71 resultados para Aperture height index


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Atherosclerotic vascular disease is the leading cause of death in the Western world. Its main three manifestations are coronary heart disease, cerebrovascular disease, and peripheral arterial disease. Asymptomatic peripheral arterial disease is usually diagnosed using the ankle brachial index, and values ≤ 0.90 are used to determine the diagnosis. The classical risk factors of peripheral arterial disease, such as smoking and diabetes, are well known and early interventions are mandatory to improve the prognosis. What is not well known is the role of inflammation as a risk factor. Yet, a novel approach to cardiovascular diseases is the measurement of endothelial function. In this thesis, we studied the ankle-brachial index, C-reactive protein and endothelial function in a cardiovascular risk population. A total of 2856 subjects were invited to the study and 2085 (73%) responded. From these subjects, a cohort of 1756 risk persons was screened. We excluded the subjects with previously known cardiovascular disease or diabetes, because they were already under systematic follow-up. Out of the study subjects, 983 (56%) were women and 773 (44%) men. The ankle brachial index and high-sensitivity C-reactive protein were measured from 1047 subjects. Endothelial function was assessed by measuring reactive hyperemia pulse amplitude tonometry from 66 subjects with borderline peripheral arterial disease. In this study, smoking was a crucial risk factor for peripheral arterial disease. Subclinical peripheral arterial disease seems to be more common in hypertensive patients even without comorbidities. The measurement of the ankle brachial index is an efficient method to identify patients at an increased cardiovascular risk. High-sensitivity C-reactive protein did not correlate with the ankle brachial index or peripheral arterial disease. Instead, it correlated with measures of obesity. In a cardiovascular risk population with borderline peripheral arterial disease, nearly every fourth subject had endothelial dysfunction. This might point out a subgroup of individuals in need of more intensive treatment for their risk factors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Global illumination algorithms are at the center of realistic image synthesis and account for non-trivial light transport and occlusion within scenes, such as indirect illumination, ambient occlusion, and environment lighting. Their computationally most difficult part is determining light source visibility at each visible scene point. Height fields, on the other hand, constitute an important special case of geometry and are mainly used to describe certain types of objects such as terrains and to map detailed geometry onto object surfaces. The geometry of an entire scene can also be approximated by treating the distance values of its camera projection as a screen-space height field. In order to shadow height fields from environment lights a horizon map is usually used to occlude incident light. We reduce the per-receiver time complexity of generating the horizon map on N N height fields from O(N) of the previous work to O(1) by using an algorithm that incrementally traverses the height field and reuses the information already gathered along the path of traversal. We also propose an accurate method to integrate the incident light within the limits given by the horizon map. Indirect illumination in height fields requires information about which other points are visible to each height field point. We present an algorithm to determine this intervisibility in a time complexity that matches the space complexity of the produced visibility information, which is in contrast to previous methods which scale in the height field size. As a result the amount of computation is reduced by two orders of magnitude in common use cases. Screen-space ambient obscurance methods approximate ambient obscurance from the depth bu er geometry and have been widely adopted by contemporary real-time applications. They work by sampling the screen-space geometry around each receiver point but have been previously limited to near- field effects because sampling a large radius quickly exceeds the render time budget. We present an algorithm that reduces the quadratic per-pixel complexity of previous methods to a linear complexity by line sweeping over the depth bu er and maintaining an internal representation of the processed geometry from which occluders can be efficiently queried. Another algorithm is presented to determine ambient obscurance from the entire depth bu er at each screen pixel. The algorithm scans the depth bu er in a quick pre-pass and locates important features in it, which are then used to evaluate the ambient obscurance integral accurately. We also propose an evaluation of the integral such that results within a few percent of the ray traced screen-space reference are obtained at real-time render times.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Negative refractive index materials and propagation of electromagnetic waves in them started to draw attention of scientists not so long ago. This review highlights historically important and recent papers on practical and theoretical aspects related to these issues. Namely, basic properties and peculiarities of such materials related to both their design and wave propagation in them, experimental verification of predictions theoretically made for them, possible practical applications and prospects in this area are considered.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Julkaisussa: Atlas van zeevaert en koophandel door de geheele weereldt

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this thesis was to identify the determinants of bone strength and predictors of hip fracture in representative samples of Finnish adults. A secondary objective was to construct a simple multifactorial model for hip fracture prediction over a 10-year follow-up period. The study was based on the Health 2000 Survey conducted during 2000 to 2001 (men and women aged 30 years or over, n=6 035) and the Mini-Finland Health Survey conducted during 1978 to 1980 (women aged 45 years or over, n=2 039). Study subjects participated in health interviews and comprehensive health examination. In the Health 2000 Survey, bone strength was assessed by means of calcaneal quantitative ultrasound (QUS). The follow-up information about hip fractures was drawn from the National Hospital Discharge Register. In this study, age, weight, height, serum 25-hydroxyvitamin D (S-25(OH)D), physical activity, smoking and alcohol consumption as well as menopause and eventual HRT in women were found to be associated with calcaneal broadband ultrasound attenuation (BUA) and speed of sound (SOS). Parity was associated with a decreased risk of hip fracture in postmenopausal women. Age, height, weight or waist circumference, quantitative ultrasound index (QUI), S-25(OH)D and fall-related factors, such as maximal walking speed, Parkinson’s disease, and the number of prescribed CNS active medication were significant independent predictors of hip fracture. At the population level, the incremental value of QUS appeared to be minor in hip fracture prediction when the fall-related risk factors were taken into account. A simple multifactorial model for hip fracture prediction presented in this study was based on readily available factors (age, gender, height, waist circumference, and fallrelated factors). Prospective studies are needed to test this model in patient-based study populations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Invokaatio: In nomine Jesu!

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Invokaatio: In nomine Jesu!

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Invokaatio: In nomine Jesu.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Invokaatio: In nomine Jesu!

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Invokaatio: In nomine Jesu!

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Variantti B.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Invokaatio: In nomine Jesu!