13 resultados para Dual-head
em Doria (National Library of Finland DSpace Services) - National Library of Finland, Finland
Resumo:
In this thesis I argue that the psychological study of concepts and categorisation, and the philosophical study of reference are deeply intertwined. I propose that semantic intuitions are a variety of categorisation judgements, determined by concepts, and that because of this, concepts determine reference. I defend a dual theory of natural kind concepts, according to which natural kind concepts have distinct semantic cores and non-semantic identification procedures. Drawing on psychological essentialism, I suggest that the cores consist of externalistic placeholder essence beliefs. The identification procedures, in turn, consist of prototypes, sets of exemplars, or possibly also theory-structured beliefs. I argue that the dual theory is motivated both by experimental data and theoretical considerations. The thesis consists of three interrelated articles. Article I examines philosophical causal and description theories of natural kind term reference, and argues that they involve, or need to involve, certain psychological elements. I propose a unified theory of natural kind term reference, built on the psychology of concepts. Article II presents two semantic adaptations of psychological essentialism, one of which is a strict externalistic Kripkean-Putnamian theory, while the other is a hybrid account, according to which natural kind terms are ambiguous between internalistic and externalistic senses. We present two experiments, the results of which support the strict externalistic theory. Article III examines Fodor’s influential atomistic theory of concepts, according to which no psychological capacities associated with concepts constitute them, or are necessary for reference. I argue, contra Fodor, that the psychological mechanisms are necessary for reference.
Resumo:
The main goal of the thesis was to further develop harvester head saw device to the Finnish forest machine manufacturer. The work was done from the basis of the manufacturer´s current production model and the earlier study from this same subject called: “Development of chain saw for harvester” Tero Kaatrasalo, 2004. The work was focused to improving the serviceability and reliability of the saw device, but design also included adding few beforehand determined new features into the saw unit. This was done to give some added value for the end customer. The work includes analysis of the earlier saw devices and ideations of the improvements for the structure.
Resumo:
Gene therapy aims to treat diseases by introducing genetic material to the diseased tissue. For cancer treatment it is important to destroy cancerous cells; this can be achieved by introducing a gene, which induces cell death or by allowing viral vectors to replicate, which also results in destruction of cancerous cells. For cardiac diseases the approach is more like the former, except the gene produces beneficial effects, like angiogenesis. Adenoviruses have many beneficial qualities, which make the virus an interesting gene therapy vector; it can be produced relatively easily, its manipulation is quite easy and it has naturally broad tropism. By removing or replacing certain genes in the adenoviral genome, it can be made non-replicative. In this study, adenoviral receptor expression patterns were characterized in both head and neck squamous cell carcinoma and the human heart. Adenovirus serotype 5 receptor expression in head and neck cancer cell lines was found to be highly variable between cell lines and overall at lower levels, while Ad35 receptor expression was more uniform and at higher levels in all analyzed cell lines. It was also shown that a hybrid virus Ad5/35 is able to infect cells refractory to Ad5, which correlates with receptor expression in these cells. Furthermore, this difference in infection properties extends to cell killing efficiency in case of conditionally replicative viruses. Expression levels of adenoviral receptors CAR, CD46, CD86 and αv-integrins were found to be high both in normal and dilated cardiomyopathy heart tissue. The receptor levels also correlate with transduction efficiency after intracardiac injection. Ad5 showed superior transduction ability compared with Ad5/35, but evoked also a more profound immune reaction when administered this way. Adenoviral gene therapy vectors are the most used delivery vehicles in clinical trials to date. These vectors have proven to be well tolerated and positive results have been obtained when combined with traditional treatments, although poor transduction efficiency has often been reported due to low-level expression of viral receptors on target cells. In spite of this, the results are encouraging and merit for further research.
Resumo:
The goal of this study was to find a new approach to modify chemically the properties of paper by improving fiber quality. This Master’s thesis includes the multiple polymer treatment in general and themeasurement methods with which the formation of multilayers and complexes can be noticed. The treatment by an oppositely charged dual polymer system is a good approach to increase paper strength. In this work, starch, a cationic polymer, and carboxymethyl cellulose (CMC), an anionic polymer, were used step-by-step to improve paper strength. The adsorption of cationic starch and CMC on cellulose fibers were analyzed via polyelectrolyte titration. The results showed that paper strength was enhanced slightly with a layer-by-layer assembly of the polymers. However, if the washing stage, which was required for layer-by-layer assembly, was eliminated, the starch/CMC complex was deposited on fibers more efficiently, and the paper strength was improved more significantly.
