91 resultados para Field weakening

em Doria (National Library of Finland DSpace Services) - National Library of Finland, Finland


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Direct torque control (DTC) is a new control method for rotating field electrical machines. DTC controls directly the motor stator flux linkage with the stator voltage, and no stator current controllers are used. With the DTC method very good torque dynamics can be achieved. Until now, DTC has been applied to asynchronous motor drives. The purpose of this work is to analyse the applicability of DTC to electrically excited synchronous motor drives. Compared with asynchronous motor drives, electrically excited synchronous motor drives require an additional control for the rotor field current. The field current control is called excitation control in this study. The dependence of the static and dynamic performance of DTC synchronous motor drives on the excitation control has been analysed and a straightforward excitation control method has been developed and tested. In the field weakening range the stator flux linkage modulus must be reduced in order to keep the electro motive force of the synchronous motor smaller than the stator voltage and in order to maintain a sufficient voltage reserve. The dynamic performance of the DTC synchronous motor drive depends on the stator flux linkage modulus. Another important factor for the dynamic performance in the field weakening range is the excitation control. The field weakening analysis considers both dependencies. A modified excitation control method, which maximises the dynamic performance in the field weakening range, has been developed. In synchronous motor drives the load angle must be kept in a stabile working area in order to avoid loss of synchronism. The traditional vector control methods allow to adjust the load angle of the synchronous motor directly by the stator current control. In the DTC synchronous motor drive the load angle is not a directly controllable variable, but it is formed freely according to the motor’s electromagnetic state and load. The load angle can be limited indirectly by limiting the torque reference. This method is however parameter sensitive and requires a safety margin between the theoretical torque maximum and the actual torque limit. The DTC modulation principle allows however a direct load angle adjustment without any current control. In this work a direct load angle control method has been developed. The method keeps the drive stabile and allows the maximal utilisation of the drive without a safety margin in the torque limitation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The main focus of this thesis is to define the field weakening point of permanent magnet synchronous machine with embedded magnets in traction applications. Along with the thesis a modelling program is made to help the designer to define the field weakening point in practical applications. The thesis utilizes the equations based on the current angle. These equations can be derived from the vector diagram of permanent magnet synchronous machine. The design parameters of the machine are: The maximum rotational speed, saliency ratio, maximum induced voltage and characteristic current. The main result of the thesis is finding out the rated rotational speed, from which the field weakening starts. The action of the machine is estimated at a wide speed range and the changes of machine parameters are examined.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Synchronous machines with an AC converter are used mainly in large drives, for example in ship propulsion drives as well as in rolling mill drives in steel industry. These motors are used because of their high efficiency, high overload capacity and good performance in the field weakening area. Present day drives for electrically excited synchronous motors are equipped with position sensors. Most drives for electrically excited synchronous motors will be equipped with position sensors also in future. This kind of drives with good dynamics are mainly used in metal industry. Drives without a position sensor can be used e.g. in ship propulsion and in large pump and blower drives. Nowadays, these drives are equipped with a position sensor, too. The tendency is to avoid a position sensor if possible, since a sensor reduces the reliability of the drive and increases costs (latter is not very significant for large drives). A new control technique for a synchronous motor drive is a combination of the Direct Flux Linkage Control (DFLC) based on a voltage model and a supervising method (e.g. current model). This combination is called Direct Torque Control method (DTC). In the case of the position sensorless drive, the DTC can be implemented by using other supervising methods that keep the stator flux linkage origin centered. In this thesis, a method for the observation of the drift of the real stator flux linkage in the DTC drive is introduced. It is also shown how this method can be used as a supervising method that keeps the stator flux linkage origin centered in the case of the DTC. In the position sensorless case, a synchronous motor can be started up with the DTC control, when a method for the determination of the initial rotor position presented in this thesis is used. The load characteristics of such a drive are not very good at low rotational speeds. Furthermore, continuous operation at a zero speed and at a low rotational speed is not possible, which is partly due to the problems related to the flux linkage estimate. For operation in a low speed area, a stator current control method based on the DFLC modulator (DMCQ is presented. With the DMCC, it is possible to start up and operate a synchronous motor at a zero speed and at low rotational speeds in general. The DMCC is necessary in situations where high torque (e.g. nominal torque) is required at the starting moment, or if the motor runs several seconds at a zero speed or at a low speed range (up to 2 Hz). The behaviour of the described methods is shown with test results. The test results are presented for the direct flux linkage and torque controlled test drive system with a 14.5 kVA, four pole salient pole synchronous motor with a damper winding and electric excitation. The static accuracy of the drive is verified by measuring the torque in a static load operation, and the dynamics of the drive is proven in load transient tests. The performance of the drive concept presented in this work is sufficient e.g. for ship propulsion and for large pump drives. Furthermore, the developed methods are almost independent of the machine parameters.