25 resultados para Current-source inverter (CSI)

em Doria (National Library of Finland DSpace Services) - National Library of Finland, Finland


Relevância:

100.00% 100.00%

Publicador:

Resumo:

IIn electric drives, frequency converters are used to generatefor the electric motor the AC voltage with variable frequency and amplitude. When considering the annual sale of drives in values of money and units sold, the use of low-performance drives appears to be in predominant. These drives have tobe very cost effective to manufacture and use, while they are also expected to fulfill the harmonic distortion standards. One of the objectives has also been to extend the lifetime of the frequency converter. In a traditional frequency converter, a relatively large electrolytic DC-link capacitor is used. Electrolytic capacitors are large, heavy and rather expensive components. In many cases, the lifetime of the electrolytic capacitor is the main factor limiting the lifetime of the frequency converter. To overcome the problem, the electrolytic capacitor is replaced with a metallized polypropylene film capacitor (MPPF). The MPPF has improved properties when compared to the electrolytic capacitor. By replacing the electrolytic capacitor with a film capacitor the energy storage of the DC-linkwill be decreased. Thus, the instantaneous power supplied to the motor correlates with the instantaneous power taken from the network. This yields a continuousDC-link current fed by the diode rectifier bridge. As a consequence, the line current harmonics clearly decrease. Because of the decreased energy storage, the DC-link voltage fluctuates. This sets additional conditions to the controllers of the frequency converter to compensate the fluctuation from the supplied motor phase voltages. In this work three-phase and single-phase frequency converters with small DC-link capacitor are analyzed. The evaluation is obtained with simulations and laboratory measurements.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The maximum realizable power throughput of power electronic converters may be limited or constrained by technical or economical considerations. One solution to this problemis to connect several power converter units in parallel. The parallel connection can be used to increase the current carrying capacity of the overall system beyond the ratings of individual power converter units. Thus, it is possible to use several lower-power converter units, produced in large quantities, as building blocks to construct high-power converters in a modular manner. High-power converters realized by using parallel connection are needed for example in multimegawatt wind power generation systems. Parallel connection of power converter units is also required in emerging applications such as photovoltaic and fuel cell power conversion. The parallel operation of power converter units is not, however, problem free. This is because parallel-operating units are subject to overcurrent stresses, which are caused by unequal load current sharing or currents that flow between the units. Commonly, the term ’circulatingcurrent’ is used to describe both the unequal load current sharing and the currents flowing between the units. Circulating currents, again, are caused by component tolerances and asynchronous operation of the parallel units. Parallel-operating units are also subject to stresses caused by unequal thermal stress distribution. Both of these problemscan, nevertheless, be handled with a proper circulating current control. To design an effective circulating current control system, we need information about circulating current dynamics. The dynamics of the circulating currents can be investigated by developing appropriate mathematical models. In this dissertation, circulating current models aredeveloped for two different types of parallel two-level three-phase inverter configurations. Themodels, which are developed for an arbitrary number of parallel units, provide a framework for analyzing circulating current generation mechanisms and developing circulating current control systems. In addition to developing circulating current models, modulation of parallel inverters is considered. It is illustrated that depending on the parallel inverter configuration and the modulation method applied, common-mode circulating currents may be excited as a consequence of the differential-mode circulating current control. To prevent the common-mode circulating currents that are caused by the modulation, a dual modulator method is introduced. The dual modulator basically consists of two independently operating modulators, the outputs of which eventually constitute the switching commands of the inverter. The two independently operating modulators are referred to as primary and secondary modulators. In its intended usage, the same voltage vector is fed to the primary modulators of each parallel unit, and the inputs of the secondary modulators are obtained from the circulating current controllers. To ensure that voltage commands obtained from the circulating current controllers are realizable, it must be guaranteed that the inverter is not driven into saturation by the primary modulator. The inverter saturation can be prevented by limiting the inputs of the primary and secondary modulators. Because of this, also a limitation algorithm is proposed. The operation of both the proposed dual modulator and the limitation algorithm is verified experimentally.