54 resultados para light gauge cold-formed steel frame structures


Relevância:

30.00% 30.00%

Publicador:

Resumo:

This thesis introduces a search for a new design of the frame for a permanent magnet generator mounted at a windmill. The objective of this work is to offer new design ideas for the stator frame - new concepts for connecting stator core to stator frame in a generator. Desired aims of new design concepts are: simplification of the structure production; decrease of material use; use of standard components; light weight of construction and etc. Thesis contains several new possible designs for the stator frame structure. Also, it has a list of possible connection concepts, which can be used to join the stator to the frame. All new ideas are described and compared according to its match to the desired purposes of the work. New design concepts are modeled using modern software. The main part of the Thesis contains several approximate computer models of the current and new offered constructions, description of loads and stress in the current stator frame. It has evaluation of the most important stress and load characteristics. The final design is a result of all previous research. It has a description of a new frame structure and joining concept for it. This structure matched main aims of work, but it does not have detailed design with dimensions and check calculations of the frame and welds. Thesis gives representation about design search, evaluation and comparison of new concepts of generator structure. Also, it gives general representation of renewable energy technology, knowledge about windmill turbines and its contents.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

To predict the capacity of the structure or the point which is followed by instability, calculation of the critical crack size is important. Structures usually contain several cracks but not necessarily all of these cracks lead to failure or reach the critical size. So, defining the harmful cracks or the crack size which is the most leading one to failure provides criteria for structure’s capacity at elevated temperature. The scope of this thesis was to calculate fracture parameters like stress intensity factor, the J integral and plastic and ultimate capacity of the structure to estimate critical crack size for this specific structure. Several three dimensional (3D) simulations using finite element method by Ansys program and boundary element method by Frank 3D program were carried out to calculate fracture parameters and results with the aid of laboratory tests (loaddisplacement curve, the J resistance curve and yield or ultimate stress) leaded to extract critical size of the crack. Two types of the fracture which is usually affected by temperature, Elastic and Elasti-Plastic fractures were simulated by performing several linear elastic and nonlinear elastic analyses. Geometry details of the weldment; flank angle and toe radius were also studied independently to estimate the location of crack initiation and simulate stress field in early stages of crack extension in structure. In this work also overview of the structure’s capacity in room temperature (20 ºC) was studied. Comparison of the results in different temperature (20 ºC and -40 ºC) provides a threshold of the structure’s behavior within the defined range.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Muutoskatsastusta koskeva lainsäädäntö aiheuttaa tulkintavaikeuksia ja rajoitteita moottoripyöräharrastajille ja alan toimijoille. Nykyinen asetus edellyttää tarvittaessa asiantuntijaselvitystä rakennemuutoksen lujuudesta ja hitsaustyöstä. Moottoripyörän geometria on laissa rajattu akselivälin ja emäputken kulman osalta. Moottoripyörien runkoja valmistetaan hitsaamalla seostamattomista teräksistä ja lämpökäsiteltävistä alumiini- ja terässeoksista. Runkojen muuntelu suoritetaan myös yleisesti hitsaamalla. Turvallisuuden kannalta tärkeiltä hitsausliitoksilta vaaditaan hyvää laatua, joka saavutetaan oikeilla hitsausparametreilla ja -suorituksella. Vaatimukset seostamattomalle teräkselle voidaan täyttää pätevöityneen hitsaajan toimesta. Lämpökäsiteltävät seokset vaativat lisäksi jälkilämpökäsittelyn, mikä edelleen vaikeuttaa runkojen hitsausta. Hitsien laadun merkitystä moottoripyörän rungossa tutkittiin soveltamalla rajoitetun vahingon periaatetta. Vauriotapauksena mallinnettiin satunnaisen rungon hitsausliitoksen murtuminen. Eri kuormitustilanteissa elementtimenetelmää hyödyntäen todettiin chopper-tyyppisten moottoripyörien runkojen olevan osittain vauriosietoisia ja havaittiin kriittiset hitsausliitokset emä- ja vaakaputken alueilla. Moottoripyörien runkojen kriittisiä hitsausliitoksia tarkasteltiin väsymisen kannalta. Soveltamalla tehollista lovijännitystä, vertailtiin emäputken hitsausliitosten väsymiskestävyyttä oletetulla kuormituksella. Tulosten perusteella muunneltu moottoripyörän runko voi olla alkuperäisrunkoa kestävämpi tai heikompi. Moottoripyörän akseliväli tai emäputken kulma eivät määrää kestävyyttä, vaan rakenteen yksityiskohtainen suunnittelu. Kriittisten liitosten väsymiskestävyyksissä havaittiin merkittäviä eroja eri mallien välillä.