3 resultados para Instabilidade articular

em Doria (National Library of Finland DSpace Services) - National Library of Finland, Finland


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Summary: Medical treatment of osteoarthritis in the horse. Part 1, intra-articular treatment

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Radiostereometric analysis (RSA) is a highly accurate method for the measurement of in vivo micromotion of orthopaedic implants. Validation of the RSA method is a prerequisite for performing clinical RSA studies. Only a limited number of studies have utilised the RSA method in the evaluation of migration and inducible micromotion during fracture healing. Volar plate fixation of distal radial fractures has increased in popularity. There is still very little prospective randomised evidence supporting the use of these implants over other treatments. The aim of this study was to investigate the precision, accuracy, and feasibility of using RSA in the evaluation of healing in distal radius fractures treated with a volar fixed-angle plate. A physical phantom model was used to validate the RSA method for simple distal radius fractures. A computer simulation model was then used to validate the RSA method for more complex interfragmentary motion in intra-articular fractures. A separate pre-clinical investigation was performed in order to evaluate the possibility of using novel resorbable markers for RSA. Based on the validation studies, a prospective RSA cohort study of fifteen patients with plated AO type-C distal radius fractures with a 1-year follow-up was performed. RSA was shown to be highly accurate and precise in the measurement of fracture micromotion using both physical and computer simulated models of distal radius fractures. Resorbable RSA markers demonstrated potential for use in RSA. The RSA method was found to have a high clinical precision. The fractures underwent significant translational and rotational migration during the first two weeks after surgery, but not thereafter. Maximal grip caused significant translational and rotational interfragmentary micromotion. This inducible micromotion was detectable up to eighteen weeks, even after the achievement of radiographic union. The application of RSA in the measurement of fracture fragment migration and inducible interfragmentary micromotion in AO type-C distal radius fractures is feasible but technically demanding. RSA may be a unique tool in defining the progress of fracture union.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Large-headed total hip arthroplasty (THA) and hip resurfacing arthroplasty (HRA) with metal-on-metal (MoM) bearings became popular during the last decade. Recently, it has become evident that the large-head MoM hip implants are associated with increased revision rates despite their theoretical advantages. The purpose of this study was to evaluate the early results of primary MoM hip replacements and of acetabular revisions. I analyzed retrospectively the results of four MoM implant designs and the survival rate of acetabular revisions with impaction bone grafting, as documented in the Turku University Hospital database. Further, I evaluated the correlation between femoral head size and dislocation rate, and used the Finnish Arthroplasty Register data to compare the survival of three large-head MoM THAs to analogous HRAs. The early results for the Magnum M2A–ReCap THA were good. A larger head size decreased the risk of dislocation. Articular surface replacement (ASR) THA yielded inferior results compared to analogous HRA. For two other designs the results were similar. The R3–Synergy THA yielded inferior results compared to the reference implants. The survival of acetabular reconstructions with impaction bone grafting was inferior compared to previous reports. In conclusion, the early results of the Biomet ReCap–Magnum design were promising, and large head sizes decreased the dislocation rate. The survival of different MoM hip implant designs varied. The survival of new designs and techniques may be inferior to those reported by the clinics where implants are developed. An important caveat is that early promising results of new devices may rapidly worsen. New implants need to be introduced in a controlled fashion to the market; here, arthroplasty registers are a valuable tool that needs to be used.