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this doctoral thesis, a power conversion unit for a 10 kWsolid oxide fuel cell is modeled, and a suitable control system is designed. The need for research was identified based on an observation that there was no information available about the characteristics of the solid oxide fuel cell from the perspective of power electronics and the control system, and suitable control methods had not previously been studied in the literature. In addition, because of the digital implementation of the control system, the inherent characteristics of the digital system had to be taken into account in the characteristics of the solid oxide fuel cell (SOFC). The characteristics of the solid oxide fuel cell as well the methods for the modeling and control of the DC/DC converter and the grid converter are studied by a literature survey. Based on the survey, the characteristics of the SOFC as an electrical power source are identified, and a solution to the interfacing of the SOFC in distributed generation is proposed. A mathematical model of the power conversion unit is provided, and the control design for the DC/DC converter and the grid converter is made based on the proposed interfacing solution. The limit cycling phenomenon is identified as a source of low-frequency current ripple, which is found to be insignificant when connected to a grid-tied converter. A method to mitigate a second harmonic originating from the grid interface is proposed, and practical considerations of the operation with the solid oxide fuel cell plant are presented. At the theoretical level, the thesis discusses and summarizes the methods to successfully derive a model for a DC/DC converter, a grid converter, and a power conversion unit. The results of this doctoral thesis can also be used in other applications, and the models and methods can be adopted to similar applications such as photovoltaic systems. When comparing the results with the objectives of the doctoral thesis, we may conclude that the objectives set for the work are met. In this doctoral thesis, theoretical and practical guidelines are presented for the successful control design to connect a SOFC-based distributed generation plant to the utility grid.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Permanent magnet drives with nominal power over 10 kW were not a cost-sufficient system 25 years ago due to high material expenses. The improvements in motor drives, the rise in competition and the tightening of standards and regulations have caused that the PM-drives are more and more common in the over 10 kW nominal power range. The goal of this thesis is to research the performance in relation to nominal power of a PM-drive technique that is vastly increasing its popularity in fan related devices. The studied motor technique brushless direct current drive (BLDC) consists of a voltage source inverter, permanent motor and six-step-control. The reference drive is a brushless alternating current drive (BLAC) which consists of a VSI, PM and a hysteresis control. As a conclusion there are no major obstacles that would impede the BLDC-drive technique from expanding to larger power stages. The following factors must be taken into consideration when designing a BLDC-drive: motor’s current change rate, inverter switching frequency, motor’s nominal electric frequency, phase inductance and the current handling capability of the inverter. The fluctuating material costs create instability to the end prices of PM-motors that can in the worst case lead to diminished interest towards BLDC- and PM-drives in general.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This doctoral thesis introduces an improved control principle for active du/dt output filtering in variable-speed AC drives, together with performance comparisons with previous filtering methods. The effects of power semiconductor nonlinearities on the output filtering performance are investigated. The nonlinearities include the timing deviation and the voltage pulse waveform distortion in the variable-speed AC drive output bridge. Active du/dt output filtering (ADUDT) is a method to mitigate motor overvoltages in variable-speed AC drives with long motor cables. It is a quite recent addition to the du/dt reduction methods available. This thesis improves on the existing control method for the filter, and concentrates on the lowvoltage (below 1 kV AC) two-level voltage-source inverter implementation of the method. The ADUDT uses narrow voltage pulses having a duration in the order of a microsecond from an IGBT (insulated gate bipolar transistor) inverter to control the output voltage of a tuned LC filter circuit. The filter output voltage has thus increased slope transition times at the rising and falling edges, with an opportunity of no overshoot. The effect of the longer slope transition times is a reduction in the du/dt of the voltage fed to the motor cable. Lower du/dt values result in a reduction in the overvoltage effects on the motor terminals. Compared with traditional output filtering methods to accomplish this task, the active du/dt filtering provides lower inductance values and a smaller physical size of the filter itself. The