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A small carbonatite dyke swarm has been identified at Naantali, southwest Finland. Several swarms of shoshonitic lamprophyres are also known along the Archean-Proterozoic boundary in eastern Finland and northwest Russia. These intrusions, along with the carbonatite intrusion at Halpanen, eastern Finland, represent a stage of widespread low-volume mantle-sourced alkaline magmatism in the Svecofennian Domain. Using trace element and isotope geochemistry coupled with precise geochronology from these rocks, a model is presented for the Proterozoic metasomatic evolution of the Fennoscandian subcontinental lithospheric mantle. At ~2.2-2.06 Ga, increased biological production in shallow seas linked to continental rifting, resulted in increased burial rates of organic carbon. Subduction between ~1.93-1.88 Ga returned organic carbon-enriched sediments of mixed Archean and Proterozoic provenance to the mantle. Dehydration reactions supplied water to the mantle wedge, driving arc volcanism, while mica, amphibole and carbonate were brought deeper into the mantle with the subducting slab. The cold subducted slab was heated conductively from the surrounding warm mantle, while pressures continued to gradually increase as a result of crustal thickening. The sediments began to melt in a two stage process, first producing a hydrous alkaline silicate melt, which infiltrated the mantle wedge and crystallised as metasomatic veins. At higher temperatures, carbonatite melt was produced, which preferentially infiltrated the pre-existing metasomatic vein network. At the onset of post-collisional extension, deep fault structures formed, providing conduits for mantle melts to reach the upper crust. Low-volume partial melting of the enriched mantle at depths of at least 110 km led to the formation of first carbonatitic magma and subsequently lamprophyric magma. Carbonatite was emplaced in the upper crust at Naantali at 1795.7 ± 6.8 Ma; lamprophyres along the Archean-Proterozoic boundary were emplaced between 1790.1 ± 3.3 Ma and 1781 ± 20 Ma.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this thesis was to study network structures and modularity among biofuel heating system manufacturers in the Finnish bioenergy sector by utilizing the perspectives of numerous Finnish bioenergy specialists. The study is qualitative due to the fact that the research material was gathered with semi-structured theme interviews during May and June 2010. The research methodology used in the thesis combines conceptual and action-oriented approach. Networks, value nets, and modularity were studied from different perspectives. Three network and platform strategies were discovered and a general network structure was formed. Moreover, benefits and disadvantages of networks and modularity among biofuel heating system manufacturers were illustrated. The analysis provides a comprehensive perception of the industry. The results of the research were constructed by implementing existing theories into practice. Also future recommendations for the biofuel heating system manufacturers were given. The results can be considered to be beneficial because the number of previous studies about the subject is relatively small. The reliability of the study is eminent because the number of the interviews was inclusive.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Tässä työssä tutkittiin Ruukin valmistamista lujista Optim 700 MC Plus sekä Optim 700 QL teräksistä tehtyjen hitsattujen palkkirakenteiden vikasietoisuutta sekä murtumiskäyttäytymistä laboratoriossa suoritettujen täyden mittakaavan kokeiden avulla. Koerakenteet suunniteltiin siten, että rakenteen kylmämuovauksen sekä hitsauksen vaikutukset yhdessä rakenteen geometrian vaikutuksen kanssa heikentävät rakenteen murtumissitkeyttä rakenteeseen tehdyn teräväkärkisen alkusärön tasossa. Suunnitellussa koesarjassa varioidaan testauslämpötilan lisäksi hitsauksen lämmöntuontia sekä koerakenteeseen tehtävän alkusärön kokoa. Tässä työssä tavoitteena oli yleisesti esittää menettely hitsatun säröllisen teräsrakenteen kestävyyden arviointia varten. Optim 700 MC Plus teräksestä tehdyn koerakenteen käyttäytymistä tutkittiin laskennallisesti murtumismekaniikan avulla. Laadittujen FEM - mallien avulla laskettiin rakenteen murtumisparametrien arvot kummallekin tutkittavalle teräkselle. Optim 700 MC Plus materiaalista valmistetuille koerakenteen säröalueen