13 resultados para High-angular resolution diffusion imaging
em Doria (National Library of Finland DSpace Services) - National Library of Finland, Finland
Resumo:
In this dissertation, active galactic nuclei (AGN) are discussed, as they are seen with the high-resolution radio-astronomical technique called Very Long Baseline Interferometry (VLBI). This observational technique provides very high angular resolution (_ 10−300 = 1 milliarcsecond). VLBI observations, performed at different radio frequencies (multi-frequency VLBI), allow to penetrate deep into the core of an AGN to reveal an otherwise obscured inner part of the jet and the vicinity of the AGN’s central engine. Multi-frequency VLBI data are used to scrutinize the structure and evolution of the jet, as well as the distribution of the polarized emission. These data can help to derive the properties of the plasma and the magnetic field, and to provide constraints to the jet composition and the parameters of emission mechanisms. Also VLBI data can be used for testing the possible physical processes in the jet by comparing observational results with results of numerical simulations. The work presented in this thesis contributes to different aspects of AGN physics studies, as well as to the methodology of VLBI data reduction. In particular, Paper I reports evidence of optical and radio emission of AGN coming from the same region in the inner jet. This result was obtained via simultaneous observations of linear polarization in the optical and in radio using VLBI technique of a sample of AGN. Papers II and III describe, in detail, the jet kinematics of the blazar 0716+714, based on multi-frequency data, and reveal a peculiar kinematic pattern: plasma in the inner jet appears to move substantially faster that that in the large-scale jet. This peculiarity is explained by the jet bending, in Paper III. Also, Paper III presents a test of the new imaging technique for VLBI data, the Generalized Maximum Entropy Method (GMEM), with the observed (not simulated) data and compares its results with the conventional imaging. Papers IV and V report the results of observations of the circularly polarized (CP) emission in AGN at small spatial scales. In particular, Paper IV presents values of the core CP for 41 AGN at 15, 22 and 43 GHz, obtained with the help of the standard Gain transfer (GT) method, which was previously developed by D. Homan and J.Wardle for the calibration of multi-source VLBI observations. This method was developed for long multi-source observations, when many AGN are observed in a single VLBI run. In contrast, in Paper V, an attempt is made to apply the GT method to single-source VLBI observations. In such observations, the object list would include only a few sources: a target source and two or three calibrators, and it lasts much shorter than the multi-source experiment. For the CP calibration of a single-source observation, it is necessary to have a source with zero or known CP as one of the calibrators. If the archival observations included such a source to the list of calibrators, the GT could also be used for the archival data, increasing a list of known AGN with the CP at small spatial scale. Paper V contains also calculation of contributions of different sourced of errors to the uncertainty of the final result, and presents the first results for the blazar 0716+714.
Resumo:
Lanthanum lutetium oxide (LaLuO3) thin films were investigated considering their perspective application for industrial microelectronics. Scanning probe microscopy (SPM) techniques permitted to visualize the surface topography and study the electric properties. This work compared both the material properties (charge behavior for samples of 6 nm and 25 nm width) and the applied SPM modes. Particularly, Kelvin probe force microscopy (KPFM) was applied to characterize local potential difference with high lateral resolution. Measurements showed the difference in morphology, chargeability and charge dissipation time for both samples. The polarity effect was detected for this material for the first time. Lateral spreading of the charged spots indicate the diffusive mechanism to be predominant in charge dissipation. This allowed to estimate the diffusion coefficient and mobility. Using simple electrostatic model it was found that charge is partly leaking into the interface oxide layer.
