64 resultados para energy harvesting,bimorph cantilever,resonance frequency,electrical tuning,MPPT algorithm


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Electrical motors on a ship attackable to different factors which decrease these lifetimes. One of the main external factors on a ship which usually is a reason of the motor failure is a moisture condensation which decreases the motor winding insulation and increase a probability of the short circuit. Therefore, the protection against moisture is necessary for ship electrical motors. The motor should be protected against moisture all time when it does not operate. The necessity of such protection requires a lot of energy consumption. This master’s thesis is focused on the creation of the electrical motor thermal model and on the different methods of the motor protection against moisture analysis with energy consumption point of view.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A coupled system simulator, based on analytical circuit equations and a finite element method (FEM) model of the motor has been developed and it is used to analyse a frequency-converterfed industrial squirrel-cage induction motor. Two control systems that emulate the behaviour of commercial direct-torque-controlled (DTC) and vector-controlled industrial frequency converters have been studied, implemented in the simulation software and verified by extensive laboratory tests. Numerous factors that affect the operation of a variable speed drive (VSD) and its energy efficiency have been investigated, and their significance in the simulation of the VSD results has been studied. The dependency of the frequency converter, induction motor and system losses on the switching frequency is investigated by simulations and measurements at different speeds for both the vector control and the DTC. Intensive laboratory measurements have been carried out to verify the simulation results.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The increasing power demand and emerging applications drive the design of electrical power converters into modularization. Despite the wide use of modularized power stage structures, the control schemes that are used are often traditional, in other words, centralized. The flexibility and re-usability of these controllers are typically poor. With a dedicated distributed control scheme, the flexibility and re-usability of the system parts, building blocks, can be increased. Only a few distributed control schemes have been introduced for this purpose, but their breakthrough has not yet taken place. A demand for the further development offlexible control schemes for building-block-based applications clearly exists. The control topology, communication, synchronization, and functionality allocationaspects of building-block-based converters are studied in this doctoral thesis. A distributed control scheme that can be easily adapted to building-block-based power converter designs is developed. The example applications are a parallel and series connection of building blocks. The building block that is used in the implementations of both the applications is a commercial off-the-shelf two-level three-phase frequency converter with a custom-designed controller card. The major challenge with the parallel connection of power stages is the synchronization of the building blocks. The effect of synchronization accuracy on the system performance is studied. The functionality allocation and control scheme design are challenging in the seriesconnected multilevel converters, mainly because of the large number of modules. Various multilevel modulation schemes are analyzed with respect to the implementation, and this information is used to develop a flexible control scheme for modular multilevel inverters.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A centralized robust position control for an electrical driven tooth belt drive is designed in this doctoral thesis. Both a cascaded control structure and a PID based position controller are discussed. The performance and the limitations of the system are analyzed and design principles for the mechanical structure and the control design are given. These design principles are also suitable for most of the motion control applications, where mechanical resonance frequencies and control loop delays are present. One of the major challenges in the design of a controller for machinery applications is that the values of the parameters in the system model (parameter uncertainty) or the system model it self (non-parametric uncertainty) are seldom known accurately in advance. In this thesis a systematic analysis of the parameter uncertainty of the linear tooth beltdrive model is presented and the effect of the variation of a single parameter on the performance of the total system is shown. The total variation of the model parameters is taken into account in the control design phase using a Quantitative Feedback Theory (QFT). The thesis also introduces a new method to analyze reference feedforward controllers applying the QFT. The performance of the designed controllers is verified by experimentalmeasurements. The measurements confirm the control design principles that are given in this thesis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Centrifugal pumps are widely used in industrial and municipal applications, and they are an important end-use application of electric energy. However, in many cases centrifugal pumps operate with a significantly lower energy efficiency than they actually could, which typically has an increasing effect on the pump energy consumption and the resulting energy costs. Typical reasons for this are the incorrect dimensioning