2 resultados para 0.9 per mil were added

em Doria (National Library of Finland DSpace Services) - National Library of Finland, Finland


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In older populations, fractures are common and the consequences of fractures may be serious both for an individual and for society. However, information is scarce about the incidence, predictors and consequences of fractures in population-based unselected cohorts including both men and women and a long follow-up. The objective of this study was to analyse the incidence and predictors of fractures as well as functional decline and excess mortality due to fractures, among 482 men and 695 women aged 65 or older in the municipality of Lieto, Finland from 1991 until 2002. In analyses, Poisson’s, Cox proportional Hazards and Cumulative Logistic regression models were used for the control of several confounding variables. During the 12-year follow-up with a total of 10 040 person-years (PY), 307 (26%) persons sustained altogether 425 fractures of which 77% were sustained by women. The total incidence of fractures was 53.4 per 1000 PY (95% confidence intervals [95% CI]: 47.9 - 59.5) in women and 24.9 per 1000 PY (95% CI: 20.4 - 30.4) in men. The incidence rates of fractures at any sites and hip fractures were associated with increasing age. No significant changes in the ageadjusted incidence rates of fractures were found in either gender during the 12-year follow-up. The predictors of fractures varied by gender. In multivariate analyses, reduced handgrip strength and body mass index (BMI) lower than 30 in women and a large number of depressive symptoms in men were independent predictors of fractures. A compression fracture in one or more thoracic or upper lumbar vertebras on chest radiography at baseline was associated with subsequent fractures in both genders. Lower body fractures independently predicted both short- (0-2 years) and long-term (up to 8 years) functional decline in mobility and activities of daily living (ADL) performance during the 8-year follow-up. Upper body fractures predicted decline in ADL performance during longterm follow-up. In the 12-year follow-up, hip fractures in men (Hazard Ratio [HR] 8.1, 95% CI: 4.4-14.9) and in women (HR 3.0, 95% CI: 1.9-4.9), and fractures at the proximal humerus in men (HR 5.4, 95% CI: 1.6-17.7) were independently associated with excess mortality. In addition, leisure time inactivity in physical exercise predicted independently both functional decline and excess mortality. Fractures are common among older people posing serious individual consequences. Further studies about the effectiveness of preventing falls and fractures as well as improving care and rehabilitation after fractures are needed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this study, cantilever-enhanced photoacoustic spectroscopy (CEPAS) was applied in different drug detection schemes. The study was divided into two different applications: trace detection of vaporized drugs and drug precursors in the gas-phase, and detection of cocaine abuse in hair. The main focus, however, was the study of hair samples. In the gas-phase, methyl benzoate, a hydrolysis product of cocaine hydrochloride, and benzyl methyl ketone (BMK), a precursor of amphetamine and methamphetamine were investigated. In the solid-phase, hair samples from cocaine overdose patients were measured and compared to a drug-free reference group. As hair consists mostly of long fibrous proteins generally called keratin, proteins from fingernails and saliva were also studied for comparison. Different measurement setups were applied in this study. Gas measurements were carried out using quantum cascade lasers (QLC) as a source in the photoacoustic detection. Also, an external cavity (EC) design was used for a broader tuning range. Detection limits of 3.4 particles per billion (ppb) for methyl benzoate and 26 ppb for BMK in 0.9 s were achieved with the EC-QCL PAS setup. The achieved detection limits are sufficient for realistic drug detection applications. The measurements from drug overdose patients were carried out using Fourier transform infrared (FTIR) PAS. The drug-containing hair samples and drug-free samples were both measured with the FTIR-PAS setup, and the measured spectra were analyzed statistically with principal component analysis (PCA). The two groups were separated by their spectra with PCA and proper spectral pre-processing. To improve the method, ECQCL measurements of the hair samples, and studies using photoacoustic microsampling techniques, were performed. High quality, high-resolution spectra with a broad tuning range were recorded from a single hair fiber. This broad tuning range of an EC-QCL has not previously been used in the photoacoustic spectroscopy of solids. However, no drug detection studies were performed with the EC-QCL solid-phase setup.