filter circuit weight can also be reduced. However, the power semiconductor nonlinearities skew the filter control pulse pattern, resulting in control deviation. This deviation introduces unwanted overshoot and resonance in the filter. The controlmethod proposed in this thesis is able to directly compensate for the dead time-induced zero-current clamping (ZCC) effect in the pulse pattern. It gives more flexibility to the pattern structure, which could help in the timing deviation compensation design. Previous studies have shown that when a motor load current flows in the filter circuit and the inverter, the phase leg blanking times distort the voltage pulse sequence fed to the filter input. These blanking times are caused by excessively large dead time values between the IGBT control pulses. Moreover, the various switching timing distortions, present in realworld electronics when operating with a microsecond timescale, bring additional skew to the control. Left uncompensated, this results in distortion of the filter input voltage and a filter self-induced overvoltage in the form of an overshoot. This overshoot adds to the voltage appearing at the motor terminals, thus increasing the transient voltage amplitude at the motor. This doctoral thesis investigates the magnitude of such timing deviation effects. If the motor load current is left uncompensated in the control, the filter output voltage can overshoot up to double the input voltage amplitude. IGBT nonlinearities were observed to cause a smaller overshoot, in the order of 30%. This thesis introduces an improved ADUDT control method that is able to compensate for phase leg blanking times, giving flexibility to the pulse pattern structure and dead times. The control method is still sensitive to timing deviations, and their effect is investigated. A simple approach of using a fixed delay compensation value was tried in the test setup measurements. The ADUDT method with the new control algorithm was found to work in an actual motor drive application. Judging by the simulation results, with the delay compensation, the method should ultimately enable an output voltage performance and a du/dt reduction that are free from residual overshoot effects. The proposed control algorithm is not strictly required for successful ADUDT operation: It is possible to precalculate the pulse patterns by iteration and then for instance store them into a look-up table inside the control electronics. Rather, the newly developed control method is a mathematical tool for solving the ADUDT control pulses. It does not contain the timing deviation compensation (from the logic-level command to the phase leg output voltage), and as such is not able to remove the timing deviation effects that cause error and overshoot in the filter. When the timing deviation compensation has to be tuned-in in the control pattern, the precalculated iteration method could prove simpler and equally good (or even better) compared with the mathematical solution with a separate timing compensation module. One of the key findings in this thesis is the conclusion that the correctness of the pulse pattern structure, in the sense of ZCC and predicted pulse timings, cannot be separated from the timing deviations. The usefulness of the correctly calculated pattern is reduced by the voltage edge timing errors. The doctoral thesis provides an introductory background chapter on variable-speed AC drives and the problem of motor overvoltages and takes a look at traditional solutions for overvoltage mitigation. Previous results related to the active du/dt filtering are discussed. The basic operation principle and design of the filter have been studied previously. The effect of load current in the filter and the basic idea of compensation have been presented in the past. However, there was no direct way of including the dead time in the control (except for solving the pulse pattern manually by iteration), and the magnitude of nonlinearity effects had not been investigated. The enhanced control principle with the dead time handling capability and a case study of the test setup timing deviations are the main contributions of this doctoral thesis. The simulation and experimental setup results show that the proposed control method can be used in an actual drive. Loss measurements and a comparison of active du/dt output filtering with traditional output filtering methods are also presented in the work. Two different ADUDT filter designs are included, with ferrite core and air core inductors. Other filters included in the tests were a passive du/dtfilter and a passive sine filter. The loss measurements incorporated a silicon carbide diode-equipped IGBT module, and the results show lower losses with these new device technologies. The new control principle was measured in a 43 A load current motor drive system and was able to bring the filter output peak voltage from 980 V (the previous control principle) down to 680 V in a 540 V average DC link voltage variable-speed drive. A 200 m motor cable was used, and the filter losses for the active du/dt methods were 111W–126 W versus 184 W for the passive du/dt. In terms of inverter and filter losses, the active du/dt filtering method had a 1.82-fold increase in losses compared with an all-passive traditional du/dt output filter. The filter mass with the active du/dt method was 17% (2.4 kg, air-core inductors) compared with 14 kg of the passive du/dt method filter. Silicon carbide freewheeling diodes were found to reduce the inverter losses in the active du/dt filtering by 18% compared with the same IGBT module with silicon diodes. For a 200 m cable length, the average peak voltage at the motor terminals was 1050 V with no filter, 960 V for the all-passive du/dt filter, and 700 V for the active du/dt filtering applying the new control principle.