135 resultados para Available transfer capability (ATC)

em Doria (National Library of Finland DSpace Services) - National Library of Finland, Finland


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The study of fluid flow in pipes is one of the main topic of interest for engineers in industries. In this thesis, an effort is made to study the boundary layers formed near the wall of the pipe and how it behaves as a resistance to heat transfer. Before few decades, the scientists used to derive the analytical and empirical results by hand as there were limited means available to solve the complex fluid flow phenomena. Due to the increase in technology, now it has been practically possible to understand and analyze the actual fluid flow in any type of geometry. Several methodologies have been used in the past to analyze the boundary layer equations and to derive the expression for heat transfer. An integral relation approach is used for the analytical solution of the boundary layer equations and is compared with the FLUENT simulations for the laminar case. Law of the wall approach is used to derive the empirical correlation between dimensionless numbers and is then compared with the results from FLUENT for the turbulent case. In this thesis, different approaches like analytical, empirical and numerical are compared for the same set of fluid flow equations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Uusi EPR-reaktorikonsepti on suunniteltu selviytymään tapauksista, joissa reaktorinsydän sulaa ja sula puhkaisee paineastian. Suojarakennuksen sisälle on suunniteltu alue, jolle sula passiivisesti kerätään, pidätetään ja jäähdytetään. Alueelle laaditaan valurautaelementeistä ns.sydänsieppari, joka tulvitetaan vedellä. Sydänsulan tuottama jälkilämpö siirtyyveteen, mistä se poistetaan suojarakennuksen jälkilämmönpoistojärjestelmän kautta. Suuri osa lämmöstä poistuu sydänsulasta sen yläpuolella olevaan veteen, mutta lämmönsiirron tehostamiseksi myös sydänsiepparin alapuolelle on sijoitettu vedellä täytettävät jäähdytyskanavat. Jotta sydänsiepparin toiminta voitaisiin todentaa, on Lappeenrannan Teknillisellä Yliopistolla rakennettu Volley-koelaitteisto tätä tarkoitusta varten. Koelaitteisto koostuu kahdesta täysimittaisesta valuraudasta tehdystä jäähdytyskanavasta. Sydänsulan tuottamaa jälkilämpöä simuloidaan koelaitteistossa sähkövastuksilla. Tässä työssä kuvataan simulaatioiden suorittaminen ja vertaillaan saatuja arvoja mittaustuloksiin. Työ keskittyy sydänsiepparista jäähdytyskanaviin tapahtuvan lämmönsiirron teoriaan jamekanismeihin. Työssä esitetään kolme erilaista korrelaatiota lämmönsiirtokertoimille allaskiehumisen tapauksessa. Nämä korrelaatiot soveltuvat erityisesti tapauksiin, joissa vain muutamia mittausparametreja on tiedossa. Työn toinen osa onVolley 04 -kokeiden simulointi. Ensin käytettyä simulointitapaa on kelpoistettuvertaamalla tuloksia Volley 04 ja 05 -kokeisiin, joissa koetta voitiin jatkaa tasapainotilaan ja joissa jäähdytteen käyttäytyminen jäähdytyskanavassa on tallennettu myös videokameralla. Näiden simulaatioiden tulokset ovat hyvin samanlaisiakuin mittaustulokset. Korkeammilla lämmitystehoilla kokeissa esiintyi vesi-iskuja, jotka rikkoivat videoinnin mahdollistavia ikkunoita. Tämän johdosta osassa Volley 04 -kokeita ikkunat peitettiin metallilevyillä. Joitakin kokeita jouduttiin keskeyttämään laitteiston suurten lämpöjännitysten johdosta. Tällaisten testien simulaatiot eivät ole yksinkertaisia suorittaa. Veden pinnan korkeudesta ei ole visuaalista havaintoa. Myöskään jäähdytteen tasapainotilanlämpötiloista ei ole tarkkaa tietoa, mutta joitakin oletuksia voidaan tehdä samoilla parametreilla tehtyjen Volley 05 -kokeiden perusteella. Mittaustulokset Volley 04 ja 05 -kokeista, jotka on videoitu ja voitu ajaa tasapainotilaan saakka, antoivat simulaatioiden kanssa hyvin samankaltaisia lämpötilojen arvoja. Keskeytettyjen kokeiden ekstrapolointi tasapainotilaan ei onnistunut kovin hyvin. Kokeet jouduttiin keskeyttämään niin paljon ennen termohydraulista tasapainoa, ettei tasapainotilan reunaehtoja voitu ennustaa. Videonauhoituksen puuttuessa ei veden pinnan korkeudesta saatu lisätietoa. Tuloksista voidaan lähinnä esittää arvioita siitä, mitä suuruusluokkaa mittapisteiden lämpötilat tulevat olemaan. Nämä lämpötilat ovat kuitenkin selvästi alle sydänsiepparissa käytettävän valuraudan sulamislämpötilan. Joten simulaatioiden perusteella voidaan sanoa, etteivät jäähdytyskanavien rakenteet sula, mikäli niissä on pienikin jäähdytevirtaus, eikä useampia kuin muutama vierekkäinen kanava ole täysin kuivana.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Gas-liquid mass transfer is an important issue in the design and operation of many chemical unit operations. Despite its importance, the evaluation of gas-liquid mass transfer is not straightforward due to the complex nature of the phenomena involved. In this thesis gas-liquid mass transfer was evaluated in three different gas-liquid reactors in a traditional way by measuring the volumetric mass transfer coefficient (kLa). The studied reactors were a bubble column with a T-junction two-phase nozzle for gas dispersion, an industrial scale bubble column reactor for the oxidation of tetrahydroanthrahydroquinone and a concurrent downflow structured bed.The main drawback of this approach is that the obtained correlations give only the average volumetric mass transfer coefficient, which is dependent on average conditions. Moreover, the