of the pumping system components and inefficiency of the applied pump control method. Besides the increase in energy costs, an inefficient operation may increase the risk of a pump failure and thereby the maintenance costs. In the worst case, a pump failure may lead to a process shutdown accruing additional costs. Nowadays, centrifugal pumps are often controlled by adjusting their rotational speed, which affects the resulting flow rate and output pressure of the pumped fluid. Typically, the speed control is realised with a frequency converter that allows the control of the rotational speed of an induction motor. Since a frequency converter can estimate the motor rotational speed and shaft torque without external measurement sensors on the motor shaft, it also allows the development and use of sensorless methods for the estimation of the pump operation. Still today, the monitoring of pump operation is based on additional measurements and visual check-ups, which may not be applicable to determine the energy efficiency of the pump operation. This doctoral thesis concentrates on the methods that allow the use of a frequency converter as a monitoring and analysis device for a centrifugal pump. Firstly, the determination of energy-efficiency- and reliability-based limits for the recommendable operating region of a variable-speed-driven centrifugal pump is discussed with a case study for the laboratory pumping system. Then, three model-based estimation methods for the pump operating location are studied, and their accuracy is determined by laboratory tests. In addition, a novel method to detect the occurrence of cavitation or flow recirculation in a centrifugal pump by a frequency converter is introduced. Its sensitivity compared with known cavitation detection methods is evaluated, and its applicability is verified by laboratory measurements for three different pumps and by using two different frequency converters. The main focus of this thesis is on the radial flow end-suction centrifugal pumps, but the studied methods can also be feasible with mixed and axial flow centrifugal pumps, if allowed by their characteristics.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Nowadays power drives are the essential part almost of all technological processes. Improvement of efficiency and reduction of losses require development of semiconductor switches. It has a particular meaning for the constantly growing market of renewable sources, especially for wind turbines, which demand more powerful semiconductor devices for control with growth of power. Also at present semiconductor switches are the key component in energy transmission, optimization of generation and network connection. The aim of this thesis is to make a survey of contemporary semiconductor components, showing difference in structures, advantages, disadvantages and most suitable applications. There is topical information about voltage, frequency and current limits of different switches. Study tries to compare dimensions and price of different components. Main manufacturers of semiconductor components are presented with the review of devices produced by them, and a conclusion about their availability was made. IGBT is selected as a main component in this study, because nowadays it is the most attractive component for usage in power drives, especially at the low levels of medium voltage. History of development of IGBT structure, static and dynamic characteristics are considered. Thesis tells about assemblies and connection of components and problems which can appear. One of key questions about semiconductor materials and their future development was considered. For the purpose of comparison strong and weak sides of different switches, calculation of losses of IGBT and its basic competitor – IGCT is presented. This master’s thesis makes an effort to answer the question if there are at present possibilities of accurate selection of switches for electrical drives of different rates of power and looks at future possible ways of development of semiconductor market.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Paineilmaa on kutsuttu neljänneksi perushyödykkeeksi veden, sähkön ja kaasun lisäksi. Paineilman kuluttaja on usein myös sen tuottaja. EU:n alueen teollisuudessa keskimää-rin 16 % kulutetusta kokonaissähkötehosta kuluu ilmakompressoreiden käyttöön. Taa-juusmuuttajan käyttö on viime vuosikymmeninä lisääntynyt merkittävästi, kun on pyrit-ty energiatehokkaisiin ratkaisuihin esimerkiksi pumppaus- ja puhallinjärjestelmissä. Kompressorijärjestelmissä taajuusmuuttajien käyttö ei ole vielä yhtä yleistä kuin esi-merkiksi pumppukäytöissä, vaikka taajuusmuuttajan käytöllä saavutetaan useimmissa tapauksissa huomattavia etuja. Tässä työssä tutkitaan taajuusmuuttajan hyödyntämismahdollisuuksia kompressorijär-jestelmien käytönaikaisten elinkaarikustannusten optimoimisessa. Työssä selvitetään säästöpotentiaalia, ja pohditaan pyörimisnopeussäädöllä saavutettavia etuja eri komp-ressorityypeillä. Lopuksi muodostetaan elinkaarikustannusanalyysit kahdelle todelliselle teollisuuden kompressorikohteelle. Tutkimusmenetelminä ovat kirjallisuustyö sekä asi-antuntijahaastattelut teollisuudesta. Työn tavoitteena on kartoittaa taajuusmuuttajan hyödyntämispotentiaalia kompressorijärjestelmissä ja luoda pohjaa mahdolliselle jatko-tutkimukselle.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

