22 resultados para CONTINUOUS VARIABLE SYSTEMS

em Doria (National Library of Finland DSpace Services) - National Library of Finland, Finland


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The present manuscript represents the completion of a research path carried forward during my doctoral studies in the University of Turku. It contains information regarding my scientific contribution to the field of open quantum systems, accomplished in collaboration with other scientists. The main subject investigated in the thesis is the non-Markovian dynamics of open quantum systems with focus on continuous variable quantum channels, e.g. quantum Brownian motion models. Non-Markovianity is here interpreted as a manifestation of the existence of a flow of information exchanged by the system and environment during the dynamical evolution. While in Markovian systems the flow is unidirectional, i.e. from the system to the environment, in non-Markovian systems there are time windows in which the flow is reversed and the quantum state of the system may regain coherence and correlations previously lost. Signatures of a non-Markovian behavior have been studied in connection with the dynamics of quantum correlations like entanglement or quantum discord. Moreover, in the attempt to recognisee non-Markovianity as a resource for quantum technologies, it is proposed, for the first time, to consider its effects in practical quantum key distribution protocols. It has been proven that security of coherent state protocols can be enhanced using non-Markovian properties of the transmission channels. The thesis is divided in two parts: in the first part I introduce the reader to the world of continuous variable open quantum systems and non-Markovian dynamics. The second part instead consists of a collection of five publications inherent to the topic.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A comparison between two competing models of an all mechanical power transmission system is studied by using Dymola –software as the simulation tool. This tool is compared with Matlab/ Simulink –software by using functionality, user-friendliness and price as comparison criteria. In this research we assume that the torque is balanceable and transmission ratios are calculated. Using kinematic connection sketches of the two transmission models, simulation models are built into the Dymola simulation environment. Models of transmission systems are modified according to simulation results to achieve a continuous variable transmission ratio. Simulation results are compared between the two transmission systems. The main features of Dymola and MATLAB/ Simulink are compared. Advantages and disadvantages of the two softwares are analyzed and compared.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Surgery is the cornerstone of ovarian cancer treatment and maximal cytoreduction is important. In the early 1980’s primary surgical treatment of ovarian cancer was performed in over 80 hospitals in Finland. The significance of the operative volume of the hospital, of the training of the surgeons and of centralization of surgical treatment has been widely discussed. The aim of the present study was to evaluate the outcome of surgical treatment of ovarian cancer in different hospital categories retrospectively and prospectively, and to analyze if any differences are reflected in survival. The retrospective study included 3851 ovarian cancer patients operated between 1983 and 1994 in Finland. The data was analyzed according to hospital category (university, central, and other) and by quartiles of the hospital operative volume. The results showed that patients operated in the highest operative volume hospitals had the best relative survival. When stratifying the analysis by the period of diagnosis (1983-1988 and 1989-1994), the university hospitals improved their performance the most. The prospective part of the thesis was initiated in 1999 and included 307 patients with invasive ovarian cancer and 65 patients with an ovarian borderline tumor. The baseline and 5-year surveys used a questionnaire that was filled in by the operating surgeons. For analysis of the 5-year followup data, the hospitals were divided into three categories (<10, 10-20, or >20 patients operated in 1999). The effect of the surgical volume was analyzed also as a continuous variable (1-47 operations per year). In university hospitals, pelvic lymphadenectomy was performed in 88 %, and para-aortic lymphadenectomy in 73 %, of the patients with stage I disease. The corresponding figures ranged from 11 % to 21 % in the other hospitals. For stage III ovarian cancer patients operated by gynecological oncologists, the estimated odds ratio for no macroscopic residual tumor was 3.0 times higher (95 % CI 1.2-7.5) than for those operated by general gynecologists. In the university and other hospitals 82% of the patients received platinum-based chemotherapy. Platinum + taxane combination was given to 63 % of the patients in the university and in 49 % in the other hospitals (p = 0.0763). Only a minority of the patients with tumors of borderline malignancy were staged according to recommendations, most often multiple peritoneal biopsies and omentectomy were neglected. FIGO stage, patient age, and residual tumor were independent prognostic factors of cancer-specific 5-year survival. A higher hospital operative volume was also a significant prognostic factor for better cancer-specific survival (p = 0.036) and disease-free survival (p = 0.048). In conclusion, ovarian cancer patients operated in high-volume university hospitals were more often optimally debulked and had a significantly better cancer-specific survival than patients operated in other hospitals. These results favor centralization of primary surgical treatment of ovarian cancer.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