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Diplomityössä on tutkittu sähköisellä potkurijärjestelmällä varustetun laivan voimalaitoksen ja jännitevälipiirillisen propulsiokäytön vuorovaikutusta laivan hätäpysäytyksen aikana. Työssä on kehitetty simulointimalleja jännitevälipiirillisten sähkökäyttöjen simuloimiseksi Saber -simulontiohjelmistolla.Työn alkuosassa esitetään lyhyt yhteenveto laivan sähköisestä potkurijärjestelmästä komponentteineen, käsitellään laivan hätäpysäytyksen teoriaa sekä simuloinneissa huomioonotettavia laivan ja potkurin hydrodynaamisia ominaisuuksia. Työssä käytettävän simulointiohjelmiston toimintaa selvitetään lyhyesti. Jännitevälipiirillisellä propulsiokäytöllä varustetun laivan hätäpysäytyksen simulointimalli esitellään kokonaisuudessaan ja käsitellään simulointimallin sisältämien osakokonaisuuksien teoriaa ja toimintaa. Kehitetyn simulointimallin toimintaa on tarkasteltu vertaamalla tuloksia vastaavansyklokonvertterikäytöllä varustetun laivan simulointituloksiin sekä vertaamallasimulointituloksia laivan merikoeajon yhteydessä tehtyihin mittauksiin. Simulointitulokset vastasivat teoriaa sekä mittaustuloksia varsin hyvin. Voimalaitoksenosalta ei mittaustuloksia ollut käytettävissä, mutta simulointitulokset ovat teorian mukaisia.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Pulsewidth-modulated (PWM) rectifier technology is increasingly used in industrial applications like variable-speed motor drives, since it offers several desired features such as sinusoidal input currents, controllable power factor, bidirectional power flow and high quality DC output voltage. To achieve these features,however, an effective control system with fast and accurate current and DC voltage responses is required. From various control strategies proposed to meet these control objectives, in most cases the commonly known principle of the synchronous-frame current vector control along with some space-vector PWM scheme have been applied. Recently, however, new control approaches analogous to the well-established direct torque control (DTC) method for electrical machines have also emerged to implement a high-performance PWM rectifier. In this thesis the concepts of classical synchronous-frame current control and DTC-based PWM rectifier control are combined and a new converter-flux-based current control (CFCC) scheme is introduced. To achieve sufficient dynamic performance and to ensure a stable operation, the proposed control system is thoroughly analysed and simple rules for the controller design are suggested. Special attention is paid to the estimationof the converter flux, which is the key element of converter-flux-based control. Discrete-time implementation is also discussed. Line-voltage-sensorless reactive reactive power control methods for the L- and LCL-type line filters are presented. For the L-filter an open-loop control law for the d-axis current referenceis proposed. In the case of the LCL-filter the combined open-loop control and feedback control is proposed. The influence of the erroneous filter parameter estimates on the accuracy of the developed control schemes is also discussed. A newzero vector selection rule for suppressing the zero-sequence current in parallel-connected PWM rectifiers is proposed. With this method a truly standalone and independent control of the converter units is allowed and traditional transformer isolation and synchronised-control-based solutions are avoided. The implementation requires only one additional current sensor. The proposed schemes are evaluated by the simulations and laboratory experiments. A satisfactory performance and good agreement between the theory and practice are demonstrated.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Line converters have become an attractive AC/DC power conversion solution in industrial applications. Line converters are based on controllable semiconductor switches, typically insulated gate bipolar transistors. Compared to the traditional diode bridge-based power converters line converters have many advantageous characteristics, including bidirectional power flow, controllable de-link voltage and power factor and sinusoidal line current. This thesis considers the control of the lineconverter and its application to power quality improving. The line converter control system studied is based on the virtual flux linkage orientation and the direct torque control (DTC) principle. A new DTC-based current control scheme is introduced and analyzed. The overmodulation characteristics of the DTC converter are considered and an analytical equation for the maximum modulation index is derived. The integration of the active filtering features to the line converter isconsidered. Three different active filtering methods are implemented. A frequency-domain method, which is based on selective