One of the targets of the climate and energy package of the European Union is to increase the energy efficiency in order to achieve a 20 percent reduction in primary energy use compared with the projected level by 2020. The energy efficiency can be improved for example by increasing the rotational speed of large electrical drives, because this enables the elimination of gearboxes leading to a compact design with lower losses. The rotational speeds of traditional bearings, such as roller bearings, are limited by mechanical friction. Active magnetic bearings (AMBs), on the other hand, allow very high rotational speeds. Consequently, their use in large medium- and high-speed machines has rapidly increased. An active magnetic bearing rotor system is an inherently unstable, nonlinear multiple-input, multiple-output system. Model-based controller design of AMBs requires an accurate system model. Finite element modeling (FEM) together with the experimental modal analysis provides a very accurate model for the rotor, and a linearized model of the magneticactuators has proven to work well in normal conditions. However, the overall system may suffer from unmodeled dynamics, such as dynamics of foundation or shrink fits. This dynamics can be modeled by system identification. System identification can also be used for on-line diagnostics. In this study, broadband excitation signals are adopted to the identification of an active magnetic bearing rotor system. The broadband excitation enables faster frequency response function measurements when compared with the widely used stepped sine and swept sine excitations. Different broadband excitations are reviewed, and the random phase multisine excitation is chosen for further study. The measurement times using the multisine excitation and the stepped sine excitation are compared. An excitation signal design with an analysis of the harmonics produced by the nonlinear system is presented. The suitability of different frequency response function estimators for an AMB rotor system are also compared. Additionally, analytical modeling of an AMB rotor system, obtaining a parametric model from the nonparametric frequency response functions, and model updating are discussed in brief, as they are key elements in the modeling for a control design. Theoretical methods are tested with a laboratory test rig. The results conclude that an appropriately designed random phase multisine excitation is suitable for the identification of AMB rotor systems.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Approximately a quarter of electrical power consumption in pulp and paper industry is used in different pumping systems. Therefore, improving pumping system efficiency is a considerable way to reduce energy consumption in different processes. Pumping of wood pulp in different consistencies is common in pulp and paper industry. Earlier, centrifugal pumps were used to pump pulp only at low consistencies, but development of MC technology has made it possible to pump medium consistency pulp. Pulp is a non-Newtonian fluid, which flow characteristics are significantly different than what of water. In this thesis is examined the energy efficiency of pumping medium consistency pulp with centrifugal pump. The factors effecting the pumping of MC pulp are presented and through case study is examined the energy efficiency of pumping in practice. With data obtained from the case study are evaluated the effects of pump rotational speed and pulp consistency on energy efficiency. Additionally, losses caused by control valve and validity of affinity laws in pulp pumping are evaluated. The results of this study can be used for demonstrating the energy consumption of MC pumping processes and finding ways to improve energy efficiency in these processes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In recent years the environmental issues and the energy saving have become increasingly import in modern society where industry is the major emission factor and energy consumer. Generally, most of the total energy consumption is caused by electrical drives used in industrial applications and thus improving the performance of electrical drives give an opportunity to improve the energy efficiency. In this Master Thesis improving the energy efficiency in different electrical drives is clarified with different cases: regenerative braking in the electric grid or recovery of the braking energy into an energy storage. In addition, as an example, the energy consumption of an elevator is analyzed by measurements. From these measurement results it can be estimated how much the share of the standby energy consumption is from the total energy consumption and how much regenerative energy is available. The latter part of the thesis concentrates on determination of the properties of lithium iron phosphate battery with measurements.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Centrifugal pumps are a notable end-consumer of electrical energy. Typical application of a centrifugal pump is the filling or emptying of a reservoir tank, where the pump is often operated at a constant speed until the process is completed. Installing a frequency converter to control the motor substitutes the traditional fixed-speed pumping system, allows the optimization of rotational speed profile for the pumping tasks and enables the estimation of rotational speed and shaft torque of an induction motor without any additional measurements from the motor shaft. Utilization of variable-speed operation provides the possibility to decrease the overall energy consumption of the pumping task. The static head of the pumping process may change during the pumping task. In such systems, the minimum rotational speed changes during reservoir filling or emptying, and the minimum energy consumption can’t be achieved with a fixed rotational speed. This thesis presents embedded algorithms to automatically identify, optimize and monitor pumping processes between supply and destination reservoirs, and evaluates the changing static head –based optimization method.