Resumo:
Most advanced tumours face periods of reduced oxygen availability i.e. hypoxia. During these periods tumour cells undergo adaptive changes enabling their survival under adverse conditions. In cancer hypoxia-induced cellular changes cause tumour progression, hinder cancer treatment and are indicative of poor prognosis. Within cells the main regulator of hypoxic responses is the hypoxia-inducible factor (HIF). HIF governs the expression of over a hundred hypoxia-inducible genes that regulate a number of cellular functions such as angiogenesis, glucose metabolism and cell migration. Therefore the activity of HIF must be tightly governed. HIF is regulated by a family of prolyl hydroxylase enzymes, PHDs, which mark HIF for destruction in normoxia. Under hypoxic conditions PHDs lose much of their enzymatic activity as they need molecular oxygen as a cofactor. Out of the three PHDs (PHD1, 2 and 3) PHD2 has been considered to be the main HIF-1 regulator in normoxic conditions. PHD3 on the other hand shows the most robust induction in response to oxygen deprivation and it has been implied as the main HIF-1 regulator under prolonged hypoxia. SQSTM1/p62 (p62) is an adaptor protein that functions through its binding motifs to bring together proteins in order to regulate signal transduction. In non-stressed situations p62 levels are kept low but its expression has been reported to be upregulated in many cancers. It has a definitive role as an autophagy receptor and as such it serves a key function in cancer cell survival decisions. In my thesis work I evaluated the significance of PHD3 in cancer cell and tumour biology. My results revealed that PHD3 has a dual role in cancer cell fate. First, I demonstrated that PHD3 forms subcellular protein aggregates in oxygenated carcinoma cells and that this aggregation promotes apoptosis induction in a subset of cancer cells. In these aggregates an adaptor protein SQSTM1/p62 interacts with PHD3 and in so doing regulates PHD3 expression. SQSTM1/p62 expression is needed to keep PHD3 levels low in normoxic conditions. Its levels rapidly decrease in response to hypoxia allowing PHD3 protein levels to be upregulated and the protein to be diffusely expressed throughout the cell. The interaction between PHD3 and SQSTM1/p62 limits the ability of PHD3 to function on its hydroxylation target protein HIF-1alpha. Second, the results indicate that when PHD3 is upregulated under hypoxia it protects cancer cells by allowing cell cycle to proceed from G1 to S-phase. My data demonstrates that PHD3 may either cause cell death or protect the cells depending on its expression pattern and the oxygen availability of tumours.
Resumo:
Hydraulic head is distributed through a medium with porous aspect. The analysis of hydraulic head from one point to another is used by the Richard's equation. This equation is equivalent to the groundwater ow equation that predicts the volumetric water contents. COMSOL 3.5 is used for computation applying Richard's equation. A rectangle of 100 meters of length and 10 meters of large (depth) with 0,1 m/s fl ux of inlet as source of our fl uid is simulated. The domain have Richards' equation model in two dimension (2D). Hydraulic head increases proportional with moisture content.
Resumo:
Positron Emission Tomography (PET) using 18F-FDG is playing a vital role in the diagnosis and treatment planning of cancer. However, the most widely used radiotracer, 18F-FDG, is not specific for tumours and can also accumulate in inflammatory lesions as well as normal physiologically active tissues making diagnosis and treatment planning complicated for the physicians. Malignant, inflammatory and normal tissues are known to have different pathways for glucose metabolism which could possibly be evident from different characteristics of the time activity curves from a dynamic PET acquisition protocol. Therefore, we aimed to develop new image analysis methods, for PET scans of the head and neck region, which could differentiate between inflammation, tumour and normal tissues using this functional information within these radiotracer uptake areas. We developed different dynamic features from the time activity curves of voxels in these areas and compared them with the widely used static parameter, SUV, using Gaussian Mixture Model algorithm as well as K-means algorithm in order to assess their effectiveness in discriminating metabolically different areas. Moreover, we also correlated dynamic features with other clinical metrics obtained independently of PET imaging. The results show that some of the developed features can prove to be useful in differentiating tumour tissues from inflammatory regions and some dynamic features also provide positive correlations with clinical metrics. If these proposed methods are further explored then they can prove to be useful in reducing false positive tumour detections and developing real world applications for tumour diagnosis and contouring.