rakennedetaljia vastaavalle koekappaleille suoritettiin murtumissitkeyskokeita. Murtumissitkeyskokeista saatujen tulosten avulla pystyttiin kuvaamaan täyden mittakaavan koerakenteessa olevan särön murtumiskäyttäytymistä mitoitusmenetelmissä. Koerakenteelle laskettiin tässä työssä kriittisen särökoon ja sitä vastaavan kuorman arvot perustuen rakenteen oletettuun hauraaseen, epästabiiliin sitkeään sekä plastiseen murtumiskäyttäytymiseen. Tässä työssä testattiin molemmista tutkittavista materiaaleista valmistetut täyden mittakaavan koerakenteet -40 °C lämpötilassa. Molemmat testatut rakenteet käyttäytyvät mitattujen siirtymätulosten perusteella melko hauraasti. Optim 700 MC Plus materiaalille saatujen laskentatulosten voidaan todeta testatun koekappaleen perusteella soveltuvan hauraasti käyttäytyvän rakenteen mitoitukseen.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Knowledge of the behaviour of cellulose, hemicelluloses, and lignin during wood and pulp processing is essential for understanding and controlling the processes. Determination of monosaccharide composition gives information about the structural polysaccharide composition of wood material and helps when determining the quality of fibrous products. In addition, monitoring of the acidic degradation products gives information of the extent of degradation of lignin and polysaccharides. This work describes two capillary electrophoretic methods developed for the analysis of monosaccharides and for the determination of aliphatic carboxylic acids from alkaline oxidation solutions of lignin and wood. Capillary electrophoresis (CE), in its many variants is an alternative separation technique to chromatographic methods. In capillary zone electrophoresis (CZE) the fused silica capillary is filled with an electrolyte solution. An applied voltage generates a field across the capillary. The movement of the ions under electric field is based on the charge and hydrodynamic radius of ions. Carbohydrates contain hydroxyl groups that are ionised only in strongly alkaline conditions. After ionisation, the structures are suitable for electrophoretic analysis and identification through either indirect UV detection or electrochemical detection. The current work presents a new capillary zone electrophoretic method, relying on in-capillary reaction and direct UV detection at the wavelength of 270 nm. The method has been used for the simultaneous separation of neutral carbohydrates, including mono- and disaccharides and sugar alcohols. The in-capillary reaction produces negatively charged and UV-absorbing compounds. The optimised method was applied to real samples. The methodology is fast since no other sample preparation, except dilution, is required. A new method for aliphatic carboxylic acids in highly alkaline process liquids was developed. The goal was to develop a method for the simultaneous analysis of the dicarboxylic acids, hydroxy acids and volatile acids that are oxidation and degradation products of lignin and wood polysaccharides. The CZE method was applied to three process cases. First, the fate of lignin under alkaline oxidation conditions was monitored by determining the level of carboxylic acids from process solutions. In the second application, the degradation of spruce wood using alkaline and catalysed alkaline oxidation were compared by determining carboxylic acids from the process solutions. In addition, the effectiveness of membrane filtration and preparative liquid chromatography in the enrichment of hydroxy acids from black liquor was evaluated, by analysing the effluents with capillary electrophoresis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Glass is a unique material with a long history. Several glass products are used daily in our everyday life, often unnoticed. Glass can be found not only in obvious applications such as tableware, windows, and light bulbs, but also in tennis rackets, windmill turbine blades, optical devices, and medical implants. The glasses used at present as implants are inorganic silica-based melt-derived compositions mainly for hard-tissue repair as bone graft substitute in dentistry and orthopedics. The degree of glass reactivity desired varies according to implantation situation and it is vital that the ion release from any glasses used in medical applications is controlled. Understanding the in vitro dissolution rate of glasses provides a first approximation of their behavior in vivo. Specific studies concerning dissolution properties of bioactive glasses have been relatively scarce and mostly concentrated to static condition studies. The motivation behind this work was to develop a simple and accurate method for quantifying the in vitro dissolution rate of highly different types of glass compositions with interest for future clinical applications. By