harmonic sequence elimination, anda time-domain method, which is effective in a wider frequency band, are used inharmonic current compensation. Also, a voltage feedback active filtering method, which mitigates harmonic sequences of the grid voltage, is implemented. The frequency-domain and the voltage feedback active filtering control systems are analyzed and controllers are designed. The designs are verified with practical measurements. The performance and the characteristics of the implemented active filtering methods are compared and the effect of the L- and the LCL-type line filteris discussed. The importance of the correct grid impedance estimate in the voltage feedback active filter control system is discussed and a new measurement-based method to obtain it is proposed. Also, a power conditioning system (PCS) application of the line converter is considered. A new method for correcting the voltage unbalance of the PCS-fed island network is proposed and experimentally validated.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Induction motors are widely used in industry, and they are generally considered very reliable. They often have a critical role in industrial processes, and their failure can lead to significant losses as a result of shutdown times. Typical failures of induction motors can be classified into stator, rotor, and bearing failures. One of the reasons for a bearing damage and eventually a bearing failure is bearing currents. Bearing currents in induction motors can be divided into two main categories; classical bearing currents and inverter-induced bearing currents. A bearing damage caused by bearing currents results, for instance, from electrical discharges that take place through the lubricant film between the raceways of the inner and the outer ring and the rolling elements of a bearing. This phenomenon can be considered similar to the one of electrical discharge machining, where material is removed by a series of rapidly recurring electrical arcing discharges between an electrode and a workpiece. This thesis concentrates on bearing currents with a special reference to bearing current detection in induction motors. A bearing current detection method based on radio frequency impulse reception and detection is studied. The thesis describes how a motor can work as a “spark gap” transmitter and discusses a discharge in a bearing as a source of radio frequency impulse. It is shown that a discharge, occurring due to bearing currents, can be detected at a distance of several meters from the motor. The issues of interference, detection, and location techniques are discussed. The applicability of the method is shown with a series of measurements with a specially constructed test motor and an unmodified frequency-converter-driven motor. The radio frequency method studied provides a nonintrusive method to detect harmful bearing currents in the drive system. If bearing current mitigation techniques are applied, their effectiveness can be immediately verified with the proposed method. The method also gives a tool to estimate the harmfulness of the bearing currents by making it possible to detect and locate individual discharges inside the bearings of electric motors.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Huoli ympäristön tilasta ja fossiilisten polttoaineiden hinnan nousu ovat vauhdittaneet tutkimusta uusien energialähteiden löytämiseksi. Polttokennot ovat yksi lupaavimmista tekniikoista etenkin hajautetun energiantuotannon, varavoimalaitosten sekä liikennevälineiden alueella. Polttokenno on tehonlähteenä kuitenkin hyvin epäideaalinen, ja se asettaa tehoelektroniikalle lukuisia erityisvaatimuksia. Polttokennon kytkeminen sähköverkkoon on tavallisesti toteutettu käyttämällä galvaanisesti erottavaa DC/DC hakkuria sekä vaihtosuuntaajaa sarjassa. Polttokennon kulumisen estämiseksi tehoelektroniikalta vaaditaan tarkkaa polttokennon lähtövirran hallintaa. Perinteisesti virran hallinta on toteutettu säätämällä hakkurin tulovirtaa PI (Proportional and Integral) tai PID (Proportional, Integral and Derivative) -säätimellä. Hakkurin epälineaarisuudesta johtuen tällainen ratkaisu ei välttämättä toimi kaukana linearisointipisteestä. Lisäksi perinteiset säätimet ovat herkkiä mallinnusvirheille. Tässä diplomityössä on esitetty polttokennon jännitettä nostavan hakkurin tilayhtälökeskiarvoistusmenetelmään perustuva malli, sekä malliin perustuva diskreettiaikainen integroiva liukuvan moodin säätö. Esitetty säätö on luonteeltaan epälineaarinen ja se soveltuu epälineaaristen ja heikosti tunnettujen järjestelmien säätämiseen.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The development of bioenergy on the basis of wood fuels has received considerable attention in the last decades. The combination of large forest resources and reliance on fossil fuels makes the issue of wood chips usage in Russia an actual topic for the analysis. The main objective of this study is to disclose the current state and perspectives for the production of wood chips and their usage as a source of energy in the North-West of Russia. The study utilizes an integrated approach to explore the market of wood chips on the basis of comprehensive analysis of documentation and expert opinions. The analysis of wood chips market was performed for eight regions of the North-West district of Russia within two major dimensions: its current state and perspectives in the nearest five years. The results of the study show a comprehensive picture of the wood chips market, including the potential for wood chips production, the specific features of production and consumption and the perspectives for the market development within the regions of the North-West district of Russia. The study demonstrated that the market of wood chips is underdeveloped in the North-West of Russia. The findings of the work may be used by forest companies for the strategic planning.