18 resultados para Cross-flow
em Doria (National Library of Finland DSpace Services) - National Library of Finland, Finland
Resumo:
Transitional flow past a three-dimensional circular cylinder is a widely studied phenomenon since this problem is of interest with respect to many technical applications. In the present work, the numerical simulation of flow past a circular cylinder, performed by using a commercial CFD code (ANSYS Fluent 12.1) with large eddy simulation (LES) and RANS (κ - ε and Shear-Stress Transport (SST) κ - ω! model) approaches. The turbulent flow for ReD = 1000 & 3900 is simulated to investigate the force coefficient, Strouhal number, flow separation angle, pressure distribution on cylinder and the complex three dimensional vortex shedding of the cylinder wake region. The numerical results extracted from these simulations have good agreement with the experimental data (Zdravkovich, 1997). Moreover, grid refinement and time-step influence have been examined. Numerical calculations of turbulent cross-flow in a staggered tube bundle continues to attract interest due to its importance in the engineering application as well as the fact that this complex flow represents a challenging problem for CFD. In the present work a time dependent simulation using κ – ε, κ - ω! and SST models are performed in two dimensional for a subcritical flow through a staggered tube bundle. The predicted turbulence statistics (mean and r.m.s velocities) have good agreement with the experimental data (S. Balabani, 1996). Turbulent quantities such as turbulent kinetic energy and dissipation rate are predicted using RANS models and compared with each other. The sensitivity of grid and time-step size have been analyzed. Model constants sensitivity study have been carried out by adopting κ – ε model. It has been observed that model constants are very sensitive to turbulence statistics and turbulent quantities.
Resumo:
Tämän työn tavoitteena oli selvittää erään ilmanvaihtokoneen lämmöntalteenottokennon vuosihyötysuhde japohtia voitaisiinko ilmastointikoneen energiatehokkuutta parantaa käyttämällä nykyisen ristivirtalämmönsiirtimen tilalla vastavirtalämmönsiirrintä tai poistoilmalämpöpumppua. Lisäksi tavoitteena oli mitata kahden ilmanvaihtokoneeseen liitettävän äänenvaimentimen vaimennuskyky ja pyrkiä parantamaan näiden vaimennusta. Työn teoriaosassa käsitellään yleisellä tasolla eri ilmanvaihtotapojen ja lämmöntalteenottomenetelmien toimintaperiaatteita ja soveltuvuuksiaeri tilanteisiin. Työn kokeellisessa osassa mitataan ilmanvaihtokoneen lämmöntalteenoton toiminta eri sääolosuhteissa ja lasketaan tulosten perusteella laitteelle lämpötila- ja entalpiavuosihyötysuhteet. Äänenvaimentimesta rakennetaan kaksi kehitysversiota, joiden mittaustuloksia verrataan alkuperäisen vaimentimen vaimennuskykyyn. Lämmöntalteenottoja vertailtaessa havaittiin, että suositeltavin kehitysvaihtoehto olisi vastavirtalämmönsiirtimeen siirtyminen sen yksinkertaisen rakenteen ja hyvän hyötysuhteen ansiosta.Äänenvaimentimien rakenteessa kannattaa mittausten ja pohdinnan perusteella siirtyä seinämillä jaettuun vaimentimeen.
Resumo:
In this thesis the membrane filtration equipment for plate type ceramic membranes was developed based on filtration results achieved with different kinds of wastewaters. The experiments were mainly made with pulp and board mill wastewaters, but some experiments were also made with a bore well water and a stone cutting mine wastewater. The ceramicmembranes used were alpha-alumina membranes with a pore size of 100 nm. Some ofthe membranes were coated with a gamma-alumina layer to reduce the membrane pore size to 10 nm, and some of them were modified with different metal oxides in order to change the surface properties of the membranes. The effects of operationparameters, such as cross-flow velocity, filtration pressure and backflushing on filtration performance were studied. The measured parameters were the permeateflux, the quality of the permeate, as well as the fouling tendency of the membrane. A dynamic membrane or a cake layer forming on top of the membrane was observed to decrease the flux and increase separa-tion of certain substances, especially at low cross-flow velocities. When the cross-flow velocities were increased the membrane properties became more important. Backflushing could also be used to decrease the thickness of the cake layer and thus it improved the permeate flux. However, backflushing can lead to a reduction of retentions in cases where the cake layer is improving them. The wastewater quality was important for the thickness of the dynamic membrane and the membrane pore size influenced the permeate flux. In general, the optimization of operation conditions is very important for the successful operation of a membrane filtration system. The filtration equipment with a reasonable range of operational conditions is necessary, especiallywhen different kinds of wastewaters are treated. This should be taken into account already in the development stage of a filtration equipment.
Resumo:
In this thesis different parameters influencing critical flux in protein ultrafiltration and membrane foul-ing were studied. Short reviews of proteins, cross-flow ultrafiltration, flux decline and criticalflux and the basic theory of Partial Least Square analysis (PLS) are given at the beginning. The experiments were mainly performed using dilute solutions of globular proteins, commercial polymeric membranes and laboratory scale apparatuses. Fouling was studied by flux, streaming potential and FTIR-ATR measurements. Critical flux was evaluated by different kinds of stepwise procedures and by both con-stant pressure and constant flux methods. The critical flux was affected by transmembrane pressure, flow velocity, protein concentration, mem-brane hydrophobicity and protein and membrane charges. Generally, the lowest critical fluxes were obtained at the isoelectric points of the protein and the highest in the presence of electrostatic repulsion between the membrane surface and the protein molecules. In the laminar flow regime the critical flux increased with flow velocity, but not any more above this region. An increase in concentration de-creased the critical flux. Hydrophobic membranes showed fouling in all charge conditionsand, furthermore, especially at the beginning of the experiment even at very low transmembrane pressures. Fouling of these membranes was thought to be due to protein adsorption by hydrophobic interactions. The hydrophilic membranes used suffered more from reversible fouling and concentration polarisation than from irreversible foul-ing. They became fouled at higher transmembrane pressures becauseof pore blocking. In this thesis some new aspects on critical flux are presented that are important for ultrafiltration and fractionation of proteins.
Resumo:
Työn tarkoituksena oli kehittää kerrosleijukattilan sekundääri-ilmansyöttöä. Työssä tutkittiin tulipesässä ilmasuihkujen käyttäytymiseen vaikuttavia tekijöitä sekä eri ilmansyöttömallien vaikutuksia tulipesäolosuhteisiin. Sekundääri- ja tertiääri-ilmasuihkujen tehtävänä on sekoittaa tulipesän kaasuja sekä tuoda happi leijupetin yläpuolelle haihtuneiden aineiden palamisen loppuun saattamiseksi. Kaasujen sekoittumiseen vaikuttavat ilmasuihkun ja ristivirtauksen liikemäärien suhde, suutinten koko ja sijoittelu toisiinsa nähden. Ilmasuihku saavuttaa paremman tunkeutuvuuden ja siten tehokkaamman sekoittumisen suuttimen koon kasvaessa. Lisäksi tunkeutuvuus paranee suutinten välisen etäisyyden sekä ilmasuihkun ja ristivirtauksen liikemäärien suhteen kasvaessa. Optimaalisen suutinten välisen etäisyyden osoitettiin riippuvan suuttimen ja tulipesän koosta sekä ilmasuihkun ja ristivirtauksen liikemäärien suhteesta. Saatujen tulosten mukaan sekundääri- ja tertiääri-ilmatasoilla tulee suosia suuria harvaan ja lomittain sijoitettuja suuttimia. Ilmansyöttömalleja tutkittiin numeerisesti mallintamalla, ja saatujen tulosten perusteella tehokkain sekoittuminen saavutettiin sijoittamalla sekundääri-ilmasuuttimet tulipesän kahdelle vastakkaiselle seinälle.