Resumo:
Optical microscopy is living its renaissance. The diffraction limit, although still physically true, plays a minor role in the achievable resolution in far-field fluorescence microscopy. Super-resolution techniques enable fluorescence microscopy at nearly molecular resolution. Modern (super-resolution) microscopy methods rely strongly on software. Software tools are needed all the way from data acquisition, data storage, image reconstruction, restoration and alignment, to quantitative image analysis and image visualization. These tools play a key role in all aspects of microscopy today – and their importance in the coming years is certainly going to increase, when microscopy little-by-little transitions from single cells into more complex and even living model systems. In this thesis, a series of bioimage informatics software tools are introduced for STED super-resolution microscopy. Tomographic reconstruction software, coupled with a novel image acquisition method STED< is shown to enable axial (3D) super-resolution imaging in a standard 2D-STED microscope. Software tools are introduced for STED super-resolution correlative imaging with transmission electron microscopes or atomic force microscopes. A novel method for automatically ranking image quality within microscope image datasets is introduced, and it is utilized to for example select the best images in a STED microscope image dataset.
Resumo:
In machine design we always want to save space, save energy and produce as much power as possible. We can often reduce accelerations, inertial loads and energy consumption by changing construction. In this study the old cardan gear mechanism (hypocycloid mechanism) has been compared with the conventional slider-crank mechanism in air pumps and four-stroke engines. Comprehensive Newtonian dynamics has been derived for the both mechanisms. First the slidercrank and the cardan gear machines have been studied as lossless systems. Then the friction losses have been added to the calculations. The calculation results show that the cardan gear machines can be more efficient than the slider-crank machines. The smooth running, low mass inertia, high pressures and small frictional power losses make the cardan gear machines clearly better than the slider-crank machines. The dynamic tooth loads of the original cardan gear construction do not rise very high when the tooth clearances are kept tight. On the other hand the half-size crank length causes high bearing forces in the cardan gear machines. The friction losses of the cardan gear machines are generally quite small. The mechanical efficiencies are much higher in the cardan gear machines than in the slider-crank machines in normal use. Crankshaft torques and power needs are smaller in the cardan gear air pumps than in the equal slider-crank air pumps. The mean crankshaft torque and the mean output power are higher in the cardan gear four-stroke engines than in the slider-crank four-stroke engines in normal use. The cardan gear mechanism is at its best, when we want to build a pump or an engine with a long connecting rod (≈ 5⋅crank length) and a thin piston (≈ 1.5⋅crank length) rotating at high angular velocity and intermittently high angular acceleration. The cardan gear machines can be designed also as slide constructions without gears. Suitable applications of the cardan gear machines are three-cylinder half-radial engines for motorcycles, sixcylinder radial engines for airplanes and six-cylinder double half-radial engines for sport cars. The applied equations of Newtonian dynamics, comparative calculations, calculation results (tables, curves and surface plots) and recommendations presented in this study hold novelty value and are unpublished before. They have been made and written by the author first time in this study.
Resumo:
Tämä työ on kirjallisuuskatsaus digitaalisen teräväpiirtoresoluution historiaan, nykyhetkeen ja tulevaisuuteen. Lisäksi käydään läpi eri medioista löytyviä termejä ja pyritään selvittämään näiden termien merkitys lukijalle. Työ on tehty Lappeenrannan teknillisen yliopiston Tietotekniikan osastolle. Teräväpiirtotelevision historia alkaa jo 1960-luvulta ja ensimmäiset teräväpiirtoresoluutiot kehitettiin 1970-luvulla. Kun resoluutiota kasvatetaan, myös kuvatiedoston ja vaadittavan tallennustilan koko kasvaa. Se aiheuttaa uusia haasteita muun muassa lähetys-, pakkaus- ja vastaanotintekniikoille. 4K-resoluutiot ovat jo täällä, mutta miten käy 16K-resoluution. Onko suuresta resoluutiosta hyötyä esimerkiksi Virtual Reality –sovelluksissa?