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Frequency converters are widely used in the industry to enable better controllability and efficiency of variable speed AC motor drives. Despite these advantages, certain challenges concerning the inverter and motor interfacing have been present for decades. As insulated gate bipolar transistors entered the market, the inverter output voltage transition rate significantly increased compared with their predecessors. Inverters operate based on pulse width modulation of the output voltage, and the steep voltage edge fed by the inverter produces a motor terminal overvoltage. The overvoltage causes extra stress to the motor insulation, which may lead to a prematuremotor failure. The overvoltage is not generated by the inverter alone, but also by the sum effect of the motor cable length and the impedance mismatch between the cable and the motor. Many solutions have been shown to limit the overvoltage, and the mainstream products focus on passive filters. This doctoral thesis studies an alternative methodology for motor overvoltage reduction. The focus is on minimization of the passive filter dimensions, physical and electrical, or better yet, on operation without any filter. This is achieved by additional inverter control and modulation. The studied methods are implemented on different inverter topologies, varying in nominal voltage and current.For two-level inverters, the studied method is termed active du/dt. It consists of a small output LC filter, which is controlled by an independent modulator. The overvoltage is limited by a reduced voltage transition rate. For multilevel inverters, an overvoltage mitigation method operating without a passive filter, called edge modulation, is implemented. The method uses the capability of the inverter to produce two switching operations in the same direction to cancel the oscillating voltages of opposite phases. For parallel inverters, two methods are studied. They are both intended for two-level inverters, but the first uses individual motor cables from each inverter while the other topology applies output inductors. The overvoltage is reduced by interleaving the switching operations to produce a similar oscillation accumulation as with the edge modulation. The implementation of these methods is discussed in detail, and the necessary modifications to the control system of the inverter are presented. Each method is experimentally verified by operating industrial frequency converters with the modified control. All the methods are found feasible, and they provide sufficient overvoltage protection. The limitations and challenges brought about by the methods are discussed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fuel cells are a promising alternative for clean and efficient energy production. A fuel cell is probably the most demanding of all distributed generation power sources. It resembles a solar cell in many ways, but sets strict limits to current ripple, common mode voltages and load variations. The typically low output voltage from the fuel cell stack needs to be boosted to a higher voltage level for grid interfacing. Due to the high electrical efficiency of the fuel cell, there is a need for high efficiency power converters, and in the case of low voltage, high current and galvanic isolation, the implementation of such converters is not a trivial task. This thesis presents galvanically isolated DC-DC converter topologies that have favorable characteristics for fuel cell usage and reviews the topologies from the viewpoint of electrical efficiency and cost efficiency. The focus is on evaluating the design issues when considering a single converter module having large current stresses. The dominating loss mechanism in low voltage, high current applications is conduction losses. In the case of MOSFETs, the conduction losses can be efficiently reduced by paralleling, but in the case of diodes, the effectiveness of paralleling depends strongly on the semiconductor material, diode parameters and output configuration. The transformer winding losses can be a major source of losses if the windings are not optimized according to the topology and the operating conditions. Transformer prototyping can be expensive and time consuming, and thus it is preferable to utilize various calculation methods during the design process in order to evaluate the performance of the transformer. This thesis reviews calculation methods for solid wire, litz wire and copper foil winding losses, and in order to evaluate the applicability of the methods, the calculations are compared against measurements and FEM simulations. By selecting a proper calculation method for each winding type, the winding losses can be predicted quite accurately before actually