53 resultados para flexural test


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this thesis, the components important for testing work and organisational test process are identified and analysed. This work focuses on the testing activities in reallife software organisations, identifying the important test process components, observing testing work in practice, and analysing how the organisational test process could be developed. Software professionals from 14 different software organisations were interviewed to collect data on organisational test process and testing‐related factors. Moreover, additional data on organisational aspects was collected with a survey conducted on 31 organisations. This data was further analysed with the Grounded Theory method to identify the important test process components, and to observe how real‐life test organisations develop their testing activities. The results indicate that the test management at the project level is an important factor; the organisations do have sufficient test resources available, but they are not necessarily applied efficiently. In addition, organisations in general are reactive; they develop their process mainly to correct problems, not to enhance their efficiency or output quality. The results of this study allows organisations to have a better understanding of the test processes, and develop towards better practices and a culture of preventing problems, not reacting to them.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents the design for a graphical parameter editor for Testing and Test Control Notation 3 (TTCN-3) test suites. This work was done in the context of OpenTTCN IDE, a TTCN-3 development environment built on top of the Eclipse platform. The design presented relies on an additional parameter editing tab added to the launch configurations for test campaigns. This parameter editing tab shows the list of editable parameters and allows opening editing components for the different parameters. Each TTCN-3 primitive type will have a specific editing component providing tools to ease modification of values of that type.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

CHARGE syndrome, Sotos syndrome and 3p deletion syndrome are examples of rare inherited syndromes that have been recognized for decades but for which the molecular diagnostics only have been made possible by recent advances in genomic research. Despite these advances, development of diagnostic tests for rare syndromes has been hindered by diagnostic laboratories having limited funds for test development, and their prioritization of tests for which a (relatively) high demand can be expected. In this study, the molecular diagnostic tests for CHARGE syndrome and Sotos syndrome were developed, resulting in their successful translation into routine diagnostic testing in the laboratory of Medical Genetics (UTUlab). In the CHARGE syndrome group, mutation was identified in 40.5% of the patients and in the Sotos syndrome group, in 34%, reflecting the use of the tests in routine diagnostics in differential diagnostics. In CHARGE syndrome, the low prevalence of structural aberrations was also confirmed. In 3p deletion syndrome, it was shown that small terminal deletions are not causative for the syndrome, and that testing with arraybased analysis provides a reliable estimate of the deletion size but benign copy number variants complicate result interpretation. During the development of the tests, it was discovered that finding an optimal molecular diagnostic strategy for a given syndrome is always a compromise between the sensitivity, specificity and feasibility of applying a new method. In addition, the clinical utility of the test should be considered prior to test development: sometimes a test performing well in a laboratory has limited utility for the patient, whereas a test performing poorly in the laboratory may have a great impact on the patient and their family. At present, the development of next generation sequencing methods is changing the concept of molecular diagnostics of rare diseases from single tests towards whole-genome analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

kuv., 8 x 15 cm

Relevância:

20.00% 20.00%

Publicador:

Resumo:

kuv., 10 x 15 cm

Relevância:

20.00% 20.00%

Publicador:

Resumo:

kuv., 10 x 15 cm

Relevância:

20.00% 20.00%

Publicador:

Resumo:

kuv., 8 x 15 cm

Relevância:

20.00% 20.00%

Publicador:

Resumo:

kuv., 10 x 15 cm

Relevância:

20.00% 20.00%

Publicador:

Resumo:

kuv., 10 x 15 cm

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Multibody simulation model of the roller test rig is presented in this work. The roller test rig consists of a paper machine’s tube roll supported with a hard bearing type balancing machine. The simulation model includes non-idealities that are measured from the physical structure. These non-idealities are the shell thickness variation of the roll and roundness errors of the shafts of the roll. These kinds of non-idealities are harmful since they can cause subharmonic resonances of the rotor system. In this case, the natural vibration mode of the rotor is excited when the rotation speed is a fraction of the natural frequency of the system. With the simulation model, the half critical resonance is studied in detail and a sensitivity analysis is performed by simulating several analyses with slightly different input parameters. The model is verified by comparing the simulation results with those obtained by measuring the real structure. Comparison shows that good accuracy is achieved, since equivalent responses are achieved within the error limit of the input parameters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The goal of the Master’s thesis is to design a test stand for a centrifugal compressor. Different theoretical aspects of flow parameters measurements and test rigs built for the similar purposes in other research units are described in the theoretical part of the work. The process of components selection and the description of chosen components are given in the second part of the thesis. Besides measuring and control stages, the designed test stand has a closed-loop piping, an aftercooler and a surge tank. Overview and layout of the test rig is presented in the last chapter of the work.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fiber-reinforced composites (FRCs) are a new group of non-metallic biomaterials showing a growing popularity in many dental and medical applications. As an oral implant material, FRC is biocompatible in bone tissue environment. Soft tissue integration to FRC polymer material is unclear. This series of in vitro studies aimed at evaluating unidirectional E-glass FRC polymer in terms of mechanical, chemical, and biological properties in an attempt to develop a new non-metallic oral implant abutment alternative. Two different types of substrates were investigated: (a) Plain polymer (BisGMA 50%–TEGDMA 50%) and (b) Unidirectional FRC. The mechanical behavior of high fiber-density FRCs was assessed using a three-point bending test. Surface characterization was performed using scanning electron and spinning disk confocal microscopes. The surface wettability/energy was determined using sessile drop method. The blood response, including blood-clotting ability and platelet morphology was evaluated. Human gingival fibroblast cell responses - adhesion kinetics, adhesion strength, and proliferation activity - were studied in cell culture environment using routine test conditions. A novel tissue culture method was developed and used to evaluate porcine gingival tissue graft attachment and growth on the experimental composite implants. The analysis of the mechanical properties showed that there is a direct proportionality in the relationship between E-glass fiber volume fraction and toughness, modulus of elasticity, and load bearing capacity; however, flexural strength did not show significant improvement when high fiber-density FRC is used. FRCs showed moderate hydrophilic properties owing to the presence of exposed glass fibers on the polymer surface. Blood-clotting time was shorter on FRC substrates than on plain polymer. The FRC substrates also showed higher platelet activation state than plain polymer substrates. Fibroblast cell adhesion strength and proliferation rate were highly pronounced on FRCs. A tissue culture study revealed that gingival epithelium and connective tissue established an immediate close contact with both plain polymer and FRC implants. However, FRC seemed to guide epithelial migration outwards from the tissue/implant interface. Due to the anisotropic and hydrophilic nature of FRC, it can be concluded that this material enhances biological events related with soft tissue integration on oral implant surface.