EU:n polttodirektiivit, LCP- ja jätteenpolttodirektiivi ovat arkipäivää suuressa osassa polttolaitoksia Suomessakin lähivuosien kuluessa. Molemmat direktiivit on otettu mukaan Suomen lain-säädäntöön asetuksina, joita on hieman muutettu vastaamaan kansallisia tarpeita. Polttolaitokset tulevat muuttamaan aikaisempia käytäntöjään päästöistä mitattavien komponenttien sekä tarkkailujaksojen että raportoinnin osalta. Mittausten tulokset raportoidaan jatkossa yksikössä mg/Nm3. Jatkuvatoimisia mittausjärjestelmiä on asennettava yhä useampaan laitokseen ja savukaasuista tarkkaillaan pitoisuuksia päästöjen sijaan. Edelleen raportoidaan esim. ympäristölupaviranomaiselle vuosipäästöjen suuruus. Vuonna 2000 voimaan tulleen ympäristönsuojelulain ja -asetuksen velvoittamina toiminnassa olevat sellutehtaat ovat hakeneet uuden lain mukaista ympäristölupaa vuoden 2004 loppuun mennessä. Ympäristöluvan tarvitsevat myös kaikki teholtaan yli 50 MW:n polttolaitokset. Suuria polttolaitoksia koskeva LCP-direktiivi astuu voimaan vuoden 2008 alussa. Siksi uusissa ympäristöluvissa tullaantodennäköisesti vaatimaan myös sellutehtailta ko. direktiivin mukaisia mittaus-järjestelmiä ja päästörajoja. Laitoksissa on jo nyt melko kattavat päästömittausjärjestelmät, sillä myös voimassaolevat ympäristöluvat ja ilmapäästöjen tarkkailuohjelmat velvoittavat päästöjen jatkuvaan seurantaan pääosin samoista savukaasukomponenteista kuin mitä direktiivissäkin edellytetään. Tässä diplomityössä keskitytään LCP- ja jätteenpolttodirektiivien mittausvaatimuksiin, raja-arvoihin sekä raportointiin sekä Metsä-Botnian sellutehtaiden mittausjärjestelmien parantamis-toimenpiteisiin. Yksityiskohtainen toimintamalli on tehty Joutsenon tehtaan laitosta ja mittaus-järjestelmää silmällä pitäen. Sitä voidaan käyttää myös muillatehtailla mallina savukaasupäästöjen mittauksien ja laitteiden päivitysten yhteydessä. Toimintamalliin siirtyminen ei velvoita Metsä-Botnian tehtaita, mutta monet tehtaat haluavat laitteistokannan uusimisen yhteydessä siirtyä direktiivien vaatimuksia vastaavaan järjestelmään.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Prosessiteollisuudessa syntyviä ilmapäästöjä seurataan jatkuvatoimisilla mittausjärjestelmillä. Jatkuvatoimisen päästöjen seurantajärjestelmän tulee tuottaa luotettavaa tietoa prosessin aiheuttamista päästöistä. Päästöjen seurannasta saataviin tuloksiin syntyy aina epävarmuutta, joka koostuu mittausolosuhteiden, mittausjärjestelmän tai mittauksen suorittamisen aiheuttamista epävarmuuksista. Työn alussa on kuvattu Stora Enso Oyj:n Imatran tehtaitten typen oksidien jatkuvatoiminen päästöjen seurantamenetelmä ja selvitetty seurantajärjestelmän suorittama päästöjen laskentamenetelmä. Lisäksi on tuotu esille päästömittaustuloksen epävarmuuteen vaikuttavia tekijöitä kyseisessä järjestelmässä. Selvityksessä merkittävimmäksi järjestelmän luotettavuuteen vaikuttavaksi tekijäksi osoittautui virheellinen mittaustieto, jota voidaan hallita järjestelmässä asettamalla raja-arvo mittaustiedolle ja tehostamalla käytönaikaista valvontaa. Lisäksi korvaamalla häiriöaikainen virheellinen mittaustieto laskennallisella pitoisuuden odotusarvolla päästölaskentaa varten, tuottaa seurantajärjestelmä luotettavampia typen oksidien päästötietoja raportointia varten.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This thesis presents briefly the basic operation and use of centrifugal pumps and parallel pumping applications. The characteristics of parallel pumping applications are compared to circuitry, in order to search analogy between these technical fields. The purpose of studying circuitry is to find out if common software tools for solving circuit performance could be used to observe parallel pumping applications. The empirical part of the thesis introduces a simulation environment for parallel pumping systems, which is based on circuit components of Matlab Simulink —software. The created simulation environment ensures the observation of variable speed controlled parallel pumping systems in case of different controlling methods. The introduced simulation environment was evaluated by building a simulation model for actual parallel pumping system at Lappeenranta University of Technology. The simulated performance of the parallel pumps was compared to measured values of the actual system. The gathered information shows, that if the initial data of the system and pump perfonnance is adequate, the circuitry based simulation environment can be exploited to observe parallel pumping systems. The introduced simulation environment can represent the actual operation of parallel pumps in reasonably accuracy. There by the circuitry based simulation can be used as a researching tool to develop new controlling ways for parallel pumps.