combining information from various experimental conditions, a better knowledge of glass dissolution and the suitability of different glasses for different medical applications can be obtained. Thus, two traditional and one novel approach were utilized in this thesis to study glass dissolution. The chemical durability of silicate glasses was tested in water and TRIS-buffered solution at static and dynamic conditions. The traditional in vitro testing with a TRISbuffered solution under static conditions works well with bioactive or with readily dissolving glasses, and it is easy to follow the ion dissolution reactions. However, in the buffered solution no marked differences between the more durable glasses were observed. The hydrolytic resistance of the glasses was studied using the standard procedure ISO 719. The relative scale given by the standard failed to provide any relevant information when bioactive glasses were studied. However, the clear differences in the hydrolytic resistance values imply that the method could be used as a rapid test to get an overall idea of the biodegradability of glasses. The standard method combined with the ion concentration and pH measurements gives a better estimate of the hydrolytic resistance because of the high silicon amount released from a glass. A sensitive on-line analysis method utilizing inductively coupled plasma optical emission spectrometer and a flow-through micro-volume pH electrode was developed to study the initial dissolution of biocompatible glasses. This approach was found suitable for compositions within a large range of chemical durability. With this approach, the initial dissolution of all ions could be measured simultaneously and quantitatively, which gave a good overall idea of the initial dissolution rates for the individual ions and the dissolution mechanism. These types of results with glass dissolution were presented for the first time during the course of writing this thesis. Based on the initial dissolution patterns obtained with the novel approach using TRIS, the experimental glasses could be divided into four distinct categories. The initial dissolution patterns of glasses correlated well with the anticipated bioactivity. Moreover, the normalized surface-specific mass loss rates and the different in vivo models and the actual in vivo data correlated well. The results suggest that this type of approach can be used for prescreening the suitability of novel glass compositions for future clinical applications. Furthermore, the results shed light on the possible bioactivity of glasses. An additional goal in this thesis was to gain insight into the phase changes occurring during various heat treatments of glasses with three selected compositions. Engineering-type T-T-T curves for glasses 1-98 and 13-93 were stablished. The information gained is essential in manufacturing amorphous porous implants or for drawing of continuous fibers of the glasses. Although both glasses can be hot worked to amorphous products at carefully controlled conditions, 1-98 showed one magnitude greater nucleation and crystal growth rate than 13-93. Thus, 13-93 is better suited than 1-98 for working processes which require long residence times at high temperatures. It was also shown that amorphous and partially crystalline porous implants can be sintered from bioactive glass S53P4. Surface crystallization of S53P4, forming Na2O∙CaO∙2SiO2, was observed to start at 650°C. The secondary crystals of Na2Ca4(PO4)2SiO4, reported for the first time in this thesis, were detected at higher temperatures, from 850°C to 1000°C. The crystal phases formed affected the dissolution behavior of the implants in simulated body fluid. This study opens up new possibilities for using S53P4 to manufacture various structures, while tailoring their bioactivity by controlling the proportions of the different phases. The results obtained in this thesis give valuable additional information and tools to the state of the art for designing glasses with respect to future clinical applications. With the knowledge gained we can identify different dissolution patters and use this information to improve the tuning of glass compositions. In addition, the novel online analysis approach provides an excellent opportunity to further enhance our knowledge of glass behavior in simulated body conditions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This doctoral thesis presents a study on the development of a liquid-cooled frame salient pole permanent-magnet-exited traction machine for a four-wheel-driven electric car. The emphasis of the thesis is put on a radial flux machine design in order to achieve a light-weight machine structure for traction applications. The design features combine electromagnetic and thermal design methods, because