constructing the transformer. The transformer leakage inductance, the amount of which can also be calculated with reasonable accuracy, has a significant impact on the semiconductor switching losses. Therefore, the leakage inductance effects should also be taken into account when considering the overall efficiency of the converter. It is demonstrated in this thesis that although there are some distinctive differences in the loss distributions between the converter topologies, the differences in the overall efficiency can remain within a range of a few percentage points. However, the optimization effort required in order to achieve the high efficiencies is quite different in each topology. In the presence of practical constraints such as manufacturing complexity or cost, the question of topology selection can become crucial.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pulssinleveysmoduloidun vaihtosuuntaajan hyötysuhteen parantaminen ja kytkentätaajuuden suurentaminen ovat johtaneet lähtöjännitteen suuritaajuiseen taajuussisältöön kaksitasoisessa, jännitevälipiirillisessä taajuusmuuttajatopologiassa. Kasvava tarve siirtää tehoa myös verkkoon päin on lisännyt aktiivisen verkkosillan käyttöä. Kaksitasoisen aktiivisen verkkosillan vaikutuksesta DC-välipiirin keskipisteen ja kolmivaiheisen kuorman tähtipisteen välinen jännite on nollasta poikkeava aiheuttaen suurentuneen yhteismuotoisen jännitteen taajuusmuuttajan lähtöön ja verkon puolelle. Lisäksi yhteismuotoisten jännitteiden aiheuttamat kytkentätaajuiset häiriövirrat voivat aiheuttaa vikavirtasuojien tahatonta laukeamista, vaikeuttaa EMC-standardien vaatimusten täyttämistä, lisätä moottorin käämieristyksien rasitusta ja mahdollisuutta moottorin laakerivaurioille. Diplomityössä tutkitaan aktiivisen ja passiivisen verkkosillan tuottamaa yhteismuotoista jännitettä simuloinneilla. Esitellään aikaisempaa tutkimustietoa yhteismuotoisen jännitteen ja virran vaimennusratkaisuista aktiivista verkkosiltaa käytettäessä. Tutkimustiedon pohjalta suunnitellaan koelaitteistolle soveltuva suodin. Suotimen toiminta testataan simuloinnein sekä kokeellisin mittauksin. Tehdyt mittaukset osoittavat, että suunniteltu suodin vaimentaa yhteismuotoista jännitettä noin 20 dB verkkosillan kytkentätaajuudella ja tämän jälkeen yli 20 dB/dekadi taajuuteen 100 kHz asti. Lisäksi yhteismuotoisen virran suuruus syöttökaapelin kautta pieneni ehdotetun suotimen vaikutuksesta.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The power rating of wind turbines is constantly increasing; however, keeping the voltage rating at the low-voltage level results in high kilo-ampere currents. An alternative for increasing the power levels without raising the voltage level is provided by multiphase machines. Multiphase machines are used for instance in ship propulsion systems, aerospace applications, electric vehicles, and in other high-power applications including wind energy conversion systems. A machine model in an appropriate reference frame is required in order to design an efficient control for the electric drive. Modeling of multiphase machines poses a challenge because of the mutual couplings between the phases. Mutual couplings degrade the drive performance unless they are properly considered. In certain multiphase machines there is also a problem of high current harmonics, which are easily generated because of the small current path impedance of the harmonic components. However, multiphase machines provide special characteristics compared with the three-phase counterparts: Multiphase machines have a better fault tolerance, and are thus more robust. In addition, the controlled power can be divided among more inverter legs by increasing the number of phases. Moreover, the torque pulsation can be decreased and the harmonic frequency of the torque ripple increased by an appropriate multiphase configuration. By increasing the number of phases it is also possible to obtain more torque per RMS ampere for the same volume, and thus, increase the power density. In this doctoral thesis, a decoupled d–q model of double-star permanent-magnet (PM) synchronous machines is derived based on the inductance matrix diagonalization. The double-star machine is a special type of multiphase machines. Its armature consists of two three-phase winding sets, which are commonly displaced by 30 electrical degrees. In this study, the displacement angle between the sets is considered a parameter. The diagonalization of the inductance matrix results in a simplified model structure, in which the mutual couplings between the reference frames are eliminated. Moreover, the current harmonics are mapped into a reference frame, in which they can be easily controlled. The work also presents methods to determine the machine inductances by a finite-element analysis and by voltage-source inverters on-site. The derived model is validated by experimental results obtained with an example double-star interior PM (IPM) synchronous machine having the sets displaced by 30 electrical degrees. The derived transformation, and consequently, the decoupled d–q machine model, are shown to model the behavior of an actual machine with an acceptable accuracy. Thus, the proposed model is suitable to be used for the model-based control design of electric drives consisting of double-star IPM synchronous machines.