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The aim of this master´s thesis is to study which processes increase the auxiliary power consumption in carbon capture and storage processes and if it is possible to reduce the auxiliary power consumption with variable speed drives. Also the cost of carbon capture and storage is studied. Data about auxiliary power consumption in carbon capture is gathered from various studies and estimates made by various research centres. Based on these studies a view is presented how the power auxiliary power consumption is divided between different processes in carbon capture processes. In a literary study, the operation of three basic carbon capture systems is described. Also different methods to transport carbon dioxide and carbon dioxide storage options are described in this section. At the end of the thesis processes that consume most of the auxiliary power are defined and possibilities to reduce the auxiliary power consumption are evaluated. Cost of carbon capture, transport and storage are also evaluated at this point and in the case that the carbon capture and storage systems are fully deployed. According to the results, it can be estimated what are the processes are where variable speed drives can be used and what kind of cost and power consumption reduction could be achieved. Results also show how large a project carbon capture and storage is if it is fully deployed.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This dissertation describes a networking approach to infinite-dimensional systems theory, where there is a minimal distinction between inputs and outputs. We introduce and study two closely related classes of systems, namely the state/signal systems and the port-Hamiltonian systems, and describe how they relate to each other. Some basic theory for these two classes of systems and the interconnections of such systems is provided. The main emphasis lies on passive and conservative systems, and the theoretical concepts are illustrated using the example of a lossless transfer line. Much remains to be done in this field and we point to some directions for future studies as well.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The pumping processes requiring wide range of flow are often equipped with parallelconnected centrifugal pumps. In parallel pumping systems, the use of variable speed control allows that the required output for the process can be delivered with a varying number of operated pump units and selected rotational speed references. However, the optimization of the parallel-connected rotational speed controlled pump units often requires adaptive modelling of both parallel pump characteristics and the surrounding system in varying operation conditions. The available information required for the system modelling in typical parallel pumping applications such as waste water treatment and various cooling and water delivery pumping tasks can be limited, and the lack of real-time operation point monitoring often sets limits for accurate energy efficiency optimization. Hence, alternatives for easily implementable control strategies which can be adopted with minimum system data are necessary. This doctoral thesis concentrates on the methods that allow the energy efficient use of variable speed controlled parallel pumps in system scenarios in which the parallel pump units consist of a centrifugal pump, an electric motor, and a frequency converter. Firstly, the suitable operation conditions for variable speed controlled parallel pumps are studied. Secondly, methods for determining the output of each parallel pump unit using characteristic curve-based operation point estimation with frequency converter are discussed. Thirdly, the implementation of the control strategy based on real-time pump operation point estimation and sub-optimization of each parallel pump unit is studied. The findings of the thesis support the idea that the energy efficiency of the pumping can be increased without the installation of new, more efficient components in the systems by simply adopting suitable control strategies. An easily implementable and adaptive control strategy for variable speed controlled parallel pumping systems can be created by utilizing the pump operation point estimation available in modern frequency converters. Hence, additional real-time flow metering, start-up measurements, and detailed system model are unnecessary, and the pumping task can be fulfilled by determining a speed reference for each parallel-pump unit which suggests the energy efficient operation of the pumping system.