38 resultados para Energy Storage
em Doria (National Library of Finland DSpace Services) - National Library of Finland, Finland
Resumo:
In recent years the environmental issues and the energy saving have become increasingly import in modern society where industry is the major emission factor and energy consumer. Generally, most of the total energy consumption is caused by electrical drives used in industrial applications and thus improving the performance of electrical drives give an opportunity to improve the energy efficiency. In this Master Thesis improving the energy efficiency in different electrical drives is clarified with different cases: regenerative braking in the electric grid or recovery of the braking energy into an energy storage. In addition, as an example, the energy consumption of an elevator is analyzed by measurements. From these measurement results it can be estimated how much the share of the standby energy consumption is from the total energy consumption and how much regenerative energy is available. The latter part of the thesis concentrates on determination of the properties of lithium iron phosphate battery with measurements.
Resumo:
The global interest towards renewable energy production such as wind and solar energy is increasing, which in turn calls for new energy storage concepts due to the larger share of intermittent energy production. Power-to-gas solutions can be utilized to convert surplus electricity to chemical energy which can be stored for extended periods of time. The energy storage concept explored in this thesis is an integrated energy storage tank connected to an oxy-fuel combustion plant. Using this approach, flue gases from the plant could be fed directly into the storage tank and later converted into synthetic natural gas by utilizing electrolysis-methanation route. This work utilizes computational fluid dynamics to model the desublimation of carbon dioxide inside a storage tank containing cryogenic liquid, such as liquefied natural gas. Numerical modelling enables the evaluation of the transient flow patterns caused by the desublimation, as well as general fluid behaviour inside the tank. Based on simulations the stability of the cryogenic storage and the magnitude of the key parameters can be evaluated.
Resumo:
Transmission system operators and distribution system operators are experiencing new challenges in terms of reliability, power quality, and cost efficiency. Although the potential of energy storages to face those challenges is recognized, the economic implications are still obscure, which introduce the risk into the business models. This thesis aims to investigate the technical and economic value indicators of lithium-ion battery energy storage systems (BESS) in grid-scale applications. In order to do that, a comprehensive performance lithium-ion BESS model with degradation effects estimation is developed. The model development process implies literature review on lifetime modelling, use, and modification of previous study progress, building the additional system parts and integrating it into a complete tool. The constructed model is capable of describing the dynamic behavior of the BESS voltage, state of charge, temperature and capacity loss. Five control strategies for BESS unit providing primary frequency regulation are implemented, in addition to the model. The questions related to BESS dimensioning and the end of life (EoL) criterion are addressed. Simulations are performed with one-month real frequency data acquired from Fingrid. The lifetime and cost-benefit analysis of the simulation results allow to compare and determine the preferable control strategy. Finally, the study performs the sensitivity analysis of economic profitability with variable size, EoL and system price. The research reports that BESS can be profitable in certain cases and presents the recommendations.
Resumo:
The share of variable renewable energy in electricity generation has seen exponential growth during the recent decades, and due to the heightened pursuit of environmental targets, the trend is to continue with increased pace. The two most important resources, wind and insolation both bear the burden of intermittency, creating a need for regulation and posing a threat to grid stability. One possibility to deal with the imbalance between demand and generation is to store electricity temporarily, which was addressed in this thesis by implementing a dynamic model of adiabatic compressed air energy storage (CAES) with Apros dynamic simulation software. Based on literature review, the existing models due to their simplifications were found insufficient for studying transient situations, and despite of its importance, the investigation of part load operation has not yet been possible with satisfactory precision. As a key result of the thesis, the cycle efficiency at design point was simulated to be 58.7%, which correlated well with literature information, and was validated through analytical calculations. The performance at part load was validated against models shown in literature, showing good correlation. By introducing wind resource and electricity demand data to the model, grid operation of CAES was studied. In order to enable the dynamic operation, start-up and shutdown sequences were approximated in dynamic environment, as far as is known, the first time, and a user component for compressor variable guide vanes (VGV) was implemented. Even in the current state, the modularly designed model offers a framework for numerous studies. The validity of the model is limited by the accuracy of VGV correlations at part load, and in addition the implementation of heat losses to the thermal energy storage is necessary to enable longer simulations. More extended use of forecasts is one of the important targets of development, if the system operation is to be optimised in future.
