49 resultados para Random Pulse Width Modulation, AC Motor Drives


Relevância:

30.00% 30.00%

Publicador:

Resumo:

This bachelor’s thesis is a part of the research project realized in the summer 2011 in Lappeenranta University of Technology. The goal of the project was to develop an automation concept for controlling the electrically excited synchronous motor. Thesis concentrates on the implementation of the automation concept into the ABB’s AC500 programmable logic enviroment. The automation program was developed as a state machine with the ABB’s PS501 Control Builder software. For controlling the automation program is developed a fieldbus control and with CodeSys Visualization Tool a local control with control panel. The fieldbus control is done to correspond the ABB drives communication profile and the local control is implemented with a function block which feeds right control words into the statemachine. A field current control of the synchronous motor is realized as a method presented in doctoral thesis of Olli Pyrhönen (Pyrhönen 1998). The Method combines stator flux and torque based openloop control and power factor based feedback control.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The two central goals of this master's thesis are to serve as a guidebook on the determination of uncertainty in efficiency measurements and to investigate sources of uncertainty in efficiency measurements in the field of electric drives by a literature review, mathematical modeling and experimental means. The influence of individual sources of uncertainty on the total instrumental uncertainty is investigated with the help of mathematical models derived for a balance and a direct air cooled calorimeter. The losses of a frequency converter and an induction motor are measured with the input-output method and a balance calorimeter at 50 and 100 % loads. A software linking features of Matlab and Excel is created to process measurement data, calculate uncertainties and to calculate and visualize results. The uncertainties are combined with both the worst case and the realistic perturbation method and distributions of uncertainty by source are shown based on experimental results. A comparison of the calculated uncertainties suggests that the balance calorimeter determines losses more accurately than the input-output method with a relative RPM uncertainty of 1.46 % compared to 3.78 - 12.74 % respectively with 95 % level of confidence at the 93 % induction motor efficiency or higher. As some principles in uncertainty analysis are open to interpretation the views and decisions of the analyst can have noticeable influence on the uncertainty in the measurement result.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A tumor is a fast-growing malignant tissue. This creates areas inside the tumor that are distant from local blood vessels to be able to get enough oxygen. This hypoxic condition activates a transcription factor called hypoxia inducible factor (HIF). HIF responses help a cell to adapt to decreased oxygen by activating glycolytic and angiogenesis pathways and by regulating apoptotic responses. Hypoxia drives the upregulation of a growth factor called transforming growth factor beta (TGF-beta). Similar to a hypoxia response, TGF is an important regulator of cell fate. TGF-β and HIF pathways regulate partially overlapping target genes. This regulation can also be cooperative. The TGF-beta signal is initiated by activation of plasma membrane receptors that then activate effector proteins called small mothers against decapentaplegic (Smad) homologs. In healthy tissue, TGF-β keeps cell proliferation and growth under control. During cancer progression, TGF-beta has shown a dual role, whereby it inhibits initial tumor formation but, conversely, in an existent tumor, TGF-beta drives malignant progression. Along with HIF and TGF-beta also protein dephosphorylation is an important regulatory mechanism of cell fate. Protein dephosphorylation is catalyzed by protein phosphatases such as Protein phosphatase 2A (PP2A). PP2A is a ubiquitous phosphatase that can exist in various active forms. PP2A can specifically regulate TGF-beta signaling either by enhancing or inhibiting the receptor activity. This work demonstrates that during hypoxia, PP2A is able to fine-tune TGF-beta signal by specifically targeting Smad3 effector in a Smad7-dependent manner. Inactivation of Smad3 in hypoxia leads to malignant conversion of TGF-beta signaling.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Preventive maintenance of frequency converters has been based on pre-planned replace-ment of wearing or ageing components. Exchange intervals follow component life-time expectations which are based on empirical knowledge or schedules defined by manufac-turer. However, the lifetime of a component can vary significantly, because drives are used in very different operating environments and applications. The main objective of the research was to provide information on methods, i.e. how in-verter's operating condition can be measured reliably under field conditions. At first, the research focused on critical components such as current transducers, IGBTs and DC link capacitor bank, because these aging have already been identified. Of these, the DC link capacitor measurement method was selected for closer examination. With this method, the total capacitance and its total series resistance can be measured. The suitability of the measuring procedure was estimated on the basis of practical measurements. The research was made by using so called triangulation method, including a literature review, simulations and practical measurements. Based on the results, the new measu-rement method seems suitable with some reservations to practical measurements. How-ever, the measuring method should be further developed in order to improve its reliability.