obtained correlations are valid only for the studied geometry and for the chemical system used in the measurements. In principle, a more fundamental approach is to estimate the interfacial area available for mass transfer from bubble size distributions obtained by solution of population balance equations. This approach has been used in this thesis by developing a population balance model for a bubble column together with phenomenological models for bubble breakage and coalescence. The parameters of the bubble breakage rate and coalescence rate models were estimated by comparing the measured and calculated bubble sizes. The coalescence models always have at least one experimental parameter. This is because the bubble coalescence depends on liquid composition in a way which is difficult to evaluate using known physical properties. The coalescence properties of some model solutions were evaluated by measuring the time that a bubble rests at the free liquid-gas interface before coalescing (the so-calledpersistence time or rest time). The measured persistence times range from 10 msup to 15 s depending on the solution. The coalescence was never found to be instantaneous. The bubble oscillates up and down at the interface at least a coupleof times before coalescence takes place. The measured persistence times were compared to coalescence times obtained by parameter fitting using measured bubble size distributions in a bubble column and a bubble column population balance model. For short persistence times, the persistence and coalescence times are in good agreement. For longer persistence times, however, the persistence times are at least an order of magnitude longer than the corresponding coalescence times from parameter fitting. This discrepancy may be attributed to the uncertainties concerning the estimation of energy dissipation rates, collision rates and mechanisms and contact times of the bubbles.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This thesis gathers knowledge about ongoing high-temperature reactor projects around the world. Methods for calculating coolant flow and heat transfer inside a pebble-bed reactor core are also developed. The thesis begins with the introduction of high-temperature reactors including the current state of the technology. Process heat applications that could use the heat from a high-temperature reactor are also introduced. A suitable reactor design with data available in literature is selected for the calculation part of the thesis. Commercial computational fluid dynamics software Fluent is used for the calculations. The pebble-bed is approximated as a packed-bed, which causes sink terms to the momentum equations of the gas flowing through it. A position dependent value is used for the packing fraction. Two different models are used to calculate heat transfer. First a local thermal equilibrium is assumed between the gas and solid phases and a single energy equation is used. In the second approach, separate energy equations are used for the phases. Information about steady state flow behavior, pressure loss, and temperature distribution in the core is obtained as results of the calculations. The effect of inlet mass flow rate to pressure loss is also investigated. Data found in literature and the results correspond each other quite well, considered the amount of simplifications in the calculations. The models developed in this thesis can be used to solve coolant flow and heat transfer in a pebble-bed reactor, although additional development and model validation is needed for better accuracy and reliability.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of the present study was to demonstrate the wide applicability of the novel photoluminescent labels called upconverting phosphors (UCPs) in proximity-based bioanalytical assays. The exceptional features of the lanthanide-doped inorganic UCP compounds stem from their capability for photon upconversion resulting in anti-Stokes photoluminescence at visible wavelengths under near-infrared (NIR) excitation. Major limitations related to conventional photoluminescent labels are avoided, rendering the UCPs a competitive next-generation label technology. First, the background luminescence is minimized due to total elimination of autofluorescence. Consequently, improvements in detectability are expected. Second, at the long wavelengths (>600 nm) used for exciting and detecting the UCPs, the transmittance of sample matrixes is significantly greater in comparison with shorter wavelengths. Colored samples are no longer an obstacle to the luminescence measurement, and more flexibility is allowed even in homogeneous assay concepts, where the sample matrix remains present during the entire analysis procedure, including label detection. To transform a UCP particle into a biocompatible label suitable for bioanalytical assays, it must be colloidal in an aqueous environment and covered with biomolecules capable of recognizing the analyte molecule. At the beginning of this study, only UCP bulk material was available, and it was necessary to process the material to submicrometer-sized particles prior to use. Later, the ground UCPs, with irregular shape, wide size-distribution and heterogeneous luminescence properties, were substituted by a smaller-sized spherical UCP material. The surface functionalization of the UCPs was realized by producing a thin hydrophilic coating. Polymer adsorption on the UCP surface