Resumo:
Työssä selvitettiin suodatusolosuhteiden vaikutusta neutraalien polymeerien pidättymiseen niiden vesiliuoksia suodatettaessa. Suodatuksissa käytettiin kahta regeneroidusta selluloosasta valmistettua ultrasuodatuskalvoa (Microdyn-Nadir UC 030T ja JSC STC Vladipor C 30V). Malliaineina käytettiin polyetyleeniglykolia ja dekstraania. Kirjallisuusosassa esiteltiin aluksi lyhyesti ultrasuodatus erotusmenetelmänä. Lisäksi käsiteltiin ultrasuodatuskalvojen huokoskoon karakterisointimenetelmiä ja selvitettiin polymeerien erottumiseen ultrasuodatuksen aikana vaikuttavia tekijöitä. Työn kokeellisessa osassa tutkittiin paineen ja virtausnopeuden vaikutusta malliaineiden pidättymiseen ultrasuodatuskalvoilla. Lisäksi pyrittiin löytämään suodatusolosuhteet, joissa toinen aineista läpäisisi suodatuskalvon lähes täydellisesti toisen konsentroituessa syöttöliuokseen. Työssä myös määritettiin tutkimuksissa käytetyille kalvoille katkaisukoko, joka kuvaa kalvon kykyä pidättää moolimassaltaan erikokoisia molekyylejä. Lisäksi kokeellisessa osassa selvitettiin työssä käytettyjen kalvojen tasalaatuisuutta vertailemalla keskenään samanlaisissa suodatusolosuhteissa eri kalvopaloilla tehtyjen suodatusten tuloksia. Työssä saatiin erotettua kaksi lähes samankokoista malliaineeksi valittua neutraalia polymeeriä toisistaan siten, että toinen aine pidättyi kalvolla huomattavasti toista ainetta paremmin. Parhaimpaan erotustulokseen päästiin, kun permeaattivuo kalvon läpi oli noin 400 l/(m2 h). Tällöin suodatuspaine oli noin 2 bar ja virtausnopeus alle 2 m/s. Työn aikana määritettyjen katkaisukokojen havaittiin poikkeavan huomattavasti kalvojen valmistajien ilmoittamista arvoista, mutta olevan kuitenkin samaa suuruusluokkaa kuin muiden tutkimusryhmien vastaaville ultrasuodatuskalvoille esittämät arvot. Työn tulosten perusteella C 30V olisi hieman tasalaatuisempi kalvo kuin UC 030T.
Resumo:
Streaming potential measurements for the surface charge characterisation of different filter media types and materials were used. The equipment was developed further so that measurements could be taken along the surfaces, and so that tubular membranes could also be measured. The streaming potential proved to be a very useful tool in the charge analysis of both clean and fouled filter media. Adsorption and fouling could be studied, as could flux, as functions of time. A module to determine the membrane potential was also constructed. The results collected from the experiments conducted with these devices were used in the study of the theory of streaming potential as an electrokinetic phenomenon. Several correction factors, which are derived to take into account the surface conductance and the electrokinetic flow in very narrow capillaries, were tested in practice. The surface materials were studied using FTIR and the results compared with those from the streaming potentials. FTIR analysis was also found to be a useful tool in the characterisation of filters, as well as in the fouling studies. Upon examination of the recorded spectra from different depths in a sample it was possible to determine the adsorption sites. The influence of an external electric field on the cross flow microflltration of a binary protein system was investigated using a membrane electroflltration apparatus. The results showed that a significant improvement could be achieved in membrane filtration by using the measured electrochemical properties to help adjust the process conditions.
Resumo:
In many industries, such as petroleum production, and the petrochemical, metal, food and cosmetics industries, wastewaters containing an emulsion of oil in water are often produced. The emulsions consist of water (up to 90%), oils (mineral, animal, vegetable and synthetic), surfactants and other contaminates. In view of its toxic nature and its deleterious effects on the surrounding environment (soil, water) such wastewater needs to be treated before release into natural water ways. Membrane-based processes have successfully been applied in industrial applications and are considered as possible candidates for the treatment of oily wastewaters. Easy operation, lower cost, and in some cases, the ability to reduce contaminants below existing pollution limits are the main advantages of these systems. The main drawback of membranes is flux decline due tofouling and concentration polarisation. The complexity of oil-containing systems demands complementary studies on issues related to the mitigation of fouling and concentration polarisation in membranebased ultrafiltration. In this thesis the effect of different operating conditions (factors) on ultrafiltration of oily water is studied. Important factors are normally correlated and, therefore, their effect should be studied simultaneously. This work uses a novel approach to study different operating conditions, like pressure, flow velocity, and temperature, and solution properties, like oil concentration (cutting oil, diesel, kerosene), pH, and salt concentration (CaCl2 and NaCl)) in the ultrafiltration of oily water, simultaneously and in a systematic way using an experimental design approach. A hypothesis is developed to describe the interaction between the oil drops, salt and the membrane surface. The optimum conditions for ultrafiltration and the contribution of each factor in the ultrafiltration of oily water are evaluated. It is found that the effect on permeate flux of the various factors studied strongly depended on the type of oil, the type of membrane and the amount of salts. The thesis demonstrates that a system containing oil is very complex, and that fouling and flux decline can be observed even at very low pressures. This means that only the weak form of the critical flux exists for such systems. The cleaning of the fouled membranes and the influence of different parameters (flow velocity, temperature, time, pressure, and chemical concentration (SDS, NaOH)) were evaluated in this study. It was observed that fouling, and consequently cleaning, behaved differently for the studied membranes. Of the membranes studied, the membrane with the lowest propensity for fouling and the most easily cleaned was the regenerated cellulose membrane (C100H). In order to get more information about the interaction between the membrane and the components of the emulsion, a streaming potential study was performed on the membrane. The experiments were carried out at different pH and oil concentration. It was seen that oily water changed the surface charge of the membrane significantly. The surface charge and the streaming potential during different stages of filtration were measured and analysed being a new method for fouling of oil in this thesis. The surface charge varied in different stages of filtration. It was found that the surface charge of a cleaned membrane was not the same as initially; however, the permeability was equal to that of a virgin membrane. The effect of filtration mode was studied by performing the filtration in both cross-flow and deadend mode. The effect of salt on performance was considered in both studies. It was found that salt decreased the permeate flux even at low concentration. To test the effect of hydrophilicity change, the commercial membranes used in this thesis were modified by grafting (PNIPAAm) on their surfaces. A new technique (corona treatment) was used for this modification. The effect of modification on permeate flux and retention was evaluated. The modified membranes changed their pore size around 33oC resulting in different retention and permeability. The obtained results in this thesis can be applied to optimise the operation of a membrane plant under normal or shock conditions or to modify the process such that it becomes more efficient or effective.
Resumo:
Hydroksihapoille on olemassa useita käyttömahdollisuuksia teollisuudessa, joten niiden hyödyntäminen sellunvalmistuksen sivuvirrasta eli mustalipeästä on suuren kiinnostuksen kohteena. Tässä työssä selvitettiin, onko hydroksihappojen erotus ja puhdistus mustalipeästä mahdollista nanosuodatuksella. Kokeellisessa osassa suodatettiin emäksisen mustalipeän lisäksi hapotettua ja jäähdytyskiteytettyä mustalipeää, johon oli lisätty liuotinta. Mustalipeäsuodatuksissa käytettiin viittä erilaista nanosuodatusmembraania (Microdyn Nadir® NP010 ja NP030, Dow Chemical Company NF-90, Woongjin Chemical NE-70 sekä Ge-Osmonics Desal 5 DK). Kirjallisuusosassa käsiteltiin puun sisältämien yhdisteiden kemiallista koostumusta, sellun valmistuksen pääperiaatteita, mustalipeän ja hydroksihappojen ominaisuuksia sekä hydroksihappojen käyttömahdollisuuksia. Lisäksi tarkasteltiin erilaisia hydroksihappojen erotusmenetelmiä, nanosuodatuksen teoriaa ja prosessiin sopivan membraanin valintakriteerejä. Työn kokeellisessa osassa tutkittiin emäksisen mustalipeän monivaiheisen nanosuodatuksen tehokkuutta hydroksihappojen erotuksessa. Hapotetun ja jäähdytyskiteytetyn mustalipeän suodatuskokeissa tutkittiin erityyppisten membraanien erotuskykyä sekä syötön liuotinlisäyksen vaikutusta hydroksihappojen erottumiseen. Lisäksi tarkasteltiin membraanien kestävyyttä ja foulaantumista suodatusolosuhteissa. Työn tulokset osoittivat, että hydroksihappoja voidaan fraktioida mustalipeästä nanosuodatuksella. Hydroksihappojen fraktiointiin vaikuttaa merkittävästi mustalipeässä käytetyn liuottimen läsnäolo sekä suodatuspaine. Lisäksi koetulosten perusteella havaittiin, että monivaiheisella nanosuodatuksella hydroksihapot läpäisevät membraanin ja permeaattiin saavutetaan puhtaampi happojae.