Resumo:
This Master's thesis deals with a Micro Scale Wind Wind Turbine application. The thesis consists of nine chapters. The first chapter is an introduction to the philosophy of a small scale wind turbine application. The second defines concepts, and lists the requirements. The third presents the whole application for an On-Grid , and for an Off-Grid arrangement, with main concentration on lighting, heating, and energy storage. The fourth deals with the Inverter's technology, which are used for the conversion of the produced power. The fifth chapter presents the available storage technology and it's possibilities. The sixth deals with the system, and the technological means used for the implementation. The seventh presents the PLC device, which was used as the controller for the management of the whole application. The eighth deals with the concept and the control application philosophy that the PLC involves. And the final chapter presents conclusions and ideas for further considerations.
Resumo:
The number of autonomous wireless sensor and control nodes has been increasing rapidly during the last decade. Until recently, these wireless nodes have been powered with batteries, which have lead to a short life cycle and high maintenance need. Due to these battery-related problems, new energy sources have been studied to power wireless nodes. One solution is energy harvesting, i.e. extracting energy from the ambient environment. Energy harvesting can provide a long-lasting power source for sensor nodes, with no need for maintenance. In this thesis, various energy harvesting technologies are studied whilst focusing on the theory of each technology and the state-of-the-art solutions of published studies and commercial solutions. In addition to energy harvesting, energy storage and energy management solutions are also studied as a subsystem of a whole energy source solution. Wireless nodes are also used in heavy-duty vehicles. Therefore a reliable, long-lasting and maintenance-free power source is also needed in this kind of environment. A forestry harvester has been used as a case study to study the feasibility of energy harvesting in a forestry harvester’s sliding boom. The energy harvester should be able to produce few milliwatts to power the target system, an independent limit switch.
Resumo:
The power demand of many mobile working machines such as mine loaders, straddle carriers and harvesters varies significantly during operation, and typically, the average power demand of a working machine is considerably lower than the demand for maximum power. Consequently, for most of the time, the diesel engine of a working machine operates at a poor efficiency far from its optimum efficiency range. However, the energy efficiency of dieseldriven working machines can be improved by electric hybridization. This way, the diesel engine can be dimensioned to operate within its optimum efficiency range, and the electric drive with its energy storages responds to changes in machine loading. A hybrid working machine can be implemented in many ways either as a parallel hybrid, a series hybrid or a combination of these two. The energy efficiency of hybrid working machines can be further enhanced by energy recovery and reuse. This doctoral thesis introduces the component models required in the simulation model of a working machine. Component efficiency maps are applied to the modelling; the efficiency maps for electrical machines are determined analytically in the whole torque–rotational speed plane based on the electricalmachine parameters. Furthermore, the thesis provides simulation models for parallel, series and parallel-series hybrid working machines. With these simulation models, the energy consumption of the working machine can be analysed. In addition, the hybridization process is introduced and described. The thesis provides a case example of the hybridization and dimensioning process of a working machine, starting from the work cycle of the machine. The selection and dimensioning of the hybrid system have a significant impact on the energy consumption of a hybrid working machine. The thesis compares the energy consumption of a working machine implemented by three different hybrid systems (parallel, series and parallel-series) and with different component dimensions. The payback time of a hybrid working machine and the energy storage lifetime are also estimated in the study.
Resumo:
The Thesis is dedicated to development of an operative tool to support decision making of battery energy storages implementation in distribution networks. The basics of various battery technologies, their perspectives and challenges are represented in the Thesis. Mathematical equations that describe economic effect from battery energy storage installation are offered. The main factors that influence profitability of battery settings have been explored and mathematically defined. Mathematical model and principal trends of battery storage profitability under an impact of the major factors are determined. The meaning of annual net value was introduced to show the difference between savings and required costs. The model gives a clear vision for dependencies between annual net value and main factors. Proposals for optimal network and battery characteristics are suggested.