traction machine operation does not have a strict operating point. Arbitrary load cycles and the flexible supply require special attention in the design process. It is shown that accurate modelling of the machine magnetic state is essential for high-performance operation. The saturation effect related to the cross-saturation has to be taken carefully into account in order to achieve the desired operation. Two prototype machines have been designed and built for testing: one totally enclosed machine with a special magnet module pole arrangement and another through-ventilated machine with a more traditional embedded magnet structure. Both structures are built with magnetically salient structures in order to increase the torque production capability with the reluctance torque component. Both machine structures show potential for traction usage. However, the traditional embedded magnet design turns out to be mechanically the more secure one of these two machine options.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study investigated the surface hardening of steels via experimental tests using a multi-kilowatt fiber laser as the laser source. The influence of laser power and laser power density on the hardening effect was investigated. The microhardness analysis of various laser hardened steels was done. A thermodynamic model was developed to evaluate the thermal process of the surface treatment of a wide thin steel plate with a Gaussian laser beam. The effect of laser linear oscillation hardening (LLOS) of steel was examined. An as-rolled ferritic-pearlitic steel and a tempered martensitic steel with 0.37 wt% C content were hardened under various laser power levels and laser power densities. The optimum power density that produced the maximum hardness was found to be dependent on the laser power. The effect of laser power density on the produced hardness was revealed. The surface hardness, hardened depth and required laser power density were compared between the samples. Fiber laser was briefly compared with high power diode laser in hardening medium-carbon steel. Microhardness (HV0.01) test was done on seven different laser hardened steels, including rolled steel, quenched and tempered steel, soft annealed alloyed steel and conventionally through-hardened steel consisting of different carbon and alloy contents. The surface hardness and hardened depth were compared among the samples. The effect of grain size on surface hardness of ferritic-pearlitic steel and pearlitic-cementite steel was evaluated. In-grain indentation was done to measure the hardness of pearlitic and cementite structures. The macrohardness of the base material was found to be related to the microhardness of the softer phase structure. The measured microhardness values were compared with the conventional macrohardness (HV5) results. A thermodynamic model was developed to calculate the temperature cycle, Ac1 and Ac3 boundaries, homogenization time and cooling rate. The equations were numerically solved with an error of less than 10-8. The temperature distributions for various thicknesses were compared under different laser traverse speed. The lag of the was verified by experiments done on six different steels. The calculated thermal cycle and hardened depth were compared with measured data. Correction coefficients were applied to the model for AISI 4340 steel. AISI 4340 steel was hardened by laser linear oscillation hardening (LLOS). Equations were derived to calculate the overlapped width of adjacent tracks and the number of overlapped scans in the center of the scanned track. The effect of oscillation frequency on the hardened depth was investigated by microscopic evaluation and hardness measurement. The homogeneity of hardness and hardened depth with different processing parameters were investigated. The hardness profiles were compared with the results obtained with conventional single-track hardening. LLOS was proved to be well suitable for surface hardening in a relatively large rectangular area with considerable depth of hardening. Compared with conventional single-track scanning, LLOS produced notably smaller hardened depths while at 40 and 100 Hz LLOS resulted in higher hardness within a depth of about 0.6 mm.