Resumo:
Työn tarkoituksena oli tutkia arvometalleja sisältävän liuoksen puhdistamista jat-kuvatoimisella ioninvaihdolla. Teoriaosassa käsitellään ioninvaihdon periaate, sekä jatkuvatoimisen ioninvaihdon laiteratkaisuja ristivirta- ja vastavirtasysteemeissä. Lopuksi esitellään Simuloidun liikkuvapedin (SMB) virtausnopeuksien laske-miseksi käytettävä kolmiomenetelmä. Kokeellisen osan tarkoituksena on demonstroida laboratorioon rakennetun jatku-vatoimisen ioninvaihtimen, Simuloidun liikkuvapedin, käyttö arvometallia sisäl-tävän liuoksen puhdistamiseksi kahdenarvoisista metalli-ioneista. Kokeissa käy-tettiin hopeaa sisältävää NaCl-liuosta, josta pyrittiin puhdistamaan Mg2+, Ca2+, Pb2+ ja Zn2+-ionit ekstraktina. Laitteistolla suoritettiin kolme ajoa, joista kaksi edusti vastavirtasysteemiä ja yksi ristivirtasysteemiä. Ensimmäisessä vastavirta-ajossa sekä ekstrakti että raffinaattin erottuva hopealiuos tulivat puhtaina. Toisessa vastavirta-ajossa pyrittiin parantamaan tuottavuutta nostamalla syötön virtausnopeutta, jolloin raffinaatin puhtaus kärsi Pb2+ ja Mg2+-ionien kulkeutuessa liuosfaasin mukana raffinaattiin. Ristivirta-ajossa vain yksi kolmesta raffinaatista saavutti 100 % puhtauden. Kokeet osoittivat, että Mg2+, Ca2+, Pb2+ ja Zn2+-ionien erottaminen hopeaionista on mahdollista käyttämällämme SMB-laitteistolla. Tuottavuuden parantaminen syötön virtausnopeutta nostamalla kuitenkin heikentää puhtautta. Cross-flow-systeemin erilleenkytkettyjen kolonnien ansioista painehäviö on pienempi, mikä mahdollistaa korkeammat virtausnopeudet, mikäli ei vaadita 100 % puhtautta.
Resumo:
Työssä selvitettiin uudenaikaisten polymeerikalvojen soveltuvuutta maidon sekä heran mikrosuodatukseen. Kirjallisessa osassa perehdyttiin maidon ja heran koostumuksiin, mikrobikantoihin sekä erilaisiin maidon sekä heran rasvanpoisto- ja puhdistusmenetelmiin. Tämän lisäksi käsiteltiin mikrosuodatusmenetelmiä sekä niiden käyttöä heran ja maidon käsittelyssä meijeriteollisuudessa. Kokeellisessa osassa verrattiin kahdella eri suodatuslaitteistolla keraami- ja polymeerikalvojen suodatusominaisuuksia separoidun raakamaidon sekä heran poikkivirtausmikrosuodatuksessa. Tavoitteena oli erottaa suodatettavista liuoksista mikrobit sekä jäännösrasva ja tuottaa puhdasta, proteiinipitoista maitoa / heraa. Koeajoissa otetuista näytteistä analysoitiin ainesosakoostumus sekä mikrobipitoisuudet. Tuloksista määritettiin retentioarvot ja näiden perusteella vertailtiin polymeeri- ja keraamikalvojen erotustehokkuutta. Lisäksi kalvojen toimivuutta arvioitiin vuoarvojen avulla. Raakamaidon suodatuksissa polymeerikalvot pidättivät täydellisesti tai lähes täydellisesti jäännösrasvan ja mikrobit, mutta myös kaseiiniproteiinin. Tästä syystä yksikään polymeerikalvoista ei sovellu puhtaan maidon suodatukseen. Keraamikalvot soveltuvat tähän selkeästi paremmin ja yksikään toinen testatuista kalvoista ei päässyt samalle tasolle meijeriteollisuudessa jo käytössä olevan Membralox 1,4 μm -keraamikalvon kanssa. Heran suodatuksissa polymeerikalvot pidättivät täydellisesti tai lähes täydellisesti rasvan ja mikrobit, mutta keraamikalvo päästi huomattavasti enemmän haluttuja proteiineja permeaattiin. Membralox 0,8 μm -keraamikalvo pidätti täydellisesti mikrobit, mutta päästi jonkin verran jäännösrasvaa permeaattiin. Näin ollen kalvovalinta on kompromissi permeaatin puhtauden ja proteiinin saannon välillä. Keraamikalvojen vuohäviöt olivat merkittävästi pienemmät kuin polymeerikalvoilla molempien syöttöliuosten kanssa. Lisäksi keraamikalvojen puhdistus oli huomattavasti nopeampaa ja helpompaa. Tästä syystä keraamiset kalvot soveltuvat polymeerisiä paremmin maidon ja heran mikrosuodatukseen.
Resumo:
Alfa Laval Aalborg Oy designs and manufactures waste heat recovery systems utilizing extended surfaces. The waste heat recovery boiler considered in this thesis is a water-tube boiler where exhaust gas is used as the convective heat transfer medium and water or steam flowing inside the tubes is subject to cross-flow. This thesis aims to contribute to the design of waste heat recovery boiler unit by developing a numerical model of the H-type finned tube bundle currently used by Alfa Laval Aalborg Oy to evaluate the gas-side heat transfer performance. The main objective is to identify weaknesses and potential areas of development in the current H-type finned tube design. In addition, numerical simulations for a total of 15 cases with varying geometric parameters are conducted to investigate the heat transfer and pressure drop performance dependent on H-type fin geometry. The investigated geometric parameters include fin width and height, fin spacing, and fin thickness. Comparison between single and double tube type configuration is also conducted. Based on the simulation results, the local heat transfer and flow behaviour of the H-type finned tube is presented including boundary layer development between the fins, the formation of recirculation zone behind the tubes, and the local variations of flow velocity and temperature within the tube bundle and on the fin surface. Moreover, an evaluation of the effects of various fin parameters on heat transfer and pressure drop performance of H-type finned tube bundle has been provided. It was concluded that from the studied parameters fin spacing and fin width had the most significant effect on tube bundle performance and the effect of fin thickness was the least important. Furthermore, the results suggested that the heat transfer performance would increase due to enhanced turbulence if the current double tube configuration is replaced with single tube configuration, but further investigation and experimental measurements are required in order to validate the results.
Resumo:
Lääkeaineiden poistaminen jätevedestä on tärkeää lääkeainejäämien ympäristöön pääsyn ehkäisemiseksi. Tämän työn tavoitteena on selvittää, soveltuvatko katalyyttiset membraanit lääkeaineiden poistoon jätevedestä ja saadaanko membraanisuodatusta tehostettua katalyyttisellä prosessilla. Työ käsittelee katalyyttisistä prosesseista fotokatalyysiä, joka perustuu valoa absorboivan katalyytin käyttöön. Kirjallisuustyössä tarkastellaan kahden erilaisen fotokatalyyttisen prosessin toimivuutta membraanisuodatuksen kanssa lääkeaineiden poistossa jätevedestä. Lisäksi tutkitaan fotokatalyysissä käytettävän katalyytin ja ultraviolettisäteilyn vaikutusta membraaniin. Tutkimukset ovat osoittaneet, että katalyyttisillä membraaneilla voidaan poistaa lääkeaineita jätevedestä tehokkaasti. Parhaan lääkeaineiden poistotehokkuuden saamiseksi katalyytin määrä on optimoitava hajotusprosessin kannalta. Myös katalyytin sijainti membraanissa vaikuttaa tehokkuuteen. Katalyytti voi sijaita membraanista myös erillään. Tällöin saadaan käsiteltyä myös jatkuvatoimisessa membraanisuodatuksessa syntyvä lääkeaineita sisältävä konsentraattivirta. Kun katalyyttisellä membraanilla hajotetaan lääkeaineita, täytyy prosessin turvallisuuden kannalta olla hyvin selvillä mahdollisista syntyvistä myrkyllisistä välituotteista. Tutkimuksissa on myös todettu, että katalyyttisen membraanin käyttö vähentää membraanin likaantumista.