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Suomessa sähkönjakelu on säännelty monopoli. Energiamarkkinavirasto tuottaa ohjeistuksen sekä mallin yritysten ansaintamahdollisuuksille. Karkeasti sanottuna tulomalli on sijoitetun pääoman ja pääoman painotetun kustannuksen tulo. Pääoman painotettu kustannus koostuu useista parametreista kuten beta ja vieraan pääoman riskipreemio. Näiden parametrien taso ja määrittämisajankohta perustuvat subjektiivisiin näkemyksiin, kun objektiivista parametrien määrittämismenetelmää tulisi käyttää. Nykyiset beta ja vieraan pääoman riskipreemio perustuvat energiamarkkinaviraston ja asiantuntijoiden lausuntoihin. Aihealuetta on tutkittu erittäin vähän, mikä johtunee pääasiassa siitä, ettei ole olemassa listautuneita puhtaita jakeluverkkoyhtiöitä. Betan nykytaso on 0.529 ja vieraan pääoman riskipreemio on 1.0 %. Tässä pro gradu –työssä määritetään markkinaperusteisesti betan ja vieraan pääoman riskipreemion nykytaso. Tässä työssä esiteltävä määrittämismalli perustuu puhtaasti markkinadataan eikä sen soveltamisessa käytetä subjektiivisia mielipiteitä. Markkinaehtoisia tietoja käyttäen betan pitäisi olla tasolla 0.525 ja vieraan pääoman riskipreemion tasolla 1.34 %. Nämä luvut, mikäli ne otettaisiin käyttöön, vaikuttaisivat suoraan ja positiivisesti jakeluverkkoyhtiöiden sallittuun tuottoon Suomessa.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Sähköavusteinen polkupyörä on hieman tavallista polkupyörää vahvarakenteisempi ja painavampi. Lisäpainoa tuovat muun muassa akut ja sähkömoottori, joka avustaa polke-mista. Moottori asennetaan yleensä eturenkaan keskiöön. Suurimmassa osassa, jollei kaikissa, kaupallisista sähköavusteisissa polkupyörissä moottori on hiiliharjaton tasavirta-moottori. Hiiliharjattoman tasavirtamoottorin pyörimisnopeutta ja vääntömomenttia voidaan säätää usealla eri tavalla. Markkinoilla olevat säätimet perustuvat poikkeuksetta pulssinleveys-modulaatioon. Tämän työn tarkoituksena on tutkia, onko säätöjärjestelmä mahdollista to-teuttaa muulla tavalla kuin pulssinleveysmodulaattorilla. Tutkimuksessa päädytään käyt-tämään amplitudimodulointia, jolloin taajuus voidaan pitää vakiona. Tämän tutkimuksen rinnalla samaan polkupyörään rakennetaan polkemisenergian avulla akkuja lataava la-tausjärjestelmä. Tämän kandityön puitteissa tutkimus jää kesken, mutta toiminta osoitetaan teoreettisesti ja simuloimalla. Suurin syy kokeellisen testauksen epäonnistumiseen on käytettyjen kom-ponenttien sopimattomuus sovellukseen.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Transportation of fluids is one of the most common and energy intensive processes in the industrial and HVAC sectors. Pumping systems are frequently subject to engineering malpractice when dimensioned, which can lead to poor operational efficiency. Moreover, pump monitoring requires dedicated measuring equipment, which imply costly investments. Inefficient pump operation and improper maintenance can increase energy costs substantially and even lead to pump failure. A centrifugal pump is commonly driven by an induction motor. Driving the induction motor with a frequency converter can diminish energy consumption in pump drives and provide better control of a process. In addition, induction machine signals can also be estimated by modern frequency converters, dispensing with the use of sensors. If the estimates are accurate enough, a pump can be modelled and integrated into the frequency converter control scheme. This can open the possibility of joint motor and pump monitoring and diagnostics, thereby allowing the detection of reliability-reducing operating states that can lead to additional maintenance costs. The goal of this work is to study the accuracy of rotational speed, torque and shaft power estimates calculated by a frequency converter. Laboratory tests were performed in order to observe estimate behaviour in both steady-state and transient operation. An induction machine driven by a vector-controlled frequency converter, coupled with another induction machine acting as load was used in the tests. The estimated quantities were obtained through the frequency converter’s Trend Recorder software. A high-precision, HBM T12 torque-speed transducer was used to measure the actual values of the aforementioned variables. The effect of the flux optimization energy saving feature on the estimate quality was also studied. A processing function was developed in MATLAB for comparison of the obtained data. The obtained results confirm the suitability of this particular converter to provide accurate enough estimates for pumping applications.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pumping systems account for over 20 % of all electricity consumption in European industry. Optimization and correct design of such systems is important and there is a reasonable amount of unrealized energy saving potential in old pumping systems. The energy efficiency and therefore also the energy consumption of a pumping system heavily depends on the correct dimensioning and selection of devices. In this work, a graphical optimization tool for pumping systems is developed in Matlab programming language. The tool selects optimal pump, electrical motor and frequency converter for existing pumping process and calculates the life cycle costs of the whole system. The tool could be used as an aid when choosing the machinery and to analyze the energy consumption of existing systems. Results given by the tool are compared to the results of laboratory tests. The selection of pump and motor works reasonably well, but the frequency converter selection still needs development