56 resultados para setup carryover
Resumo:
Effective control and limiting of carbon dioxide (CO₂) emissions in energy production are major challenges of science today. Current research activities include the development of new low-cost carbon capture technologies, and among the proposed concepts, chemical combustion (CLC) and chemical looping with oxygen uncoupling (CLOU) have attracted significant attention allowing intrinsic separation of pure CO₂ from a hydrocarbon fuel combustion process with a comparatively small energy penalty. Both CLC and CLOU utilize the well-established fluidized bed technology, but several technical challenges need to be overcome in order to commercialize the processes. Therefore, development of proper modelling and simulation tools is essential for the design, optimization, and scale-up of chemical looping-based combustion systems. The main objective of this work was to analyze the technological feasibility of CLC and CLOU processes at different scales using a computational modelling approach. A onedimensional fluidized bed model frame was constructed and applied for simulations of CLC and CLOU systems consisting of interconnected fluidized bed reactors. The model is based on the conservation of mass and energy, and semi-empirical correlations are used to describe the hydrodynamics, chemical reactions, and transfer of heat in the reactors. Another objective was to evaluate the viability of chemical looping-based energy production, and a flow sheet model representing a CLC-integrated steam power plant was developed. The 1D model frame was succesfully validated based on the operation of a 150 kWth laboratory-sized CLC unit fed by methane. By following certain scale-up criteria, a conceptual design for a CLC reactor system at a pre-commercial scale of 100 MWth was created, after which the validated model was used to predict the performance of the system. As a result, further understanding of the parameters affecting the operation of a large-scale CLC process was acquired, which will be useful for the practical design work in the future. The integration of the reactor system and steam turbine cycle for power production was studied resulting in a suggested plant layout including a CLC boiler system, a simple heat recovery setup, and an integrated steam cycle with a three pressure level steam turbine. Possible operational regions of a CLOU reactor system fed by bituminous coal were determined via mass, energy, and exergy balance analysis. Finally, the 1D fluidized bed model was modified suitable for CLOU, and the performance of a hypothetical 500 MWth CLOU fuel reactor was evaluated by extensive case simulations.
Resumo:
Distributed storage systems are studied. The interest in such system has become relatively wide due to the increasing amount of information needed to be stored in data centers or different kinds of cloud systems. There are many kinds of solutions for storing the information into distributed devices regarding the needs of the system designer. This thesis studies the questions of designing such storage systems and also fundamental limits of such systems. Namely, the subjects of interest of this thesis include heterogeneous distributed storage systems, distributed storage systems with the exact repair property, and locally repairable codes. For distributed storage systems with either functional or exact repair, capacity results are proved. In the case of locally repairable codes, the minimum distance is studied. Constructions for exact-repairing codes between minimum bandwidth regeneration (MBR) and minimum storage regeneration (MSR) points are given. These codes exceed the time-sharing line of the extremal points in many cases. Other properties of exact-regenerating codes are also studied. For the heterogeneous setup, the main result is that the capacity of such systems is always smaller than or equal to the capacity of a homogeneous system with symmetric repair with average node size and average repair bandwidth. A randomized construction for a locally repairable code with good minimum distance is given. It is shown that a random linear code of certain natural type has a good minimum distance with high probability. Other properties of locally repairable codes are also studied.
Resumo:
An electric system based on renewable energy faces challenges concerning the storage and utilization of energy due to the intermittent and seasonal nature of renewable energy sources. Wind and solar photovoltaic power productions are variable and difficult to predict, and thus electricity storage will be needed in the case of basic power production. Hydrogen’s energetic potential lies in its ability and versatility to store chemical energy, to serve as an energy carrier and as feedstock for various industries. Hydrogen is also used e.g. in the production of biofuels. The amount of energy produced during hydrogen combustion is higher than any other fuel’s on a mass basis with a higher-heating-value of 39.4 kWh/kg. However, even though hydrogen is the most abundant element in the universe, on Earth most hydrogen exists in molecular forms such as water. Therefore, hydrogen must be produced and there are various methods to do so. Today, the majority hydrogen comes from fossil fuels, mainly from steam methane reforming, and only about 4 % of global hydrogen comes from water electrolysis. Combination of electrolytic production of hydrogen from water and supply of renewable energy is attracting more interest due to the sustainability and the increased flexibility of the resulting energy system. The preferred option for intermittent hydrogen storage is pressurization in tanks since at ambient conditions the volumetric energy density of hydrogen is low, and pressurized tanks are efficient and affordable when the cycling rate is high. Pressurized hydrogen enables energy storage in larger capacities compared to battery technologies and additionally the energy can be stored for longer periods of time, on a time scale of months. In this thesis, the thermodynamics and electrochemistry associated with water electrolysis are described. The main water electrolysis technologies are presented with state-of-the-art specifications. Finally, a Power-to-Hydrogen infrastructure design for Lappeenranta University of Technology is presented. Laboratory setup for water electrolysis is specified and factors affecting its commissioning in Finland are presented.