Resumo:
Previous studies have demonstrated that clinical pulpal pain can induce the expression of pro-inflammatory neuropeptides in the adjacent gingival crevice fluid (GCF). Vasoactive agents such as substance P (SP) are known to contribute to the inflammatory type of pain and are associated with increased blood flow. More recent animal studies have shown that application of capsaicin on alveolar mucosa provokes pain and neurogenic vasodilatation in the adjacent gingiva. Pain-associated inflammatory reactions may initiate expression of several pro- and anti-inflammatory mediators. Collagenase-2 (MMP-8) has been considered to be the major destructive protease, especially in the periodontitis-affected gingival crevice fluid (GCF). MMP-8 originates mostly from neutrophil leukocytes, the first line of defence cells that exist abundantly in GCF, especially in inflammation. With this background, we wished to clarify the spatial extensions and differences between tooth-pain stimulation and capsaicin-induced neurogenic vasodilatation in human gingiva. Experiments were carried out to study whether tooth stimulation and capsaicin stimulation of alveolar mucosa would induce changes in GCF MMP-8 levels and whether tooth stimulation would release neuropeptide SP in GCF. The experiments were carried out on healthy human volunteers. During the experiments, moderate and high intensity painful tooth stimulation was performed by a constant current tooth stimulator. Moderate tooth stimulation activates A-delta fibres, while high stimulation also activates C-fibres. Painful stimulation of the gingiva was achieved by topical application of capsaicin-moistened filter paper on the mucosal surface. Capsaicin is known to activate selectively nociceptive C-fibres of stimulated tissue. Pain-evoked vasoactive changes in gingivomucosal tissues were mapped by laser Doppler imaging (LDI), which is a sophisticated and non-invasive method for studying e.g. spatial and temporal characteristics of pain- and inflammation-evoked blood flow changes in gingivomucosal tissues. Pain-evoked release of MMP-8 in GCF samples was studied by immunofluorometric assay (IFMA) and Western immunoblotting. The SP levels in GCF were analysed by Enzyme immunoassay (EIA). During the experiments, subjective stimulus-evoked pain responses were determined by a visual analogue pain scale. Unilateral stimulation of alveolar mucosa and attached gingiva by capsaicin evoked a distinct neurogenic vasodilatation in the ipsilateral gingiva, which attenuated rapidly at the midline. Capsaicin stimulation of alveolar mucosa provoked clear inflammatory reactions. In contrast to capsaicin stimuli, tooth stimulation produced symmetrical vasodilatations bilaterally in the gingiva. The ipsilateral responses were significantly smaller during tooth stimulation than during capsaicin stimuli. The current finding – that tooth stimulation evokes bilateral vasodilatation while capsaicin stimulation of the gingiva mainly produces unilateral vasodilatation – emphasises the usefulness of LDI in clarifying spatial features of neurogenic vasoactive changes in the intra-oral tissues. Capsaicin stimulation of the alveolar mucosa induced significant elevations in MMP-8 levels and activation in GCF of the adjacent teeth. During the experiments, no marked changes occurred in MMP-8 levels in the GCF of distantly located teeth. Painful stimulation of the upper incisor provoked elevations in GCF MMP-8 and SP levels of the stimulated tooth. The GCF MMP-8 and SP levels of the non-stimulated teeth were not changed. These results suggest that capsaicin-induced inflammatory reactions in gingivomucosal tissues do not cross the midline in the anterior maxilla. The enhanced reaction found during stimulation of alveolar mucosa indicates that alveolar mucosa is more sensitive to chemical irritants than the attached gingiva. Analysis of these data suggests that capsaicin-evoked neurogenic inflammation in the gingiva can trigger the expression and activation of MMP-8 in GCF of the adjacent teeth. In this study, it is concluded that experimental tooth pain at C-fibre intensity can induce local elevations in MMP-8 and SP levels in GCF. Depending on the role of MMP-8 in inflammation, in addition to surrogated tissue destruction, the elevated MMP-8 in GCF may also reflect accelerated local defensive and anti-inflammatory reactions.
Resumo:
The aim of this work is to study flow properties at T-junction of pipe, pressure loss suffered by the flow after passing through T-junction and to study reliability of the classical engineering formulas used to find head loss for T-junction of pipes. In this we have compared our results with CFD software packages with classical formula and made an attempt to determine accuracy of the classical formulas. In this work we have studies head loss in T-junction of pipes with various inlet velocities, head loss in T-junction of pipes when the angle of the junction is slightly different from 90 degrees and T-junction with different area of cross-section of the main pipe and branch pipe. In this work we have simulated the flow at T-junction of pipe with FLUENT and Comsol Multiphysics and observed flow properties inside the T-junction and studied the head loss suffered by fluid flow after passing through the junction. We have also compared pressure (head) losses obtained by classical formulas by A. Vazsonyi and Andrew Gardel and formulas obtained by assuming T-junction as combination of other pipe components and observations obtained from software experiments. One of the purposes of this study is also to study change in pressure loss with change in angle of T-junction. Using software we can have better view of flow inside the junction and study turbulence, kinetic energy, pressure loss etc. Such simulations save a lot of time and can be performed without actually doing the experiment. There were no real life experiments made, the results obtained completely rely on accuracy of software and numerical methods used.