18 resultados para Cervical length measurement

em Doria (National Library of Finland DSpace Services) - National Library of Finland, Finland


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present thesis comprises two study populations. The first study sample (SS1) consisted of 411 adults examined and interviewed at three annual visits. The second study sample (SS2) consisted of 1720 adults who filled in a mailed questionnaire about secondary otalgia, tinnitus and fullness of ears. In the second phase of the SS2, 100 subjects with otalgia were examined and interviewed by specialist in stomatognathic physiology and otorhinolaryngology. In the third phase, 36 subjects participated in a randomized, controlled and blinded trial of effectiveness of occlusal appliance on secondary otalgia, facial pain, headache and treatment need of temporomandibular disorders (TMD). The standardized prevalence of recurrent secondary otalgia was 6%, tinnitus 15% and fullness of ears 8%. Aural symptoms were more frequent among young than old subjects. They were associated with other, simultaneous aural symptoms, TMD pain, head and neck region pain, and visits to a physician. The subjects with aural symptoms more often had tenderness on palpation of masticatory muscles and clinical signs of temporomandibular joint than the subjects without. 85% of the subjects reporting secondary otalgia had cervical spine or temporomandibular disorder or both. In SS1, the final model of secondary otalgia included active need treatment for TMD, elevated level of stress symptoms, and bruxism. In SS2, the final models of aural symptoms included associated aural symptoms, young age, TMD pain, headache and shoulder ache. Stabilization splint more effectively alleviated secondary otalgia and active treatment need for TMD than a palatal control splint. In patients with aural pain, tinnitus or fullness of ears, it is important to first rule out otologic and nasopharyngeal diseases that may cause the symptoms. If no explanation for aural symptoms is found, temporomandibular and cervical spine disorders should be rouled out to minimize unnecessary visits to a physician.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this bachelor's thesis a relay card for capacitance measurements was designed, built and tested. The study was made for the research and development laboratory of VTI Technologies, which manufactures capacitive silicon micro electro mechanical accelerometers and pressure sensors. As the size of the sensors is decreasing the capacitance value of the sensors also decreases. The decreased capacitance causes a need for new and more accurate measurement systems. The technology used in the instrument measuring the capacitance dictates a framework how the relay card should be designed, thus the operating principle of the instrument must be known. To achieve accurate results the measurement instrument and its functions needed to be used correctly. The relay card was designed using printed circuit board design methods that minimize interference coupling to the measurement. The relay card that was designed in this study is modular. It consists of a separate CPU card, which was used to control the add-on cards connected to it. The CPU card was controlled from a computer through a serial bus. Two add-on cards for the CPU card were designed in this study. The first one was the measurement card, which could be used to measure 32 capacitive sensors. The second add-on card was the MUX card, which could be used to switch between two measurement cards. The capacitance measurements carried out through the MUX card and the measurement cards were characterized with a series of test measurements. The test measurement data was then analysed. The relay card design was confirmed to work and offer accurate measurement results up to a measurement frequency of 10 MHz. The length of the measurement cables limited the measurement frequency.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Multiple sclerosis (MS) is a demyelinating disease of the central nervous system, which mainly affects young adults. In Finland, approximately 2500 out of 6000 MS patients have relapsing MS and are treated with disease modifying drugs (DMD): interferon- β (INF-β-1a or INF-β-1b) and glatiramer acetate (GA). Depending on the used IFN-β preparation, 2 % to 40 % of patients develop neutralizing antibodies (NAbs), which abolish the biological effects of IFN-β, leading to reduced clinical and MRI detected efficacy. According to the Finnish Current Care Guidelines and European Federation of Neurological Societis (EFNS) guidelines, it is suggested tomeasure the presence of NAbs during the first 24 months of IFN-β therapy. Aims The aim of this thesis was to measure the bioactivity of IFN-β therapy by focusing on the induction of MxA protein (myxovirus resistance protein A) and its correlation to neutralizing antibodies (NAb). A new MxA EIA assay was set up to offer an easier and rapid method for MxA protein detection in clinical practice. In addition, the tolerability and safety of GA were evaluated in patients who haddiscontinued IFN-β therapy due to side effects and lack of efficacy. Results NAbs developed towards the end of 12 months of treatment, and binding antibodies were detectable before or parallel with them. The titer of NAb correlated negatively with the amount of MxA protein and the mean values of preinjection MxA levels never returned to true baseline in NAb negative patients, but tended to drop in the NAb positive group. The test results between MxA EIA and flow cytometric analysis showed significant correlation. GA reduced the relapse rate and was a safe and well-tolerated therapy in IFN-β-intolerant MS patients. Conclusions NAbs inhibit the induction of MxA protein, which can be used as a surrogate marker of the bioactivity of IFN-β therapy. Compared to flow cytometricanalysis and NAb assay, MxA-EIA seemed to be a sensitive and more practical method in clinical use to measure the actual bioactivity of IFN-β treatment, which is of value also from a cost-effective perspective.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work is devoted to the problem of reconstructing the basis weight structure at paper web with black{box techniques. The data that is analyzed comes from a real paper machine and is collected by an o®-line scanner. The principal mathematical tool used in this work is Autoregressive Moving Average (ARMA) modelling. When coupled with the Discrete Fourier Transform (DFT), it gives a very flexible and interesting tool for analyzing properties of the paper web. Both ARMA and DFT are independently used to represent the given signal in a simplified version of our algorithm, but the final goal is to combine the two together. Ljung-Box Q-statistic lack-of-fit test combined with the Root Mean Squared Error coefficient gives a tool to separate significant signals from noise.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work had two primary objectives: 1) to produce a working prototype for automated printability assessment and 2) to perform a study of available machine vision and other necessary hardware solutions. The three printability testing methods, IGT Picking,He¬liotest, and mottling, considered in this work have several different requirements and the task was to produce a single automated testing system suitable for all methods. A system was designed and built and its performance was tested using the Heliotest. Working proto¬types are important tools for implementing theoretical methods into practical systems and testing and demonstrating the methodsin real life conditions. The system was found to be sufficient for the Heliotest method. Further testing and possible modifications related to other two test methods were left for future works. A short study of available systems and solutions concerning image acquisition of machine vision was performed. The theoretical part of this study includes lighting systems, optical systems and image acquisition tools, mainly cameras and the underlying physical aspects for each portion.