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fluid handling systems account for a significant share of the global consumption of electrical energy. They also suffer from problems, which reduce their energy efficiency and increase life-cycle costs. Detecting or predicting these problems in time can make fluid handling systems more environmentally and economically sustainable to operate. In this Master’s Thesis, significant problems in fluid systems were studied and possibilities to develop variable-speed-drive-based detection methods for them was discussed. A literature review was conducted to find significant problems occurring in fluid handling systems containing pumps, fans and compressors. To find case examples for evaluating the feasibility of variable-speed-drive-based methods, queries were sent to industrial companies. As a result of this, the possibility to detect heat exchanger fouling with a variable-speed drive was analysed with data from three industrial cases. It was found that a mass flow rate estimate, which can be generated with a variable speed drive, can be used together with temperature measurements to monitor a heat exchanger’s thermal performance. Secondly, it was found that the fouling-related increase in the pressure drop of a heat exchanger can be monitored with a variable speed drive. Lastly, for systems where the flow device is speed controlled with by a pressure measurement, it was concluded that increasing rotational speed can be interpreted as progressing fouling in the heat exchanger.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

As the world’s energy demand is increasing, a durable solution to control it is to improve the energy efficiency of the processes. It has been estimated that pumping applications have a significant potential for energy savings trough equipment or control system changes. For many pumping application the use of a variable speed drive as a process control element is the most energy efficient solution. The main target of this study is to examine the energy efficiency of a drive system that moves the pump. In a larger scale the purpose of this study is to examine how the different manufacturers’ variable speed drives are functioning as a control device of a pumping process. The idea is to compare the drives from a normal pump user’s point of view. The things that are mattering for the pump user are the efficiency gained in the process and the easiness of the use of the VSD. So some thought is given also on valuating the user-friendliness of the VSDs. The VSDs are compared to each other also on the basis of their life cycle energy costs in different kind of pumping cases. The comparison is made between ACS800 from ABB, VLT AQUA Drive from Danfoss, NX-drive from Vacon and Micromaster 430 from Siemens. The efficiencies are measured in power electronics laboratory in the Lappeenranta University of Technology with a system that consists of a variable speed drive, an induction motor with dc-machine, two power analyzers and a torque transducer. The efficiencies are measured as a function of a load at different frequencies. According to measurement results the differences between the measured system efficiencies on the actual working area of pumping are on average few percent units. When examining efficiencies at the whole range of different loads and frequencies, the differences get bigger. At low frequencies and loads the differences between the most efficient and the least efficient systems are at the most about ten percent units. At the most of the tested points ABB’s drive seem to have slightly better efficiencies than the other drives.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Energy consumption and energy efficiency have become an issue. Energy consumption is rising all over the world and because of that, and the climate change, energy is becoming more and more expensive. Buildings are major consumers of energy, and inside the buildings the major consumers are heating, ventilation and air-conditioning systems. They usually run at constant speed without efficient control. In most cases HVAC equipment is also oversized. Traditionally heating, ventilation and air-conditioning systems have been sized to meet conditions that rarely occur. The theory part in this thesis represents the basics of life cycle costs and calculations for the whole life cycle of a system. It also represents HVAC systems, equipment, systems controls and ways to save energy in these systems. The empirical part of this thesis represents life cycle cost calculations for HVAC systems. With these calculations it is possible to compute costs for the whole life cycle for the wanted variables. Life cycle costs make it possible to compare which variable causes most of the costs from the whole life point of view. Life cycle costs were studied through two real life cases which were focused on two different kinds of HVAC systems. In both of these cases the renovations were already made, so that the comparison between the old and the new, now existing system would be easier. The study indicates that energy can be saved in HVAC systems by using variable speed drive as a control method.