Resumo:
The thesis work models the squeezing of the tube and computes the fluid motion of a peristaltic pump. The simulations have been conducted by using COMSOL Multiphysics FSI module. The model is setup in axis symmetric with several simulation cases to have a clear understanding of the results. The model captures total displacement of the tube, velocity magnitude, and average pressure fluctuation of the fluid motion. A clear understanding and review of many mathematical and physical concepts are also discussed with their applications in real field. In order to solve the problems and work around the resource constraints, a thorough understanding of mass balance and momentum equations, finite element concepts, arbitrary Lagrangian-Eulerian method, one-way coupling method, two-way coupling method, and COMSOL Multiphysics simulation setup are understood and briefly narrated.
Resumo:
Point-of-care (POC) –diagnostics is a field with rapidly growing market share. As these applications become more widely used, there is an increasing pressure to improve their performance to match the one of a central laboratory tests. Lanthanide luminescence has been widely utilized in diagnostics because of the numerous advantages gained by the utilization of time-resolved or anti-Stokes detection. So far the use of lanthanide labels in POC has been scarce due to limitations set by the instrumentation required for their detection and the shortcomings, e.g. low brightness, of these labels. Along with the advances in the research of lanthanide luminescence, and in the field of semiconductors, these materials are becoming a feasible alternative for the signal generation also in the future POC assays. The aim of this thesis was to explore ways of utilizing time-resolved detection or anti-Stokes detection in POC applications. The long-lived fluorescence for the time-resolved measurement can be produced with lanthanide chelates. The ultraviolet (UV) excitation required by these chelates is cumbersome to produce with POC compatible fluorescence readers. In this thesis the use of a novel light-harvesting ligand was studied. This molecule can be used to excite Eu(III)-ions at wavelengths extending up to visible part of the spectrum. An enhancement solution based on this ligand showed a good performance in a proof-of-concept -bioaffinity assay and produced a bright signal upon 365 nm excitation thanks to the high molar absorptivity of the chelate. These features are crucial when developing miniaturized readers for the time-resolved detection of fluorescence. Upconverting phosphors (UCPs) were studied as an internal light source in glucose-sensing dry chemistry test strips and ways of utilizing their various emission wavelengths and near-infrared excitation were explored. The use of nanosized NaYF :Yb3+,Tm3+-particles enabled the replacement of an external UV-light source with a NIR-laser and gave an additional degree of freedom in the optical setup of the detector instrument. The new method enabled a blood glucose measurement with results comparable to a current standard method of measuring reflectance. Microsized visible emitting UCPs were used in a similar manner, but with a broad absorbing indicator compound filtering the excitation and emission wavelengths of the UCP. This approach resulted in a novel way of benefitting from the non-linear relationship between the excitation power and emission intensity of the UCPs, and enabled the amplification of the signal response from the indicator dye.
Resumo:
PhotoAcoustic Imaging (PAI) is a branch in clinical and pre-clinical imaging, that refers to the techniques mapping acoustic signals caused by the absorption of the short laser pulse. This conversion of electromagnetic energy of the light to the mechanical (acoustic) energy is usually called photoacoustic effect. PAI, by combining optical excitation with acoustical detection, is able to preserve the diffraction limited spatial resolution. At the same time, the penetration depth is extended beyond the diffusive limit. The Laser-Scanning PhotoAcoustic Microscope system (LS-PAM) has been developed, that offers the axial resolution of 7.75 µm with the lateral resolution better than 10 µm. The first in vivo imaging experiments were carried out. Thus, in vivo label-free imaging of the mouse ear was performed. The principle possibility to image vessels located in deep layers of the mouse skin was shown. As well as that, a gold printing sample, vasculature of the Chick Chorioallantoic Membrane Assay, Drosophila larvae were imaged by PAI. During the experimental work, a totally new application of PAM was found, in which the acoustic waves, generated by incident light can be used for further imaging of another sample. In order to enhance the performance of the presented system two main recommendation can be offered. First, the current system should be transformed into reflection-mode setup system. Second, a more powerful source of light with the sufficient repetition rate should be introduced into the system.