Resumo:
This thesis is done as a part of the NEOCARBON project. The aim of NEOCARBON project is to study a fully renewable energy system utilizing Power-to-Gas or Power-to-Liquid technology for energy storage. Power-to-Gas consists of two main operations: Hydrogen production via electrolysis and methane production via methanation. Methanation requires carbon dioxide and hydrogen as a raw material. This thesis studies the potential carbon dioxide sources within Finland. The different sources are ranked using the cost and energy penalty of the carbon capture, carbon biogenity and compatibility with Power-to-Gas. It can be concluded that in Finland there exists enough CO2 point sources to provide national PtG system with sufficient amounts of carbon. Pulp and paper industry is single largest producer of biogenic CO2 in Finland. It is possible to obtain single unit capable of grid balancing operations and energy transformations via Power-to-Gas and Gas-to-Power by coupling biogas plants with biomethanation and CHP units.
Resumo:
Recent developments in power electronics technology have made it possible to develop competitive and reliable low-voltage DC (LVDC) distribution networks. Further, islanded microgrids—isolated small-scale localized distribution networks— have been proposed to reliably supply power using distributed generations. However, islanded operations face many issues such as power quality, voltage regulation, network stability, and protection. In this thesis, an energy management system (EMS) that ensures efficient energy and power balancing and voltage regulation has been proposed for an LVDC island network utilizing solar panels for electricity production and lead-acid batteries for energy storage. The EMS uses the master/slave method with robust communication infrastructure to control the production, storage, and loads. The logical basis for the EMS operations has been established by proposing functionalities of the network components as well as by defining appropriate operation modes that encompass all situations. During loss-of-powersupply periods, load prioritizations and disconnections are employed to maintain the power supply to at least some loads. The proposed EMS ensures optimal energy balance in the network. A sizing method based on discrete-event simulations has also been proposed to obtain reliable capacities of the photovoltaic array and battery. In addition, an algorithm to determine the number of hours of electric power supply that can be guaranteed to the customers at any given location has been developed. The successful performances of all the proposed algorithms have been demonstrated by simulations.
Resumo:
IIn electric drives, frequency converters are used to generatefor the electric motor the AC voltage with variable frequency and amplitude. When considering the annual sale of drives in values of money and units sold, the use of low-performance drives appears to be in predominant. These drives have tobe very cost effective to manufacture and use, while they are also expected to fulfill the harmonic distortion standards. One of the objectives has also been to extend the lifetime of the frequency converter. In a traditional frequency converter, a relatively large electrolytic DC-link capacitor is used. Electrolytic capacitors are large, heavy and rather expensive components. In many cases, the lifetime of the electrolytic capacitor is the main factor limiting the lifetime of the frequency converter. To overcome the problem, the electrolytic capacitor is replaced with a metallized polypropylene film capacitor (MPPF). The MPPF has improved properties when compared to the electrolytic capacitor. By replacing the electrolytic capacitor with a film capacitor the energy storage of the DC-linkwill be decreased. Thus, the instantaneous power supplied to the motor correlates with the instantaneous power taken from the network. This yields a continuousDC-link current fed by the diode rectifier bridge. As a consequence, the line current harmonics clearly decrease. Because of the decreased energy storage, the DC-link voltage fluctuates. This sets additional conditions to the controllers of the frequency converter to compensate the fluctuation from the supplied motor phase voltages. In this work three-phase and single-phase frequency converters with small DC-link capacitor are analyzed. The evaluation is obtained with simulations and laboratory measurements.
Resumo:
Hybrid electric vehicles (HEV) have attracted very much attention during the latest years. Increasing environmental concern and an increase in fuel prices are key factors for the growing interest towards the HEV. In a hybrid electric vehicle the power train consists of both a mechanical power system and an electric power transmission system. The major subsystems in the mechanical power system are the internal combustion engine which powers the vehicle; electric power transmission including an energy storage, power electronic inverter, hybrid control system; the electric motor drive that runs either in the generating mode or in the motoring mode to process the power flow between the energy storage and the electrical machine. This research includes two advanced electric motors for a parallel hybrid: induction machine and permanent magnets synchronous machine. In the thesis an induction motor and a permanent magnet motor are compared as propulsion motors. Electric energy storages are also studied.