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The RPC Detector Control System (RCS) is the main subject of this PhD work. The project, involving the Lappeenranta University of Technology, the Warsaw University and INFN of Naples, is aimed to integrate the different subsystems for the RPC detector and its trigger chain in order to develop a common framework to control and monitoring the different parts. In this project, I have been strongly involved during the last three years on the hardware and software development, construction and commissioning as main responsible and coordinator. The CMS Resistive Plate Chambers (RPC) system consists of 912 double-gap chambers at its start-up in middle of 2008. A continuous control and monitoring of the detector, the trigger and all the ancillary sub-systems (high voltages, low voltages, environmental, gas, and cooling), is required to achieve the operational stability and reliability of a so large and complex detector and trigger system. Role of the RPC Detector Control System is to monitor the detector conditions and performance, control and monitor all subsystems related to RPC and their electronics and store all the information in a dedicated database, called Condition DB. Therefore the RPC DCS system has to assure the safe and correct operation of the sub-detectors during all CMS life time (more than 10 year), detect abnormal and harmful situations and take protective and automatic actions to minimize consequential damages. The analysis of the requirements and project challenges, the architecture design and its development as well as the calibration and commissioning phases represent themain tasks of the work developed for this PhD thesis. Different technologies, middleware and solutions has been studied and adopted in the design and development of the different components and a big challenging consisted in the integration of these different parts each other and in the general CMS control system and data acquisition framework. Therefore, the RCS installation and commissioning phase as well as its performance and the first results, obtained during the last three years CMS cosmic runs, will be

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Besides the sustaining of healthy and comfortable indoor climate, the air conditioning system should also achieve for energy efficiency. The target indoor climate can be ob-tained with different systems; this study focuses on comparing the energy efficiency of different air conditioning room unit systems in different climates. The calculations are made with dynamic energy simulation software IDA ICE by comparing the indoor cli-mate and energy consumption of an office building with different systems in different climates. The aim of the study is to compare the energy efficiency of chilled beam systems to other common systems: variable air volume, fan coil and radiant ceiling systems. Besides the annual energy consumption also the sustainability of target indoor climate is compared between the simulations. Another aim is to provide conclusions to be used in the product development of the chilled beam systems’ energy efficiency. The adaptable chilled beam system and the radiant ceiling system prove to be energy efficient independent of the climate. The challenge of reliable comparison is that other systems are not able to reach the target indoor climate as well as the others. The complex calculation environment of the simulation software, made assumptions and excluding of the financial aspects complicate comparing the big picture. The results show that the development of the chilled beam systems should concentrate on energy efficient night heating, flexible demand based ventilation and capacity control and possibilities on integrating the best practices with other systems. 

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fan systems are responsible for approximately 10% of the electricity consumption in industrial and municipal sectors, and it has been found that there is energy-saving potential in these systems. To this end, variable speed drives (VSDs) are used to enhance the efficiency of fan systems. Usually, fan system operation is optimized based on measurements of the system, but there are seldom readily installed meters in the system that can be used for the purpose. Thus, sensorless methods are needed for the optimization of fan system operation. In this thesis, methods for the fan operating point estimation with a variable speed drive are studied and discussed. These methods can be used for the energy efficient control of the fan system without additional measurements. The operation of these methods is validated by laboratory measurements and data from an industrial fan system. In addition to their energy consumption, condition monitoring of fan systems is a key issue as fans are an integral part of various production processes. Fan system condition monitoring is usually carried out with vibration measurements, which again increase the system complexity. However, variable speed drives can already be used for pumping system condition monitoring. Therefore, it would add to the usability of a variablespeed- driven fan system if the variable speed drive could be used as a condition monitoring device. In this thesis, sensorless detection methods for three lifetime-reducing phenomena are suggested: these are detection of the fan contamination build-up, the correct rotational direction, and the fan surge. The methods use the variable speed drive monitoring and control options for the detection along with simple signal processing methods, such as power spectrum density estimates. The methods have been validated by laboratory measurements. The key finding of this doctoral thesis is that a variable speed drive can be used on its own as a monitoring and control device for the fan system energy efficiency, and it can also be used in the detection of certain lifetime-reducing phenomena.