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Electrocoagulation is a process in which wastewater is treated under electrical current. Coagulant is formed during the process through the metal anode dissolution to respective ions which react with hydroxyl ions released in cathode. These metal hydroxides form complexes with pollutant ions. Pollutants are removed among metal hydroxide precipitates. This study was concentrated on describing chemistry and device structures in which electrochemical treatment operations are based on. Studied pollutants were nitrogen compounds, sulphate, trivalent and pentavalent arsenic, heavy metals, phosphate, fluoride, chloride, and bromide. In experimental part, removal of ammonium, nitrate, and sulphate during electrochemical treatment was studied separately. Main objective of this study was to find suitable metal plate material for ammonium, nitrate, and sulphate removal, respectively. Also other parameters such as pH of solution, concentration of pollutant and sodium chloride, and current density were optimized. According to this study the most suitable material for ammonium and sulphate removal by electrochemical treatment was stainless steel. Respectively, iron was the optimum material for nitrate removal. Rise in the pH of solution at the final stage of electrochemical treatment of ammonium, nitrate, and sulphate was detected. Conductivities of solutions decreased during ammonium removal in electrochemical processes. When nitrate and sulphate were removed electrochemically conductivities of solutions increased. Concentrations of residual metals in electrochemically treated solutions were not significant. Based on this study electrochemical treatment processes are recommended to be used in treatment of industrial wastewaters. Treatment conditions should be optimized for each wastewater matrix.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

High strength steel (HSS) has been in use in workshops since the 1980s. At that time, the significance of the term HSS differed from the modern conception as the maximum yield strength of HSSs has increased nearly every year. There are three different ways to make HSS. The first and oldest method is QT (quenched and tempered) followed by the TMCP (thermomechanical controlled process) and DQ (direct quenching) methods. This thesis consists of two parts, the first of which part introduces the research topic and discusses welded HSS structures by characterizing the most important variables. In the second part of the thesis, the usability of welded HSS structures is examined through a set of laboratory tests. The results of this study explain the differences in the usability of the welded HSSs made by the three different methods. The results additionally indicate that usage of different HSSs in the welded structures presumes that manufacturers know what kind of HSS they are welding. As manufacturers use greater strength HSSs in welded structures, the demands for welding rise as well. Therefore, during the manufacturing process, factors such as heat input, cooling time, weld quality, and more must be under careful observation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The number of molecular diagnostic assays has increased tremendously in recent years.Nucleic acid diagnostic assays have been developed, especially for the detection of human pathogenic microbes and genetic markers predisposing to certain diseases. Closed-tube methods are preferred because they are usually faster and easier to perform than heterogenous methods and in addition, target nucleic acids are commonly amplified leading to risk of contamination of the following reactions by the amplification product if the reactions are opened. The present study introduces a new closed-tube switchable complementation probes based PCR assay concept where two non-fluorescent probes form a fluorescent lanthanide chelate complex in the presence of the target DNA. In this dual-probe PCR assay method one oligonucleotide probe carries a non-fluorescent lanthanide chelate and another probe a light absorbing antenna ligand. The fluorescent lanthanide chelate complex is formed only when the non-fluorescent probes are hybridized to adjacent positions into the target DNA bringing the reporter moieties in close proximity. The complex is formed by self-assembled lanthanide chelate complementation where the antenna ligand is coordinated to the lanthanide ion captured in the chelate. The complementation probes based assays with time-resolved fluorescence measurement showed low background signal level and hence, relatively high nucleic acid detection sensitivity (low picomolar target concentration). Different lanthanide chelate structures were explored and a new cyclic seven dentate lanthanide chelate was found suitable for complementation probe method. It was also found to resist relatively high PCR reaction temperatures, which was essential for the PCR assay applications. A seven-dentate chelate with two unoccupied coordination sites must be used instead of a more stable eight- or nine-dentate chelate because the antenna ligand needs to be coordinated to the free coordination sites of the lanthanide ion. The previously used linear seven-dentate lanthanide chelate was found to be unstable in PCR conditions and hence, the new cyclic chelate was needed. The complementation probe PCR assay method showed high signal-to-background ratio up to 300 due to a low background fluorescence level and the results (threshold cycles) in real-time PCR were reached approximately 6 amplification cycles earlier compared to the commonly used FRET-based closed-tube PCR method. The suitability of the complementation probe method for different nucleic acid assay applications was studied. 