Resumo:
Rare-earth based upconverting nanoparticles (UCNPs) have attracted much attention due to their unique luminescent properties. The ability to convert multiple photons of lower energy to ones with higher energy through an upconversion (UC) process offers a wide range of applications for UCNPs. The emission intensities and wavelengths of UCNPs are important performance characteristics, which determine the appropriate applications. However, insufficient intensities still limit the use of UCNPs; especially the efficient emission of blue and ultraviolet (UV) light via upconversion remains challenging, as these events require three or more near-infrared (NIR) photons. The aim of the study was to enhance the blue and UV upconversion emission intensities of Tm3+ doped NaYF4 nanoparticles and to demonstrate their utility in in vitro diagnostics. As the distance between the sensitizer and the activator significantly affect the energy transfer efficiency, different strategies were explored to change the local symmetry around the doped lanthanides. One important strategy is the intentional co-doping of active (participate in energy transfer) or passive (do not participate in energy transfer) impurities into the host matrix. The roles of doped passive impurities (K+ and Sc3+) in enhancing the blue and UV upconversions, as well as in influencing the intense UV upconversion emission through excess sensitization (active impurity) were studied. Additionally, the effects of both active and passive impurity doping on the morphological and optical performance of UCNPs were investigated. The applicability of UV emitting UCNPs as an internal light source for glucose sensing in a dry chemistry test strip was demonstrated. The measurements were in agreement with the traditional method based on reflectance measurements using an external UV light source. The use of UCNPs in the glucose test strip offers an alternative detection method with advantages such as control signals for minimizing errors and high penetration of the NIR excitation through the blood sample, which gives more freedom for designing the optical setup. In bioimaging, the excitation of the UCNPs in the transparent IR region of the tissue permits measurements, which are free of background fluorescence and have a high signal-to-background ratio. In addition, the narrow emission bandwidth of the UCNPs enables multiplexed detections. An array-in-well immunoassay was developed using two different UC emission colours. The differentiation between different viral infections and the classification of antibody responses were achieved based on both the position and colour of the signal. The study demonstrates the potential of spectral and spatial multiplexing in the imaging based array-in-well assays.
Resumo:
It is common knowledge of the world’s dependency on fossil fuel for energy, its unsustainability on the long run and the changing trend towards renewable energy as an alternative energy source. This aims to cut down greenhouse gas emission and its impact on the rate of ecological and climatic change. Quite remarkably, wind energy has been one of many focus areas of renewable energy sources and has attracted lots of investment and technological advancement. The objective of this research is to explore wind energy and its application in household heating. This research aims at applying experimental approach in real time to study and verify a virtually simulated wind powered hydraulic house heating system. The hardware components comprise of an integrated hydraulic pump, flow control valve, hydraulic fluid and other hydraulic components. The system design and control applies hardware in-the-loop (HIL) simulation setup. Output signal from the semi-empirical turbine modelling controls the integrated motor to generate flow. Throttling the volume flow creates pressure drop across the valve and subsequently thermal power in the system to be outputted using a heat exchanger. Maximum thermal power is achieved by regulating valve orifice to achieve optimum system parameter. Savonius rotor is preferred for its low inertia, high starting torque and ease of design and maintenance characteristics, but lags in power efficiency. A prototype turbine design is used; with power output in range of practical Savonius turbine. The physical mechanism of the prototype turbine’s augmentation design is not known and will not be a focus in this study.
Resumo:
In this thesis, bacteriorhodopsin (BR) photosensor’s optical and electrical properties were studied. The BR sensor consisted of a dry film with BR in polyvinyl alcohol and covered with transparent conductors. In the experiments the BR photocycle was started with two lasers. The characteristics of the BR sensor were measured in two ways. The first approach was theoretical and it required knowing the laser parameters. The second way required assembling a measurement setup for the optical response measurements. However, no measurable results were obtained due to low laser power. The photoelectric response was measured in the experiments with two laser systems and the amplifier was tested. In the experiment with a Cavitar laser, the photoelectric response was obtained. In the experiment with FemtoFiber Pro laser, the photoelectric response was not measured. The expected amplitude of the response was obtained. The experimental data was analyzed and possible solutions for reducing the interference were given.
