can affect not only the bonds from which the molecule ruptures upon ionization but also the charge localiza-tion in the formed fragments. Studies on amino acids and halogenated acetic acids indicated that one simple substitution in the molecule can dramatical-ly change the extent of fragmentation. This thesis work also demonstrates that in order to steer the radiation-induced fragmentation of the molecules, it is not always necessary to alter the amount of energy deposited on the molecules but selecting a suitable substitution may suffice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis describes the development of advanced silicon radiation detectors and their characterization by simulations, used in the work for searching elementary particles in the European Organization for Nuclear Research, CERN. Silicon particle detectors will face extremely harsh radiation in the proposed upgrade of the Large Hadron Collider, the future high-energy physics experiment Super-LHC. The increase in the maximal fluence and the beam luminosity up to 1016 neq / cm2 and 1035 cm-2s-1 will require detectors with a dramatic improvement in radiation hardness, when such a fluence will be far beyond the operational limits of the present silicon detectors. The main goals of detector development concentrate on minimizing the radiation degradation. This study contributes mainly to the device engineering technology for developing more radiation hard particle detectors with better characteristics. Also the defect engineering technology is discussed. In the nearest region of the beam in Super-LHC, the only detector choice is 3D detectors, or alternatively replacing other types of detectors every two years. The interest in the 3D silicon detectors is continuously growing because of their many advantages as compared to conventional planar detectors: the devices can be fully depleted at low bias voltages, the speed of the charge collection is high, and the collection distances are about one order of magnitude less than those of planar technology strip and pixel detectors with electrodes limited to the detector surface. Also the 3D detectors exhibit high radiation tolerance, and thus the ability of the silicon detectors to operate after irradiation is increased. Two parameters, full depletion voltage and electric field distribution, is discussed in more detail in this study. The full depletion of the detector is important because the only depleted area in the detector is active for the particle tracking. Similarly, the high electric field in the detector makes the detector volume sensitive, while low-field areas are non-sensitive to particles. This study shows the simulation results of full depletion voltage and the electric field distribution for the various types of 3D detectors. First, the 3D detector with the n-type substrate and partial-penetrating p-type electrodes are researched. A detector of this type has a low electric field on the pixel side and it suffers from type inversion. Next, the substrate is changed to p-type and the detectors having electrodes with one doping type and the dual doping type are examined. The electric field profile in a dual-column 3D Si detector is more uniform than that in the single-type column 3D detector. The dual-column detectors are the best in radiation hardness because of their low depletion voltages and short drift distances.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of the work was to realize a high-speed digital data transfer system for RPC muon chambers in the CMS experiment on CERN’s new LHC accelerator. This large scale system took many years and many stages of prototyping to develop, and required the participation of tens of people. The system interfaces to Frontend Boards (FEB) at the 200,000-channel detector and to the trigger and readout electronics in the control room of the experiment. The distance between these two is about 80 metres and the speed required for the optic links was pushing the limits of available technology when the project was started. Here, as in many other aspects of the design, it was assumed that the features of readily available commercial components would develop in the course of the design work, just as they did. By choosing a high speed it was possible to multiplex the data from some the chambers into the same fibres to reduce the number of links needed. Further reduction was achieved by employing zero suppression and data compression, and a total of only 660 optical links were needed. Another requirement, which conflicted somewhat with choosing the components a late as possible was that the design needed to be radiation tolerant to an ionizing dose of 100 Gy and to a have a moderate tolerance to Single Event Effects (SEEs). This required some radiation test campaigns, and eventually led to ASICs being chosen for some of the critical parts. The system was made to be as reconfigurable as possible. The reconfiguration needs to be done from a distance as the electronics is not accessible except for some short and rare service breaks once the accelerator starts running. Therefore reconfigurable logic is extensively used, and the firmware development for the FPGAs constituted a sizable part of the work. Some special techniques needed to be used there too, to achieve the required radiation tolerance. The system has been demonstrated to work in several laboratory and beam tests, and now we are waiting to see it in action when the LHC will start running in the autumn 2008.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Planar, large area, position sensitive silicon detectors are widely utilized in high energy physics research and in medical, computed tomography (CT). This thesis describes author's research work relating to development of such detector components. The key motivation and objective for the research work has been the development of novel, position sensitive detectors improving the performance of the instruments they are intended for. Silicon strip detectors are the key components of barrel-shaped tracking instruments which are typically the innermost structures of high energy physics experimental stations. Particle colliders such as the former LEP collider or present LHC produce particle collisions and the silicon strip detector based trackers locate the trajectories of particles emanating from such collisions. Medical CT has become a regular part of everyday medical care in all developed countries. CT scanning enables x-ray imaging of all parts of the human body with an outstanding structural resolution and contrast. Brain, chest and abdomen slice images with a resolution of 0.5 mm are possible and latest CT machines are able to image whole human heart between heart beats. The two application areas are presented shortly and the radiation detection properties of planar silicon detectors are discussed. Fabrication methods and preamplifier electronics of the planar detectors are presented. Designs of the developed, large area silicon detectors are presented and measurement results of the key operating parameters are discussed. Static and dynamic performance of the developed silicon strip detectors are shown to be very satisfactory for experimental physics applications. Results relating to the developed, novel CT detector chips are found to be very promising for further development and all key performance goals are met.