1) A duplex complementation probe C. trachomatis PCR assay with a simple 10-minute urine sample preparation was developed to study suitability of the method for clinical diagnostics. The performance of the C. trachomatis assay was equal to the commercial C. trachomatis nucleic acid amplification assay containing more complex sample preparation based on DNA extraction. 2) A PCR assay for the detection of HLA-DQA1*05 allele, that is used to predict the risk of type 1 diabetes, was developed to study the performance of the method in genotyping. A simple blood sample preparation was used where the nucleic acids were released from dried blood sample punches using high temperature and alkaline reaction conditions. The complementation probe HLA-DQA1*05 PCR assay showed good genotyping performance correlating 100% with the routinely used heterogenous reference assay. 3) To study the suitability of the complementation probe method for direct measurement of the target organism, e.g., in the culture media, the complementation probes were applied to amplificationfree closed-tube bacteriophage quantification by measuring M13 bacteriophage ssDNA. A low picomolar bacteriophage concentration was detected in a rapid 20- minute assay. The assay provides a quick and reliable alternative to the commonly used and relatively unreliable UV-photometry and time-consuming culture based bacteriophage detection methods and indicates that the method could also be used for direct measurement of other micro-organisms. The complementation probe PCR method has a low background signal level leading to a high signal-to-background ratio and relatively sensitive nucleic acid detection. The method is compatible with simple sample preparation and it was shown to tolerate residues of urine, blood, bacteria and bacterial culture media. The common trend in nucleic acid diagnostics is to create easy-to-use assays suitable for rapid near patient analysis. The complementation probe PCR assays with a brief sample preparation should be relatively easy to automate and hence, would allow the development of highperformance nucleic acid amplification assays with a short overall assay time.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Growing demand for stainless steel construction materials has increased the popularity of substitutive materials for austenitic stainless steels. The lean duplex grades have taken their place in building of structures exposed to corrosive environments. Since the duplex grades are relatively new materials, the current codes and norms do not fully cover the newest duplex grades. The joints tested in this thesis were designed and studied according to Eurocode 3, even though all the materials are not yet accepted to the standards. The main objective in this thesis was to determine the differences of the used materials in behaviour under loading at low temperatures. Tests in which the deformation and strength properties of the joints were determined were done at the temperature of -46°C, which is the requirement of temperature for structures designed according to Norsok standards. Results show that replacing the austenitic grade with the lean duplex grade is acceptable.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Optimization of high strength and toughness combination on the effect of weldability is very vital to be considered in offshore oil and gas industries. Having a balanced and improved high strength and toughness is very much recommended in offshore structures for an effective production and viable exploration of hydrocarbons. This thesis aims to investigate the possibilities to improve the toughness of high strength steel. High carbon contents induce hardness and needs to be reduced for increasing toughness. The rare combination of high strength with high toughness possibilities was examined by determining the following toughening mechanism of: Heat treatment and optimal microstructure, Thermomechanical processing, Effect of welding parameters on toughness and weldability of steel. The implementation of weldability of steels to attain high toughness for high strength in offshore structures is mostly in shipbuilding, offshore platforms, and pipelines for high operating pressures. As a result, the toughening mechanisms suggested have benefits to the aims of the effect of high strength to high toughness of steel for efficiency, production and cost reduction.