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Synchronous motors are used mainly in large drives, for example in ship propulsion systems and in steel factories' rolling mills because of their high efficiency, high overload capacity and good performance in the field weakening range. This, however, requires an extremely good torque control system. A fast torque response and a torque accuracy are basic requirements for such a drive. For large power, high dynamic performance drives the commonly known principle of field oriented vector control has been used solely hitherto, but nowadays it is not the only way to implement such a drive. A new control method Direct Torque Control (DTC) has also emerged. The performance of such a high quality torque control as DTC in dynamically demanding industrial applications is mainly based on the accurate estimate of the various flux linkages' space vectors. Nowadays industrial motor control systems are real time applications with restricted calculation capacity. At the same time the control system requires a simple, fast calculable and reasonably accurate motor model. In this work a method to handle these problems in a Direct Torque Controlled (DTC) salient pole synchronous motor drive is proposed. A motor model which combines the induction law based "voltage model" and motor inductance parameters based "current model" is presented. The voltage model operates as a main model and is calculated at a very fast sampling rate (for example 40 kHz). The stator flux linkage calculated via integration from the stator voltages is corrected using the stator flux linkage computed from the current model. The current model acts as a supervisor that prevents only the motor stator flux linkage from drifting erroneous during longer time intervals. At very low speeds the role of the current model is emphasised but, nevertheless, the voltage model always stays the main model. At higher speeds the function of the current model correction is to act as a stabiliser of the control system. The current model contains a set of inductance parameters which must be known. The validation of the current model in steady state is not self evident. It depends on the accuracy of the saturated value of the inductances. Parameter measurement of the motor model where the supply inverter is used as a measurement signal generator is presented. This so called identification run can be performed prior to delivery or during drive commissioning. A derivation method for the inductance models used for the representation of the saturation effects is proposed. The performance of the electrically excited synchronous motor supplied with the DTC inverter is proven with experimental results. It is shown that it is possible to obtain a good static accuracy of the DTC's torque controller for an electrically excited synchronous motor. The dynamic response is fast and a new operation point is achieved without oscillation. The operation is stable throughout the speed range. The modelling of the magnetising inductance saturation is essential and cross saturation has to be considered as well. The effect of cross saturation is very significant. A DTC inverter can be used as a measuring equipment and the parameters needed for the motor model can be defined by the inverter itself. The main advantage is that the parameters defined are measured in similar magnetic operation conditions and no disagreement between the parameters will exist. The inductance models generated are adequate to meet the requirements of dynamically demanding drives.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The objective of this master thesis is to test according to hoisting requirements, a servo drive system and compare its performance with the performance of a drive equipped with a vector controlled frequency converter. Both systems utilize closed-loop vector control based on PCL program control. In order to compare the results of tests both systems were connected to the same motor driving a variable speed electrical chain hoist. Tests were based on requirements to both systems. As requirements of tests zero speed operation, operation in field weakening, positioning accuracy and smoothness of motion are taken into consideration. Both systems demonstrate quite similar performance and meet the requirements. Servo drive system demonstrates a high positioning accuracy and dynamic performance. Frequency converter is not able to provide the same positioning accuracy and dynamic performance as servo drive.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Työssä tarkastellaan hybridi- ja sähköajoneuvojen voimankäyttöjärjestelmiä ja bussin ajomoottorina toimivan kestomagneettitahtikoneen toimintaa ja sen soveltuvuutta ajoneuvokäyttöön. Esitetään analyyttinen työkalu kestomagneettitahtikoneen induktanssisuunnittelun ja koneen vääntömomentin tuottokyvyn optimoinnin tueksi. Työkalua hyödynnetään esitettävässä ajomoottorin mitoituslaskelmassa. Työssä päätellään, että kestomagneettitahtimoottori soveltuu hyvin ajoneuvokäyttöön. Maksimaalisen vääntömomentin saavuttamiseksi sen roottorin rakenne ja induktanssit on optimoitava. Analysoimalla ajoneuvokäyttöön tarkoitettua kestomagneettitahtimoottoria työkalun avulla havaitaan, että yhtä suuremmalla induktanssisuhteella vääntömomentti on pienempi kentänheikennyksessä kuin ajettaessa konetta taajuusmuuttajalla vakioteholla nimelliskuormalla. Vastaavasti yhtä pienemmillä induktanssisuhteilla vääntömomentti on pienempi kentänheikennyksessä. Todetaan, että vääntömomentti kasvaa induktanssisuhteen poiketessa yhdestä. Suuri vääntömomentti saadaan pienillä induktanssisuhteilla. Induktanssisuhteen kasvattaminen yhdestä ei lisää moottorin tuottamaa vääntömomenttia yhtä paljon kuin induktanssisuhteen pienentäminen. Työn lopuksi verrataan työkalun laskemia tuloksia kirjallisuudesta löytyvillä yhtälöillä laskettuihin tuloksiin. Työkalun laskemat tulokset vaikuttavat ristiriidattomilta ja yhteneväisiltä teorian kanssa. Työkalun toteutuksessa tehdyt teoreettiset yksinkertaistukset aiheuttavat todennäköisesti epätarkkuutta tuloksissa erityisesti suurella kuormituksella.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Traction motor design significantly differs from industrial machine design. The starting point is the load cycle instead of the steady-state rated operation point. The speed of the motor varies from zero to very high speeds. At low speeds, heavy overloading is used for starting, and the field-weakening region also plays an important role. Finding a suitable fieldweakening point is one of the important design targets. At the lowest speeds, a high torque output is desired, and all current reserves of the supplying converter unit are used to achieve the torque. In this paper, a 110-kW 2.5-p.u. starting torque and a maximum 2.5-p.u. speed permanent-magnet traction motor will be studied. The field-weakening point is altered by varying the number of winding turns of machine. One design is selected for prototyping. Theoretical results are verified by measurements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Selostus: Niittyluteiden esiintyminen viljelykasveissa kasvukauden eri aikoina

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Selostus: Lannoituksen pitkäaikaiset kenttäkokeet: kolmen matemaattisen mallin vertailu

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Selostus: Vanhojen ja uusien kauralajikkeiden reagointi kuivuuteen kasvihuone- ja peltokokeissa

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Selostus: Maan fosforitilan muutos pitkäaikaisessa kenttäkokeessa hietamaalla