Resumo:
Ajoneuvojen tiukentuneet päästörajoitukset, sekä ajoneuvojen kokonaishyötysuhteen parantamisen tarve ohjaavat ajoneuvovalmistajia kehittämään uusia ratkaisuja. Energiavarastojen käyttö ajoneuvoissa on yleistynyt ja niiden käytöllä voidaan saada huomattava energiasäästö. Tässä kandidaatintyössä on esitelty erilaisia energiavarastoja ja niiden verkkoon liittämistä. Pääpaino työssä on akkujen ja superkondensaattorien rinnankytkennässä. Energiavarastot pyritään kytkemään mahdollisimman vähällä tehoelektroniikalla verkkoon. Esimerkkitapaukseksi on otettu litium-ioni akkujen ja superkondensaattorien rinnankytkentä vaihtojännitteeseen pelkällä invertterillä.
Resumo:
Jatkuvasti kiristyvät päästörajoitukset ajavat eri alojen energiatuottajia kehittämään uusia ratkaisuja päästöjen pienentämiseksi. Viime aikoina myös laivojen päästörajoituksia on tiukennettu ja tulevaisuudessa niitä tullaan tiukentamaan lisää. Nämä tiukentuvat päästörajoitukset asettavat myös laivan dieselmoottoreiden valmistajat uusien haasteiden eteen. Yhtenä vaihtoehtona on lisätä dieselmoottorin rinnalle energiavarasto, joka vähentää dieselmoottorin päästöjä varsinkin nopeissa kuormituksen muutoksissa. Tässä diplomityössä tarkastellaan sähköisten energiavarastojen mitoitusta laivan sähköjärjestelmään. Energiavarastot mitoitetaan useaan eri toimintatilanteeseen. Mitoituksen lisäksi pohditaan energiavarastoilla saatavaa mahdollista rahallista hyötyä sekä päästöjen vähenemistä.
Resumo:
Persistent luminescence materials can store energy from solar radiation or artificial lighting and release it over a period of several hours without a continuous excitation source. These materials are widely used to improve human safety in emergency and traffic signalization. They can also be utilized in novel applications including solar cells, medical diagnostics, radiation detectors and structural damage sensors. The development of these materials is currently based on methods based on trial and error. The tailoring of new materials is also hindered by the lack of knowledge on the role of their intrinsic and extrinsic lattice defects in the appropriate mechanisms. The goal of this work was to clarify the persistent luminescence mechanisms by combining ab initio density functional theory (DFT) calculations with selected experimental methods. The DFT approach enables a full control of both the nature of the defects and their locations in the host lattice. The materials studied in the present work, the distrontium magnesium disilicate (Sr2MgSi2O7) and strontium aluminate (SrAl2O4) are among the most efficient persistent luminescence hosts when doped with divalent europium Eu2+ and co-doped with trivalent rare earth ions R3+ (R: Y, La-Nd, Sm, Gd-Lu). The polycrystalline materials were prepared with the solid state method and their structural and phase purity was confirmed by X-ray powder diffraction. Their local crystal structure was studied by high-resolution transmission electron microscopy. The crystal and electronic structure of the nondoped as well as Eu2+, R2+/3+ and other defect containing materials were studied using DFT calculations. The experimental trap depths were obtained using thermoluminescence (TL) spectroscopy. The emission and excitation of Sr2MgSi2O7:Eu2+,Dy3+ were also studied. Significant modifications in the local crystal structure due to the Eu2+ ion and lattice defects were found by the experimental and DFT methods. The charge compensation effects induced by the R3+ co-doping further increased the number of defects and distortions in the host lattice. As for the electronic structure of Sr2MgSi2O7 and SrAl2O4, the experimental band gap energy of the host materials was well reproduced by the calculations. The DFT calculated Eu2+ and R2+/3+ 4fn as well as 4fn-15d1 ground states in the Sr2MgSi2O7 band structure provide an independent verification for an empirical model which is constructed using rather sparse experimental data for the R3+ and especially the R2+ ions. The intrinsic and defect induced electron traps were found to act together as energy storage sites contributing to the materials’ efficient persistent luminescence. The calculated trap energy range agreed with the trap structure of Sr2MgSi2O7 obtained using TL measurements. More experimental studies should be carried out for SrAl2O4 to compare with the DFT calculations. The calculated and experimental results show that the electron traps created by both the rare earth ions and vacancies are modified due to the defect aggregation and charge compensation effects. The relationships between this modification and the energy storage properties of the solid state materials are discussed.