Resumo:
Intelligence from a human source, that is falsely thought to be true, is potentially more harmful than a total lack of it. The veracity assessment of the gathered intelligence is one of the most important phases of the intelligence process. Lie detection and veracity assessment methods have been studied widely but a comprehensive analysis of these methods’ applicability is lacking. There are some problems related to the efficacy of lie detection and veracity assessment. According to a conventional belief an almighty lie detection method, that is almost 100% accurate and suitable for any social encounter, exists. However, scientific studies have shown that this is not the case, and popular approaches are often over simplified. The main research question of this study was: What is the applicability of veracity assessment methods, which are reliable and are based on scientific proof, in terms of the following criteria? o Accuracy, i.e. probability of detecting deception successfully o Ease of Use, i.e. easiness to apply the method correctly o Time Required to apply the method reliably o No Need for Special Equipment o Unobtrusiveness of the method In order to get an answer to the main research question, the following supporting research questions were answered first: What kinds of interviewing and interrogation techniques exist and how could they be used in the intelligence interview context, what kinds of lie detection and veracity assessment methods exist that are reliable and are based on scientific proof and what kind of uncertainty and other limitations are included in these methods? Two major databases, Google Scholar and Science Direct, were used to search and collect existing topic related studies and other papers. After the search phase, the understanding of the existing lie detection and veracity assessment methods was established through a meta-analysis. Multi Criteria Analysis utilizing Analytic Hierarchy Process was conducted to compare scientifically valid lie detection and veracity assessment methods in terms of the assessment criteria. In addition, a field study was arranged to get a firsthand experience of the applicability of different lie detection and veracity assessment methods. The Studied Features of Discourse and the Studied Features of Nonverbal Communication gained the highest ranking in overall applicability. They were assessed to be the easiest and fastest to apply, and to have required temporal and contextual sensitivity. The Plausibility and Inner Logic of the Statement, the Method for Assessing the Credibility of Evidence and the Criteria Based Content Analysis were also found to be useful, but with some limitations. The Discourse Analysis and the Polygraph were assessed to be the least applicable. Results from the field study support these findings. However, it was also discovered that the most applicable methods are not entirely troublefree either. In addition, this study highlighted that three channels of information, Content, Discourse and Nonverbal Communication, can be subjected to veracity assessment methods that are scientifically defensible. There is at least one reliable and applicable veracity assessment method for each of the three channels. All of the methods require disciplined application and a scientific working approach. There are no quick gains if high accuracy and reliability is desired. Since most of the current lie detection studies are concentrated around a scenario, where roughly half of the assessed people are totally truthful and the other half are liars who present a well prepared cover story, it is proposed that in future studies lie detection and veracity assessment methods are tested against partially truthful human sources. This kind of test setup would highlight new challenges and opportunities for the use of existing and widely studied lie detection methods, as well as for the modern ones that are still under development.
Resumo:
Raakamäntyöljy on selluteollisuuden sivutuote. Suopa erotetaan mustalipeästä ja palstoitetaan tuottaen siten raakamäntyöljyä. Raakamäntyöljy tislataan tavanomaisesti viiteen pääjakeeseen: rasvahapot, hartsihapot, mäntyöljytisle, esiöljy ja mäntyöljypiki. Näiden jakeiden lisäksi raakamäntyöljyssä on erityisesti mustalipeästä siihen erottuneita epäpuhtauksia, jotka haittaavat raakamäntyöljyn prosessointia. Epäpuhtauksia ovat orgaaniset ja epäorgaaniset yhdisteet, kuten metallit, suolat ja ligniini. Nämä epäpuhtaudet aiheuttavat haitallisia reaktioita prosessissa huonontaen siten lopputuotejakeiden laatua. Tämän lisäksi epäpuhtaudet aiheuttavat saostumia prosessilaitteissa alentaen siten prosessointitehokkuutta. Raakamäntyöljyn esikäsittelyllä tehostetaan tislauksen toimintaa. Työssä esitetään esikäsittelymenetelmistä mm. degumming-menetelmä, laimea happopesu, hiilidioksidikäsittely, valkaisu ja lämpökäsittely. Menetelmien pohjalta valitaan tätä työtä varten yksi menetelmä, jonka pohjalta suunnitellaan kokeellisessa osassa suoritettavat kokeet. Kokeellinen osuus koostuu esikokeista, varsinaisista kokeista ja lisäkokeista. Menetelmän tarkoituksena on saavuttaa epäpuhtauksille 90–95 % reduktioaste. Kokeiden onnistumista tutkitaan analysoimalla alkuperäinen raakamäntyöljy, sekä jokaisen kokeen jälkeen erotetut faasit. Työssä saavutettiin hyvä erotustehokkuus. Alkuperäisen tavoitteen mukaista reduktioastetta ei pystytty määrittämään eri analyysimenetelmien ja niiden analyysituloksissa ilmenneiden eroavaisuuksien vuoksi, mutta lisäkokeiden ansiosta pystyttiin vahvistamaan kyseisen koejärjestelmän optimaalinen poistoaste. Lisäksi työssä havaittiin että esikäsittelytulos on hyvin riippuvainen käsiteltävän raaka-aineen koostumuksesta.