Resumo:
PhotoAcoustic Imaging (PAI) is a branch in clinical and pre-clinical imaging, that refers to the techniques mapping acoustic signals caused by the absorption of the short laser pulse. This conversion of electromagnetic energy of the light to the mechanical (acoustic) energy is usually called photoacoustic effect. PAI, by combining optical excitation with acoustical detection, is able to preserve the diffraction limited spatial resolution. At the same time, the penetration depth is extended beyond the diffusive limit. The Laser-Scanning PhotoAcoustic Microscope system (LS-PAM) has been developed, that offers the axial resolution of 7.75 µm with the lateral resolution better than 10 µm. The first in vivo imaging experiments were carried out. Thus, in vivo label-free imaging of the mouse ear was performed. The principle possibility to image vessels located in deep layers of the mouse skin was shown. As well as that, a gold printing sample, vasculature of the Chick Chorioallantoic Membrane Assay, Drosophila larvae were imaged by PAI. During the experimental work, a totally new application of PAM was found, in which the acoustic waves, generated by incident light can be used for further imaging of another sample. In order to enhance the performance of the presented system two main recommendation can be offered. First, the current system should be transformed into reflection-mode setup system. Second, a more powerful source of light with the sufficient repetition rate should be introduced into the system.
Resumo:
The human striatum is a heterogeneous structure representing a major part of the dopamine (DA) system’s basal ganglia input and output. Positron emission tomography (PET) is a powerful tool for imaging DA neurotransmission. However, PET measurements suffer from bias caused by the low spatial resolution, especially when imaging small, D2/3 -rich structures such as the ventral striatum (VST). The brain dedicated high-resolution PET scanner, ECAT HRRT (Siemens Medical Solutions, Knoxville, TN, USA) has superior resolution capabilities than its predecessors. In the quantification of striatal D2/3 binding, the in vivo highly selective D2/3 antagonist [11C] raclopride is recognized as a well-validated tracer. The aim of this thesis was to use a traditional test-retest setting to evaluate the feasibility of utilizing the HRRT scanner for exploring not only small brain regions such as the VST but also low density D2/3 areas such as cortex. It was demonstrated that the measurement of striatal D2/3 binding was very reliable, even when studying small brain structures or prolonging the scanning interval. Furthermore, the cortical test-retest parameters displayed good to moderate reproducibility. For the first time in vivo, it was revealed that there are significant divergent rostrocaudal gradients of [11C]raclopride binding in striatal subregions. These results indicate that high-resolution [11C]raclopride PET is very reliable and its improved sensitivity means that it should be possible to detect the often very subtle changes occurring in DA transmission. Another major advantage is the possibility to measure simultaneously striatal and cortical areas. The divergent gradients of D2/3 binding may have functional significance and the average distribution binding could serve as the basis for a future database. Key words: dopamine, PET, HRRT, [11C]raclopride, striatum, VST, gradients, test-retest.
Resumo:
Convective transport, both pure and combined with diffusion and reaction, can be observed in a wide range of physical and industrial applications, such as heat and mass transfer, crystal growth or biomechanics. The numerical approximation of this class of problemscan present substantial difficulties clue to regions of high gradients (steep fronts) of the solution, where generation of spurious oscillations or smearing should be precluded. This work is devoted to the development of an efficient numerical technique to deal with pure linear convection and convection-dominated problems in the frame-work of convection-diffusion-reaction systems. The particle transport method, developed in this study, is based on using rneshless numerical particles which carry out the solution along the characteristics defining the convective transport. The resolution of steep fronts of the solution is controlled by a special spacial adaptivity procedure. The serni-Lagrangian particle transport method uses an Eulerian fixed grid to represent the solution. In the case of convection-diffusion-reaction problems, the method is combined with diffusion and reaction solvers within an operator splitting approach. To transfer the solution from the particle set onto the grid, a fast monotone projection technique is designed. Our numerical results confirm that the method has a spacial accuracy of the second order and can be faster than typical grid-based methods of the same order; for pure linear convection problems the method demonstrates optimal linear complexity. The method works on structured and unstructured meshes, demonstrating a high-resolution property in the regions of steep fronts of the solution. Moreover, the particle transport method can be successfully used for the numerical simulation of the real-life problems in, for example, chemical engineering.
Resumo:
Lähikenttä- ja kaukokenttämikroskopian yhdistäminen: Uusi korkearesoluutioinen menetelmä nanokuvantamiseen. Osteoporoosi on sairaus, jossa luun uudistumisprosessi ei ole enää tasapainossa. Uuden luun muodostuminen on hitaampaa johtuen osteoblastien laskeneesta aktiivisuudesta. Yksi keino estää osteoporoosin syntyä on estää osteoklastien sitoutuminen luun pinnalle, jolloin ne eivät aloita luun syömisprosessia. Tämän Pro gradu -tutkielman tarkoituksena on luoda uusi työkalu osteoklastien sitoutumisen tutkimiseen samanaikaisesti fluoresenssi- ja atomivoimamikroskoopilla. Tätä tarkoitusta varten yhdistettiin atomivoimamikroskooppi sekä STED mikroskooppi. Kirjallisuuskatsauksessa käydään läpi yksityiskohtaisesti molempien mikroskooppitekniikoiden teoriat. Kokeellisessa osiossa esitetään käytetyt metodit ja alustavat tulokset uudella systeemillä. Lisäksi keskustellaan lyhyesti kuvan analysoinnista ImageJohjelmalla. Konfokaalisen fluoresenssimikroskoopin ja atomivoimamikroskoopin yhdistelmä on keksitty jo aikaisemmin, mutta tavallisen konfokaalimikroskoopin erottelukyvyn raja on noin 200 nanometriä johtuen valon diffraktioluonteesta. Yksityiskohdat eivät erotu, jos ne ovat pienempiä kuin puolet käytettävästä aallonpituudesta. STED mikroskooppi mahdollistaa fluoresenssikuvien taltioimisen solunsisäisistä prosesseista 50 nanometrin lateraalisella erotuskyvyllä ja atomivoimamikroskooppi antaa topografista tietoa näytteestä nanometrien erotuskyvyllä. Biologisia näytteitä kuvannettaessa atomivoimamikroskoopin erotuskyky kuitenkin huononee ja yleensä saavutetaan 30-50 nanometrin erotuskyky. Kuvien kerrostaminen vaatii vertauspisteitä ja tätä varten käytettiin atomivoimamikroskoopin kärjen tunnistamista ja referenssipartikkeleita. Kuva-analysointi suoritettiin ImageJ-kuvankäsittelyohjelmalla. Tuloksista nähdään, että referenssipartikkelit ovat hyviä, mutta niiden sijoittaminen tarkasti tietylle kohdealueelle on hankalaa nanoskaalassa. Tästä johtuen kärjen havaitseminen fluoresenssikuvassa on parempi metodi. Atomivoimamikroskoopin kärki voidaan päällystää fluoresoivalla aineella, mutta tämä lisää kärjen aiheuttamaa konvoluutiota mittausdataan. Myös valon takaisinsirontaa kärjestä voidaan tutkia, jolloin konvoluutio ei lisäänny. Ensimmäisten kuvien kerrostamisessa käytettiin hyväksi fluoresoivalla aineella päällystettyä kärkeä ja lopputuloksessa oli vain 50 nanometrin yhteensopimattomuus fluoresenssi- ja topografiakuvan kanssa. STED mikroskoopin avulla nähdään leimattujen proteiinien tarkat sijainnit tiettynä ajankohtana elävän solun sisällä. Samaan aikaan pystytään kuvantamaan solun fyysisiä muotoja tai mitata adheesiovoimia atomivoimamikroskoopilla. Lisäksi voidaan käyttää funktinalisoitua kärkeä, jolla voidaan laukaista signalointitapahtumia solun ja soluväliaineen välillä. Sitoutuminen soluväliaineeseen voidaan rekisteröidä samoin kuin adheesiomediaattorien sijainnit sitoutumisalueella. Nämä dynaamiset havainnot tuottavat uutta informaatiota solun signaloinnista, kun osteoklasti kiinnittyy luun pintaan. Tämä teknologia tarjoaa uuden näkökulman monimutkaisiin signalointiprosesseihin nanoskaalassa ja tulee ratkaisemaan lukemattoman määrän biologisia ongelmia.
Resumo:
Background: Approximately two percent of Finns have sequels after traumatic brain injury (TBI), and many TBI patients are young or middle-aged. The high rate of unemployment after TBI has major economic consequences for society, and traumatic brain injury often has remarkable personal consequences, as well. Structural imaging is often needed to support the clinical TBI diagnosis. Accurate early diagnosis is essential for successful rehabilition and, thus, may also influence the patient’s outcome. Traumatic axonal injury and cortical contusions constitute the majority of traumatic brain lesions. Several studies have shown magnetic resonance imaging (MRI) to be superior to computed tomography (CT) in the detection of these lesions. However, traumatic brain injury often leads to persistent symptoms even in cases with few or no findings in conventional MRI. Aims and methods: The aim of this prospective study was to clarify the role of conventional MRI in the imaging of traumatic brain injury, and to investigate how to improve the radiologic diagnostics of TBI by using more modern diffusion-weighted imaging (DWI) and diffusion tensor imaging (DTI) techniques. We estimated, in a longitudinal study, the visibility of the contusions and other intraparenchymal lesions in conventional MRI at one week and one year after TBI. We used DWI-based measurements to look for changes in the diffusivity of the normal-appearing brain in a case-control study. DTI-based tractography was used in a case-control study to evaluate changes in the volume, diffusivity, and anisotropy of the long association tracts in symptomatic TBI patients with no visible signs of intracranial or intraparenchymal abnormalities on routine MRI. We further studied the reproducibility of different tools to identify and measure white-matter tracts by using a DTI sequence suitable for clinical protocols. Results: Both the number and extent of visible traumatic lesions on conventional MRI diminished significantly with time. Slightly increased diffusion in the normal-appearing brain was a common finding at one week after TBI, but it was not significantly associated with the injury severity. Fractional anisotropy values, that represent the integrity of the white-matter tracts, were significantly diminished in several tracts in TBI patients compared to the control subjects. Compared to the cross-sectional ROI method, the tract-based analyses had better reproducibility to identify and measure white-matter tracts of interest by means of DTI tractography. Conclusions: As conventional MRI is still applied in clinical practice, it should be carried out soon after the injury, at least in symptomatic patients with negative CT scan. DWI-related brain diffusivity measurements may be used to improve the documenting of TBI. DTI tractography can be used to improve radiologic diagnostics in a symptomatic TBI sub-population with no findings on conventional MRI. Reproducibility of different tools to quantify fibre tracts vary considerably, which should be taken into consideration in the clinical DTI applications.
Resumo:
Diffusion tensor imaging (DTI) is an advanced magnetic resonance imaging (MRI) technique. DTI is based on free thermal motion (diffusion) of water molecules. The properties of diffusion can be represented using parameters such as fractional anisotropy, mean diffusivity, axial diffusivity, and radial diffusivity, which are calculated from DTI data. These parameters can be used to study the microstructure in fibrous structure such as brain white matter. The aim of this study was to investigate the reproducibility of region-of-interest (ROI) analysis and determine associations between white matter integrity and antenatal and early postnatal growth at term age using DTI. Antenatal growth was studied using both the ROI and tract-based spatial statistics (TBSS) method and postnatal growth using only the TBSS method. The infants included to this study were born below 32 gestational weeks or birth weight less than 1,501 g and imaged with a 1.5 T MRI system at term age. Total number of 132 infants met the inclusion criteria between June 2004 and December 2006. Due to exclusion criteria, a total of 76 preterm infants (ROI) and 36 preterm infants (TBSS) were accepted to this study. The ROI analysis was quite reproducible at term age. Reproducibility varied between white matter structures and diffusion parameters. Normal antenatal growth was positively associated with white matter maturation at term age. The ROI analysis showed associations only in the corpus callosum. Whereas, TBSS revealed associations in several brain white matter areas. Infants with normal antenatal growth showed more mature white matter compared to small for gestational age infants. The gestational age at birth had no significant association with white matter maturation at term age. It was observed that good early postnatal growth associated negatively with white matter maturation at term age. Growth-restricted infants seemed to have delayed brain maturation that was not fully compensated at term, despite catchup growth.
Resumo:
In this doctoral thesis, a tomographic STED microscopy technique for 3D super-resolution imaging was developed and utilized to observebone remodeling processes. To improve upon existing methods, wehave used a tomographic approach using a commercially available stimulated emission depletion (STED) microscope. A certain region of interest (ROI) was observed at two oblique angles: one at a standard inverted configuration from below (bottom view) and another from the side (side view) via a micro-mirror positioned close to the ROI. The two viewing angles were reconstructed into a final tomogram. The technique, named as tomographic STED microscopy, was able to achieve an axial resolution of approximately 70 nm on microtubule structures in a fixed biological specimen. High resolution imaging of osteoclasts (OCs) that are actively resorbing bone was achieved by creating an optically transparent coating on a microscope coverglass that imitates a fractured bone surface. 2D super-resolution STED microscopy on the bone layer showed approximately 60 nm of lateral resolution on a resorption associated organelle allowing these structures to be imaged with super-resolution microscopy for the first time. The developed tomographic STED microscopy technique was further applied to study resorption mechanisms of OCs cultured on the bone coating. The technique revealed actin cytoskeleton with specific structures, comet-tails, some of which were facing upwards and some others were facing downwards. This, in our opinion, indicated that during bone resorption, an involvement of the actin cytoskeleton in vesicular exocytosis and endocytosis is present. The application of tomographic STED microscopy in bone biology demonstrated that 3D super-resolution techniques can provide new insights into biological 3D nano-structures that are beyond the diffraction-limit when the optical constraints of super-resolution imaging are carefully taken into account.
Resumo:
Currently, laser scribing is growing material processing method in the industry. Benefits of laser scribing technology are studied for example for improving an efficiency of solar cells. Due high-quality requirement of the fast scribing process, it is important to monitor the process in real time for detecting possible defects during the process. However, there is a lack of studies of laser scribing real time monitoring. Commonly used monitoring methods developed for other laser processes such a laser welding, are sufficient slow and existed applications cannot be implemented in fast laser scribing monitoring. The aim of this thesis is to find a method for laser scribing monitoring with a high-speed camera and evaluate reliability and performance of the developed monitoring system with experiments. The laser used in experiments is an IPG ytterbium pulsed fiber laser with 20 W maximum average power and Scan head optics used in the laser is Scanlab’s Hurryscan 14 II with an f100 tele-centric lens. The camera was connected to laser scanner using camera adapter to follow the laser process. A powerful fully programmable industrial computer was chosen for executing image processing and analysis. Algorithms for defect analysis, which are based on particle analysis, were developed using LabVIEW system design software. The performance of the algorithms was analyzed by analyzing a non-moving image from the scribing line with resolution 960x20 pixel. As a result, the maximum analysis speed was 560 frames per second. Reliability of the algorithm was evaluated by imaging scribing path with a variable number of defects 2000 mm/s when the laser was turned off and image analysis speed was 430 frames per second. The experiment was successful and as a result, the algorithms detected all defects from the scribing path. The final monitoring experiment was performed during a laser process. However, it was challenging to get active laser illumination work with the laser scanner due physical dimensions of the laser lens and the scanner. For reliable error detection, the illumination system is needed to be replaced.