Resumo:
Presentation at Open Repositories 2014, Helsinki, Finland, June 9-13, 2014
Resumo:
UG2-päivitys korvasi vanhan Hawkin mittareita nykyaikaisella Head-Up Displaylla. Tutkielmassa selvitetään kuinka UG2-päivitetyn Hawkin Head-Up Display toimii. Tämä selvitetään tutustumalla laitteen tekniseen toimintaan sekä selvittämällä mitä merkkejä ja arvoja HUD:illa esitetään eri tilanteissa. UG2-päivitys mahdollistaa jatkossa HUD:in merkkien päivittämisen helposti tietokoneen avulla, eikä laitteita tarvitse vaihtaa. Tutkimus on kvalitatiivinen, ja siinä tehdään deskriptiivinen tutkimus yhden laitteen toiminnasta. Tärkeimpinä lähteinä käytetään ilmavoimien omaa materiaalia koskien kyseistä päivitystä ja ohjaajan koulutukseen käytettävää Air Crew Manual (ACM) -ohjekirjaa. Ulkopuolisista lähteistä on selvitetty laitteen teknistä toimintaa ja arvojen sijoitteluun sovittuja sääntöjä ja normeja. Tutkielmassa selviää, että HUD on ensisijaisesti käytettävä näyttö, joka siirtää ohjaajan katseen ulos ohjaamosta. Tekniikka luo haasteita näyttölaitteen koolle, koska arvot heijastetaan ja tarkennetaan äärettömään, luoden ohjaajalle vain pienen kohdan, jossa arvot näkyvät. Merkkien sijainti noudattaa Basic-T -mallia, jolla analogisten mittareiden helppolukuisuus on siirretty HUD:ille. Tutkimuksen mukaan merkkien tulee myös sijaita lähellä toisiaan. Tutkielman johtopäätökset rakentuvat koneiden ja laitteiden yhteensopivuuden ympärille. HUD siirtää ohjaajan katseen ulos koneesta, joten se tuo lisää koulutusmahdollisuuksia. Poistamalla tietoja HUD:ilta lennon aikana, joutuisi ohjaaja tukeutumaan muihin arvoihin ja näköönsä, näin parantaen tilannetietoisuutta. Tämä parantaisi ohjaajan toimintaa kaikissa koneissa, varsinkin laitteiden vikatilanteissa. Lisäksi HUD:in merkit olisi sovitettava yhteen sähköisten varamittareiden, Hawkissa BFI:n kanssa, jotta siitä saataisiin ”mini-HUD”.
Resumo:
Tool center point calibration is a known problem in industrial robotics. The major focus of academic research is to enhance the accuracy and repeatability of next generation robots. However, operators of currently available robots are working within the limits of the robot´s repeatability and require calibration methods suitable for these basic applications. This study was conducted in association with Stresstech Oy, which provides solutions for manufacturing quality control. Their sensor, based on the Barkhausen noise effect, requires accurate positioning. The accuracy requirement admits a tool center point calibration problem if measurements are executed with an industrial robot. Multiple possibilities are available in the market for automatic tool center point calibration. Manufacturers provide customized calibrators to most robot types and tools. With the handmade sensors and multiple robot types that Stresstech uses, this would require great deal of labor. This thesis introduces a calibration method that is suitable for all robots which have two digital input ports free. It functions with the traditional method of using a light barrier to detect the tool in the robot coordinate system. However, this method utilizes two parallel light barriers to simultaneously measure and detect the center axis of the tool. Rotations about two axes are defined with the center axis. The last rotation about the Z-axis is calculated for tools that have different width of X- and Y-axes. The results indicate that this method is suitable for calibrating the geometric tool center point of a Barkhausen noise sensor. In the repeatability tests, a standard deviation inside robot repeatability was acquired. The Barkhausen noise signal was also evaluated after recalibration and the results indicate correct calibration. However, future studies should be conducted using a more accurate manipulator, since the method employs the robot itself as a measuring device.
Resumo:
Tutkielma käyttää automaattista kuviontunnistusalgoritmia ja yleisiä kahden liukuvan keskiarvon leikkauspiste –sääntöjä selittääkseen Stuttgartin pörssissä toimivien yksityissijoittajien myynti-osto –epätasapainoa ja siten vastatakseen kysymykseen ”käyttävätkö yksityissijoittajat teknisen analyysin menetelmiä kaupankäyntipäätöstensä perustana?” Perusolettama sijoittajien käyttäytymisestä ja teknisen analyysin tuottavuudesta tehtyjen tutkimusten perusteella oli, että yksityissijoittajat käyttäisivät teknisen analyysin metodeja. Empiirinen tutkimus, jonka aineistona on DAX30 yhtiöiden data vuosilta 2009 – 2013, ei tuottanut riittävän selkeää vastausta tutkimuskysymykseen. Heikko todistusaineisto näyttää kuitenkin osoittavan, että yksityissijoittajat muuttavat kaupankäyntikäyttäytymistänsä eräiden kuvioiden ja leikkauspistesääntöjen ohjastamaan suuntaan.
Resumo:
The removal of organics from copper electrolyte solutions after solvent extraction by dual media filtration is one of the most efficient ways to ensure the clean electrolyte flow into the electrowinning. The clean electrolyte will ensure the good quality cathode plate production. Dual media filtration uses two layers of filter media for filtration as anthracite and garnet respectively. The anthracite layer will help the coalescing of the entrained organic droplets which will then float to the top of the filter, and back to the solvent extraction process. The garnet layer will catch any solids left in the electrolyte traveling through the filter media. This thesis will concentrate on characterization of five different anthracites in order to find some differences using specific surface area analysis, particle size analysis, and morphology analysis. These results are compared to the pressure loss values obtained from lab column tests and bed expansion behavior. The goal of the thesis was to find out if there were any differences in the anthracite which would make the one perform better than the other. There were no big differences found on any aspect of the particle characterization, but some found differences should be further studied in order to confirm the meaning of the porosity, surface area, intensity mean and intensity SD (Standard Deviation) on anthracites and their use in dual media filtration. The thesis work analyzed anthracite samples the way that is not found on any public literature sources, and further studies on the issue would bring more knowledge to the electrolyte process.