is a simple way to introduce functional groups for bioconjugation purposes, but possible stability issues encouraged us to optimize an optional silica-encapsulation method which produces a coating that is not detached in storage or assay conditions. An extremely thin monolayer around the UCPs was pursued due to their intended use as short-distance energy donors, and much attention was paid to controlling the thickness of the coating. The performance of the UCP technology was evaluated in three different homogeneous resonance energy transfer-based bioanalytical assays: a competitive ligand binding assay, a hybridization assay for nucleic acid detection and an enzyme activity assay. To complete the list, a competitive immunoassay has been published previously. Our systematic investigation showed that a nonradiative energy transfer mechanism is indeed involved, when a UCP and an acceptor fluorophore are brought into close proximity in aqueous suspension. This process is the basis for the above-mentioned homogeneous assays, in which the distance between the fluorescent species depends on a specific biomolecular binding event. According to the studies, the submicrometer-sized UCP labels allow versatile proximity-based bioanalysis with low detection limits (a low-nanomolar concentration for biotin, 0.01 U for benzonase enzyme, 0.35 nM for target DNA sequence).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of the work presented in this study was to demonstrate the wide applicability of a single-label quenching resonance energy transfer (QRET) assay based on time-resolved lanthanide luminescence. QRET technology is proximity dependent method utilizing weak and unspecific interaction between soluble quencher molecule and lanthanide chelate. The interaction between quencher and chelate is lost when the ligand binds to its target molecule. The properties of QRET technology are especially useful in high throughput screening (HTS) assays. At the beginning of this study, only end-point type QRET technology was available. To enable efficient study of enzymatic reactions, the QRET technology was further developed to enable measurement of reaction kinetics. This was performed using proteindeoxyribonuclei acid (DNA) interaction as a first tool to monitor reaction kinetics. Later, the QRET was used to study nucleotide exchange reaction kinetics and mutation induced effects to the small GTPase activity. Small GTPases act as a molecular switch shifting between active GTP bound and inactive GDP bound conformation. The possibility of monitoring reaction kinetics using the QRET technology was evaluated using two homogeneous assays: a direct growth factor detection assay and a nucleotide exchange monitoring assay with small GTPases. To complete the list, a heterogeneous assay for monitoring GTP hydrolysis using small GTPases, was developed. All these small GTPase assays could be performed using nanomolar protein concentrations without GTPase pretreatment. The results from these studies demonstrated that QRET technology can be used to monitor reaction kinetics and further enable the possibility to use the same method for screening.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study examines how MPEG-2 Transport Stream, used in DVB-T video transmission, can be reliably and efficiently transferred to remote locations over an MPLS network. All the relevant technologies used in this scenario are also discussed in the study. This study was done for Digita Oy, which is a major radio and television content distributor in Finland. The theoretical part of the study begins with the introduction to MPLS technology and continues with explanation of IP Multicast and its components. The fourth section discusses MPEG-2 and the formation and content of MPEG-2 Transport Stream. These technologies were studied in relevant literature and RFC documentation. After the theoretical part of the study, the test setup and the test cases are presented. The results of the test cases, and the conclusions that can be drawn based on them, are discussed in the last section of the study. The tests showed that it is possible to transfer digital video quite reliably over an MPLS network using IP Multicast. By configuring the equipment correctly, the recovery time of the network in case of a failure can be shortened remarkably. Also, the unwanted effect of other traffic on the critical video traffic can be eliminated by defining the Quality of Service parameters correctly. There are, however, some issues that need to be tested further before this setup can be used in broadcast networks. Reliable operation of IP Multicast and proper error correction are the main subjects for future testing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Selostus: Hevosen alkioiden värjääminen DAPI:lla ennen vastaanottajaan siirtoa

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Selostus: Radiocesiumin kulkeutuminen eri laidunekosysteemien maa-ruoho-lammas -ravintoketjussa

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Selostus: Vasikoiden tuottaminen tuoreilla ja kylmäsäilytetyillä halkaistuilla alkioilla

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Selostus: Alkionsiirtojalostusohjelma "ASMO", sen tavoitteet ja yhteenveto alkuvalinnan tuloksista

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Selostus: [sup 134]Cs-aktiivisuuspitoisuuden vähentäminen ferriheksasyanoferraatin avulla

Relevância:

20.00% 20.00%

Publicador: